Federal RSSM360 Installation instructions

E3496
REV G 01/01/20
RSSM360, RSSD360, RSSM460, RSSD460,
RSSM560, RSSD560, RSSM660, RSSD660,
RSSM378, RSSD378, RSSM478, RSSD478,
RSSM578, RSSD578, RSSM678, RSSD678,
Self-Contained & Remote Models
Includes Drop-In & NSSM
INSTALLATION & OPERATION
INSTRUCTIONS
KEEP THIS MANUAL FOR FUTURE REFERENCE
Engineering and technical data are subject to change without notice.
FEDERAL INDUSTRIES 215 FEDERAL AVE Belleville, WI 53508
Toll Free 1(800) 356-4206 WI Phone (608) 424-3331 Fax: (608) 424-3234

CONTENTS
INTRODUCTION .............................................................................................................1
WARNING LABELS & SAFETY INSTRUCTIONS..........................................................2
PRE-INSTALLATION PROCEDURES............................................................................3
Inspection For Shipping Damage......................................................................3
INSTALLATION INSTRUCTIONS...................................................................................3
Locating The Display Case.........................................................................................3
Grill Removal..............................................................................................................3
Removing Case From Shipping Skid..........................................................................4
Removing Packaging Material ....................................................................................4
Leveling The Case......................................................................................................4
Condensate Evaporator..............................................................................................4
Lights..........................................................................................................................5
Optional Shelf Lights...................................................................................................5
ELECTRICAL CONNECTION & GROUNDING INSTRUCTIONS...................................6
Electrical Supply Wiring ....................................................................................6
Grounding Requirements.............................................................................6
Permanent Connection ................................................................................6
Cord Connection..........................................................................................7
OPERATING INSTRUCTIONS........................................................................................8
Initial Start-Up....................................................................................................8
Light Switch & Lights.........................................................................................8
Light Replacement............................................................................................8
Digital Display...........................................................................................................8
Placing Product In Case....................................................................................8
Energy Saving Night Curtain .............................................................................8
User Control RANCO ........................................................................................9
Using The Electronic Control .......................................................................9
User Control CAREL .......................................................................................10
Electronic Temperature Control .................................................................10
Powering On Control..................................................................................10
Adjusting the set point.....................................................................................11
Error Codes....................................................................................................11 & 12
Dual Pressure Control.................................................................................... 12
Shelves...........................................................................................................13
CONTROL OPERATION...............................................................................................14
Electronic Control............................................................................................14
Operation...................................................................................................14
Defrost Cycle..............................................................................................15
Control Factory Setting ..............................................................................15
Control Display................................................................................................16
Minimum Run Timer Feature ..........................................................................16
Maximum Run Timer Feature .........................................................................16

REFRIGERATION OPERATION...................................................................................16
Self-Contained Operation................................................................................16
Remote Operation...........................................................................................17
Electronic Expansion Valve..........................................................................17
Remote Condensing Units...........................................................................18
CLEANING INSTRUCTIONS ........................................................................................19
Cleaning The Condenser Filter .......................................................................19
Cleaning The Condenser Coil................................................................19 & 20
Cleaning The Condensate Pump....................................................................20
Cleaning The Acrylic Air Deflector...................................................................20
Daily Cleaning.................................................................................................21
Weekly Cleaning.............................................................................................22
DROP-IN UNITS after 01/01/20 ....................................................................................23
DROP-IN UNITS prior to 01/01/20................................................................................24
Locating Case In Counter & Counter Drop-In Cutout All Versions..................25
Counter Venting Self-Contained Units ............................................................26
Counter Base Access Self-Contained & Remote............................................26
Leveling Case .................................................................................................27
Ducting Condenser Air Intake.........................................................................27
SERVICE INFORMATION.............................................................................................28
Pre-Service Checklist ...............................................................................................29
Special Service Situations ........................................................................................30
SALE & DISPOSAL ......................................................................................................30
Owner Responsibility................................................................................................30
REFRIGERATION & ELECTRICAL DATA .............................................................................31
RSSM360 & RSSM378 - RSSD360 & RSSD378.............................................31 & 31A
RSSM460 & RSSM478 - RSSD460 & RSSD478.............................................32 & 32A
RSSM560 & RSSM578 - RSSD560 & RSSD578.............................................33 & 33A
RSSM660 & RSSM678 - RSSD660 & RSSD678.............................................34 & 34A
RSSM878 & RSSD878....................................................................................35 & 35A
REPLACEMENT PARTS.........................................................................................................36
RSSM360 & RSSM378 - RSSD360 & RSSD378.............................................36 & 36A
RSSM460 & RSSM478 - RSSD460 & RSSD478.............................................37 & 37A
RSSM560 & RSSM578 - RSSD560 & RSSD578.............................................38 & 38A
RSSM660 & RSSM678 - RSSD660 & RSSD678.............................................39 & 39A
RSSM878 & RSSD878....................................................................................40 & 40A
RSSM DISPLAY AREA & VOLUME........................................................................................41
RSSM STANDARD DEPTH CASES ..........................................................................41
RSSM SLIM PROFILE 30” DEEP ...............................................................................41
WIRING DIAGRAMS................................................................................................................42
RSSM/RSSD SELF-CONTAINED R449a AFTER 01/01/2020...................................42
RSSM/RSSD REMOTE R449a EEV AFTER 01/01/2020...........................................43
RSSM878R REMOTE R449a EEV AFTER 01/01/2020.............................................44
NSSM ALL.................................................................................................................45
RSSM3, 4, 5, & 6 REMOTE W/LED VERTICAL STRIP LIGHTS ...............................46
RSSM8 SELF-CONTAINED W/LED STRIP LIGHTS.................................................47
RSSM8 REMOTE W/LED STRIP LIGHTS.................................................................48
RSSD8 REMOTE W/LED VERTICAL STRIP LIGHTS...............................................49
RSSM/RSSD WIRING DIAGRAMS PRIOR TO 02/01/19........................... 50 THRU 61

INTRODUCTION
Thank you for purchasing a Federal Industries Merchandiser. This manual contains important instructions for
installing and servicing the RSSM, Refrigerated Self-Service Merchandisers. A repair parts list is also included in
the manual. Read all of these documents carefully before installing or servicing your case.
NOTICE
Read this manual before installing your case. Keep this manual and refer to it before doing any service
on the equipment. Failure to do so could result in personal injury or damage to the case.
NOTICE
Installation and service of the electrical components in the case must be performed by a licensed
electrician.
The portions of this manual covering components contain technical instructions intended only for persons
qualified to perform electrical work.
DANGER
Improper or faulty hookup of electrical components in the case can result in severe injury or death.
All electrical wiring hookups must be done in accordance with all applicable local, regional, or national
standards.
NOTE: UNIT MUST BE GROUNDED
REGISTRATION & SERIAL NUMBER
It’s important to keep a record of the model and serial number of your merchandiser for warranty and part
identification. Please write them here for your quick reference.
Register your product online! Visit our website at www.federalindustries.com and register your product
today.
Case Model__________________________ Serial Number______________________
We’re here to provide you with the best possible experience with your new product, however, we cannot cover
everything about your merchandiser in this manual, so if you have any additional questions or issues, please see
the SERVICE INFORMATION PAGE to find who you should contact.
Refrigerated Self-Serve Merchandiser (High Profile) Page 1

WARNING LABELS AND SAFETY
INSTRUCTIONS
This is the safety-alert symbol. When you see this symbol on your case or in the
manual, be alert to the potential for personal injury or damage to your equipment.
Be sure you understand all safety messages and always follow recommended precautions and safe
operating procedures.
NOTICE TO EMPLOYERS
You must make sure that everyone who installs, uses, or services your case is thoroughly
familiar with all safety information and procedures.
Important safety information is presented in this section and throughout the manual. The
Following signal words are used in the warning and safety messages:
DANGER: Severe injury or death will occur if you ignore the message.
WARNING: Severe injury or death can occur if you ignore the message.
CAUTION: Minor injury or damage to your case can occur if you ignore the message.
NOTICE: This is important installation, operation, or service information. If you ignore the
message, you may damage your case.
The warning and safety labels shown throughout this manual are placed on your Federal
Industries case at the factory. Follow all warning label instructions. If any warning or safety labels
become lost or damaged, call our customer service department at 1(800) 356-4206 for replacements.
This label is located on the back of the display case This label is located below the display pan.
and on the front of the case behind the access panel.
Refrigerated Self-Serve Merchandiser (High Profile) Page 2
CAUTION
POWER BEFORE
RISK OF ELECTRIC
SHOCK DISCONNECT
91-12340
SERVICING UNIT.
CAUTION
HAZARDOUS MOVING PARTS
DO NOT OPERATE UNIT WITH
DISPLAY PANS REMOVED.

PRE-INSTALLATION PROCEDURES
Inspection For Shipping Damage
You are responsible for filing all freight claims with the delivering truck line.
Inspect all cartons and crates for damage upon arrival. If there is damage to
shipping crates, cartons, or if a shortage is found, note this on (all copies) of
the Bill Of Lading prior to signing.
If damage is discovered when the case is uncrated, immediately call the delivering
truck line and follow-up the call with a written report indicating concealed damage to
your shipment. Ask for an immediate inspection of your concealed damaged item.
Crating material must be retained and shown to the inspector from the truck line.
INSTALLATION INSTRUCTIONS
Locating the Display Case NOTE: This case is designed for indoor use only.
The case should be located where it is not subjected to the direct rays of the sun,
heating ducts, grills, radiators, or ceiling fans, nor should it be located near open doors or
main door entrances. Avoid locations where there is excessive air movement or air
disturbances and avoid high humidity locations such as near cases with water misting or
fogging devices.
The condenser air inlet is located in the front center of the base. Do not block this inlet and
do not locate the air inlet near a source of heat. Prior to 01/01/20 clearance of 6” minimum
must be maintained at the back of the case for condenser discharge air. After 01/01/20 the
case requires no clearance at the back of the unit unless it has rear condenser air intake and
discharge. Clearance at the top of the case should also be at least 8”.
Do not build this unit into an alcove and do not locate where condenser discharge air
cannot escape or where warm condenser air is allowed to re-circulate.
Grill Removal
WARNING: Electrical shock hazard. Do not operate unit with panels removed.
Must remove front and rear base grills for merchandiser installation. The front base side grilles
are secured with self-threading screws located in the top grille rail, and the rear base grill is
secured with self-threading screws.
These base grills must be replaced after merchandiser installation. Base grills must be
in place for proper operation of the merchandiser.
Refrigerated Self-Serve Merchandiser (High Profile) Page 3

Removing Case From Shipping Skid
CAUTION: If a Johnson bar or pry bar is used to move the case, make certain that
the case is lifted under the welded steel frame, and not by the end panels of the case.
Damage to the ends will result from lifting under the end panels.
Move the case as near as possible to the final location before removing it from the
shipping skid. Having removed the front and rear compressor compartment grills. Remove
the (three or four sets of bolts, nuts, and washers depending on case size) that secure the case to the
shipping skid. Discard these bolts, nuts, and washers.
Removing Packaging Material
Remove bubble wrap and packing material for all shelves, etc. If it is
necessary to remove tape residue from various materials, use cleaning
compounds recommended in the cleaning section of this manual.
Leveling the Case
The case must be level for proper drainage of defrost water to the condensate evaporator or
condensate pump.
Check the level of the case along the front rail and along the top of the display pan. Shim
under the case frame as needed to level the case or if case is equipped with leg levelers,
adjust them up or down to level the case. It is recommended that the leveled case be sealed to
the floor with an NSF Listed Sealant.
Condensate Evaporator
NOTICE: Steam from the condensate evaporator may be visible around the
base of the merchandiser during normal operation.
This merchandiser may be furnished with an electric condensate evaporator, or a
electric condensate pump. Plumbing connections are not required, unless
merchandiser is specifically ordered without a condensate evaporator or pump.
The condensate evaporator can be removed from the merchandiser and the
condensate drain can be plumbed to an external drain to conserve energy. To remove
the condensate evaporator disconnect the wires at the condensate evaporator. This
must be done by a qualified electrician.
This is an open merchandiser and can produce a large amount of condensate water.
To ensure that adequate evaporator capacity is available, a high wattage heater is
used.
Make sure that the condensate drain line has not been dislodged during shipment and
that the drain trap terminates properly over the water reservoir.
Refrigerated Self-Serve Merchandiser (High Profile) Page 4

Lights
Standard Top Light
The case comes with one standard top light which is internally wired to the power
source. The light switch is located in the top light housing under the top canopy.
On RSSM’S the light switch is located on the left top ceiling behind the air discharge
honey comb. On RSSD’S the light switch is located on the left of the top light housing.
Optional Shelf Lights
If optional shelf lights are furnished, make certain that the shelf light cords are completely
inserted into the sockets in the back panel and end of led lights or lights will not work
The power supplies used on this case allow removal of one or more shelf lights without
affecting the remaining lights.
When plugging or unplugging light cords, turn the light switch to the “off” position.
Refrigerated Self-Serve Merchandiser (High Profile) Page 5

ELECTRICAL CONNECTION AND
GROUNDING INSTRUCTIONS
Electrical Supply Wiring
DANGER: Improper or faulty hookup of electrical components in the
display case can result in severe injury or death.
THIS CASE MUST BE GROUNDED
Permanent Connection (Standard)
-Only a licensed electrician must perform all case electrical connections.
-All electrical wiring hookups must be done in accordance with all applicable local, regional, or national
electrical standards.
-A separate circuit for each display case is required to prevent other appliances on the same circuit from
overloading the circuit and causing malfunction.
-The electrical service must be grounded upon installation.
-See the electrical data plate located at the rear of the case for circuit load and wire current capacity.
-Standard Base Electrical Connection: The electrical connection box is accessible from the rear of the case.
Power Supply Wiring can be routed through the floor of the base frame or through the access hole in the rear of
the unit. Remove electrical box cover to access electrical connections.
POWERINBOX POWERINACCESSHOLE
POWERINBOX
POWERINACCESSHOLE
PRIOR TO 01/01/2020
AFTER 01/01/2020
BACK VIEW OF CASE
Refrigerated Self-Serve Merchandiser (High Profile) Page 6

Cord Connection (Optional)
-A factory installed optional power cord is properly sized to the amperage requirements of the merchandiser.
See the electrical data plate located on the ceiling of the merchandiser for the proper power requirements for
each merchandiser.
- The cord is factory installed protruding from the rear of the merchandiser.
-A separate circuit for each display merchandiser is required to prevent other appliances on the same circuit
from overloading the circuit and causing a power loss.
PRIOR TO 01/01/2020
AFTER 01/01/2020
Refrigerated Self-Merchandiser (High Profile) Page 7

OPERATING INSTRUCTIONS
Initial Start-Up
-After completing the items in the installation section of this manual. The case is ready
to be put into service. On self-contained models, the service valves on the refrigeration
system are back-seated when the unit leaves the factory.
-RSSM/RSSD cases are designed to operate at 40º to 41º F. under ambient conditions not to
exceed 75º F. and 55% relative humidity.
-Nearly all open refrigerated merchandisers operate better when loaded with product than
when empty. If a check is made of the case operating temperatures, perform this check
with product in the case.
-Open refrigerated merchandisers are not intended as storage refrigerators and will not “pull
down” room temperature products efficiently. Load case interior with pre-chilled product only.
Light Switch And Lights
The light switch is located in the ceiling. This switch operates the interior lights only. If optional
shelf lights are installed, they are also controlled by this switch.
Led Light Replacement
The light is attached to the shelf with plastic spring clips. To remove a light, un plug cord from
end of bulb and pull down.
When replacing lights, use direct equivalents to the original bulbs.
Digital Display
This unit is equipped with a CAREL temperature control with Digital Display.
The Display show a number 1 thru 9 to indicate temperature level.
Placing Product In Case
Do not overload the case with product to a point where the top air discharge grill or the
bottom air intake grill are blocked, or where the air curtain created by the discharge air is
blocked.
LOAD CASE INTERIOR WITH PRE-CHILLED 38deg OR COLDER
PRODUCT ONLY.
Energy Saving Night Curtain
This unit is equipped with an energy saving night curtain.
The night curtain is located in the top inside front of the canopy.
To use the night-curtain pull down and latch on front panel just below the
clear acrylic air deflector when case is not in use.
NOTICE: This refrigerated display case is designed to operate
in a maximum environment of 75 DEG. F and 55% relative
humidity. Exceeding these limits will cause poor case
Refrigerated Self-Serve Merchandiser (High Profile) Page 8

User Control RANCO REPLACEMENT PARTS FOR THIS CONTROL NO
LONGER AVAILABLE - REPLACED BY THE CAREL CONTROL
Using The Electronic Control
This control is located behind the front base panel.
Temperature Control Knob
This controls the temperature of the display interior of merchandiser.
-OFF: Turning the control counterclockwise to the “WARM” setting is an
Off position, this position turns the refrigeration off and all indicator
lights will also be off at this setting.
-ON; The control will be on from the warmest setting at “1” and the coldest
setting at “COLD
Cooling light
This light will be on when control requires refrigeration to be on. The compressor /
condensing unit should be running to cool the case.
Defrost light
This light will be on when control when refrigeration is defrosting allowing ice to melt off
of evaporator coil. The number of times and length of defrost will vary depending on
case environment.
Alarm light
This light indicates that there is a problem with case or electronic control and service
should be called.
Refrigerated Self-Serve Merchandiser (High Profile) Page 9
ELECTRONIC
CONTROL
COOLING
INDICATOR
DEFROST
INDICATOR
ALARM
INDICATOR
TEMPERATURE
CONTROL KNOB

User Control CAREL THIS CONTROL REPLACES THE RANCO CONTROL
WHICH IS NO LONGER AVAILABLE
Electronic Temperature Control
DIGITAL DISPLAY
SETPOINTADJUSTMODE
POWERTOCONTROL ON/OFF
ANDSETPOINTUPADJUST
MANUAL DEFROSTAND
SETPOINTDOWNADJUST
COMPRESSORRUN
INDICATOR
DEFROSTMODEINDICATOR
ALARMINDICATOR
Button Overview
Press and hold this button for three seconds to turn system on (if off) or off (if on).
Also used to adjust set point when in set point adjust mode
Press to enter set point adjust mode, confirm set point changes, and mute alarms.
Press and hold this button for three seconds to initiate a manual defrost (and cancel
defrost if initiated), also adjusts set point down when in set point adjust mode
Powering on control
To turn refrigeration control power on, press and hold for approx. three seconds. The display will
read “On” while the button is depressed. When the control powers on, the display will read the current
set point (a number “1” thru “9” ). The compressor run indicator will illuminate on the display,
meaning that the compressor is running. (Note: the control may already be in the on mode when
shipped from factory).
To turn refrigeration control power to off, press and hold for approx. three seconds. The display
will read “Off” while the button is depressed. When the control powers off the display will flash back
and forth between the relative current case temperature and “Off”. The compressor run indicator
will be off on the display. When refrigeration control is in the off-mode cabinet lights and evaporator
fans will still operate, but the compressor will not turn on causing the case to gradually reach room
temperature.
Refrigerated Self-Serve Merchandiser (High Profile) Page 10

Adjusting the set point
The set point is what determines how cold the display case will hold food and beverage. To adjust the set point
press and hold the button approx. three seconds until the display begins to flash a number. Then press the
use the button to scroll number up (colder) or press the button to scroll number lower (warmer). There
are nine (9) available set points numbers, the higher the number of the set point, the colder the display case will
run, with setting “9” being the coldest and setting “1” being the warmest. Once you have chosen your desired
setting press the button again to confirm your choice.
Entering manual defrost mode
In order to initiate a manual defrost press and hold the button approx. three seconds. The control will read
“dEF” while the button is being held. The defrost is initiated when the defrost mode indicator illuminates on
the display. The control display will then return to reading the case temperature. When the defrost mode
indicator turns off the defrost is complete and the compressor will turn back on illuminating the compressor
run indicator .
Error
codes
It is possible for error codes to be displayed on the control screen. In the event of a malfunction an alarm will
sound and the alarm indicator will be displayed on the display. An error code or codes will flash
intermittently on the display. If there are multiple codes, the display will continuously cycle through them. The
following photo shows error code “E0” as an example.
Mute: You may mute the alarm by pressing and releasing the wrench button. The red ringing bell and all error
codes will still be displayed. When the fault is remedied the control will return to normal operation and will
automatically clear the codes from the display.
Refrigerated Self-Serve Merchandiser (High Profile) Page 11

Ranco control
E1 = Air sensing probe - Open or Shorted and needs replacing
E2 = Evap. Coil probe - Open or Shorted and needs replacing
Carel Control
EO = Air sensing probe - Open or shorted
E1 = Evap. coil probe - Open or shorted
Dual Pressure Control (Self-Contained Models Only)
The dual pressure control is used as a safety device and is factory set. The pressure control
works on a differential. The low-pressure side is a safety to protect the compressor in the case
of refrigerant loss. The high-pressure side is a safety to protect from system failure causing too
high of system pressure.
The high side of the pressure control is factory set to 400psi and is not adjustable.
Low side setting for the R404a cases are set at 40psi differential for the cutout and 60psi for
the cut-in.
Refrigerated Self-Serve Merchandiser (High Profile) Page 12

Shelves
The RSSM has 15” solid metal shelves as standard. These shelves are installed at the
factory.
The shelves are adjustable in 1-5/8” increments. To adjust the shelves, first remove the shelf
from the shelf brackets. Remove the shelf bracket from the shelf standard and reposition as
desired. If optional shelf lights are installed, it will be necessary to unplug the shelf light
cord before repositioning the shelf brackets.
The shelves can be installed horizontally or slanted at a 10º downward angle. To
change the shelf slant, first remove the shelf from the shelf support. Lift the shelf
supports up at the back until the brackets can be repositioned in the shelf standard slots.
See diagram below
10 °
CAUTION:
Do not place more than 100 lbs. of product on a
RSSM3 or RSSM4 Shelf.
Do not place more than 80 lbs. of product on a
RSSM5 or RSSM6 Shelf.
Damage to the Shelf Standard may occur if the Shelf is overloaded.
Refrigerated Self-Serve Merchandiser (High Profile) Page 13

CONTROL OPERATION
Electronic Control
This unit is equipped with an Invensys –Ranco model E72R temperature control or a Carel
temperature control. The control parameters are set at the factory and cannot be manually changed in
the field. Control parameter changes can only be made by downloading a new set of parameters using
a program chip supplied by Federal Industries. The pre-set control parameters are listed on the chart in
the Settings Chart below.
Operation
The control uses two sensors, one located in the air stream and one located on the evaporator coil.
The sensor located in the air stream is referred to as the temperature control sensor. The sensor
located on the evaporator coil is referred to as the coil sensor.
The temperature control sensor is located inside the top air duct behind the honeycomb material and
is labeled (TEMP). The sensor location is critical for proper operation on the unit. Do not move or
relocate this sensor.
The coil sensor is strapped to the evaporator coil and is labeled (DEFROST). This sensor location is
critical for proper operation of the unit. Do not move or relocate this sensor.
DETAIL OF TEMPCONTROL
W/SENSORWIRESATTACHED
PROBEWIRESROUTEDTHRU
TUBFLOORANDUPBACKOFCASE
PROBEWIRESMOUNTEDTOINSIDE
FLANGEOFTOPFRONTBASERAIL
W/CABLEHOLDERS
DEFROST SENSORPROBELOCATION
3" INFROMCOIL HEADERPLATE
MOUNTEDTOCENTERCOIL TUBE
WITH(2)CABLETIES
TEMPSENSORBULB
LOCATEDLEFT OFCENTER
INAIRDISCHARGEDUCT
BLK BLK
W
TEMP. PROBE PBI
DEFROST PROBE PB2
W
CAREL
CONTROLLER
1110 9 8
76 5
4
BLK
OR
RED
BLK
OR
RED
Y
R
CASE WITH SQUARE EXTENDED CANOPY SHOWN
MAIN POWER SWITCH
REFRIGERATION CONTROL
The temperature control is set to cut in at 41 degrees F. The Temp control cuts out at 13 degrees F at
the coldest setting’ COLD’ and 28 degrees F at the warmest setting, ‘1’ on the control dial.
The temp control turns off the refrigeration system when the control is turned all the way
counterclockwise to the (WARM) position.
Refrigerated Self-Serve Merchandiser (High Profile) Page 14

Defrost Cycle
The electronic control is programmed to initiate defrost by two different methods. There are (3)
programmed defrost cycles in the control which will initiate a defrost cycle every 8 hours. The unit
does not have a time clock so the defrost cycles cannot be set for any specific time of day.
The electronic controller uses time to initiate the defrost cycle, and temperature to terminate the
defrost cycle. The controller also has an ‘On demand’ defrost feature that will initiate a defrost cycle
when the temperature differential between the evaporator temperature and the air temperature is
more than 15 degrees for 5 minutes after 30 minutes into the refrigeration cycle.
Control Factory Settings
The control parameters are set at the factory and cannot be manually changed in the field. Control
parameter changes can only be made by downloading a new set of parameters using a program chip
supplied by Federal Industries
TAB
PARAMETER DESCRIPTION
RSSL
CONFIGURATION
Controller Operation Temperature
Units
Degrees
Fahrenheit
Defrost Termination Method
Evaporator Sensor
SET-POINTS
Cut-In Warm
40ºF
Cut-Out Warm
34ºF
Cut-In Cold
40ºF
Cut-Out Cold
24ºF
COMPRESSOR
Compressor Minimum On Time
5 minutes
Compressor Maximum On Time
60 minutes
DISPLAY
Defrost Display Lock (display indication
during defrost)
SHOW CURRENT
TEMPERATURE
DEFROST
Defrost Termination Temperature
45ºF
Time to First Defrost (hh:mm)
8 hr
Time to subsequent Defrost
8 hr
Defrost Max Duration
30 minutes
Refrigerated Self-Serve Merchandiser (High Profile) Page 15

Control Display
The control display is located in the unit base. It is programmed to display the current set point
associated with the control sensor located inside the air duct at the top of the case.
Minimum Run Timer Feature
The unit controller is programmed to have the condensing unit run a minimum of 5 minutes,
regardless of the control temp being satisfied. If the temperature control reaches the cut out set point
before 5 minutes, the minimum run time setting in the control will keep the unit in a run cycle mode
until the timer reaches 5 minutes. The refrigeration cycle will be off until the temperature control cut in
temperature is reached.
This timer typically comes into effect in low ambient conditions where the unit may cycle too
frequently to maintain proper product temperature.
Maximum Run Timer Feature
The unit controller is programmed to have the condensing unit run a maximum of 60 minutes.
If the unit has not reached cut out temperature setting in 60 minutes, the unit goes into on off cycle.
This typically comes into effect in high ambient temperature and relative humidity conditions.
REFRIGERATION OPERATION
Self Contained Models
Refrigeration R404A Charge Prior To 01/01/2020
See Refrigeration
And Electrical Data
Pages
Refrigeration R449a Charge After 01/01/2020
See Refrigeration
And Electrical Data
Pages
The self-contained models are shipped from the factory with a completely operational refrigeration system and
require no modifications or adjustments upon installation. Case must be installed as per the installation section
of this manual to provide proper condensing air cooling.
Self Contained Refrigeration Operation
The unit temperature is controlled by the Electronic control outlined in the control section of this manual.
Note: The condenser fan is factory wired to run continuously.
Refrigerated Self-Serve Merchandiser (High Profile) Page 16

Remote Operation
Electronic Expansion Valve (EEV) After 1/20
A traditional TXV uses springs and a temperature bulb to open and close a valve port that controls the flow of
refrigerant entering the evaporator coil. An electronic expansion valve (EEV) controls the refrigerant flow much
more precisely, increasing the performance and efficiency of the refrigeration system. The EEV controls the
flow of Refrigerant by opening and closing the valve port based on the response to signals sent to the EEV by
an electronic controller. The electronic Control bases these signals by processing information provided from a
temperature sensor and pressure transducer located on the discharge side of the evaporator coil.
These sensors monitor the evaporator superheat and protects the compressor from any liquid flood back under
low superheat conditions.
EEV Controller Settings
The electronic expansion valve controller also allows the use of different types of refrigerants without the need
to change the expansion valve.
The controller is set from the factory to run on R449a refrigerant and will not need any changes to the control
unless another refrigerant is used.
Note: Check your State and Local regulations for approved refrigerants for your install location. Federal
Industries is not liable for any alternate refrigerants used.
The control is located on the base floor on the left hand side front view .
Note: Never change any of the other setting other than the refrigerant type. It may also be necessary to
change the superheat setting only when using a different refrigerant.
Changing Refrigerant
•Access the set point mode by pressing and holding the button until Ctl displays on the screen.
•Use the up or down arrows to advance through the available set points until rFG displays on the
screen and press the botton.
•Use the up or down arrows until the desired refrigeration displays on the screen and press and hold
the button until rFG once again displays on the screen.
•Press the to return to escape the settings menue.
Changing Superheat
•Access the set point mode by pressing and holding the button until Ctl displays on the screen.
•Use the up or down arrows to advance through the available set points until SSP displays on the
screen and press the botton.
•Use the up or down arrows to set the desired superheat displays on the screen and press and hold
the button until SSP once again displays on the screen.
•Press the to return to escape the settings menue.
Refrigerated Self-Serve Merchandiser (High Profile) Page 17
This manual suits for next models
24
Table of contents
Other Federal Display Case manuals

Federal
Federal ITD48 Installation instructions

Federal
Federal SNR48 Installation instructions

Federal
Federal ECGR50 Installation instructions

Federal
Federal CRR4828 Installation instructions

Federal
Federal FCC-4 Installation instructions

Federal
Federal SN48 Installation instructions

Federal
Federal SNR482C-2 User manual
Popular Display Case manuals by other brands

FPG
FPG INLINE 3000S Series product manual

Blizzard
Blizzard BZ-HOTT1 Operation instructions

Structural Concepts
Structural Concepts Harmony HMG2642R.4439 Installation & operating manual

Casselin
Casselin CVR120L user guide

Showcases Direct
Showcases Direct DL3M Assembly instructions

Costan
Costan FUNKY NEXT User instructions