Cambridge Wall Light
Safety Warnings
INSTRUCTION MANUAL
• Thisproductissuitableforconnectionto240V~50Hzsupply,outsideorinabathroomlocation.
• ItisrecommendedthatthislightbeinstalledbyaqualiedelectricianinaccordancewithcurrentIEEWiring
RegulationsandBuildingRegulations(PartP).
• Beforeinstallingyourlightttingalwaysswitchoffthemainssupplyandremovetheappropriatefuseor
switchofftheappropriatecircuitbreakerbeforecommencinginstallation.
• ThisisaClassItting,andmustbeconnectedtoEarth.Theterminalblocksaresuppliedaccordingto
requirementsofthetting.
• Nevertbulbsofahigherwattagethanthosespeciedonthelabel(asthesemaycauseoverheatingand
damagethetting).
• Thisproductcontainsdelicateparts.Takecareduringinstallationandmaintenancetoavoidbreakages
• Runsupplywirefroma5-ampelectricalsupplyusingdoubleinsulated3-corecableoftypeH05RN-F1.0mm2
(notsupplied)toselectedsite,ensuringitisadequatelyprotectedthroughthefulllengthofthecablerun,it
mustcomeoutoftheatsurfaceofthewallorstepsinlinewiththeentrytothetting.
• Exceptwhereinstalledinaconduitorductwhichprovidesequivalentprotectionagainstmechanicaldamage,
acableburiedinthegroundshallincorporateanearthedarmourormetalsheathorboth,suitableforuseas
aprotectiveconductor,orbeofinsulatedconcentricconstruction.Buriedcablesshallbemarkedbycable
covers or a suitable marking tape. Buried conduits and ducts shall be suitably identied. Buried cables,
conduitsandductsshallbeatasufcientdepthtoavoidbeingdamagedbyanyreasonablyforeseeable
disturbanceoftheground.
• Thislightmayalsobeinstalledin“Zones1and2andOutsideZones”ofabathroomwherewaterjetsare
notusedforcleaningpurposes.ThesezonesarereferencedinBS7671:2008“RequirementsforElectrical
Installations”,IEEWiringRegulations17thEdition.Alldimensionsmustbecheckedinconjunctionwiththe
Regulations.
• ThesupplycircuitmustbeprotectedbyanRCD.If installed in a bathroomanRCDmustbeusedORthe
casingofthelightmustbeconnectedtothe“SupplementaryEquipotentialBonding”pointsinthebathroom.
• An electrician must be consulted if in any doubt about your own competency, or meaning of “Bathroom
Zones”or“EquipotentialBonding”.
• Ifanymodicationismadeitwillinvalidatethewarrantyandmayrendertheproductunsafe.
• Iftheglassordiffuserisbrokenorcrackeditmustbereplaced,pleaseconsultyourretailer.
EndonLighting,LS90SE 56216_56217-Cambridge-WB20150908
Care Information
Allow10minutestocoolbeforereplacing,adjustingorcleaning.
Cleanwithadryclothonly.Donotuseliquidorabrasivecleanersonthisproduct.
Assembly/ User Instructions
Pleasereadtheseinstructionscarefullybeforettingandretainforreference.
Checkthepackagingandmakesurethatyouhavealltherequiredparts.
Followeachassemblystepinordertopreventincorrectassembly.
Ensurethattheproductisfullyassembledasillustratedbeforeuse.
Before you start