2
4. Refit the battery cover by fastening its screw.
Include to or Exclude from a Z-WaveTM Network
In the rear casing, there is a link key which is used to carry out inclusion, exclusion,
reset or association. When first power is applied, its two-color LED flashes on and off
alternately and repeatedly at 2-second intervals. It implies that it has not been
assigned a node ID and cannot work with Z-Wave enabled devices. Please get
familiar with the terms below before starting the operations.
Function Description
Inclusion Add a Z-Wave enabled device (e.g. Flood Detector) to Z-Wave network.
Exclusion Delete a Z-Wave enabled device (e.g. Flood Detector) from the network.
Association After inclusion, you have to define the relationship between devices. Through
association, device can be assigned as master/slave, and specify which
slave is going to be controlled by which master.
Reset Restore Flood Detector to factory default.
The table below lists an operation summary of basic Z-Wave functions. Please refer
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
setup function, and to include/exclude/associate devices.
Function Description Audible & Visual
Indication
No node ID The Z-Wave Controller does not allocate a
node ID to the Detector. 2-second on, 2-second off
1. Have Z-Wave Controller entered
inclusion mode.
Inclusion
2. Pressing link key three times within 1.5
second will enter inclusion mode. The
detector will stay “awake” for 10
minutes to allow time for setting and
device status enquiring.
Beep once whenever link
key is pressed once.
Function Description Audible & Visual
Indication
1. Have Z-Wave Controller entered
exclusion mode.
Exclusion
2. Pressing link key three times within 1.5
second will enter exclusion mode. The
detector will stay “awake” for 10
minutes to allow time for setting and
device status enquiring.
Beep once whenever link
key is pressed once.
1. Press link key three times within 1.5
second. The detector will stay “awake”
for 10 minutes to allow time for
setting and device status enquiring.
Beep once whenever link
key is pressed once.
2. Within 1 second, press and hold the link
key until beep tone stops. Long beep for 5 seconds
Reset
3. IDs are excluded and all of preset
value will be reset to factory default. 2-second on, 2-second off
1. Have Z-Wave Controller entered
association mode.
Or Pressing link key three times within 1.5
second will enter association mode. The
detector will stay “awake” for 10
minutes to allow time for setting and
device status enquiring.
Beep once whenever link
key is pressed once.
Association
2. There are two groupings - 1 and 2. Refer
to Z-Wave’s Groups as described on
page 3 & 4.
ÚIncluding a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
ÚFailed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
Installation
Aclean smooth surface is required to mount the Flood Detector securely. The length
of flood sensor cable is 3 meters. If a 3-meter cable is too long, roll up the cable and
fasten it by twist ties. The transceiver should be placed as high up as possible on the
wall to improve communication and to prevent it from coming into contact with water in
case of flooding. After completion of battery insertion and set up, follow the below
procedures: