English – June 2011 167D Series
Maximum Operating Inlet Pressure(1)
Types 167D and 167DS: 27,6 bar / 400 psig
Types 167DA and 167DAS: 8,6 bar / 125 psig
Types 167DA and 167DAS (NACE): 6,9 bar / 100 psig
Maximum Diaphragm Pressure(1)
10,3 bar / 150 psig over outlet pressure setting
up to a maximum of 17,2 bar / 250 psig
Proof Test Pressure
All Pressure Retaining Components have been
proof tested per Directive 97/23/EC - Annex 1,
Section 7.4
Temperature Capabilities(1)
Nitrile (NBR)
Standard Service (Types 167D and 167DA only):
-29° to 82°C / -20° to 180°F
Low Temperature Service (Types 167D and 167DA
only) and Standard Service (Types 167DS and
167DAS only): -40° to 82°C / -40° to 180°F
Fluorocarbon (FKM)
High Temperature Service: -18° to 149°C /
0° to 300°F
Installation
!
WARNING
Only qualied personnel should install
or service a switching valve. Switching
valves should be installed, operated,
and maintained in accordance with
international and applicable codes and
regulations, and Emerson Process
Management Regulator Technologies,
Inc. instructions.
If the switching valve vents uid
or a leak develops in the system, it
indicates that service is required.
Failure to take the switching valve out
of service immediately may create a
hazardous condition.
Personal injury, equipment damage,
or leakage due to escaping uid or
bursting of pressure-containing parts
may result if this switching valve is
overpressured or is installed where
service conditions could exceed the
limits given in the Specications
section, or where conditions exceed
any ratings of the adjacent piping or
piping connections.
Introduction
This installation guide provides instructions for
installation, startup, and adjustment. To receive a copy
of the instruction manual, contact your local Sales
Ofce or view a copy at www.sherregulators.com.
For further information refer to: Type 167D Series
Instruction Manual, Form 5859, D103234X012.
P.E.D. Category
This product may be used as a safety accessory
with pressure equipment in the following Pressure
Equipment Directive 97/23/EC categories. It may
also be used outside of the Pressure Equipment
Directive using sound engineering practice (SEP)
per table below.
PRODUCT SIZE CATEGORIES FLUID TYPE
1/4 or 1/2 NPT SEP 1
Specications
Available Congurations
Types 167D and 167DS: Two-way
switching valves
Types 167DA and 167DAS: Three-way
switching valves
Body Size, Inlet and Outlet Connection Style
Ports A and C: 1/4 or 1/2 NPT
Vent and Control Pressure Connections
(Port D) and Port B: 1/4 NPT
Outlet Pressure Ranges(1)
Types 167D and 167DS (Two-Way
Switching Valves):
Port A as Inlet:
0,21 to 1,0 bar / 3 to 15 psig(2)
0,34 to 1,4 bar / 5 to 20 psig
0,34 to 2,4 bar / 5 to 35 psig
1,7 to 4,1 bar / 25 to 60 psig
2,8 to 8,6 bar / 40 to 125 psig
3,4 to 10,3 bar / 50 to 150 psig(3)
Types 167DA and 167DAS (Three-Way
Switching Valves):
Port A or C as Inlet:
0,97 to 1,4 bar / 14 to 20 psig
1,1 to 2,4 bar / 16 to 35 psig
1,7 to 4,1 bar / 25 to 60 psig
2,8 to 8,6 bar / 40 to 125 psig
Port B as Inlet:
0,48 to 1,4 bar / 7 to 20 psig
0,69 to 2,1 bar / 10 to 30 psig
1,7 to 3,4 bar / 25 to 50 psig
2,8 to 6,2 bar / 40 to 90 psig
1. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.
2. For Type 167D only
3. For Type 167DS only.
2
167D Series
To avoid such injury or damage,
provide pressure-relieving or pressure-
limiting devices (as required by
the appropriate code, regulation,
or standard) to prevent service
conditions from exceeding limits.
Additionally, physical damage to
the switching valve could result in
personal injury and property damage
due to escaping uid. To avoid
such injury and damage, install the
switching valve in a safe location.
Clean out all pipelines before installation of the
switching valve and check to be sure the switching
valve has not been damaged or has collected
foreign material during shipping. For NPT bodies,
apply pipe compound to the external pipe threads.
Install the switching valve in any position desired,
unless otherwise specied, but be sure ow through
the body is in the direction indicated by the arrow on
the body.
Note
It is important that the switching valve
be installed so that the vent hole in
the spring case is unobstructed at all
times. For outdoor installations, the
switching valve should be located
away from vehicular trafc and
positioned so that water, ice, and other
foreign materials cannot enter the
spring case through the vent. Avoid
placing the switching valve beneath
eaves or downspouts, and be sure it is
above the probable snow level.
Overpressure Protection
The recommended pressure limitations are stamped
on the switching valve nameplate. Some type of
overpressure protection is needed if the actual inlet
pressure exceeds the maximum operating outlet
pressure rating. Overpressure protection should
also be provided if the switching valve inlet pressure
is greater than the safe working pressure of the
downstream equipment.
Switching valve operation below the maximum
pressure limitations does not preclude the possibility
of damage from external sources or debris in the
line. The switching valve should be inspected for
damage after any overpressure condition.
*Recommended spare part.
Startup
The switching valve is factory set at approximately
the midpoint of the spring range or at the pressure
setting specied on the order. The allowable spring
range is stamped on the nameplate. If a pressure
setting other than specied is desired, be sure to
change the pressure setting by following the proper
procedure as mentioned in the Adjustment section.
With proper installation completed and relief valves
properly adjusted, slowly open the upstream and
downstream shut-off valves.
Adjustment
If outlet pressure adjustment is necessary, monitor
outlet pressure with a gauge during the adjustment
procedure. The switching valve is adjusted by
loosening the hex nut, if used, and turning the
adjusting screw or handwheel clockwise to increase
or counterclockwise to decrease the outlet pressure
setting. Retighten the hex nut to maintain the
adjustment position.
Taking Out of Service (Shutdown)
!
WARNING
To avoid personal injury resulting from
sudden release of pressure, isolate
the switching valve from all pressure
before attempting disassembly.
Parts List
167D Series
Key Description
1 Body
3 Flange Screw
7 Spring Case Assembly
11 Valve Stem
12*Valve Spring
14*O-ring (Spring Retainer)
15 Soft Seat (for Types 167D and 167DS only)
16*Diaphragm Assembly
17 Control Spring
18 Adjusting Screw
19 Hex Nut
20 Upper Spring Seat
23 1/4 NPT Pipe Plug
30 NACE Tag (not shown)
31 Panel Mounting Nut
32 Wire Seal (not shown)
33 Closing Cap
45 Screen Vent (for Types 167DS and 167DAS only)
48 Spring Retainer
50*O-ring (Stem and Plug)
57 Valve Plug
58*Seat
64 Retaining Ring
3
167D Series
Figure 2. Type 167DA Assembly
Figure 3. Type 167DS Assembly
Figure 1. Type 167D Assembly
B
B
23
APPLY LUBBRICANT (L)
18
19
20
17
15
50
14
57
7
16
3
50
11
58
1
48
12
A
GE37632 SECTION B-B
L
L
L
L
L
18
19
20
16
11
50
12
48
7
17
3
50
1
58
14
57
58
A
L
L
L
L
L
64
DETAIL A
64
SECTION B-B
GF02289_B
APPLY LUBBRICANT (L)
DETAIL A
APPLY LUBRICANT (L)
GE37724
SECTION B-B
23
BB
23
B
B
64
DETAIL A
18
19
20
17
45
16
1
15
11
50
12
33
7
3
50
58
57
14
48
A
L
L
L
L
The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls, Inc.,
a business of Emerson Process Management.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties
or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specications
of such products at any time without notice.
Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any
Emerson Process Management product remains solely with the purchaser.
©Emerson Process Management Regulator Technologies, Inc., 2010, 2011; All Rights Reserved
Industrial Regulators
Emerson Process Management
Regulator Technologies, Inc.
USA - Headquarters
McKinney, Texas 75069-1872, USA
Tel: +1 800 558 5853
Outside U.S. +1 972 548 3574
Asia-Pacic
Shanghai 201206, China
Tel: +86 21 2892 9000
Europe
Bologna 40013, Italy
Tel: +39 051 419 0611
Middle East and Africa
Dubai, United Arab Emirates
Tel: +971 4811 8100
Natural Gas Technologies
Emerson Process Management
Regulator Technologies, Inc.
USA - Headquarters
McKinney, Texas 75069-1872, USA
Tel: 1 800 558 5853
Outside U.S. 1 972 548 3574
Asia-Pacic
Singapore 128461, Singapore
Tel: +65 6777 8211
Europe
Bologna 40013, Italy
Tel: +39 051 419 0611
Gallardon 28320, France
Tel: +33 2 37 33 47 00
TESCOM
Emerson Process Management
Tescom Corporation
USA - Headquarters
Elk River, Minnesota 55330-2445, USA
Tel: +1 763 241 3238
+1 800 447 1250
Europe
Selmsdorf 23923, Germany
Tel: +49 38823 31 287
Asia-Pacic
Shanghai 201206, China
Tel: +86 21 2892 9499
167D Series
For further information visit www.sherregulators.com
Figure 4. Type 167DAS Assembly
DETAIL A
APPLY LUBRICANT (L)
GE37725_B
SECTION B-B
Figure 6. Optional Closing Cap
(Only Available with the 1/4 NPT Spring Case Vent)
Figure 7. Detail of Diaphragm Assembly (Key 16)
T14119_B
Figure 5. Optional Panel Mount
64
33
18
18
19
19
33
31
7
20
17
45
1
16
11
14
12
19
18
3
50
58
50
57
58
48
A
L
L
L
L
BB
23
RETAINING RING
LOWER SPRING
SEAT
DIAPHRAGM
HEAD
PUSHER POST
(TYPES 167DA AND 167DAS)
PUSHER POST
(TYPES 167D AND 167DS)
DIAPHRAGM

Other Emerson Industrial Equipment manuals

Emerson Penberthy Manual

Emerson

Emerson Penberthy Manual

Emerson Liebert eXL User manual

Emerson

Emerson Liebert eXL User manual

Emerson Digistart CS User manual

Emerson

Emerson Digistart CS User manual

Emerson FB2100 Parts list manual

Emerson

Emerson FB2100 Parts list manual

Emerson CASH VALVES Manual

Emerson

Emerson CASH VALVES Manual

Emerson SolaHD SCM-W-HRT7 User manual

Emerson

Emerson SolaHD SCM-W-HRT7 User manual

Emerson PACSystems VersaSafe IC220SDL963 User manual

Emerson

Emerson PACSystems VersaSafe IC220SDL963 User manual

Emerson AVENTICS User manual

Emerson

Emerson AVENTICS User manual

Emerson Rosemount 3051S Series User manual

Emerson

Emerson Rosemount 3051S Series User manual

Emerson Yarway Manual

Emerson

Emerson Yarway Manual

Emerson TESCOM 44-1300 Series User manual

Emerson

Emerson TESCOM 44-1300 Series User manual

Emerson Rosemount 975 User manual

Emerson

Emerson Rosemount 975 User manual

Emerson AS2-ACC Series Installation instructions

Emerson

Emerson AS2-ACC Series Installation instructions

Emerson Yarway Manual

Emerson

Emerson Yarway Manual

Emerson CAD Installation instructions

Emerson

Emerson CAD Installation instructions

Emerson Aventics G3 Series User manual

Emerson

Emerson Aventics G3 Series User manual

Emerson Fisher DFA User manual

Emerson

Emerson Fisher DFA User manual

Emerson FB3000 User manual

Emerson

Emerson FB3000 User manual

Emerson AS3-ACD Series User manual

Emerson

Emerson AS3-ACD Series User manual

Emerson B302 Manual

Emerson

Emerson B302 Manual

Emerson Fisher Enviro-Seal Series User manual

Emerson

Emerson Fisher Enviro-Seal Series User manual

Emerson PENBERTHY Series Manual

Emerson

Emerson PENBERTHY Series Manual

Emerson Penberthy Manual

Emerson

Emerson Penberthy Manual

Emerson Fisher ENVIRO-SEAL User manual

Emerson

Emerson Fisher ENVIRO-SEAL User manual

Popular Industrial Equipment manuals by other brands

Rotary RWC1200 Leverless Pro Operation & maintenance manual

Rotary

Rotary RWC1200 Leverless Pro Operation & maintenance manual

IMET VTF 500 INSTRUCTION MANUAL, MAINTENANCE AND SPARE PARTS

IMET

IMET VTF 500 INSTRUCTION MANUAL, MAINTENANCE AND SPARE PARTS

SMC Networks LVD Series manual

SMC Networks

SMC Networks LVD Series manual

Dungs HeatEngine HEPM-P Series installation instructions

Dungs

Dungs HeatEngine HEPM-P Series installation instructions

Zimmer GEH8000 Series Installation and operating instructions

Zimmer

Zimmer GEH8000 Series Installation and operating instructions

Zimmer GEP2006IL-03-B Installation and operating instructions

Zimmer

Zimmer GEP2006IL-03-B Installation and operating instructions

Edge Scout 320 manual

Edge

Edge Scout 320 manual

Thiele Streamfeeder Value Series manual

Thiele

Thiele Streamfeeder Value Series manual

XPOtool 50671 Operation manual

XPOtool

XPOtool 50671 Operation manual

Elektro-Automatik Sibo SZB SE 33U installation guide

Elektro-Automatik

Elektro-Automatik Sibo SZB SE 33U installation guide

CLEAN ROOM DEVICES CRD202 Operation manual

CLEAN ROOM DEVICES

CLEAN ROOM DEVICES CRD202 Operation manual

Frontier SA20F Owner's/operator's manual

Frontier

Frontier SA20F Owner's/operator's manual

Witt ECO 2-L Installation and operating instructions

Witt

Witt ECO 2-L Installation and operating instructions

Panasonic EXC28CE quick start guide

Panasonic

Panasonic EXC28CE quick start guide

ABB XAC25025 Operation manual

ABB

ABB XAC25025 Operation manual

Canon Die Bonder BESTEM-D01 manual

Canon

Canon Die Bonder BESTEM-D01 manual

Graco PR-X Setup - Operation - Repair

Graco

Graco PR-X Setup - Operation - Repair

Hasler HJOG 100 operating guide

Hasler

Hasler HJOG 100 operating guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.