Observe additional system documents!
20.10.2022

General instructions
WARNING
Read the operating instructions!
The operating instructions provide an introduction to the safe use of the products.
• Read and observe the operating instructions for all system components, especially the sa-
fety instructions and warning notices!
• Observe the accident prevention regulations and any regional regulations!
• The operating instructions must be kept at the location where the machine is operated.
• Safety and warning labels on the machine indicate any possible risks.
Keep these labels clean and legible at all times.
• The machine has been constructed to state-of-the-art standards in line with any applicable
regulations and industrial standards. Only trained personnel may operate, service and re-
pair the machine.
• Technical changes due to further development in machine technology may lead to a dif-
fering welding behaviour.
In the event of queries on installation, commissioning, operation or special conditions at the
installation site, or on usage, please contact your sales partner or our customer service
department on +49 2680 181-0.
A list of authorised sales partners can be found at www.ewm-group.com/en/specialist-dealers.
Liability relating to the operation of this equipment is restricted solely to the function of the equipment. No
other form of liability, regardless of type, shall be accepted. This exclusion of liability shall be deemed ac-
cepted by the user on commissioning the equipment.
The manufacturer is unable to monitor whether or not these instructions or the conditions and methods
are observed during installation, operation, usage and maintenance of the equipment.
An incorrectly performed installation can result in material damage and injure persons as a result. For this
reason, we do not accept any responsibility or liability for losses, damages or costs arising from incorrect
installation, improper operation or incorrect usage and maintenance or any actions connected to this in
any way.
© EWM AG
Dr. Günter-Henle-Strasse 8
56271 Mündersbach Germany
Tel.: +49 2680 181-0, Fax: -244
Email: info@ewm-group.com
www.ewm-group.com
The copyright to this document remains the property of the manufacturer.
Copying, including extracts, only permitted with written approval.
The content of this document has been prepared and reviewed with all reasonable care. The information
provided is subject to change; errors excepted.
Data security
The user is responsible for backing up data of all changes from the factory setting. The user is liable for
erased personal settings. The manufacturer does not assume any liability for this.

Contents
Notes on using these operating instructions
099-500050-EW501
20.10.2022
3
1 Contents
1Contents .......................................................................................................................................... 3
2For your safety ............................................................................................................................... 5
2.1 Notes on using these operating instructions .......................................................................... 5
2.2 Explanation of icons ............................................................................................................... 6
2.3 Safety instructions .................................................................................................................. 7
2.4 Transport and installation .................................................................................................... 10
3Intended use ................................................................................................................................. 12
3.1 Applications .......................................................................................................................... 12
3.1.1 Warranty ............................................................................................................... 12
3.1.2 Declaration of Conformity ..................................................................................... 12
3.1.3 Service documents (spare parts) ......................................................................... 12
3.1.4 Part of the complete documentation ..................................................................... 13
4Product description – quick reference ...................................................................................... 14
4.1 Product variants ................................................................................................................... 14
4.2 Standard welding torch ........................................................................................................ 15
4.3 Function torch ...................................................................................................................... 16
4.3.1 Euro torch connector without control cable .......................................................... 16
4.3.2 Euro torch connector with control cable ............................................................... 17
4.4 Welding fume extractor ........................................................................................................ 17
4.4.1 Euro central connection ........................................................................................ 18
5Design and function ..................................................................................................................... 19
5.1 General ................................................................................................................................ 19
5.2 Scope of delivery ................................................................................................................. 19
5.3 Transport and installation .................................................................................................... 20
5.3.1 Ambient conditions ............................................................................................... 20
5.4 Configure welding torch ....................................................................................................... 21
5.4.1 Using the torch key ............................................................................................... 22
5.4.1.1 Contact tip ............................................................................................. 22
5.4.1.2 Contact tip holder .................................................................................. 22
5.4.2 Turning the torch neck .......................................................................................... 23
5.4.3 Changing the torch neck....................................................................................... 23
5.5 Equipment recommendations .............................................................................................. 25
5.6 Adapting the Euro torch connection on the device .............................................................. 27
5.6.1 Liner ...................................................................................................................... 27
5.6.2 Replace steel liner ................................................................................................ 27
5.6.3 Assemble the wire guide ...................................................................................... 27
5.6.3.1 Liner ...................................................................................................... 27
5.6.3.2 Guide spiral ........................................................................................... 30
5.6.4Operating elements in the machine ...................................................................... 33
5.6.5 Operating elements for the U/D / U/D X welding torch ......................................... 34
5.6.6 Operating elements for 2 U/D / 2U/D X welding torches ...................................... 34
5.6.7 Operating elements for the PC1 / PC1X welding torch ........................................ 35
5.6.7.1 Welding data display ............................................................................. 35
5.6.8 Operating elements for the PC2 / PC2X welding torch ....................................... 36
5.6.8.1 Welding data display ............................................................................. 37
6Maintenance, care and disposal ................................................................................................. 38
6.1 General ................................................................................................................................ 38
6.1.1 Identifying damage or worn components ............................................................. 38
6.1.2 Maintenance and care before each use ............................................................... 40
6.1.3 Regular maintenance ........................................................................................... 41
6.2 Disposing of equipment ....................................................................................................... 42
7Rectifying faults ........................................................................................................................... 43
7.1 Checklist for rectifying faults ................................................................................................ 43
7.2 Functional check PC1X – PC2X .......................................................................................... 44
8Technical data .............................................................................................................................. 45
8.1 MT 221G/X, MT 301G/X, MT 401G/X .................................................................................. 45

Contents
Notes on using these operating instructions
4
099-500050-EW501
20.10.2022
9Accessories .................................................................................................................................. 46
9.1 List of tools ........................................................................................................................... 46
9.2 General accessories ............................................................................................................ 46
10 Replaceable parts ......................................................................................................................... 47
10.1 MT221G ............................................................................................................................... 47
10.2 MT301G ............................................................................................................................... 48
10.3 MT401G ............................................................................................................................... 50
10.4 MT221G F ............................................................................................................................ 52
11 Circuit diagrams ........................................................................................................................... 54
11.1 MT U/D ................................................................................................................................. 54
11.2 MT U/DX............................................................................................................................... 55
11.3 MT 2U/D ............................................................................................................................... 56
11.4 MT 2U/DX............................................................................................................................. 57
11.5 MT PC1 ................................................................................................................................ 58
11.6 MT PC1X .............................................................................................................................. 59
11.7 MT PC2 ................................................................................................................................ 60
11.8 MT PC2X .............................................................................................................................. 61
12 Appendix ....................................................................................................................................... 62
12.1 Searching for a dealer .......................................................................................................... 62

For your safety
Notes on using these operating instructions
099-500050-EW501
20.10.2022
5
2 For your safety
2.1 Notes on using these operating instructions
DANGER
Working or operating procedures which must be closely observed to prevent imminent
serious and even fatal injuries.
• Safety notes include the "DANGER" keyword in the heading with a general warning symbol.
• The hazard is also highlighted using a symbol on the edge of the page.
WARNING
Working or operating procedures which must be closely observed to prevent serious
and even fatal injuries.
• Safety notes include the "WARNING" keyword in the heading with a general warning sym-
bol.
• The hazard is also highlighted using a symbol in the page margin.
CAUTION
Working or operating procedures which must be closely observed to prevent possible
minor personal injury.
• The safety information includes the "CAUTION" keyword in its heading with a general warn-
ing symbol.
• The risk is explained using a symbol on the edge of the page.
Technical aspects which the user must observe to avoid material or equipment damage.
Instructions and lists detailing step-by-step actions for given situations can be recognised via bullet
points, e.g.:
• Insert the welding current lead socket into the relevant socket and lock.

For your safety
Explanation of icons
6
099-500050-EW501
20.10.2022
2.2 Explanation of icons
Symbol
Description
Symbol
Description
Indicates technical aspects which the
user must observe.
Activate and release / Tap / Tip
Switch off machine
Release
Switch on machine
Press and hold
Incorrect / Invalid
Switch
Correct / Valid
Turn
Input
Numerical value – adjustable
Navigation
Signal light lights up in green
Output
Signal light flashes green
Time representation (e.g.: wait 4 s / ac-
tuate)
Signal light lights up in red
Interruption in the menu display (other
setting options possible)
Signal light flashes red
Tool not required/do not use
Signal light lights up in blue
Tool required/use
Signal light flashes blue

For your safety
Safety instructions
099-500050-EW501
20.10.2022
7
2.3 Safety instructions
WARNING
Risk of accidents due to non-compliance with the safety instructions!
Non-compliance with the safety instructions can be fatal!
• Carefully read the safety instructions in this manual!
• Observe the accident prevention regulations and any regional regulations!
• Inform persons in the working area that they must comply with the regulations!
Risk of injury from electrical voltage!
Voltages can cause potentially fatal electric shocks and burns on contact. Even low vol-
tages can cause a shock and lead to accidents.
• Never touch live components such as welding current sockets or stick, tungsten or wire
electrodes!
• Always place torches and electrode holders on an insulated surface!
• Wear the full personal protective equipment (depending on the application)!
• The machine may only be opened by qualified personnel!
• The device must not be used to defrost pipes!
Hazard when interconnecting multiple power sources!
If a number of power sources are to be connected in parallel or in series, only a techni-
cal specialist may interconnect the sources as per standard IEC 60974-9:2010: Installa-
tion and use and German Accident Prevention Regulation BVG D1 (formerly VBG 15) or
country-specific regulations.
Before commencing arc welding, a test must verify that the equipment cannot exceed
the maximum permitted open circuit voltage.
• Only qualified personnel may connect the machine.
• When taking individual power sources out of operation, all mains and welding current leads
must be safely disconnected from the welding system as a whole. (Hazard due to reverse
polarity voltage!)
• Do not interconnect welding machines with pole reversing switch (PWS series) or machines
for AC welding since a minor error in operation can cause the welding voltages to be com-
bined, which is not permitted.
Risk of injury due to radiation or heat!
Arc radiation can lead to skin and eye injuries.
Contact with hot workpieces and sparks can lead to burns.
• Use hand shield or welding helmet with the appropriate safety level (depends on the appli-
cation).
• Wear dry protective clothing (e.g. hand shield, gloves, etc.) in accordance with
the applicable regulations of your country.
• Persons who are not directly involved should be protected with a welding curtain or suitable
safety screen against radiation and the risk of blinding!

For your safety
Safety instructions
8
099-500050-EW501
20.10.2022
WARNING
Risk of injury due to improper clothing!
During arc welding, radiation, heat and voltage are sources of risk that cannot be
avoided. The user has to be equipped with the complete personal protective equipment
at all times. The protective equipment has to include:
• Respiratory protection against hazardous substances and mixtures (fumes and vapours);
otherwise implement suitable measures such as extraction facilities.
• Welding helmet with proper protection against ionizing radiation (IR and UV radiation) and
heat.
• Dry welding clothing (shoes, gloves and body protection) to protect against warm environ-
ments with conditions comparable to ambient temperatures of 100 °C or higher and arcing
and work on live components.
• Hearing protection against harming noise.
Explosion risk!
Apparently harmless substances in closed containers may generate excessive pressure
when heated.
• Move containers with inflammable or explosive liquids away from the working area!
• Never heat explosive liquids, dusts or gases by welding or cutting!
Fire hazard!
Due to the high temperatures, sparks, glowing parts and hot slag that occur during
welding, there is a risk of flames.
• Be watchful of potential sources of fire in the working area!
• Do not carry any easily inflammable objects, e.g. matches or lighters.
• Ensure suitable fire extinguishers are available in the working area!
• Thoroughly remove any residue of flammable materials from the workpiece prior to starting
to weld.
• Only further process workpieces after they have cooled down. Do not allow them to contact
any flammable materials!

For your safety
Safety instructions
099-500050-EW501
20.10.2022
9
CAUTION
Smoke and gases!
Smoke and gases can lead to breathing difficulties and poisoning. In addition, solvent
vapour (chlorinated hydrocarbon) may be converted into poisonous phosgene due to
the ultraviolet radiation of the arc!
• Ensure that there is sufficient fresh air!
• Keep solvent vapour away from the arc beam field!
• Wear suitable breathing apparatus if appropriate!
Noise exposure!
Noise exceeding 70 dBA can cause permanent hearing damage!
• Wear suitable ear protection!
• Persons located within the working area must wear suitable ear protection!
According to IEC 60974-10, welding machines are divided into two classes of
electromagnetic compatibility (the EMC class can be found in the Technical
data) > see 8 chapter:
Class A machines are not intended for use in residential areas where the power supply comes
from the low-voltage public mains network. When ensuring the electromagnetic compatibility of
class A machines, difficulties can arise in these areas due to interference not only in the supply
lines but also in the form of radiated interference.
Class B machines fulfil the EMC requirements in industrial as well as residential areas, inclu-
ding residential areas connected to the low-voltage public mains network.
Setting up and operating
When operating arc welding systems, in some cases, electro-magnetic interference can occur
although all of the welding machines comply with the emission limits specified in the standard.
The user is responsible for any interference caused by welding.
In order to evaluate any possible problems with electromagnetic compatibility in the
surrounding area, the user must consider the following: (see also EN 60974-10 Appendix A)
• Mains, control, signal and telecommunication lines
• Radios and televisions
• Computers and other control systems
• Safety equipment
• The health of neighbouring persons, especially if they have a pacemaker or wear a hearing
aid
• Calibration and measuring equipment
• The immunity to interference of other equipment in the surrounding area
• The time of day at which the welding work must be carried out
Recommendations for reducing interference emission
• Mains connection, e.g. additional mains filter or shielding with a metal tube
• Maintenance of the arc welding system
• Welding leads should be as short as possible and run closely together along the ground
• Potential equalization
• Earthing of the workpiece. In cases where it is not possible to earth the workpiece directly,
it should be connected by means of suitable capacitors.
• Shielding from other equipment in the surrounding area or the entire welding system
Electromagnetic fields!
The power source may cause electrical or electromagnetic fields to be produced which
could affect the correct functioning of electronic equipment such as IT or CNC devices,
telecommunication lines, power cables, signal lines and pacemakers.
• Observe the maintenance instructions > see 6 chapter!
• Unwind welding leads completely!
• Shield devices or equipment sensitive to radiation accordingly!
• The correct functioning of pacemakers may be affected (obtain advice from a doctor if nec-
essary).

For your safety
Transport and installation
10
099-500050-EW501
20.10.2022
CAUTION
Obligations of the operator!
The respective national directives and laws must be complied with when operating the
machine!
• Implementation of national legislation relating to framework directive 89/391/EEC on the int-
roduction of measures to encourage improvements in the safety and health of workers at
work and associated individual guidelines.
• In particular, directive 89/655/EEC concerning the minimum safety and health requirements
for the use of work equipment by workers at work.
• The regulations applicable to occupational safety and accident prevention in the country
concerned.
• Setting up and operating the machine as per IEC 60974.-9.
• Brief the user on safety-conscious work practices on a regular basis.
• Regularly inspect the machine as per IEC 60974.-4.
The manufacturer's warranty becomes void if non-genuine parts are used!
• Only use system components and options (power sources, welding torches, electrode hold-
ers, remote controls, spare parts and replacement parts, etc.) from our range of products!
• Only insert and lock accessory components into the relevant connection socket when the ma-
chine is switched off.
Requirements for connection to the public mains network
High-performance machines can influence the mains quality by taking current from the mains
network. For some types of machines, connection restrictions or requirements relating to the
maximum possible line impedance or the necessary minimum supply capacity at the interface
with the public network (Point of Common Coupling, PCC) can therefore apply. In this respect,
attention is also drawn to the machines' technical data. In this case, it is the responsibility of the
operator, where necessary in consultation with the mains network operator, to ensure that the
machine can be connected.
2.4 Transport and installation
WARNING
Risk of injury due to improper handling of shielding gas cylinders!
Improper handling and insufficient securing of shielding gas cylinders can cause seri-
ous injuries!
• Observe the instructions from the gas manufacturer and any relevant regulations concern-
ing the use of compressed air!
• Do not attach any element to the shielding gas cylinder valve!
• Prevent the shielding gas cylinder from heating up.

For your safety
Transport and installation
099-500050-EW501
20.10.2022
11
CAUTION
Risk of accidents due to supply lines!
During transport, attached supply lines (mains leads, control cables, etc.) can cause
risks, e.g. by causing connected machines to tip over and injure persons!
• Disconnect all supply lines before transport!
Risk of tipping!
There is a risk of the machine tipping over and injuring persons or being damaged itself
during movement and set up. Tilt resistance is guaranteed up to an angle of 10° (ac-
cording to IEC 60974-1).
• Set up and transport the machine on level, solid ground.
• Secure add-on parts using suitable equipment.
Risk of accidents due to incorrectly installed leads!
Incorrectly installed leads (mains, control and welding leads or intermediate hose pack-
ages ) can present a tripping hazard.
• Lay the supply lines flat on the floor (avoid loops).
• Avoid laying the leads on passage ways.
Risk of injury from heated coolant and its connections!
The coolant used and its connection or connection points can heat up significantly
during operation (water-cooled version). When opening the coolant circuit, escaping
coolant may cause scalding.
• Open the coolant circuit only when the power source or cooling unit is switched off!
• Wear proper protective equipment (protective gloves)!
• Seal open connections of the hose leads with suitable plugs.
The units are designed for operation in an upright position!
Operation in non-permissible positions can cause equipment damage.
• Only transport and operate in an upright position!
Accessory components and the power source itself can be damaged by incorrect connection!
• Only insert and lock accessory components into the relevant connection socket when the
machine is switched off.
• Comprehensive descriptions can be found in the operating instructions for the relevant ac-
cessory components.
• Accessory components are detected automatically after the power source is switched on.
Protective dust caps protect the connection sockets and therefore the machine against dirt and
damage.
• The protective dust cap must be fitted if there is no accessory component being operated on
that connection.
• The cap must be replaced if faulty or if lost!

Intended use
Applications
12
099-500050-EW501
20.10.2022
3 Intended use
WARNING
Hazards due to improper usage!
The machine has been constructed to the state of the art and any regulations and stand-
ards applicable for use in industry and trade. It may only be used for the welding proce-
dures indicated at the rating plate. Hazards may arise for persons, animals and material
objects if the equipment is not used correctly. No liability is accepted for any damages
arising from improper usage!
• The equipment must only be used in line with its designated purpose and by trained or
expert personnel!
• Do not improperly modify or convert the equipment!
3.1 Applications
Welding torch for arc welding machines for GMAW.
3.1.1 Warranty
For more information refer to the "Warranty registration" brochure supplied and our information regarding
warranty, maintenance and testing at www.ewm-group.com!
3.1.2 Declaration of Conformity
This product corresponds in its design and construction to the EU directives listed in the decla-
ration. The product comes with a relevant declaration of conformity in the original.
The manufacturer recommends carrying out the safety inspection according to national and in-
ternational standards and guidelines every 12 months (from commissioning).
3.1.3 Service documents (spare parts)
WARNING
No improper repairs and modifications!
To prevent injuries and damage to the machine, only competent personnel (authorised
service personnel) are allowed to repair or modify the machine.
Unauthorised manipulations will invalidate the warranty!
• Instruct competent personnel (authorised service personnel) to repair the machine.
Spare parts can be obtained from the relevant authorised dealer.

Intended use
Applications
099-500050-EW501
20.10.2022
13
3.1.4 Part of the complete documentation
This document is part of the complete documentation and valid only in combination with all other
parts of these instructions! Read and observe the operating instructions for all system
components, especially the safety instructions!
The illustration shows a general example of a welding system.
Figure 3-1
The illustration shows a general example of a welding system.
Item
Documentation
A.1
Wire feeder
A.2
Remote adjuster
A.3
Controller
A.4
Power source
A.5
Welding torch
A
Complete documentation

Product description – quick reference
Product variants
14
099-500050-EW501
20.10.2022
4 Product description – quick reference
4.1 Product variants
Version
Functions
Performance class
G
Gas-cooled
MT221, MT301, MT401
C
Interchangeable torch neck
The welding torch can be equipped with a torch neck angled
at 45°, 36° and 22°. The torch neck can be turned to the desi-
red position.
MT221, MT301
F
Fume extraction torch
The fume extraction torch features an extraction unit. The
extraction capacity is infinitely adjustable using a slider.
MT221
U/D
Up/down torch
The welding power (welding current/wire feed speed) or the
program number can be adjusted on the welding torch.
MT221, MT301, MT401
2U/D
2 up/down torch
The welding power (welding current/wire feed speed) and the
voltage correction or the JOB number and program number
can be adjusted on the welding torch.
MT221, MT301, MT401
PC1
POWERCONTROL1 welding torch
The welding power (welding current/wire feed speed) or the
program number can be adjusted on the welding torch. Values
and changes are shown on the welding torch display.
MT221, MT301, MT401
PC2
POWERCONTROL2 welding torch
The welding power (welding current/wire feed speed) and the
voltage correction or the JOB number and program number
can be adjusted on the welding torch. Values and changes
are shown on the welding torch display.
MT221, MT301, MT401
X
X technology (Multimatrix)
Welding torch with X technology – MT function torch without
separate control cable
MT221, MT301, MT401
The extended functions for MT221G...X, MT301G...X, MT401G...X welding torches are only
available if the welding torches on EWM machines are connected to the following control:
• M3.70-A Phoenix Expert
• M3.71-A Phoenix Progress
• M3.72-A alpha Q Progress
• M3.76-A Taurus Synergic S
• M3.7X-A drive 4X HP
• M3.7X-A drive 4X LP

Product description – quick reference
Standard welding torch
099-500050-EW501
20.10.2022
15
4.2 Standard welding torch
Figure 4-1
Item
Symbol
Description 0
1
Gas nozzle
2
Torch neck 45°
3
Grip plate
4
Torch trigger

Product description – quick reference
Function torch
16
099-500050-EW501
20.10.2022
4.3 Function torch
Figure 4-2
Item
Symbol
Description 0
1
Gas nozzle
2
Torch neck 45°
3
Operating elements
4
Grip plate
5
Torch trigger
4.3.1 Euro torch connector without control cable
Figure 4-3
Item
Symbol
Description 0
1
Anti-kink spring
2
Euro central connection

Product description – quick reference
Welding fume extractor
099-500050-EW501
20.10.2022
17
4.3.2 Euro torch connector with control cable
Figure 4-4
Item
Symbol
Description 0
1
Anti-kink spring
2
Euro central connection
3
Control cable plug
Only for control variant 2U/D.
Version with control cable only with control variant 2U/D.
4.4 Welding fume extractor
Figure 4-5
Item
Symbol
Description 0
1
Bypass slider, extraction capacity
2
Extraction nozzle
3
Gas nozzle
4
Torch trigger
5
Hose package
6
Anti-kink device
7
Grip plate

Product description – quick reference
Welding fume extractor
18
099-500050-EW501
20.10.2022
4.4.1 Euro central connection
Figure 4-6
Item
Symbol
Description 0
1
Connection, extraction unit
Connect to extraction device or central extraction unit
Ø = 42.5 mm
2
Anti-kink spring
3
Euro central connection

Design and function
General
099-500050-EW501
20.10.2022
19
5 Design and function
5.1 General
WARNING
Risk of injury from electrical voltage!
Contact with live parts, e.g. power connections, can be fatal!
• Observe the safety information on the first pages of the operating instructions!
• Commissioning must be carried out by persons who are specifically trained in handling
power sources!
• Connect connection or power cables while the machine is switched off!
CAUTION
Risk of injury due to moving parts!
The wire feeders are equipped with moving parts, which can trap hands, hair, clothing
or tools and thus injure persons!
• Do not reach into rotating or moving parts or drive components!
• Keep casing covers or protective caps closed during operation!
Risk of injury due to welding wire escaping in an unpredictable manner!
Welding wire can be conveyed at very high speeds and, if conveyed incorrectly, may es-
cape in an uncontrolled manner and injure persons!
• Before mains connection, set up the complete wire guide system from the wire spool to the
welding torch!
• Check wire guide at regular intervals!
• Keep all casing covers or protective caps closed during operation!
Accessory components and the power source itself can be damaged by incorrect connection!
• Only insert and lock accessory components into the relevant connection socket when the
machine is switched off.
• Comprehensive descriptions can be found in the operating instructions for the relevant ac-
cessory components.
• Accessory components are detected automatically after the power source is switched on.
Protective dust caps protect the connection sockets and therefore the machine against dirt and
damage.
• The protective dust cap must be fitted if there is no accessory component being operated on
that connection.
• The cap must be replaced if faulty or if lost!
Read and observe the documentation to all system and accessory components!
Read and observe the documentation to all system and accessory components!
5.2 Scope of delivery
The delivery is checked and packaged carefully before dispatch, however it is not possible to exclude the
possibility of damage during transit.
Receiving inspection
• Check that the delivery is complete using the delivery note!
In the event of damage to the packaging
• Check the delivery for damage (visual inspection)!
In the event of complaints
If the delivery has been damaged during transport:
• Please contact the last haulier immediately!
• Keep the packaging (for possible checking by the haulier or for the return shipment).
Packaging for returns
If possible, please use the original packaging and the original packaging material. If you have any queries
on packaging and protection during transport, please contact your supplier.

Design and function
Transport and installation
20
099-500050-EW501
20.10.2022
5.3 Transport and installation
CAUTION
Risk of accidents due to supply lines!
During transport, attached supply lines (mains leads, control cables, etc.) can cause
risks, e.g. by causing connected machines to tip over and injure persons!
• Disconnect all supply lines before transport!
5.3.1 Ambient conditions
Equipment damage due to contamination!
Unusually high amounts of dust, acids, corrosive gases or substances can damage the machine
(observe maintenance intervals > see 6.1.3 chapter).
• Avoid large amounts of smoke, steam, oily fumes, grinding dust and corrosive ambient air!
In operation
Temperature range of the ambient air:
• -10 °C to +40 °C (-13 F to 104 F) [1]
Relative humidity:
• up to 50 % at 40 °C (104 F)
• up to 90 % at 20 °C (68 F)
Transport and storage
Storage in a closed area, temperature range of the ambient air:
• -25 °C to +55 °C (-13 F to 131 F) [1]
Relative humidity
• up to 90 % at 20 °C (68 F)
[1] Ambient temperature dependent on coolant! Observe the coolant temperature range of the torch coo-
ling
Other manuals for MT221G X Series
1
This manual suits for next models
5
Table of contents
Other EWM Flashlight manuals

EWM
EWM PM 301 W User manual

EWM
EWM cool35 U31 User manual

EWM
EWM TIG 17 GD User manual

EWM
EWM AMT301G User manual

EWM
EWM MT301W X Series User manual

EWM
EWM TIG 200 GRIP GD CW User manual

EWM
EWM SPOTARC TIG 18 W User manual

EWM
EWM PHW 100 User manual

EWM
EWM MT301-451W F2 User manual

EWM
EWM MTR242W User manual