MAXIMUM
FINISHED
SOIL
HEIGHT
DO NOT ALLOW AIR VENTS TO BE BLOCKED!
TROUBLE SHOOTING
-THERE IS NO LIGHT
You can hear the fan running: The lamp has probably failed. Replace with Fiberstars part #Y20-6000
Thereisnofanrunning:Theilluminator isnotgettingpower.Checkthe toggleswitchpositionbyreferringtothe diagramon
the front of this manual. Check the GFCI breaker and check the fuse on the illuminator.
-THE UNIT SHUTS OFF AFTER A FEW MINUTES THEN COMES BACK ON
Check to see if the air vents are blocked. Refer to the above drawing to make sure the vents are clear
Turn off the power and remove the two screws securing the cover and check for an obstruction in the cooling fan.
-REMOTE CONTROL UNITS (WITH OPTIONAL RM6000 PACKAGE-with its own seprate warranty coverage)
YOU CAN TEMPORARILY OPERATE THE UNIT MANUALLY VIA THE TOGGLE SWITCHES IF A REMOTE CONTROL
PROBLEM IS SUSPECTED. SEE THE DIAGRAM ON THE FRONT OF THIS MANUAL.
There is a click at the unit when the button is pressed, but no light: If you hear the fan running, the lamp has probably
failed. Replace with Fiberstars part #Y20-6000. If you cannot hear the fan running, the receiver module is probably defective. Have a
qualified service company replace it.
There is NO click at the unit when the button is pressed: Makesurethatthe transmitter is TURNED ON.Theredlight on
thetransmittershould glow when abuttonisdepressed. Ifthetransmitterisfunctioningproperly, but the illuminatorstilldoesnotcome
on, the receiver module may be defective. Have a qualified service company replace it. YOU CAN TEMPORARILY OPERATE THE
UNIT MANUALLY VIA THE TOGGLE SWITCHES. SEE THE DIAGRAM ON THE FRONT OF THIS MANUAL.
-LIGHTS ARE NOT BRIGHT ENOUGH
Theadequacyofpoollightingissubjectiveatbest.Whatisacceptabletomost,maynotbeforsome.Thepoolbuilderisgiven
guidelinesby Fiberstars,andthebuilderalone isresponsibleforthefinal designandinstallation.Thereare manyfactorsthatdetermine
the ultimate brightness of our product; fiber lengths, pool finish color, installation techniques, etc. Remember that darker colors on our
color wheel, i.e. magenta, are not as bright as lighter colors like white.
Your 6004 / 6004-AS illuminator needs air to breathe! Lack of
ventilation can cause the unit to overheat. This will shorten the lamp
life and could damage the unit. DAMAGE TO THE UNIT BECAUSE OF
BLOCKED AIR VENTS IS NOT COVERED UNDER OUR WARRANTY!
AIR FLOW
AIR FLOW