ENFORCER ST-BL01Q User manual

ST-BL01Q
High-Speed Latching Continuity Tester
Manual
Features:
Test N.O. and N.C. circuits
Verify circuit continuity via:
- Beeper
- Visual
Built-in LED light
Three test modes:
- Real-time
- Auto-reset
- Latch mode
Internal battery included
Note: Products with model numbers that end with “Q” or that have a round green “Q” sticker are RoHS compliant.

ENFORCER ®High-Speed Latching Continuity Tester
2SECO-LARM ®U.S.A., Inc
Introduction:
The ENFORCER ST-BL01Q High-Speed Latching Continuity Tester allows testing of continuity
over durations as low as 100µs. Excellent for troubleshooting sensitive security systems,
automotive electrical systems, and more.
Overview:
1. Indicator Switch
- LED + Beeper
- LED
- OFF (Store in this position)
2. Headlight Switch
- Turn LED light ON/OFF
3. Reset Button
- Use to reset tester while in latch
mode.
4. Headlight LED
5. Input Jack
- Do not connect to a live circuit
6. Power Indicator LED
- ON: Power on
- Flashing: Low battery
7. Test Mode Switch
- Real-time
- Auto reset
- Latch
8. Circuit Type
- N.O. for Normally Open circuits
- N.C. for Normally Closed circuits
9. Trigger LED
- When lit, circuit is continuous
Specifications:
Response time
100µs
Continuity threshold
3kΩ
Power
9-Volt battery (included)
Weight
3.5-oz (99g)
5.1-oz (144g) including 9-Volt battery
Dimensions
43/16”x3”x11/16”(105x75x27 mm)
IMPORTANT NOTES:
1. Do not perform tests on live or powered circuits. Performing tests on live or powered
circuits will damage the tester.
2. Do not use the tester to test voltage. The tester can only test continuity.
3. Always turn the tester OFF after use to prevent draining the battery. (See above)
Using the Tester:
Power LED
Low Battery
Test Mode
Beeper
Visual
Power (OFF)
Real-time
Auto-reset
Latch mode
Headlight Switch
On
Off
Circuit Type
N.O.
N.C.
Triggered
Reset Button
Latching Continuity Tester
ST-BL01Q
WARNING: DO NOT
PERFORM TESTS ON LIVE
CIRCUITS.
Set Test Mode
NOTE: Continuity must be detected for at least 100µs to trigger.
Real-time: Tester will indicate
whenever it is triggered.
Auto reset: Tester will
indicate continuously for 1
second after it is triggered.
Latch: Tester will indicate
continuously after triggered,
until reset button is pressed.
Beeper
Visual
Power (OFF)
Latch mode
Auto-reset
Real-time
Headlight Switch
WARNING: DO NOT
PERFORM TESTS ON LIVE
CIRCUITS
Set Indication Type
Beeper: When triggered,
beeper will sound and
Triggered LED will light.
Visual: When triggered,
Triggered LED will light.
Power (OFF): Always
turn tester OFF after use.
Beeper
Visual
Power (OFF)
Latch mode
Auto-reset
Real-time
Headlight Switch
WARNING: DO NOT
PERFORM TESTS ON LIVE
CIRCUITS

ENFORCER ®High-Speed Latching Continuity Tester
SECO-LARM ®U.S.A., Inc 3
Performing Tests:
WARNINGS:
- Only test unpowered circuits.
- Never operate a vehicle or other machinery while using the tester. Set the tester to latch mode and check
only after testing is completed.
1. Contacts
When experiencing trouble with a magnetic
contact such as false alarms or intermittent
operation, connect the tester at various points
in the system using latch mode while
attempting to reproduce failure conditions. This
procedure will help identify the trouble
component.
2. Vibration
Vehicle alarms, tamper switches and other devices and wiring that are exposed to frequent
vibration or bending can begin to experience fatigue, causing micro-second open circuits.
Connect the tester at various points in the system, and use the latch mode while operating the
device.
3. Shock/vibration sensors
The latching tester can simplify installation and calibration of shock and vibration sensors.
When adjusting sensitivity, use the tester in place of alarm panel or other receiving device.
When experiencing false alarms or false negatives, use the tester in latch mode at various
points in the system to detect which component is over sensitive or responding too slowly.
Set Circuit Type
N.O.: To make the tester
trigger when the circuit is
closed, select N.O. under
Circuit Type.
N.C.: To make the tester
trigger when the circuit is
open, select N.C. under
Circuit Type.
Beeper
Visual
Power (OFF)
Latch mode
Auto-reset
Real-time
Headlight Switch
WARNING: DO NOT
PERFORM TESTS ON LIVE
CIRCUITS
Usage Notes
Low Battery: Power LED will
flash to show low battery.
LED Light: Use when working
in low-light conditions.
Reset Button: Press before
performing tests and after
changing settings.
Beeper
Visual
Power (OFF)
Latch mode
Auto-reset
Real-time
Headlight Switch
WARNING: DO NOT
PERFORM TESTS ON LIVE
CIRCUITS
Magnetic Contact
Beeper
Visual
Power (OFF)
Latch mode
Auto-reset
Real-time
Headlight Switch
WARNING: DO NOT
PERFORM TESTS ON LIVE
CIRCUITS
Vibration Detector
Beeper
Visual
Power (OFF)
Latch mode
Auto-reset
Real-time
Headlight Switch
WARNING: DO NOT PERFORM
TESTS ON LIVE CIRCUITS

ENFORCER ®High-Speed Latching Continuity Tester
4SECO-LARM ®U.S.A., Inc
Installing Optional Belt Clip:
Troubleshooting:
Continuity test yields false positive
Press reset button.
Check Circuit Type is correctly set.
Continuity test yields false negative
Change the internal battery.
(Be sure to store tester in OFF mode.)
Internal battery depletes quickly
Be sure to store tester in OFF mode.
Also Available from SECO-LARM:
12/24VDC Auto-Sensing Tester
ST-BT03Q
DC Plug to Terminal Block
CA-161T
Illuminated Power Connectors
CA-1610-3FLQ / CA-1510-3FLQ
WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while
used in normal service for a period of one (1) year from the date of sale to the original consumer customer.
SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned,
transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of
God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or
faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating
properly as a result of causes other than defects in material and workmanship. The sole obligation of
SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or
consequential personal or property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication.
However, the SECO-LARM policy is one of continual development and improvement. For this reason,
SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not
responsible for misprints or typographical errors.
Copyright © 2011 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or
copied, in whole or in part, without the written permission of SECO-LARM.
SECO-LARM ®U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 E-mail: sales@seco-larm.com
1. Open the
case and
remove the
circuit board.
2. Drill two 1/4”
holes at the
guide points
as shown.
Order Part# 763-166%
MiST-BL01Q_1111.docx
PITSW1
Guide Points
3. Using the
included
screws,
attach the
belt clip.
4. Reclose the
case.
Belt Clip
Front View
Back View
Side View
Inside View
Table of contents
Other ENFORCER Test Equipment manuals
Popular Test Equipment manuals by other brands

Woodsonix
Woodsonix SB800U Operating Guide and Technical Information

Hakko Electronics
Hakko Electronics FG101B-03 instruction manual

Fluke
Fluke 4181 user guide

Hoyt
Hoyt 2734 ER instruction manual

Maddox
Maddox MH5-1 Owner's manual & safety instructions

DARKSTAR TECHNOLOGIES
DARKSTAR TECHNOLOGIES D230 Guide to Operation