Emerson RXi User manual

Quick Start Guide
GFK-3073B
Nov 2019
RXi –Web Panel

2
Caution Notes as Used in this Publication
Caution
Caution notices are used where equipment might be damaged if care is not taken.
Notes: Notes merely call attention to information that is especially significant to understanding and operating the equipment.
These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency
to be met during installation, operation, and maintenance. The information is supplied for informational purposes only, and
Emerson makes no warranty as to the accuracy of the information included herein. Changes, modifications, and/or
improvements to equipment and specifications are made periodically and these changes may or may not be reflected herein.
It is understood that Emerson may make changes, modifications, or improvements to the equipment referenced herein or to
the document itself at any time. This document is intended for trained personnel familiar with the Emerson products
referenced herein.
Emerson may have patents or pending patent applications covering subject matter in this document. The furnishing of this
document does not provide any license whatsoever to any of these patents.
Emerson provides the following document and the information included therein as-is and without warranty of any kind,
expressed or implied, including but not limited to any implied statutory warranty of merchantability or fitness for particular
purpose.

Quick Start Guide Contents
GFK-3073B Nov 2019
Contents 3
Table of Contents
Section 1: Specifications and Physical Characteristics...................... 4
1.1 Specifications .....................................................................................................4
1.2 Technical Drawings & Dimensions.....................................................................6
1.3 Regulatory Information.....................................................................................11
Section 2: Initial Setup ................................................................... 12
2.1 Environmental Conditions ................................................................................12
2.2 Intended Use....................................................................................................12
2.3 Jumpers and Connectors Locations.................................................................12
2.3.1 Setting Jumper Functions .........................................12
2.3.2 Socket Description ..............................................13
2.3.2.1Connecting Input Power (24V DC-in).................................................................13
2.4 LED Indicators..................................................................................................16
2.4.1 Operation Status LEDs (Screen) ....................................16
2.4.2 Ethernet Port Operation LEDs .....................................17
Section 3: Software Installation ..................................................... 18
3.1 Installation Pictures..........................................................................................18
3.2 Chromium Password Settings..........................................................................19
Section 4: Mounting Information................................................... 21
4.1 Panel Mount .....................................................................................................21
4.1.1 Panel Mount Installation Steps ....................................22
4.2 Mounting to Modular Display............................................................................23
4.3 VESA Mount.....................................................................................................26
Section 5: Product Revision History ............................................... 29

Quick Start Guide
Section 1
GFK-3073B Nov 2019
Specifications and Physical Characteristics 4
Section 1: Specifications and Physical Characteristics
1.1 Specifications
Display Size
7"
10"
12"
15"
19"
24"
Display
Resolution
1024 x 600
WSVGA
1280 x 800 WXGA
1920 x 1080
Full HD
Format
Widescreen
(16:10)
Widescreen
(16:9)
Orientation
Landscape
Reading Angle (°)
150 (H) / 145
(V)
170 (H) / 170
(V)
176 (H) / 176
(V)
170 (H) / 170
(V)
178 (H) / 178 (V)
Display Off-Color
Black
Contrast
800:1
1000:1
800:1
1000:1
5000:1
Brightness (cd/m2)
500
(1000 with Outdoor SLR Screen)
400
(1000 with
Outdoor SLR
Screen)
450
(1000 with
Outdoor SLR
Screen)
350
300
MTBF Backlighting
50 000 h (at 25°C)
Backlight
LED, Dimmable via Software
Processor
i.MX
6DualLite
Processor
Freescale i.MX 6DualLite
# of cores/TDP
2 core/2.5W
CPU frequency
1.0Ghz
Memory
Capacity
2GB DDR3L
Storage
Internal
4GB eMMC NAND Flash Memory
Operating
Control
Method
Touch
Touchscreen
Technology
Projected Capacitive Touch (PCT/PCAP)
Touch Sensor
Multi-touch (Ten-Point)
Interfaces
Port 1
1 x 10/100/1000 Base T Ethernet RJ45
Port 2
1 x RS-232/422/485 COM Port (DB-9 connector)
Port 3
1 x USB 2.0 (Type-A)
1 x USB OTG (micro USB)
Status
Indicators
Front Bezel Tri-color
LED
Amber/Green/Red
On-board Buzzer
Yes (85dB sound level with 80mA mean current)
Power-Supply
Voltage [V]
+24VDC ±20% (19.2 V to 28.8 V, 3-Pin Connector, use 28-14AWG
(0.2-1.5mm²) wire rated 90C, 1.7 in-lbs (0.19Nm) torque)
Protection-
Class/
Installation
Front-Side
IP66 Type 4/Type 4X (when mounted to flat surface of
a suitably rated enclosure)
Back-Side
IP20/Open Type product for mounting in an ultimate
enclosure Pollution Degree 2 environment
OS
Linux kernel 4.9.88: Yocto

Quick Start Guide
Section 1
GFK-3073B Nov 2019
Specifications and Physical Characteristics 5
Display Size
7"
10"
12"
15"
19"
24"
Operating
System
Framework
Embedded Linux
Software Tools
Tool 1
Chromium/Firefox Web Browser
Tool 2
HTML5 Capability
Display Size
7"
10"
12"
15"
19"
24"
Secure &
Trusted
Boot
Item 1
CAAM
Design
Housing
Aluminum Die Casting (Front)
Construction Type
Modular (Detachable Modules; Computer, Monitor, Touch Display, DIO)
Cooling
Natural Convection (Fanless Passive Cooling)
Environment
Operating Temperature
-20°C to +65°C
Storage Temperature
-30°C to +70°C
Operating Humidity
85% RH (non- condensing) @ 30°C
Operating Altitude
10000 f t. (3.000 m)
Vibration
1Grms / 5 ~ 500Hz (Random) / Operation IEC 60068-2-64
10G peak acceleration (11ms duration)/operation IEC 60068-2-27
Mounting
Panel Cutout
Dimensions
(W x H)
183.5 x
128.5 mm
255.5 x 174
mm
317 x 214.5
mm
398 x 245.5
mm
482 x 297 mm
581 x 360
mm
VESA Mounting
100 x 100
Hardware Included
Mounting Clamps and Allen Screws
Physical
Specification
Net Weight (kg)
2.0
2.6
3.8
5.1
6.9
9.0
Dimensions (W x H x D)
192 x 137 x
65 mm
267 x 186.2 x
65 mm
329.1 x 226.8
x 66 mm
410.2 x 257.6
x 65 mm
500 x 315 x
70 mm
600 x 382 x
71 mm

Quick Start Guide
Section 1
GFK-3073B Nov 2019
Specifications and Physical Characteristics 6
1.2 Technical Drawings & Dimensions
Figure 1.1: Dimensions of 7”

Quick Start Guide
Section 1
GFK-3073B Nov 2019
Specifications and Physical Characteristics 7
Figure 1.2: Dimensions of 10”

Quick Start Guide
Section 1
GFK-3073B Nov 2019
Specifications and Physical Characteristics 8
Figure 1.3: Dimensions of 12”

Quick Start Guide
Section 1
GFK-3073B Nov 2019
Specifications and Physical Characteristics 9
Figure 1.4: Dimensions of 15”

Quick Start Guide
Section 1
GFK-3073B Nov 2019
Specifications and Physical Characteristics 10
Figure 1.5: Dimensions of 19”

Quick Start Guide
Section 1
GFK-3073B Nov 2019
Specifications and Physical Characteristics 11
Figure 1.6: Dimensions of 24”
1.3 Regulatory Information
The FCC requires the following note to be published according to the FCC guidelines:
NOTE: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
•Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
Industry Canada requires the following to be published: CAN ICES-3 (A)/NMB-3 (A)
Caution

Quick Start Guide Section 2
GFK-3073B Nov 2019
Initial Setup 12
Section 2: Initial Setup
2.1 Environmental Conditions
Environmental conditions as identified in Section 1.1 shall be followed during installation and operation.
2.2 Intended Use
The RXi Web Panel is intended for use in industrial environments only. Adherence to supplied documentation
is part of the intended use. Installation, commissioning, and maintenance shall be carried out by qualified
personnel.
2.3 Jumpers and Connectors Locations
2.3.1 Setting Jumper Functions
Before installing the Web Panel, please set the necessary functions following the chart below.
Note: To determine Pin 1 of the jumper and port, please observe the marking beside the plug. it will be marked
as “1”, a bolded line or a “△”; see the welding plate at back side, the square welding plate is Pin 1.
(1) Setting Jumper Functions (SW1)
SW1: 2bit switching ON/OFF, used to set the recording and the starting mode of the Motherboard.
SW1
ON
OFF
1.BOOT_MODE1_S
DOWNLOAD MODE
NORMAL MODE
2.BOOT_DEV
SD
DEFAULT
Figure 2.1: Jumper Function (SW1)

Quick Start Guide Section 2
GFK-3073B Nov 2019
Initial Setup 13
2.3.2 Socket Description
2.3.2.1 Connecting Input Power (24V DC-in)
To connect to power, follow these steps:
1. Verify that the power cable is not energized.
2. Loosen the screw clamps on the mating power connector.
3. Strip the insulation from the power cables.
4. Secure the power cable to the mating connector, noting polarity, and tighten the screw clamps. The
torque for the attaching screws is 0.3 Nm (2.26 in-lb).
5. Apply dc power to the unit. During normal startup and operation, the LED status indicator displays as
follows:
•Solid amber while the RXi - Industrial Display unit is starting up
•Solid green during normal operation
6. Once power is applied, the unit begins initializing. The first thing to display is the splash screen.
Be sure to connect a DC power cord to this 3-pin power connector. Using a voltage out of the range may fail
to boot the system or cause damage to the system board.
Before connecting the Web Panel to other devices, please read this manual carefully first to prevent damage
to the Motherboard.
(1) Power Socket (DC_IN1)
DC_IN1: (Conn. Header Socket, 3.5mm, 1 x 3PIN), used to provide 24V voltage for the system.
DC_IN1 Pin#
Signal
Pin1
FG
Pin2
DC_IN-
Pin3
DC_IN+

Quick Start Guide Section 2
GFK-3073B Nov 2019
Initial Setup 14
Figure 2.2: Power Socket (DC_IN1)
(2) USB Socket (USB_OTG1/USB1)
USB_OTG1: Conn. Micro-USB, B-Type Female, SMD-5P With DIP 4pin, used to load system firmware
Figure 2.3: USB, LAN, and COM Ports
USB_OTG1 Pin#
Signal Name
1
5V_USB_OTG
2
USB_OTG_DN
3
USB_OTG_DP
4
USB0_ID
5
GND
USB1: Type A connector, supports USB Host.
USB1 Pin#
Signal Name
1
5V_USB_HOST1
2
USBDN_DM1
3
USBDN_DP1
4
GND

Quick Start Guide Section 2
GFK-3073B Nov 2019
Initial Setup 15
(3) LAN Socket (LAN1)
LAN 1: Conn. I/O Port, RJ45, 1000M, provide a solid RJ45 Ethernet Dock.
(4) Connecting Socket (COM1)
COM1: Conn. I/O Port, DB9, Male. Standard DB9 port, provide 1 route for RS232/422/485.
COM1 Pin#
RS232
RS422
RS485
1
NC
TXD-
DATA-
2
RXD
TXD+
DATA+
3
TXD
RXD+
NC
4
NC
RXD-
NC
5
GND
NC
NC
6
NC
NC
NC
7
NC
NC
NC
8
NC
NC
NC
9
NC
NC
NC

Quick Start Guide Section 2
GFK-3073B Nov 2019
Initial Setup 16
(5) Debug Socket (DEBUG1)
DEBUG1: Conn. 1.25mm, (DF14 with pointing) SMD-4P, use for debugging information.
DEBUG Pin#
Signal Name
1
3P3V_S0_IO
2
UART1_TXD_DEBUG
3
UART1_RXD_DEBUG
4
GND
(6) SD-Card Socket (SD1)
SD1: Socket, Micro SD/TF Card, 9pin, SMD, supports Micro SD/TF Card devices.
(7) BAT1 Socket (BAT1)
BAT1: BAT Socket, BS-10-A1B0J001, 20mm SMT, supports non-chargeable batteries. CR-2032
(8) Backlight Board Socket (BTB_MAIN_TB572B_1)
BTB_MAIN_TB-572B_1: Conn. Female, WCON, 2243-225M3CUT, 2 x 25P, 2.00mm, 180°, H=4.35, 10u”, SMD-
50P, TB-572B Backlight Board Socket.
2.4 LED Indicators
2.4.1 Operation Status LEDs (Screen)
All RXi Industrial Displays have a tri-color LED built into the screen that provides visual indication of the
operation status.
LED State
System State
Amber, Solid
Operating system starting
Green, Solid
Normal operating state
Red, Blinking
CPU Tj over temperature 90C
Off
Power not applied to unit

Quick Start Guide Section 2
GFK-3073B Nov 2019
Initial Setup 17
2.4.2 Ethernet Port Operation LEDs

Quick Start Guide Section 3
GFK-3073B Nov 2019
18
Section 3: Software Installation
3.1 Installation Pictures
The following images show typical screens during software installation.
The operating system for the RXi –Web Panel is Linux.
Figure 3.1: Linux
The web browsers Chromium, and Firefox are both compatible with the RXi –Web Panel.
Figure 3.2: Chromium Browser

Quick Start Guide Section 3
GFK-3073B Nov 2019
Mounting Information 19
Figure 3.3: Firefox Browser
3.2 Chromium Password Settings
The user/root default password is EMrootroot. Here are instructions to change the password.
1. Click the user password icon
2. Enter the default (old) and new password then click the “Set user password” or “Set root password”
button to submit the new password.

Quick Start Guide Section 3
GFK-3073B Nov 2019
Mounting Information 20
Other manuals for RXi
8
Table of contents
Other Emerson Touch Panel manuals

Emerson
Emerson Site Supervisor 10.1 User manual

Emerson
Emerson Rosemount 752 FOUNDATION User manual

Emerson
Emerson RXi User manual

Emerson
Emerson RXi User manual

Emerson
Emerson RXi User manual

Emerson
Emerson RXi Web Panel User manual

Emerson
Emerson RXi User manual

Emerson
Emerson Rosemount 752 User manual

Emerson
Emerson GFK-3072D User manual

Emerson
Emerson Rosemount 751 User manual