1Pre installation
5 Power device
3 Disassemble device
2Components
device
unpowered
(pins unlinked)
device
powered
(both pins linked)
!
Installation must conform to applicable local installation
codes and
should only be installed by a fully trained
competent person.
Ensure that the device is installed as per the site survey.
The use of a non-metallic spacer should be considered if
mounting the device on to a metal surface.
DO NOT press the log on button on a pre-programmed
device. This will cause communication with the control panel
to be lost. Should this happen, delete the device from the
system and add it back on.
This device contains electronics that may be susceptible to
damage from Electrostatic Discharge (ESD). Take appropriate
precautions when handling electronic boards.
Wireless module Mounting plate
6 Optional locking
To lock the remote indicator
into the wireless module,
remove the cut out section
as shown.
Disengage the mounting
plate by turning the wireless
module anticlockwise, whilst
pressing down the locking
pin.
Once powered, reassemble the device.
Wireless Remote Indicator Module
Installation Guide
FCX-178-001 Wireless Remote Indicator Module
FCZ-170-111 Remote Indicator Wireless Module Only
117261 Remote Indicator Only
Example shown:
Model FCX-178-001
Part no Product description
23
Remote indicator
1
When fitting / replacing batteries; observe correct polarity,
using only specified batteries.
Connect the power jumper across the PIN header.
31 2
First disengage the remote indicator from the wireless module
by turning it anticlockwise. This exposes the wireless module’s
locking pin as shown.
www.emsgroup.co.uk
Wireless Detector Base
PRESS HERE TO
LOG ON
Part No: FCZ-170-111
4 Fix mounting plate
Use all four mounting holes to ensure a firm fixing.
Use suitable fasteners and fixings.
THIS WAY UP
WHEN WALL
MOUNTING
When wall mounting, ensure the mounting plate is fitted in the
orientation shown.
www.emsgroup.co.uk
Wireless Detector Base
PRESS HERE TO
LOG ON
Part No: FCZ-170-111
Locking pin
©2021 EMS Ltd. All rights reserved Page 1 of 2 TSD116-99 Iss 5 24/11/2021 AJM
7 Configuration
The device’s loop address is configured within the user interface’s
menu structure.
Refer to the Wireless remote indicator programming instructions
(TSD115) for full programming details.
Free to download from
www.emsgroup.co.uk
Operating
temperature -10 to +55 °C
Storage
temperature 5 to 30 °C
Humidity 0 to 95% non-condensing
Supply 6x AA alkaline (Panasonic LR6AD Powerline /
Varta 4006 Industrial)
CAUTION!
Fitting of an incorrect battery type invalidates the product certification and
may result in poor performance.
IP rating IP23
Operating
frequency 868 MHz
Output
transmitter
power Auto adjusting 0 to 14 dB (0 to 25 mW)
Dimensions (Ø x D) 113 x 81 mm
Weight 0.40 kg
Location Type A: For indoor use
2012/19/EU (WEEE directive):
Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the
European Union. For proper recycling, return this
product to your local supplier upon purchase of
equivalent new equipment, or dispose of it at
designated collection points. For more information
see www.recyclethis.info
Dispose of your batteries in an environmentally
friendly manner according to your local
regulations.
European Union
directives
EMS declares that this device is in compliance with
Directive 2014/53/EU. The full text of the EU
declaration of conformity is available at the
following internet address:
www.emsgroup.co.uk
Certification
Certification body
CPR DoP 0359-CPR-00127
0905
10
Specification
E
N54-25:2008. Incorporating corrigenda September
2010 and March 2012. Fire detection and fire alarm
systems.
Part 25: Components using radio links
Approved to
Regulatory information
Manufacturer Carrier Manufacturing Polska Sp. Z o.o. Ul.
Kolejowa 24. 39-100 Ropczyce, Poland
Year of
manufacture See devices serial number label
To unlock the device, insert
a flat bladed screwdriver
into the release slot and
turn the remote indicator
anticlockwise to release, as
shown.
6 Unlocking
©2021 EMS Ltd. All rights reserved Page 2 of 2 TSD116-99 Iss 5 24/11/2021 AJM

Other manuals for FireCell FCZ-170-111

2

This manual suits for next models

2

Other EMS Control Unit manuals

EMS Fusion FCX-532-001 User manual

EMS

EMS Fusion FCX-532-001 User manual

EMS LRP2000 Series User manual

EMS

EMS LRP2000 Series User manual

EMS EC-41-0200 User manual

EMS

EMS EC-41-0200 User manual

EMS FireCellWDC User manual

EMS

EMS FireCellWDC User manual

EMS EMS520 User manual

EMS

EMS EMS520 User manual

EMS FireCell FCZ-170-111 User manual

EMS

EMS FireCell FCZ-170-111 User manual

EMS ZITON Owner's manual

EMS

EMS ZITON Owner's manual

EMS ZITON RADIO LOOP MODULE Owner's manual

EMS

EMS ZITON RADIO LOOP MODULE Owner's manual

EMS EC-41-0200 User manual

EMS

EMS EC-41-0200 User manual

EMS fusion FCX-532-001 User manual

EMS

EMS fusion FCX-532-001 User manual

Popular Control Unit manuals by other brands

System Sensor M500M Installation and maintenance instructions

System Sensor

System Sensor M500M Installation and maintenance instructions

ADDAC System ADDAC308 LIGHT TO CV Assembly guide

ADDAC System

ADDAC System ADDAC308 LIGHT TO CV Assembly guide

HOKE DV-3 quick start guide

HOKE

HOKE DV-3 quick start guide

Rational MI-2091 Modification instruction

Rational

Rational MI-2091 Modification instruction

tell Compact GSM 2 Installation and application manual

tell

tell Compact GSM 2 Installation and application manual

Vimar Elvox ECP2 Connection and operating manual

Vimar

Vimar Elvox ECP2 Connection and operating manual

Eldom Invest NHC-33 v3.0 Usage manual

Eldom Invest

Eldom Invest NHC-33 v3.0 Usage manual

Trenz Electronic TEI0015 08-C8A Series Schematics

Trenz Electronic

Trenz Electronic TEI0015 08-C8A Series Schematics

Kobelt 3329 Owner's Operation, Installation & Maintenance Manual

Kobelt

Kobelt 3329 Owner's Operation, Installation & Maintenance Manual

Aqua Environment Inc 504 Owner's operation and maintenance manual

Aqua Environment Inc

Aqua Environment Inc 504 Owner's operation and maintenance manual

Laird BTM510 user manual

Laird

Laird BTM510 user manual

Go BlueConnect manual

Go

Go BlueConnect manual

Siemens SENTRON PAC RS485 manual

Siemens

Siemens SENTRON PAC RS485 manual

Wiznet WIZ200WEB user manual

Wiznet

Wiznet WIZ200WEB user manual

National Instruments FieldPoint FP-1001 user manual

National Instruments

National Instruments FieldPoint FP-1001 user manual

Quectel SC20-CE user guide

Quectel

Quectel SC20-CE user guide

Precision PW66 user manual

Precision

Precision PW66 user manual

HB-THERM T25932-1 Assembly instructions

HB-THERM

HB-THERM T25932-1 Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.