manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Controllers
  8. •
  9. Emerson FISHER 6492L User manual

Emerson FISHER 6492L User manual

Introduction
This installation guide provides instructions for installation,
startup and adjustment. To receive a copy of the
instruction manual, contact your local Sales Office or view
a copy at www.fisher.com. For further information refer to:
Type 92S Instruction Manual, D100637X012.
PED Categories
This product may be used as a safety accessory with
pressure equipment in the following Pressure Equipment
Directive categories. It may also be used outside of the
Pressure Equipment Directive using sound engineering
practice (SEP) per table below. For information on the
current PED revision see Bulletin: D103053X012.
PRODUCT SIZE CATEGORIES FLUID TYPE
1/4 NPT SEP 1
Specifications
Maximum Inlet and Outlet Pressures(1)
See Table 2
Outlet Pressure Ranges
See Table 1
Proof Test Pressure
All Pressure Retaining Components have been
proof tested per Directive.
Maximum Temperature Capabilities
Cast Iron: 208°C / 406°F
Steel: 260°C / 500°F
Optional High Temperature Steel and Stainless
Steel Construction: 343°C / 650°F
Installation
!
WARNING
Only qualified personnel should install
or service a regulator. Regulators
should be installed, operated and
maintained in accordance with
international and applicable codes
and regulations and Emerson Process
Management Regulator Technologies,
Inc. instructions.
If the regulator vents fluid or a leak
develops in the system, it indicates that
service is required. Failure to take the
regulator out of service immediately may
create a hazardous condition.
Personal injury, equipment damage or
leakage due to escaping fluid or bursting
of pressure-containing parts may result
if this regulator is overpressured or
is installed where service conditions
could exceed the limits given in the
Specifications section, or where
conditions exceed any ratings of the
adjacent piping or piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation or standard) to
prevent service conditions from
exceeding limits.
Additionally, physical damage to the
regulator could result in personal injury
and property damage due to escaping
fluid. To avoid such injury and damage,
install the regulator in a safe location.
Clean out all pipelines before installation of the
regulator and check to be sure the regulator has not
been damaged or has collected foreign material during
shipping. For NPT bodies, apply pipe compound to
the external pipe threads. For flanged bodies, use
suitable line gaskets and approved piping and bolting
practices. Install the regulator in any position desired,
unless otherwise specified, but be sure flow through
the body is in the direction indicated by the arrow on
the body.
1. The pressure/temperature limits in this installation guide and any applicable standard or code limitation should not be exceeded.
Table 1. Outlet (Control) Pressure Ranges
PILOT TYPE OUTLET PRESSURE RANGE
bar psig
6492L
0.14 to 0.41 2 to 6
0.34 to 1.0 5 to 15
0.90 to 1.7 13 to 25
6492H
0.69 to 2.1 10 to 30
1.7 to 5.2 25 to 75
4.8 to 10.3 70 to 150
6492HT 1.0 to 6.9 15 to 100
5.5 to 17.2 80 to 250
Type 6492
Installation Guide
D103055X014
English – October 2013
Note
It is important that the regulator be
installed so that the vent hole in the
spring case is unobstructed at all times.
For outdoor installations, the regulator
should be located away from vehicular
traffic and positioned so that water, ice
and other foreign materials cannot enter
the spring case through the vent. Avoid
placing the regulator beneath eaves or
downspouts, and be sure it is above the
probable snow level.
Overpressure Protection
The recommended pressure limitations are
stamped on the regulator nameplate. Some type of
overpressure protection is needed if the actual inlet
pressure exceeds the maximum operating outlet
pressure rating. Overpressure protection should
also be provided if the regulator inlet pressure
is greater than the safe working pressure of the
downstream equipment.
Regulator operation below the maximum pressure
limitations does not preclude the possibility of damage
from external sources or debris in the line. The
regulator should be inspected for damage after any
overpressure condition.
Startup
The regulator is factory set at approximately
the midpoint of the spring range or the pressure
requested, so an initial adjustment may be required
to give the desired results. With proper installation
completed and relief valves properly adjusted, slowly
open the upstream and downstream shutoff valves.
Adjustment
To change the outlet pressure, remove the closing
cap or loosen the locknut and turn the adjusting
screw clockwise to increase outlet pressure or
counterclockwise to decrease pressure. Monitor
the outlet pressure with a test gauge during the
adjustment. Replace the closing cap or tighten the
locknut to maintain the desired setting.
Taking Out of Service (Shutdown)
!
WARNING
To avoid personal injury resulting from
sudden release of pressure, isolate
the regulator from all pressure before
attempting disassembly.
Parts List
Types 6492L and 6492H
Key Description
1 Body
2 Valve Guide
3 Valve Spring
4* Inner Valve
5* Orice
7* Valve Stem
8* Bellows Retainer
9* Bellows
10* Diaphragm
11 Lower Spring Seat, Types 6492H and 6492HT Pilots only
12 Control Spring
13 Upper Spring Seat
14 Spring Case
15 Adjusting Screw, standard spring case only
16 Hex Nut, standard spring case only
17 Cap Screw
18* Diaphragm Gasket
19 Drive Screw
20 Nameplate
24 Diaphragm Plate Assembly, Type 6492L Pilot only
74 Pipe Plug
76 Bleed Restriction
77 Screen
78 Reducing Bushing
87 Sealing Washer, tapped spring case only
TYPE
MAXIMUM ALLOWABLE INLET PRESSURE MAXIMUM OPERATING
OUTLET PRESSURE MAXIMUM EMERGENCY OUTLET PRESSURE
Cast Iron Steel/Stainless Steel
bar psig bar psig bar psig Cast Iron Body Steel/Stainless Steel Body
6492HT - - - - - - - - 20.7 300 17.2 250 - - - -
20.7 bar / 300 psig or main
valve body rating limit,
whichever is lower
6492H 17.2 250 20.7 300 10.3 150
17.2 bar / 250 psig or main
valve body rating limit,
whichever is lower
20.7 bar / 300 psig or main
valve body rating limit,
whichever is lower
6492L 17.2 250 20.7 300 1.7 25 6.9 bar / 100 psig 6.9 bar / 100 psig
Table 2. Maximum Inlet and Outlet Pressures
*Recommended spare part.
Type 6492
2
15
11
10
18
5
77
2
3
4
74 78
1
76
17
19
20
14
16
7
8
9
12
13
Figure 1. Type 6492H or 6492HT Pilot Assembly
39A3514-B
Figure 2. Type 6492L Pilot Assembly
39A3515-B
78
74
76
77
5
1
18
10
24
15
13
12
9
8
7
4
3
2
17
19
20
14
16
APPLY LUBRICANT/SEALANT/ADHESIVE
Type 6492
3
Type 6492
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation
[email protected]
Emerson Automation Solutions
For further information on the current
PED revision see Bulletin: D103053X012
or scan the QR code.
Fisher.com
Americas
McKinney, Texas 75070 USA
T +1 800 558 5853
+1 972 548 3574
Europe
Bologna 40013, Italy
T +39 051 419 0611
Asia Pacic
Singapore 128461, Singapore
T +65 6777 8211
Middle East and Africa
Dubai, United Arab Emirates
T +971 4 811 8100
D103055X014 © 2002, 2018 Emerson Process Management Regulator
Technologies, Inc. All rights reserved. 09/18.
The Emerson logo is a trademark and service mark of Emerson
Electric Co. All other marks are the property of their prospective owners.
Fisher™ is a mark owned by Fisher Controls International LLC, a
business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes
only, and while effort has been made to ensure their accuracy, they are
not to be construed as warranties or guarantees, express or implied,
regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which
are available on request. We reserve the right to modify or improve the
designs or specications of our products at any time without notice.
Emerson Process Management Regulator Technologies, Inc does not
assume responsibility for the selection, use or maintenance of any
product. Responsibility for proper selection, use and maintenance of any
Emerson Process Management Regulator Technologies, Inc. product
remains solely with the purchaser.

This manual suits for next models

3

Other Emerson Controllers manuals

Emerson Fisher 1078 User manual

Emerson

Emerson Fisher 1078 User manual

Emerson unidrive m200 User manual

Emerson

Emerson unidrive m200 User manual

Emerson Unidrive M400 User manual

Emerson

Emerson Unidrive M400 User manual

Emerson EXD-HP1/2 User manual

Emerson

Emerson EXD-HP1/2 User manual

Emerson Digistart IS1x0043B series User manual

Emerson

Emerson Digistart IS1x0043B series User manual

Emerson Fisher 4194S User manual

Emerson

Emerson Fisher 4194S User manual

Emerson FloBoss 104 Quick guide

Emerson

Emerson FloBoss 104 Quick guide

Emerson Fisher 299H User manual

Emerson

Emerson Fisher 299H User manual

Emerson FISHER 627F User manual

Emerson

Emerson FISHER 627F User manual

Emerson FISHER SR8 User manual

Emerson

Emerson FISHER SR8 User manual

Emerson Fisher FIELDVUE DVC6200 SIS User manual

Emerson

Emerson Fisher FIELDVUE DVC6200 SIS User manual

Emerson Fisher Y600A Series User manual

Emerson

Emerson Fisher Y600A Series User manual

Emerson Fisher 630 Series User manual

Emerson

Emerson Fisher 630 Series User manual

Emerson Bettis G01 Series Installation instructions

Emerson

Emerson Bettis G01 Series Installation instructions

Emerson Dixell XV308K User manual

Emerson

Emerson Dixell XV308K User manual

Emerson Alco Controls EC3 Series User manual

Emerson

Emerson Alco Controls EC3 Series User manual

Emerson PACSystems RX3i User manual

Emerson

Emerson PACSystems RX3i User manual

Emerson Fisher Type B NG User manual

Emerson

Emerson Fisher Type B NG User manual

Emerson Aventics 617 Series User manual

Emerson

Emerson Aventics 617 Series User manual

Emerson 289A User manual

Emerson

Emerson 289A User manual

Emerson Dixell XRi60CH Wiring diagram

Emerson

Emerson Dixell XRi60CH Wiring diagram

Emerson Bettis RTS User manual

Emerson

Emerson Bettis RTS User manual

Emerson Fisher 67C Series User manual

Emerson

Emerson Fisher 67C Series User manual

Emerson Bettis RP3E User manual

Emerson

Emerson Bettis RP3E User manual

Popular Controllers manuals by other brands

JNGE Power MPPT user manual

JNGE Power

JNGE Power MPPT user manual

EAS Electric ECG145CM instruction manual

EAS Electric

EAS Electric ECG145CM instruction manual

okii MC1 quick guide

okii

okii MC1 quick guide

Graco Series B instructions

Graco

Graco Series B instructions

YASKAWA SI-EM3 Technical manual

YASKAWA

YASKAWA SI-EM3 Technical manual

HP 9000 Series 300 Service handbook

HP

HP 9000 Series 300 Service handbook

Lincoln Electric HARRIS 705 Series instruction manual

Lincoln Electric

Lincoln Electric HARRIS 705 Series instruction manual

Lynn Electronics CTR2-Mini+ Assembly manual

Lynn Electronics

Lynn Electronics CTR2-Mini+ Assembly manual

Millipore Tylan General FC-2900 instruction manual

Millipore

Millipore Tylan General FC-2900 instruction manual

Trane Tracer VV551 quick start guide

Trane

Trane Tracer VV551 quick start guide

ComAp L151006001 installation manual

ComAp

ComAp L151006001 installation manual

McConnel V3 Proportional Operator's manual

McConnel

McConnel V3 Proportional Operator's manual

JUMO B 703571.0 operating manual

JUMO

JUMO B 703571.0 operating manual

Siemens SIRIUS 3RW40 2 operating instructions

Siemens

Siemens SIRIUS 3RW40 2 operating instructions

Siemens SIRIUS 3RA1.5 operating instructions

Siemens

Siemens SIRIUS 3RA1.5 operating instructions

WEIGL ProCommander Series Menu Plan

WEIGL

WEIGL ProCommander Series Menu Plan

Zamel Cet LediX SLR-11P manual

Zamel

Zamel Cet LediX SLR-11P manual

Orion MBR 70 installation manual

Orion

Orion MBR 70 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.