manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Industrial Equipment
  8. •
  9. Emerson SDU 24-BATEM User manual

Emerson SDU 24-BATEM User manual

SDU 24-BATEM INSTRUCTION MANUAL
SDU 24-BATEM External Battery
IMPORTANT SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
This manual contains important safety instructions. Read all safety, installation, and operating instructions before operating the Uninterruptible Power System
(UPS). Adhere to all warnings on the unit and in this manual. Follow all operating and user instructions.
This equipment is designed for Industrial or Commercial use.
!
WARNING – EXPLOSION HAZARD! This product is NOT FOR USE in a Hazardous Locations Environment.
!
WARNING – Observe all cautions and warnings in this manual. Failure to do so MAY result in serious injury or death. Refer all UPS and battery service to
qualied service personnel. Do not attempt to service this product yourself. Never work alone.
!
WARNING – Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep
unauthorized personnel away from the batteries. PROPER DISPOSAL OF BATTERIES IS REQUIRED. REFER TO YOUR LOCAL LAWS AND
REGULATIONS FOR BATTERY DISPOSAL REQUIREMENTS.
!
CAUTION – Always disconnect this External Battery Module from the SDU Power module before replacing the batteries.
!
CAUTION – When replacing the batteries, use the same number and type of batteries. See the “SDU 24-BATEM Battery Replacement Instructions” section
below for battery manufacturer and type required for replacement.
!
CAUTION – Do not dispose of battery or batteries in a re. The battery may explode.
Do not open or mutilate the battery or batteries. Released electrolyte is harmful to skin and eyes. It may be toxic.
For battery recycling information, contact CSB recycling network at : 1-800-738-7372
WHAT’S INCLUDED
1. SDU 24-BATEM: External battery module.
2. SDU 24-EXTBC6: Pair of 6 foot polarized cables for connecting the external battery module to the power module
NOTE: The circuit breaker must be in the open position “O” prior to installation.
SDU 24-BATEM INSTALLATION
The SDU 24-BATEM can be installed as stand alone equipment. The NEMA 1 enclosure features removable cover and knockout holes to ease the
installation process.
If necessary, the black and red terminals of the polarized cable SDU 24-EXTBC6 can be detached from one another to separate the black wire from the red wire
and allow them to slide easily through the conduit.
Before closing the circuit breaker of SDU 24-BATEM, make sure that one end of the red terminals of the polarized cable is connected to the red terminal of the
SDU DC UPS power module and the other red terminal end of the polarized cable is connected to the red terminal of the external battery module SDU 24-BATEM.
The same approach applies to the black terminals.
TECHNICAL SUPPORT & WARRANTY INFORMATION
Contact Technical Support: 1-800-377-4384 • 1-847-268-6651 • [email protected] • www.solahd.com
For warranty information: Please see the enclosed Terms & Conditions of Sale sheet.
!
USER MANUAL
While every precaution has been taken to ensure accuracy and completeness in this manual, Appleton Grp LLC d/b/a Appleton Group assumes no responsibility, and disclaims all liability for damages resulting from use of this
information or for any errors or omissions. Specications are subject to change without notice.
P/N: A272-148 Rev. 2 9/2021
© 2021 Appleton Grp LLC d/b/a
Appleton Group. All rights reserved.
Page 2SDU 24-BATEM Instruction Manual • A272-148 Rev. 2 9/2021
BACK-UP TIME OF SDU DC UPS WITH SDU 24-BATEM (IN MINUTES) VERSUS LOAD PERCENTAGE
REMARK: Resistive loads were used to measure the battery run time, using other types of load may result in different battery run time. Run times are based on
new, fully charged battery module at a temperature of 25°C (77°F). Run times may vary due to manufacturing variance of the individual batteries.
DC UPS with SDU 24-BATEM External Battery Pack (EBP)
The external battery module SDU 24-BATEM includes two (2) user replaceable batteries.
SDU 10-24B with SDU 24-BATEM
Load 20% (2A) 40% (4A) 60% (6A) 80% (8A) 100% (10A)
1 EBP 135 52 28 19 14
SDU 20-24B with SDU 24-BATEM
Load 20% (4A) 40% (8A) 60% (12A) 80% (16A) 100% (20A)
1 EBP 48 17 9 6 4
SDU 24-BATEM SPECIFICATIONS
Parameter SDU 24-BATEM
Nominal Voltage 24 VDC
Protection Circuit Breaker: 24V, 25A
Charging Current 1.2
Enclosure Dimension in. (mm) 11.5 x 5.57 x 4.57 (292 x 142 x 116)
Enclosure Type NEMA 1
Terminal Connector Type Polarized Powerpole Connectors
Batteries Replaceable - Refer to the instructions for replacement.
Accessories 6 ft polarized battery cable
Operating Temperature -20o to +50o C
Charge Temperature 0o to +40o C
Storage Temperature -20o to +40o C
Humidity 95% no condensation
Certications
cULus Listed: UL 508/CSA 107.1, UL/CSA 61010-1, UL/CSA 61010-2-201
cRUus: UL/CSA 60950-1, UL/CSA 62368-1
CE/UKCA: IEC/EN 62368-1, IEC/EN 61010-1,
IEC/EN 61010-2-201
Weight lbs (kg) 16 (7.26)
Mounting Wall/Chassis Mounting
SDU 24-BATEM Instruction Manual • A272-148 Rev. 2 9/2021 Page 3
SDU DC UPS WIRING DIAGRAM - DC UPS WITH EXTERNAL BATTERY MODULE SDU 24-BATEM
NOTE: Only one (1) SDU 24-BATEM module can be connected with the power module SDU 10-24B or SDU 20-24B.
SDU 24-BATEM BATTERY REPLACEMENT INSTRUCTIONS
!
CAUTION – A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed before replacing
the batteries:
• Remove rings, watches, and other metal objects.
• Do not lay tools or other metal objects on top of the batteries.
• Do not dispose of batteries in a re. The batteries may explode.
• Dispose of old batteries according to local codes.
!
CAUTION – ELECTRICAL SAFETY PRE-CAUTIONS MUST BE FOLLOWED WHEN INSTALLING OR SERVICING THIS EQUIPMENT. TO PREVENT
RISK OF ELECTRICAL SHOCK, TURN OFF AND LOCK OUT ALL POWER SOURCES TO THE UNIT BEFORE MAKING ELECTRICAL CONNECTIONS
OR SERVICING.
!
CAUTION – WHEN REMOVING AND INSTALLING THE NEW BATTERIES, EXTREME CARE MUST BE USED NOT TO SHORT METAL CHASSIS
PARTS ACROSS THE BATTERY TERMINALS AND NOT TO SHORT THE BATTERIES TO EACH OTHER OR PERSONAL INJURY MAY RESULT.
NOTE: Caution should be exercised when replacing the batteries because the load is unprotected from disturbances and power outages during this procedure.
SDU 24-BATEM Batteries Replacement
The following battery type must be used as a replacement in this product.
Manufacturer Type Rating
CSB GP1272 12 V dc, 7.2 Ah
Page 4SDU 24-BATEM Instruction Manual • A272-148 Rev. 2 9/2021
SDU 24-BATEM BATTERY REPLACEMENT INSTRUCTIONS (CONTINUED)
Steps to Replace the Batteries
Step 1: Remove four (4) screws from cover and slide cover forward
off enclosure.
Step 2: Remove wires from battery posts
Step 3: Remove four (4) screws from enclosure but secure bracket
in place and then slide bracket forward from enclosure.
Step 4: Remove failed batteries and insert new
Replaceable Batteries.
SDU 24-BATEM Instruction Manual • A272-148 Rev. 2 9/2021 Page 5
Step 5: Slide bracket forward inside the enclosure, secure bracket
in place and use the four (4) screws to mount the bracket
on the enclosure.
Step 6: Use the following connection diagram to assure the correct
batteries connection to the polarized terminal connector
and to the circuit breaker.
R=RED TERMINAL
B=BLACK TERMINAL
CB=CIRCUIT BREAKER
RR
B
++
+
-
B
CB
-
-
Polarized
Terminal
Step 7: Slide the top cover on the enclosure then use the four (4)
screws for a secure mounting.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Appleton Grp LLC d/b/a Appleton Group. SolaHD is a registered trademark of Appleton Grp LLC. All other marks are
the property of their respective owners.
© 2021 Emerson Electric Co. All rights reserved.
United States
(Headquarters)
Appleton Grp LLC
9377 W. Higgins Road
Rosemont, IL 60018
United States
T +1 800 621 1506
Australia Sales O󰀩ce
Bayswater, Victoria
T +61 3 9721 0348
Europe
ATX SAS
Espace Industriel Nord
35, rue André Durouchez,
CS 98017
80084 Amiens Cedex 2
France
T +33 3 2254 1390
China Sales O󰀩ce
Shanghai
T +86 21 3338 7000
Canada
EGS Electrical Group
Canada Ltd.
99 Union Street
Elmira ON, N3B 3L7
Canada
T +1 888 765 2226
Middle East Sales O󰀩ce
Dammam, Saudi Arabia
T +966 13 510 3702
Chile Sales O󰀩ce
Las Condes
T +56 2928 4819
India Sales O󰀩ce
Chennai
T +91 44 3919 7300
Korea Sales O󰀩ce
Seoul
T +82 2 3483 1555
Asia Pacic
EGS Private Ltd.
Block 4008, Ang Mo Kio
Ave 10,
#04-16 TechPlace 1,
Singapore 569625
T +65 6556 1100
Latin America
EGS Comercializadora
Mexico S de RL de CV
Calle 10 N°145 Piso 3
Col. San Pedro de los Pinos
Del. Álvaro Obregon
Ciudad de México. 01180
T +52 55 5809 5049

Other Emerson Industrial Equipment manuals

Emerson FISHER T208 Series User manual

Emerson

Emerson FISHER T208 Series User manual

Emerson FISHER Yarway AT-13/23 Operating instructions

Emerson

Emerson FISHER Yarway AT-13/23 Operating instructions

Emerson Penberthy Manual

Emerson

Emerson Penberthy Manual

Emerson Rosemount 3051S Series User manual

Emerson

Emerson Rosemount 3051S Series User manual

Emerson Bettis RTS User manual

Emerson

Emerson Bettis RTS User manual

Emerson YARWAY CT150 Series Manual

Emerson

Emerson YARWAY CT150 Series Manual

Emerson Yarway Manual

Emerson

Emerson Yarway Manual

Emerson RIDGID MR-10 User manual

Emerson

Emerson RIDGID MR-10 User manual

Emerson YARWAY 460D3 Series Operation and maintenance manual

Emerson

Emerson YARWAY 460D3 Series Operation and maintenance manual

Emerson CC200 User manual

Emerson

Emerson CC200 User manual

Emerson Fisher ATST Desuperheater User manual

Emerson

Emerson Fisher ATST Desuperheater User manual

Emerson AVENTICS User manual

Emerson

Emerson AVENTICS User manual

Emerson Fisher Enviro-Seal Series User manual

Emerson

Emerson Fisher Enviro-Seal Series User manual

Emerson AVENTICS NL1 User manual

Emerson

Emerson AVENTICS NL1 User manual

Emerson Rosemount 405 User manual

Emerson

Emerson Rosemount 405 User manual

Emerson EN-DFA Series User manual

Emerson

Emerson EN-DFA Series User manual

Emerson AVENTICS User manual

Emerson

Emerson AVENTICS User manual

Emerson 581 Series Installation instructions

Emerson

Emerson 581 Series Installation instructions

Emerson AS1-ACC Series Installation instructions

Emerson

Emerson AS1-ACC Series Installation instructions

Emerson ACC/ARTM-7221/FC User manual

Emerson

Emerson ACC/ARTM-7221/FC User manual

Emerson SolaHD STC-SLAC Series User manual

Emerson

Emerson SolaHD STC-SLAC Series User manual

Emerson Rosemount 975 User manual

Emerson

Emerson Rosemount 975 User manual

Emerson Machinery Health PR 9350 User manual

Emerson

Emerson Machinery Health PR 9350 User manual

Emerson Liebert eXL User manual

Emerson

Emerson Liebert eXL User manual

Popular Industrial Equipment manuals by other brands

360 Y-DROP Replacement instructions

360

360 Y-DROP Replacement instructions

SAS Stampex 6+ instruction manual

SAS

SAS Stampex 6+ instruction manual

Sambo SBWG Series operating instructions

Sambo

Sambo SBWG Series operating instructions

GIGAIPC QBiX-APLA4200H-A1 quick start guide

GIGAIPC

GIGAIPC QBiX-APLA4200H-A1 quick start guide

Pepperl+Fuchs VisuNet FLX quick start guide

Pepperl+Fuchs

Pepperl+Fuchs VisuNet FLX quick start guide

Nidec LEROY-SOMER LSA 49.1 IC6 Installation and Maintenance

Nidec

Nidec LEROY-SOMER LSA 49.1 IC6 Installation and Maintenance

Wilo EMUport FTS MG Series Installation and operating instructions

Wilo

Wilo EMUport FTS MG Series Installation and operating instructions

Baileigh Industrial TN-400 Operator's manual

Baileigh Industrial

Baileigh Industrial TN-400 Operator's manual

Jäger Z80-H536.08 S8RVW3 manual

Jäger

Jäger Z80-H536.08 S8RVW3 manual

Hix R2R owner's manual

Hix

Hix R2R owner's manual

ABB HT609161 Operation manual

ABB

ABB HT609161 Operation manual

Vimpex hydrosense HSHWI-100 installation instructions

Vimpex

Vimpex hydrosense HSHWI-100 installation instructions

Trelleborg OLS user manual

Trelleborg

Trelleborg OLS user manual

NetterVibration VAC 8 Assembly and operating instructions

NetterVibration

NetterVibration VAC 8 Assembly and operating instructions

Bettersafe Weight Angel Installation & user manual

Bettersafe

Bettersafe Weight Angel Installation & user manual

SCHUNK ROTA TP Assembly and operating manual

SCHUNK

SCHUNK ROTA TP Assembly and operating manual

SCHUNK OPUS-V Series operating manual

SCHUNK

SCHUNK OPUS-V Series operating manual

ABB HT607123 Operation manual

ABB

ABB HT607123 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.