6 Connection wiring 7 Connection wiring
8 Conguration 9 LED operation
Specication Regulatory information
©2022 EMS Ltd. All rights reserved. Page 2 of 2 TSD142-99 Issue 7 21/06/2022 AJM
Refer to the wireless zone
monitor engineers guide
(TSD143) for full wiring details.
Free to download from www.
emsgroup.co.uk
The ZIM must be added to the WZM, before adding other wireless devices to
the system.
• Refer to the wireless zone monitor
engineers guide (TSD143) for full
programming details.
Operating temperature -10 to +55 °C
Storage temperature 5 to 30 °C
Humidity 0 to 95% non-condensing
Supply 6x AA alkaline (Panasonic LR6AD Powerline /
Varta 4006 Industrial)
CAUTION!
Fitting of an incorrect battery type invalidates the product certication and may
result in poor performance.
Output rating 2A at 24 VDC
IP rating IP65
Operating frequency 868 MHz
Output transmitter power 0 to 14 dBm (0 to 25 mW)
Signalling protocol X
Dimensions (W x H x D) 120 x 240 x 60 mm
Weight 0.95 kg
Location Type A: For indoor use
Manufacturer
Year of manufacture
Certication
Certication body
CPR DoP
Approved to
European Union
Directives
0359-CPR-00436
EN54-18:2005. Fire detection and re alarm systems.
Part 18:Input/output devices.
EN54-25:2008. Incorporating corrigenda September 2010
and March 2012. Fire detection and re alarm systems.
EMS declares that this device is in compliance with Directive
2014/53/EU. The full text of the EU declaration of conformity
is available at the following internet address: www.
emsgroup.co.uk
2012/19/EU (WEEE directive): Products marked with this
symbol cannot be disposed of as unsorted municipal waste
in the European Union. For proper recycling, return this
product to your local supplier upon purchase of equivalent
new equipment, or dispose of it at designated collection
points. For more information see www.recyclethis.info
Dispose of your batteries in an environmentally friendly
manner according to your local regulations.
Carrier Manufacturing Poland Sp. z o.o.
Ul. Kolejowa 24. 39-100 Ropczyce, Poland
See devices serial number label
0905
14
• When tting / replacing batteries; observe correct polarity, using only
specied batteries.
• Connect the power jumper across the PIN header.
Free to download from
www.emsgroup.co.uk
The device has six indication LEDs. Pressing the LED enable button enables
their illumination for 10 minutes before automatically timing out.
2x input fault: YELLOW LED ON = FAULT
2x input closed: RED LED ON = ACTIVE
2x output: RED LED ON = ACTIVE
3VDCS
INPUT 1I NPUT 2
LED
NABLE
PO WER
INPUT 1
INPUT 2
FAULT
CLOSED
64
F-SAFE
IP- IP+I P- IP+
EXP
32
• Once powered, reassemble the device.
device
unpowered
(pins unlinked)
device
powered
(both pins
linked)
CLOSED
FAULT
INPUT 1
INPUT 2
Input 2
LEDs
Input 1
LEDs
Output 1 LED Output 2 LED