Excentr 40-25 Model 2019 -page 2 of 2 - File:Excentr40-25Krt-v1.0en.docx
EXCENTR
B.V.
Columbusweg 50
NL 4462HB GOES
Tel: +31 (0)88 1700 601
E-mail:
3. Use:
Before starting treatment with the Excentr, examine
the floor on colour and shape retention
Adjust the T-Handle position, if necessary.
Before you start, check if the correct pad for the
job is attached.
Check the ON/OFF switch is switched OFF.
Insert the extension cable in the machine plug
and in a properly grounded wall socket.
Power switch ON: the motor starts and the pad
starts working. Start moving the machine
immediately: else the floor can be damaged on
that spot.
During work the machine can moved in all
directions easily and with little force. Work in long
tracks up and down, not in short back-and-forth-
going movements.
Always turn the machine OFF immediately when
you quit working, else the floor can be damaged.
Take the plug out of the socket.
Ballast.
Experience in practice shows that, under certain
circumstances, the machine works better or faster if
there is extra
pressure on the pad:
Installation:
Place an equal
number of plates on
the left and right side
of the machine.
Fasten the plates with the star-knobs.
Removal: loosen the two knobs and remove the
plates. Always replace the star-knobs.
4. Maintenance:
Daily:
Check the cables for damage
Check the pad for wear.
After using chemical cleaning agents, clean the
machine with a moist-damp cloth in order to
avoid that chemical agents corrode any stainless
steel parts.
Check for loose bolts/nuts.
Monthly:
Check the grip surface under the pad holder if it
still has sufficient grip for the pad.
Check the vibration rubbers for tears!
Yearly:
Make sure that the mandatory safety inspection
(NEN 3140) for electrical tools is done.
Pad replacement:
The pad is attached to the eccentric plate with
Velcro. Do the following steps:
Turn off the machine.
Remove the plug from the socket.
Set the handle with T-handlebar to the highest
position.
Tilt the machine backwards so that the handlebar
is on the floor and the pad is vertical.
Pull the pad from
the eccentric plate.
Attach the new
pad carefully to the
ec-centric plate and
then push it firmly
in place.
Put the machine in upright position again.
Put the plug in the socket.
Turn the machine on and you are ready to work
again.
5. Malfunctions:
1) The machine does not start:
Check the earth leakage circuit breaker.
Check the power supply.
Check the cables for damage.
Contact your supplier.
2) The machine makes a rattling sound:
STOP IMMEDIATELY!! CHECK FIRST!!
A nut has vibrated loose from the ballast
plates. RE-TIGHTEN!!
A rubber from the pad holder is broken.
REPLACE!
The eccentric bearing is worn. REPLACE!!
There is more than this quick start paper! For missing information read the Excentr 40-25 User Manual!!