Fieldpiece MG44 User manual

01
06
02
07
03
08
04
09
05
10
Wireless Vacuum Gauge
MG44
NEXT
ALARM
ENTER
MENU
GASKETS: Each end of the coupler is sealed
by a black rubber gasket. These may become
worn over time due to overtightening or
connecting to damaged male ttings.
1. Use needle nose pliers or a similar tool to unscrew the Schrader
valve depressor from the gasket.
2. Remove and replace the worn gasket.
3. Screw the depressor back into the gasket.
Reversible Coupler
It's best to avoid using a hose to connect
your vacuum gauge to the system. The coupler
makes it easy to connect the gauge directly to a
service port or valve core removal tool.
Each end has a valve depressor and gasket so
you can ip the coupler to best t the system
and your viewing angle. Rotate and tighten
each end independently for optimal viewing
and control.
Quick Start
1. Unscrew the battery cover and install (2) AA
alkaline batteries.
2. Hold
MENU
ENTER
ALARM
NEXT
to power on.
Wireless setting is briefly displayed (ON/OFF).
Activate wireless in the menu to send measure-
ments to compatible Job Link® system tools.
3. Connecttotheequipmentyou'reevacuating.
Connect directly to an unused service port or to
a Schrader valve core removal tool.
4. View the live measurement on the top line.
5. Press NEXT to change bottom line view.
What's Included
(1) MG44 Wireless Vacuum Gauge
(1) Reversible 1/4" angled (45°) coupler
(2) AA Batteries
(1) Operator's manual
(1) Year limited warranty
Description
Use the MG44 Wireless Vacuum Gauge
to reliably monitor your evacuations in the
eld. Long range wireless technology sends
deep vacuum measurements up to 1000 feet
(305 meters) away. View live on your SMANTM
manifold, in the Job Link® mobile app, or directly
on the MG44.
Save time by wirelessly monitoring your
evacuations. Remotely view trending on the
Job Link mobile app so you know when an extra
nitrogen purge is required, a leak is suspected,
or just watch everything pull as planned.
Reduce the misleading nature of dynamic
vacuum measurement during pull down by
connecting MG44 directly to the system. The
reversible angled coupler makes it easy to orient
the gauge so that it's out of the way and easy
to see.
Select one of three unique views, including a
new Rate Meter that provides a great feel and
a Bar Graph that has a range up to atmosphere.
Built for demanding eld use, the overmolded
case resists damage from physical impact and
water ingress.
Maintenance
CLEANING: Clean the exterior with a damp
cloth. Do not use detergents or solvents.
SENSOR: Clean the sensor on a regular basis
to prevent the build up of oils and contaminents.
DO NOT use an object such as a cotton swab to
clean the sensor. This may damage the sensor.
1. Power o MG44.
2. If attached, remove the coupler from MG44 to expose the cavity of
the 1/4" male tting.
3. Fill up about half of the cavity with isopropyl (rubbing) alcohol or
AC system ush.
4. Cover the cavity and gently shake it for about 15-30 seconds.
5. Pour out the dirty solution and let the vacuum sensor dry with the
tting facing down.
BATTERIES: An empty battery icon
indicates batteries need to be replaced. When
power is too low to operate, "LoBatt" is displayed
5 sec before powering o automatically.You can
also monitor battery life in the Job Link app tool
manager.
1. Power o MG44.
2. Unscrew the battery cover (2 screws) and dispose of batteries
according to local law.
3. Install (2) new alkaline AA batteries.
4. Reinstall cover.
Wireless
Vacuum
Gauge
OPERATOR'S
MANUAL
Model MG44
Operation
Buttons
Unless muted, each button press triggers
a beep. An inactive button press triggers a
double beep.
Hold to toggle power.
Toggle backlight.
Silence alarm.
Hold to enter MENU.
Hold to exit MENU without saving.
ENTER selection.
Stop low alarm and start high alarm.
NEXT view.
NEXT menu item or increase value.
Hold to toggle ALARM mode.
Silence alarm.
Display
In standard operating mode, the top line
shows the live measurement. The bottom line
shows one of three selectable views.
: Auto Power O Enabled
: Battery Level
: Low Alarm
: High Alarm
: Muted
: Rate (dierential per minute)
: Wireless Enabled (shown at startup)
: Wireless Disabled (shown at startup)
Views
Press NEXT to change the content of the
bottom line. Each view provides a unique way
to monitor your evacuation.
RATE: The running 10-second average of the
measurement's change per minute. Negative
rates indicate the vacuum is getting deeper.
RATE METER: The graphical representation
of the measurement's real-time change per
minute. The scale is dynamic (i.e. relative to the
measurement) making changes easy to see.
Decreasing
Stable
Increasing
BAR GRAPH: The graphical representation
of the measurement. The scale is static and
nonlinear for increased resolution at deeper
vacuums. Full bars indicates atmospheric
pressure.
~3500 micronHg
Alarm Mode
Every evacuation is dierent. Some require
multiple purges of dry nitrogen, while some take
less time than a phone call. Activate alarm mode
so you can get other things handled without
babysitting your gauge.
Follow recommended evacuation practices
from the equipment manufacturer and training.
Alarm levels can be adjusted in the menu.
1. Hold ALARM to activate* low alarm (L).
Stopwatch starts. APO deactivates.
Turn on your vacuum pump.
2. Once the low alarm level is reached, the back-
light blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Isolate the vacuum pump from the system.
3. Press ENTER to activate high alarm (H).
Stopwatch restarts.
4. Once the high alarm level is reached, the
backlight blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Stopwatch stops.
5. Press ENTER to exit alarm mode.
APO reactivates.
* Hold ALARM to exit alarm mode at any time.
Specifications
Connector Type: 1/4'' SAE male tting. Includes reversible 1/4"
angled (45°) coupler with Schrader depressors.
Max Pressure: 870 psig (60 bar)
Refresh Rate: 0.5 seconds
Accuracy: ±(5% reading + 5 micron) at 77°F (25°C), 50 to 2000 micron
Measurement Range and Units:
50 to 25000 micronHg (mTorr); 0.05 to 25 mmHg (Torr);
6 to 3333 Pascals; 0.06 to 33.33 mBar
Bar Graph Range: ultimate vacuum to atmospheric pressure
Best Resolution:
1 micronHg(mTorr), below 2000; 0.001 mmHg (Torr), below 2.5;
1 Pascal, below 250; 0.001 mBar, below 2.5;
Battery Type: 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6
Battery Life: 50 hours typical alkaline
Auto Power Off: 15 minutes default (APO adjustable)
Wireless Range: 1000 feet (305 meters) line of sight.
Obstructions aect distance.
Radio Frequency: 2.4 GHz
Wireless Device Requirements:
(Latest compatibility and firmware at www.fieldpiece.com)
Job Link® app: BLE 4.0 devices with iOS® 7.0 or Android™ 5.0
SMANTM manifold: Models SM380V/SM480V with latest
rmware installed.
Water Resistance: IP54
Operating Environment: 14°F to 122°F (-10°C to 50°C) at
<75%RH
Storage Temperature: -4°F to 140°F (-20°C to 60°C) at <80%RH
(with batteries removed)
Weight: 0.66 lbs (300 g)
US Patent: www.eldpiece.com/patents
!
WARNINGS
Disconnect MG44 from system before applying pressure; pressures above
870 psig (60 bar) can damage the vacuum gauge.
Hand tighten ttings; overtightening may damage seals.
Follow all equipment manufacturer’s testing procedures above those in
this manual in regards to properly servicing their equipment.

01
06
02
07
03
08
04
09
05
10
Wireless Vacuum Gauge
MG44
NEXT
ALARM
ENTER
MENU
GASKETS: Each end of the coupler is sealed
by a black rubber gasket. These may become
worn over time due to overtightening or
connecting to damaged male ttings.
1. Use needle nose pliers or a similar tool to unscrew the Schrader
valve depressor from the gasket.
2. Remove and replace the worn gasket.
3. Screw the depressor back into the gasket.
Reversible Coupler
It's best to avoid using a hose to connect
your vacuum gauge to the system. The coupler
makes it easy to connect the gauge directly to a
service port or valve core removal tool.
Each end has a valve depressor and gasket so
you can ip the coupler to best t the system
and your viewing angle. Rotate and tighten
each end independently for optimal viewing
and control.
Quick Start
1. Unscrew the battery cover and install (2) AA
alkaline batteries.
2. Hold
MENU
ENTER
ALARM
NEXT
to power on.
Wireless setting is briefly displayed (ON/OFF).
Activate wireless in the menu to send measure-
ments to compatible Job Link® system tools.
3. Connecttotheequipmentyou'reevacuating.
Connect directly to an unused service port or to
a Schrader valve core removal tool.
4. View the live measurement on the top line.
5. Press NEXT to change bottom line view.
What's Included
(1) MG44 Wireless Vacuum Gauge
(1) Reversible 1/4" angled (45°) coupler
(2) AA Batteries
(1) Operator's manual
(1) Year limited warranty
Description
Use the MG44 Wireless Vacuum Gauge
to reliably monitor your evacuations in the
eld. Long range wireless technology sends
deep vacuum measurements up to 1000 feet
(305 meters) away. View live on your SMANTM
manifold, in the Job Link® mobile app, or directly
on the MG44.
Save time by wirelessly monitoring your
evacuations. Remotely view trending on the
Job Link mobile app so you know when an extra
nitrogen purge is required, a leak is suspected,
or just watch everything pull as planned.
Reduce the misleading nature of dynamic
vacuum measurement during pull down by
connecting MG44 directly to the system. The
reversible angled coupler makes it easy to orient
the gauge so that it's out of the way and easy
to see.
Select one of three unique views, including a
new Rate Meter that provides a great feel and
a Bar Graph that has a range up to atmosphere.
Built for demanding eld use, the overmolded
case resists damage from physical impact and
water ingress.
Maintenance
CLEANING: Clean the exterior with a damp
cloth. Do not use detergents or solvents.
SENSOR: Clean the sensor on a regular basis
to prevent the build up of oils and contaminents.
DO NOT use an object such as a cotton swab to
clean the sensor. This may damage the sensor.
1. Power o MG44.
2. If attached, remove the coupler from MG44 to expose the cavity of
the 1/4" male tting.
3. Fill up about half of the cavity with isopropyl (rubbing) alcohol or
AC system ush.
4. Cover the cavity and gently shake it for about 15-30 seconds.
5. Pour out the dirty solution and let the vacuum sensor dry with the
tting facing down.
BATTERIES: An empty battery icon
indicates batteries need to be replaced. When
power is too low to operate, "LoBatt" is displayed
5 sec before powering o automatically.You can
also monitor battery life in the Job Link app tool
manager.
1. Power o MG44.
2. Unscrew the battery cover (2 screws) and dispose of batteries
according to local law.
3. Install (2) new alkaline AA batteries.
4. Reinstall cover.
Wireless
Vacuum
Gauge
OPERATOR'S
MANUAL
Model MG44
Operation
Buttons
Unless muted, each button press triggers
a beep. An inactive button press triggers a
double beep.
Hold to toggle power.
Toggle backlight.
Silence alarm.
Hold to enter MENU.
Hold to exit MENU without saving.
ENTER selection.
Stop low alarm and start high alarm.
NEXT view.
NEXT menu item or increase value.
Hold to toggle ALARM mode.
Silence alarm.
Display
In standard operating mode, the top line
shows the live measurement. The bottom line
shows one of three selectable views.
: Auto Power O Enabled
: Battery Level
: Low Alarm
: High Alarm
: Muted
: Rate (dierential per minute)
: Wireless Enabled (shown at startup)
: Wireless Disabled (shown at startup)
Views
Press NEXT to change the content of the
bottom line. Each view provides a unique way
to monitor your evacuation.
RATE: The running 10-second average of the
measurement's change per minute. Negative
rates indicate the vacuum is getting deeper.
RATE METER: The graphical representation
of the measurement's real-time change per
minute. The scale is dynamic (i.e. relative to the
measurement) making changes easy to see.
Decreasing
Stable
Increasing
BAR GRAPH: The graphical representation
of the measurement. The scale is static and
nonlinear for increased resolution at deeper
vacuums. Full bars indicates atmospheric
pressure.
~3500 micronHg
Alarm Mode
Every evacuation is dierent. Some require
multiple purges of dry nitrogen, while some take
less time than a phone call. Activate alarm mode
so you can get other things handled without
babysitting your gauge.
Follow recommended evacuation practices
from the equipment manufacturer and training.
Alarm levels can be adjusted in the menu.
1. Hold ALARM to activate* low alarm (L).
Stopwatch starts. APO deactivates.
Turn on your vacuum pump.
2. Once the low alarm level is reached, the back-
light blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Isolate the vacuum pump from the system.
3. Press ENTER to activate high alarm (H).
Stopwatch restarts.
4. Once the high alarm level is reached, the
backlight blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Stopwatch stops.
5. Press ENTER to exit alarm mode.
APO reactivates.
* Hold ALARM to exit alarm mode at any time.
Specifications
Connector Type: 1/4'' SAE male tting. Includes reversible 1/4"
angled (45°) coupler with Schrader depressors.
Max Pressure: 870 psig (60 bar)
Refresh Rate: 0.5 seconds
Accuracy: ±(5% reading + 5 micron) at 77°F (25°C), 50 to 2000 micron
Measurement Range and Units:
50 to 25000 micronHg (mTorr); 0.05 to 25 mmHg (Torr);
6 to 3333 Pascals; 0.06 to 33.33 mBar
Bar Graph Range: ultimate vacuum to atmospheric pressure
Best Resolution:
1 micronHg(mTorr), below 2000; 0.001 mmHg (Torr), below 2.5;
1 Pascal, below 250; 0.001 mBar, below 2.5;
Battery Type: 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6
Battery Life: 50 hours typical alkaline
Auto Power Off: 15 minutes default (APO adjustable)
Wireless Range: 1000 feet (305 meters) line of sight.
Obstructions aect distance.
Radio Frequency: 2.4 GHz
Wireless Device Requirements:
(Latest compatibility and firmware at www.fieldpiece.com)
Job Link® app: BLE 4.0 devices with iOS® 7.0 or Android™ 5.0
SMANTM manifold: Models SM380V/SM480V with latest
rmware installed.
Water Resistance: IP54
Operating Environment: 14°F to 122°F (-10°C to 50°C) at
<75%RH
Storage Temperature: -4°F to 140°F (-20°C to 60°C) at <80%RH
(with batteries removed)
Weight: 0.66 lbs (300 g)
US Patent: www.eldpiece.com/patents
!
WARNINGS
Disconnect MG44 from system before applying pressure; pressures above
870 psig (60 bar) can damage the vacuum gauge.
Hand tighten ttings; overtightening may damage seals.
Follow all equipment manufacturer’s testing procedures above those in
this manual in regards to properly servicing their equipment.

01
06
02
07
03
08
04
09
05
10
Wireless Vacuum Gauge
MG44
NEXT
ALARM
ENTER
MENU
GASKETS: Each end of the coupler is sealed
by a black rubber gasket. These may become
worn over time due to overtightening or
connecting to damaged male ttings.
1. Use needle nose pliers or a similar tool to unscrew the Schrader
valve depressor from the gasket.
2. Remove and replace the worn gasket.
3. Screw the depressor back into the gasket.
Reversible Coupler
It's best to avoid using a hose to connect
your vacuum gauge to the system. The coupler
makes it easy to connect the gauge directly to a
service port or valve core removal tool.
Each end has a valve depressor and gasket so
you can ip the coupler to best t the system
and your viewing angle. Rotate and tighten
each end independently for optimal viewing
and control.
Quick Start
1. Unscrew the battery cover and install (2) AA
alkaline batteries.
2. Hold
MENU
ENTER
ALARM
NEXT
to power on.
Wireless setting is briefly displayed (ON/OFF).
Activate wireless in the menu to send measure-
ments to compatible Job Link® system tools.
3. Connecttotheequipmentyou'reevacuating.
Connect directly to an unused service port or to
a Schrader valve core removal tool.
4. View the live measurement on the top line.
5. Press NEXT to change bottom line view.
What's Included
(1) MG44 Wireless Vacuum Gauge
(1) Reversible 1/4" angled (45°) coupler
(2) AA Batteries
(1) Operator's manual
(1) Year limited warranty
Description
Use the MG44 Wireless Vacuum Gauge
to reliably monitor your evacuations in the
eld. Long range wireless technology sends
deep vacuum measurements up to 1000 feet
(305 meters) away. View live on your SMANTM
manifold, in the Job Link® mobile app, or directly
on the MG44.
Save time by wirelessly monitoring your
evacuations. Remotely view trending on the
Job Link mobile app so you know when an extra
nitrogen purge is required, a leak is suspected,
or just watch everything pull as planned.
Reduce the misleading nature of dynamic
vacuum measurement during pull down by
connecting MG44 directly to the system. The
reversible angled coupler makes it easy to orient
the gauge so that it's out of the way and easy
to see.
Select one of three unique views, including a
new Rate Meter that provides a great feel and
a Bar Graph that has a range up to atmosphere.
Built for demanding eld use, the overmolded
case resists damage from physical impact and
water ingress.
Maintenance
CLEANING: Clean the exterior with a damp
cloth. Do not use detergents or solvents.
SENSOR: Clean the sensor on a regular basis
to prevent the build up of oils and contaminents.
DO NOT use an object such as a cotton swab to
clean the sensor. This may damage the sensor.
1. Power o MG44.
2. If attached, remove the coupler from MG44 to expose the cavity of
the 1/4" male tting.
3. Fill up about half of the cavity with isopropyl (rubbing) alcohol or
AC system ush.
4. Cover the cavity and gently shake it for about 15-30 seconds.
5. Pour out the dirty solution and let the vacuum sensor dry with the
tting facing down.
BATTERIES: An empty battery icon
indicates batteries need to be replaced. When
power is too low to operate, "LoBatt" is displayed
5 sec before powering o automatically.You can
also monitor battery life in the Job Link app tool
manager.
1. Power o MG44.
2. Unscrew the battery cover (2 screws) and dispose of batteries
according to local law.
3. Install (2) new alkaline AA batteries.
4. Reinstall cover.
Wireless
Vacuum
Gauge
OPERATOR'S
MANUAL
Model MG44
Operation
Buttons
Unless muted, each button press triggers
a beep. An inactive button press triggers a
double beep.
Hold to toggle power.
Toggle backlight.
Silence alarm.
Hold to enter MENU.
Hold to exit MENU without saving.
ENTER selection.
Stop low alarm and start high alarm.
NEXT view.
NEXT menu item or increase value.
Hold to toggle ALARM mode.
Silence alarm.
Display
In standard operating mode, the top line
shows the live measurement. The bottom line
shows one of three selectable views.
: Auto Power O Enabled
: Battery Level
: Low Alarm
: High Alarm
: Muted
: Rate (dierential per minute)
: Wireless Enabled (shown at startup)
: Wireless Disabled (shown at startup)
Views
Press NEXT to change the content of the
bottom line. Each view provides a unique way
to monitor your evacuation.
RATE: The running 10-second average of the
measurement's change per minute. Negative
rates indicate the vacuum is getting deeper.
RATE METER: The graphical representation
of the measurement's real-time change per
minute. The scale is dynamic (i.e. relative to the
measurement) making changes easy to see.
Decreasing
Stable
Increasing
BAR GRAPH: The graphical representation
of the measurement. The scale is static and
nonlinear for increased resolution at deeper
vacuums. Full bars indicates atmospheric
pressure.
~3500 micronHg
Alarm Mode
Every evacuation is dierent. Some require
multiple purges of dry nitrogen, while some take
less time than a phone call. Activate alarm mode
so you can get other things handled without
babysitting your gauge.
Follow recommended evacuation practices
from the equipment manufacturer and training.
Alarm levels can be adjusted in the menu.
1. Hold ALARM to activate* low alarm (L).
Stopwatch starts. APO deactivates.
Turn on your vacuum pump.
2. Once the low alarm level is reached, the back-
light blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Isolate the vacuum pump from the system.
3. Press ENTER to activate high alarm (H).
Stopwatch restarts.
4. Once the high alarm level is reached, the
backlight blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Stopwatch stops.
5. Press ENTER to exit alarm mode.
APO reactivates.
* Hold ALARM to exit alarm mode at any time.
Specifications
Connector Type: 1/4'' SAE male tting. Includes reversible 1/4"
angled (45°) coupler with Schrader depressors.
Max Pressure: 870 psig (60 bar)
Refresh Rate: 0.5 seconds
Accuracy: ±(5% reading + 5 micron) at 77°F (25°C), 50 to 2000 micron
Measurement Range and Units:
50 to 25000 micronHg (mTorr); 0.05 to 25 mmHg (Torr);
6 to 3333 Pascals; 0.06 to 33.33 mBar
Bar Graph Range: ultimate vacuum to atmospheric pressure
Best Resolution:
1 micronHg(mTorr), below 2000; 0.001 mmHg (Torr), below 2.5;
1 Pascal, below 250; 0.001 mBar, below 2.5;
Battery Type: 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6
Battery Life: 50 hours typical alkaline
Auto Power Off: 15 minutes default (APO adjustable)
Wireless Range: 1000 feet (305 meters) line of sight.
Obstructions aect distance.
Radio Frequency: 2.4 GHz
Wireless Device Requirements:
(Latest compatibility and firmware at www.fieldpiece.com)
Job Link® app: BLE 4.0 devices with iOS® 7.0 or Android™ 5.0
SMANTM manifold: Models SM380V/SM480V with latest
rmware installed.
Water Resistance: IP54
Operating Environment: 14°F to 122°F (-10°C to 50°C) at
<75%RH
Storage Temperature: -4°F to 140°F (-20°C to 60°C) at <80%RH
(with batteries removed)
Weight: 0.66 lbs (300 g)
US Patent: www.eldpiece.com/patents
!
WARNINGS
Disconnect MG44 from system before applying pressure; pressures above
870 psig (60 bar) can damage the vacuum gauge.
Hand tighten ttings; overtightening may damage seals.
Follow all equipment manufacturer’s testing procedures above those in
this manual in regards to properly servicing their equipment.

01
06
02
07
03
08
04
09
05
10
Wireless Vacuum Gauge
MG44
NEXT
ALARM
ENTER
MENU
GASKETS: Each end of the coupler is sealed
by a black rubber gasket. These may become
worn over time due to overtightening or
connecting to damaged male ttings.
1. Use needle nose pliers or a similar tool to unscrew the Schrader
valve depressor from the gasket.
2. Remove and replace the worn gasket.
3. Screw the depressor back into the gasket.
Reversible Coupler
It's best to avoid using a hose to connect
your vacuum gauge to the system. The coupler
makes it easy to connect the gauge directly to a
service port or valve core removal tool.
Each end has a valve depressor and gasket so
you can ip the coupler to best t the system
and your viewing angle. Rotate and tighten
each end independently for optimal viewing
and control.
Quick Start
1. Unscrew the battery cover and install (2) AA
alkaline batteries.
2. Hold
MENU
ENTER
ALARM
NEXT
to power on.
Wireless setting is briefly displayed (ON/OFF).
Activate wireless in the menu to send measure-
ments to compatible Job Link® system tools.
3. Connecttothe equipmentyou'reevacuating.
Connect directly to an unused service port or to
a Schrader valve core removal tool.
4. View the live measurement on the top line.
5. Press NEXT to change bottom line view.
What's Included
(1) MG44 Wireless Vacuum Gauge
(1) Reversible 1/4" angled (45°) coupler
(2) AA Batteries
(1) Operator's manual
(1) Year limited warranty
Description
Use the MG44 Wireless Vacuum Gauge
to reliably monitor your evacuations in the
eld. Long range wireless technology sends
deep vacuum measurements up to 1000 feet
(305 meters) away. View live on your SMANTM
manifold, in the Job Link® mobile app, or directly
on the MG44.
Save time by wirelessly monitoring your
evacuations. Remotely view trending on the
Job Link mobile app so you know when an extra
nitrogen purge is required, a leak is suspected,
or just watch everything pull as planned.
Reduce the misleading nature of dynamic
vacuum measurement during pull down by
connecting MG44 directly to the system. The
reversible angled coupler makes it easy to orient
the gauge so that it's out of the way and easy
to see.
Select one of three unique views, including a
new Rate Meter that provides a great feel and
a Bar Graph that has a range up to atmosphere.
Built for demanding eld use, the overmolded
case resists damage from physical impact and
water ingress.
Maintenance
CLEANING: Clean the exterior with a damp
cloth. Do not use detergents or solvents.
SENSOR: Clean the sensor on a regular basis
to prevent the build up of oils and contaminents.
DO NOT use an object such as a cotton swab to
clean the sensor. This may damage the sensor.
1. Power o MG44.
2. If attached, remove the coupler from MG44 to expose the cavity of
the 1/4" male tting.
3. Fill up about half of the cavity with isopropyl (rubbing) alcohol or
AC system ush.
4. Cover the cavity and gently shake it for about 15-30 seconds.
5. Pour out the dirty solution and let the vacuum sensor dry with the
tting facing down.
BATTERIES: An empty battery icon
indicates batteries need to be replaced. When
power is too low to operate, "LoBatt" is displayed
5 sec before powering o automatically. You can
also monitor battery life in the Job Link app tool
manager.
1. Power o MG44.
2. Unscrew the battery cover (2 screws) and dispose of batteries
according to local law.
3. Install (2) new alkaline AA batteries.
4. Reinstall cover.
Wireless
Vacuum
Gauge
OPERATOR'S
MANUAL
Model MG44
Operation
Buttons
Unless muted, each button press triggers
a beep. An inactive button press triggers a
double beep.
Hold to toggle power.
Toggle backlight.
Silence alarm.
Hold to enter MENU.
Hold to exit MENU without saving.
ENTER selection.
Stop low alarm and start high alarm.
NEXT view.
NEXT menu item or increase value.
Hold to toggle ALARM mode.
Silence alarm.
Display
In standard operating mode, the top line
shows the live measurement. The bottom line
shows one of three selectable views.
: Auto Power O Enabled
: Battery Level
: Low Alarm
: High Alarm
: Muted
: Rate (dierential per minute)
: Wireless Enabled (shown at startup)
: Wireless Disabled (shown at startup)
Views
Press NEXT to change the content of the
bottom line. Each view provides a unique way
to monitor your evacuation.
RATE: The running 10-second average of the
measurement's change per minute. Negative
rates indicate the vacuum is getting deeper.
RATE METER: The graphical representation
of the measurement's real-time change per
minute. The scale is dynamic (i.e. relative to the
measurement) making changes easy to see.
Decreasing
Stable
Increasing
BAR GRAPH: The graphical representation
of the measurement. The scale is static and
nonlinear for increased resolution at deeper
vacuums. Full bars indicates atmospheric
pressure.
~3500 micronHg
Alarm Mode
Every evacuation is dierent. Some require
multiple purges of dry nitrogen, while some take
less time than a phone call. Activate alarm mode
so you can get other things handled without
babysitting your gauge.
Follow recommended evacuation practices
from the equipment manufacturer and training.
Alarm levels can be adjusted in the menu.
1. Hold ALARM to activate* low alarm (L).
Stopwatch starts. APO deactivates.
Turn on your vacuum pump.
2. Once the low alarm level is reached, the back-
light blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Isolate the vacuum pump from the system.
3. Press ENTER to activate high alarm (H).
Stopwatch restarts.
4. Once the high alarm level is reached, the
backlight blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Stopwatch stops.
5. Press ENTER to exit alarm mode.
APO reactivates.
* Hold ALARM to exit alarm mode at any time.
Specifications
Connector Type: 1/4'' SAE male tting. Includes reversible 1/4"
angled (45°) coupler with Schrader depressors.
Max Pressure: 870 psig (60 bar)
Refresh Rate: 0.5 seconds
Accuracy: ±(5% reading + 5 micron) at 77°F (25°C), 50 to 2000 micron
Measurement Range and Units:
50 to 25000 micronHg (mTorr); 0.05 to 25 mmHg (Torr);
6 to 3333 Pascals; 0.06 to 33.33 mBar
Bar Graph Range: ultimate vacuum to atmospheric pressure
Best Resolution:
1 micronHg(mTorr), below 2000; 0.001 mmHg (Torr), below 2.5;
1 Pascal, below 250; 0.001 mBar, below 2.5;
Battery Type: 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6
Battery Life: 50 hours typical alkaline
Auto Power Off: 15 minutes default (APO adjustable)
Wireless Range: 1000 feet (305 meters) line of sight.
Obstructions aect distance.
Radio Frequency: 2.4 GHz
Wireless Device Requirements:
(Latest compatibility and firmware at www.fieldpiece.com)
Job Link® app: BLE 4.0 devices with iOS® 7.0 or Android™ 5.0
SMANTM manifold: Models SM380V/SM480V with latest
rmware installed.
Water Resistance: IP54
Operating Environment: 14°F to 122°F (-10°C to 50°C) at
<75%RH
Storage Temperature: -4°F to 140°F (-20°C to 60°C) at <80%RH
(with batteries removed)
Weight: 0.66 lbs (300 g)
US Patent: www.eldpiece.com/patents
!
WARNINGS
Disconnect MG44 from system before applying pressure; pressures above
870 psig (60 bar) can damage the vacuum gauge.
Hand tighten ttings; overtightening may damage seals.
Follow all equipment manufacturer’s testing procedures above those in
this manual in regards to properly servicing their equipment.

01
06
02
07
03
08
04
09
05
10
Wireless Vacuum Gauge
MG44
NEXT
ALARM
ENTER
MENU
GASKETS: Each end of the coupler is sealed
by a black rubber gasket. These may become
worn over time due to overtightening or
connecting to damaged male ttings.
1. Use needle nose pliers or a similar tool to unscrew the Schrader
valve depressor from the gasket.
2. Remove and replace the worn gasket.
3. Screw the depressor back into the gasket.
Reversible Coupler
It's best to avoid using a hose to connect
your vacuum gauge to the system. The coupler
makes it easy to connect the gauge directly to a
service port or valve core removal tool.
Each end has a valve depressor and gasket so
you can ip the coupler to best t the system
and your viewing angle. Rotate and tighten
each end independently for optimal viewing
and control.
Quick Start
1. Unscrew the battery cover and install (2) AA
alkaline batteries.
2. Hold
MENU
ENTER
ALARM
NEXT
to power on.
Wireless setting is briefly displayed (ON/OFF).
Activate wireless in the menu to send measure-
ments to compatible Job Link® system tools.
3. Connecttotheequipmentyou'reevacuating.
Connect directly to an unused service port or to
a Schrader valve core removal tool.
4. View the live measurement on the top line.
5. Press NEXT to change bottom line view.
What's Included
(1) MG44 Wireless Vacuum Gauge
(1) Reversible 1/4" angled (45°) coupler
(2) AA Batteries
(1) Operator's manual
(1) Year limited warranty
Description
Use the MG44 Wireless Vacuum Gauge
to reliably monitor your evacuations in the
eld. Long range wireless technology sends
deep vacuum measurements up to 1000 feet
(305 meters) away. View live on your SMANTM
manifold, in the Job Link® mobile app, or directly
on the MG44.
Save time by wirelessly monitoring your
evacuations. Remotely view trending on the
Job Link mobile app so you know when an extra
nitrogen purge is required, a leak is suspected,
or just watch everything pull as planned.
Reduce the misleading nature of dynamic
vacuum measurement during pull down by
connecting MG44 directly to the system. The
reversible angled coupler makes it easy to orient
the gauge so that it's out of the way and easy
to see.
Select one of three unique views, including a
new Rate Meter that provides a great feel and
a Bar Graph that has a range up to atmosphere.
Built for demanding eld use, the overmolded
case resists damage from physical impact and
water ingress.
Maintenance
CLEANING: Clean the exterior with a damp
cloth. Do not use detergents or solvents.
SENSOR: Clean the sensor on a regular basis
to prevent the build up of oils and contaminents.
DO NOT use an object such as a cotton swab to
clean the sensor. This may damage the sensor.
1. Power o MG44.
2. If attached, remove the coupler from MG44 to expose the cavity of
the 1/4" male tting.
3. Fill up about half of the cavity with isopropyl (rubbing) alcohol or
AC system ush.
4. Cover the cavity and gently shake it for about 15-30 seconds.
5. Pour out the dirty solution and let the vacuum sensor dry with the
tting facing down.
BATTERIES: An empty battery icon
indicates batteries need to be replaced. When
power is too low to operate, "LoBatt" is displayed
5 sec before powering o automatically.You can
also monitor battery life in the Job Link app tool
manager.
1. Power o MG44.
2. Unscrew the battery cover (2 screws) and dispose of batteries
according to local law.
3. Install (2) new alkaline AA batteries.
4. Reinstall cover.
Wireless
Vacuum
Gauge
OPERATOR'S
MANUAL
Model MG44
Operation
Buttons
Unless muted, each button press triggers
a beep. An inactive button press triggers a
double beep.
Hold to toggle power.
Toggle backlight.
Silence alarm.
Hold to enter MENU.
Hold to exit MENU without saving.
ENTER selection.
Stop low alarm and start high alarm.
NEXT view.
NEXT menu item or increase value.
Hold to toggle ALARM mode.
Silence alarm.
Display
In standard operating mode, the top line
shows the live measurement. The bottom line
shows one of three selectable views.
: Auto Power O Enabled
: Battery Level
: Low Alarm
: High Alarm
: Muted
: Rate (dierential per minute)
: Wireless Enabled (shown at startup)
: Wireless Disabled (shown at startup)
Views
Press NEXT to change the content of the
bottom line. Each view provides a unique way
to monitor your evacuation.
RATE: The running 10-second average of the
measurement's change per minute. Negative
rates indicate the vacuum is getting deeper.
RATE METER: The graphical representation
of the measurement's real-time change per
minute. The scale is dynamic (i.e. relative to the
measurement) making changes easy to see.
Decreasing
Stable
Increasing
BAR GRAPH: The graphical representation
of the measurement. The scale is static and
nonlinear for increased resolution at deeper
vacuums. Full bars indicates atmospheric
pressure.
~3500 micronHg
Alarm Mode
Every evacuation is dierent. Some require
multiple purges of dry nitrogen, while some take
less time than a phone call. Activate alarm mode
so you can get other things handled without
babysitting your gauge.
Follow recommended evacuation practices
from the equipment manufacturer and training.
Alarm levels can be adjusted in the menu.
1. Hold ALARM to activate* low alarm (L).
Stopwatch starts. APO deactivates.
Turn on your vacuum pump.
2. Once the low alarm level is reached, the back-
light blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Isolate the vacuum pump from the system.
3. Press ENTER to activate high alarm (H).
Stopwatch restarts.
4. Once the high alarm level is reached, the
backlight blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Stopwatch stops.
5. Press ENTER to exit alarm mode.
APO reactivates.
* Hold ALARM to exit alarm mode at any time.
Specifications
Connector Type: 1/4'' SAE male tting. Includes reversible 1/4"
angled (45°) coupler with Schrader depressors.
Max Pressure: 870 psig (60 bar)
Refresh Rate: 0.5 seconds
Accuracy: ±(5% reading + 5 micron) at 77°F (25°C), 50 to 2000 micron
Measurement Range and Units:
50 to 25000 micronHg (mTorr); 0.05 to 25 mmHg (Torr);
6 to 3333 Pascals; 0.06 to 33.33 mBar
Bar Graph Range: ultimate vacuum to atmospheric pressure
Best Resolution:
1 micronHg(mTorr), below 2000; 0.001 mmHg (Torr), below 2.5;
1 Pascal, below 250; 0.001 mBar, below 2.5;
Battery Type: 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6
Battery Life: 50 hours typical alkaline
Auto Power Off: 15 minutes default (APO adjustable)
Wireless Range: 1000 feet (305 meters) line of sight.
Obstructions aect distance.
Radio Frequency: 2.4 GHz
Wireless Device Requirements:
(Latest compatibility and firmware at www.fieldpiece.com)
Job Link® app: BLE 4.0 devices with iOS® 7.0 or Android™ 5.0
SMANTM manifold: Models SM380V/SM480V with latest
rmware installed.
Water Resistance: IP54
Operating Environment: 14°F to 122°F (-10°C to 50°C) at
<75%RH
Storage Temperature: -4°F to 140°F (-20°C to 60°C) at <80%RH
(with batteries removed)
Weight: 0.66 lbs (300 g)
US Patent: www.eldpiece.com/patents
!
WARNINGS
Disconnect MG44 from system before applying pressure; pressures above
870 psig (60 bar) can damage the vacuum gauge.
Hand tighten ttings; overtightening may damage seals.
Follow all equipment manufacturer’s testing procedures above those in
this manual in regards to properly servicing their equipment.

01
06
02
07
03
08
04
09
05
10
Wireless Vacuum Gauge
MG44
NEXT
ALARM
ENTER
MENU
GASKETS: Each end of the coupler is sealed
by a black rubber gasket. These may become
worn over time due to overtightening or
connecting to damaged male ttings.
1. Use needle nose pliers or a similar tool to unscrew the Schrader
valve depressor from the gasket.
2. Remove and replace the worn gasket.
3. Screw the depressor back into the gasket.
Reversible Coupler
It's best to avoid using a hose to connect
your vacuum gauge to the system. The coupler
makes it easy to connect the gauge directly to a
service port or valve core removal tool.
Each end has a valve depressor and gasket so
you can ip the coupler to best t the system
and your viewing angle. Rotate and tighten
each end independently for optimal viewing
and control.
Quick Start
1. Unscrew the battery cover and install (2) AA
alkaline batteries.
2. Hold
MENU
ENTER
ALARM
NEXT
to power on.
Wireless setting is briefly displayed (ON/OFF).
Activate wireless in the menu to send measure-
ments to compatible Job Link® system tools.
3. Connecttotheequipmentyou'reevacuating.
Connect directly to an unused service port or to
a Schrader valve core removal tool.
4. View the live measurement on the top line.
5. Press NEXT to change bottom line view.
What's Included
(1) MG44 Wireless Vacuum Gauge
(1) Reversible 1/4" angled (45°) coupler
(2) AA Batteries
(1) Operator's manual
(1) Year limited warranty
Description
Use the MG44 Wireless Vacuum Gauge
to reliably monitor your evacuations in the
eld. Long range wireless technology sends
deep vacuum measurements up to 1000 feet
(305 meters) away. View live on your SMANTM
manifold, in the Job Link® mobile app, or directly
on the MG44.
Save time by wirelessly monitoring your
evacuations. Remotely view trending on the
Job Link mobile app so you know when an extra
nitrogen purge is required, a leak is suspected,
or just watch everything pull as planned.
Reduce the misleading nature of dynamic
vacuum measurement during pull down by
connecting MG44 directly to the system. The
reversible angled coupler makes it easy to orient
the gauge so that it's out of the way and easy
to see.
Select one of three unique views, including a
new Rate Meter that provides a great feel and
a Bar Graph that has a range up to atmosphere.
Built for demanding eld use, the overmolded
case resists damage from physical impact and
water ingress.
Maintenance
CLEANING: Clean the exterior with a damp
cloth. Do not use detergents or solvents.
SENSOR: Clean the sensor on a regular basis
to prevent the build up of oils and contaminents.
DO NOT use an object such as a cotton swab to
clean the sensor. This may damage the sensor.
1. Power o MG44.
2. If attached, remove the coupler from MG44 to expose the cavity of
the 1/4" male tting.
3. Fill up about half of the cavity with isopropyl (rubbing) alcohol or
AC system ush.
4. Cover the cavity and gently shake it for about 15-30 seconds.
5. Pour out the dirty solution and let the vacuum sensor dry with the
tting facing down.
BATTERIES: An empty battery icon
indicates batteries need to be replaced. When
power is too low to operate, "LoBatt" is displayed
5 sec before powering o automatically.You can
also monitor battery life in the Job Link app tool
manager.
1. Power o MG44.
2. Unscrew the battery cover (2 screws) and dispose of batteries
according to local law.
3. Install (2) new alkaline AA batteries.
4. Reinstall cover.
Wireless
Vacuum
Gauge
OPERATOR'S
MANUAL
Model MG44
Operation
Buttons
Unless muted, each button press triggers
a beep. An inactive button press triggers a
double beep.
Hold to toggle power.
Toggle backlight.
Silence alarm.
Hold to enter MENU.
Hold to exit MENU without saving.
ENTER selection.
Stop low alarm and start high alarm.
NEXT view.
NEXT menu item or increase value.
Hold to toggle ALARM mode.
Silence alarm.
Display
In standard operating mode, the top line
shows the live measurement. The bottom line
shows one of three selectable views.
: Auto Power O Enabled
: Battery Level
: Low Alarm
: High Alarm
: Muted
: Rate (dierential per minute)
: Wireless Enabled (shown at startup)
: Wireless Disabled (shown at startup)
Views
Press NEXT to change the content of the
bottom line. Each view provides a unique way
to monitor your evacuation.
RATE: The running 10-second average of the
measurement's change per minute. Negative
rates indicate the vacuum is getting deeper.
RATE METER: The graphical representation
of the measurement's real-time change per
minute. The scale is dynamic (i.e. relative to the
measurement) making changes easy to see.
Decreasing
Stable
Increasing
BAR GRAPH: The graphical representation
of the measurement. The scale is static and
nonlinear for increased resolution at deeper
vacuums. Full bars indicates atmospheric
pressure.
~3500 micronHg
Alarm Mode
Every evacuation is dierent. Some require
multiple purges of dry nitrogen, while some take
less time than a phone call. Activate alarm mode
so you can get other things handled without
babysitting your gauge.
Follow recommended evacuation practices
from the equipment manufacturer and training.
Alarm levels can be adjusted in the menu.
1. Hold ALARM to activate* low alarm (L).
Stopwatch starts. APO deactivates.
Turn on your vacuum pump.
2. Once the low alarm level is reached, the back-
light blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Isolate the vacuum pump from the system.
3. Press ENTER to activate high alarm (H).
Stopwatch restarts.
4. Once the high alarm level is reached, the
backlight blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Stopwatch stops.
5. Press ENTER to exit alarm mode.
APO reactivates.
* Hold ALARM to exit alarm mode at any time.
Specifications
Connector Type: 1/4'' SAE male tting. Includes reversible 1/4"
angled (45°) coupler with Schrader depressors.
Max Pressure: 870 psig (60 bar)
Refresh Rate: 0.5 seconds
Accuracy: ±(5% reading + 5 micron) at 77°F (25°C), 50 to 2000 micron
Measurement Range and Units:
50 to 25000 micronHg (mTorr); 0.05 to 25 mmHg (Torr);
6 to 3333 Pascals; 0.06 to 33.33 mBar
Bar Graph Range: ultimate vacuum to atmospheric pressure
Best Resolution:
1 micronHg(mTorr), below 2000; 0.001 mmHg (Torr), below 2.5;
1 Pascal, below 250; 0.001 mBar, below 2.5;
Battery Type: 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6
Battery Life: 50 hours typical alkaline
Auto Power Off: 15 minutes default (APO adjustable)
Wireless Range: 1000 feet (305 meters) line of sight.
Obstructions aect distance.
Radio Frequency: 2.4 GHz
Wireless Device Requirements:
(Latest compatibility and firmware at www.fieldpiece.com)
Job Link® app: BLE 4.0 devices with iOS® 7.0 or Android™ 5.0
SMANTM manifold: Models SM380V/SM480V with latest
rmware installed.
Water Resistance: IP54
Operating Environment: 14°F to 122°F (-10°C to 50°C) at
<75%RH
Storage Temperature: -4°F to 140°F (-20°C to 60°C) at <80%RH
(with batteries removed)
Weight: 0.66 lbs (300 g)
US Patent: www.eldpiece.com/patents
!
WARNINGS
Disconnect MG44 from system before applying pressure; pressures above
870 psig (60 bar) can damage the vacuum gauge.
Hand tighten ttings; overtightening may damage seals.
Follow all equipment manufacturer’s testing procedures above those in
this manual in regards to properly servicing their equipment.

01
06
02
07
03
08
04
09
05
10
Wireless Vacuum Gauge
MG44
NEXT
ALARM
ENTER
MENU
GASKETS: Each end of the coupler is sealed
by a black rubber gasket. These may become
worn over time due to overtightening or
connecting to damaged male ttings.
1. Use needle nose pliers or a similar tool to unscrew the Schrader
valve depressor from the gasket.
2. Remove and replace the worn gasket.
3. Screw the depressor back into the gasket.
Reversible Coupler
It's best to avoid using a hose to connect
your vacuum gauge to the system. The coupler
makes it easy to connect the gauge directly to a
service port or valve core removal tool.
Each end has a valve depressor and gasket so
you can ip the coupler to best t the system
and your viewing angle. Rotate and tighten
each end independently for optimal viewing
and control.
Quick Start
1. Unscrew the battery cover and install (2) AA
alkaline batteries.
2. Hold
MENU
ENTER
ALARM
NEXT
to power on.
Wireless setting is briefly displayed (ON/OFF).
Activate wireless in the menu to send measure-
ments to compatible Job Link® system tools.
3. Connecttotheequipmentyou'reevacuating.
Connect directly to an unused service port or to
a Schrader valve core removal tool.
4. View the live measurement on the top line.
5. Press NEXT to change bottom line view.
What's Included
(1) MG44 Wireless Vacuum Gauge
(1) Reversible 1/4" angled (45°) coupler
(2) AA Batteries
(1) Operator's manual
(1) Year limited warranty
Description
Use the MG44 Wireless Vacuum Gauge
to reliably monitor your evacuations in the
eld. Long range wireless technology sends
deep vacuum measurements up to 1000 feet
(305 meters) away. View live on your SMANTM
manifold, in the Job Link® mobile app, or directly
on the MG44.
Save time by wirelessly monitoring your
evacuations. Remotely view trending on the
Job Link mobile app so you know when an extra
nitrogen purge is required, a leak is suspected,
or just watch everything pull as planned.
Reduce the misleading nature of dynamic
vacuum measurement during pull down by
connecting MG44 directly to the system. The
reversible angled coupler makes it easy to orient
the gauge so that it's out of the way and easy
to see.
Select one of three unique views, including a
new Rate Meter that provides a great feel and
a Bar Graph that has a range up to atmosphere.
Built for demanding eld use, the overmolded
case resists damage from physical impact and
water ingress.
Maintenance
CLEANING: Clean the exterior with a damp
cloth. Do not use detergents or solvents.
SENSOR: Clean the sensor on a regular basis
to prevent the build up of oils and contaminents.
DO NOT use an object such as a cotton swab to
clean the sensor. This may damage the sensor.
1. Power o MG44.
2. If attached, remove the coupler from MG44 to expose the cavity of
the 1/4" male tting.
3. Fill up about half of the cavity with isopropyl (rubbing) alcohol or
AC system ush.
4. Cover the cavity and gently shake it for about 15-30 seconds.
5. Pour out the dirty solution and let the vacuum sensor dry with the
tting facing down.
BATTERIES: An empty battery icon
indicates batteries need to be replaced. When
power is too low to operate, "LoBatt" is displayed
5 sec before powering o automatically.You can
also monitor battery life in the Job Link app tool
manager.
1. Power o MG44.
2. Unscrew the battery cover (2 screws) and dispose of batteries
according to local law.
3. Install (2) new alkaline AA batteries.
4. Reinstall cover.
Wireless
Vacuum
Gauge
OPERATOR'S
MANUAL
Model MG44
Operation
Buttons
Unless muted, each button press triggers
a beep. An inactive button press triggers a
double beep.
Hold to toggle power.
Toggle backlight.
Silence alarm.
Hold to enter MENU.
Hold to exit MENU without saving.
ENTER selection.
Stop low alarm and start high alarm.
NEXT view.
NEXT menu item or increase value.
Hold to toggle ALARM mode.
Silence alarm.
Display
In standard operating mode, the top line
shows the live measurement. The bottom line
shows one of three selectable views.
: Auto Power O Enabled
: Battery Level
: Low Alarm
: High Alarm
: Muted
: Rate (dierential per minute)
: Wireless Enabled (shown at startup)
: Wireless Disabled (shown at startup)
Views
Press NEXT to change the content of the
bottom line. Each view provides a unique way
to monitor your evacuation.
RATE: The running 10-second average of the
measurement's change per minute. Negative
rates indicate the vacuum is getting deeper.
RATE METER: The graphical representation
of the measurement's real-time change per
minute. The scale is dynamic (i.e. relative to the
measurement) making changes easy to see.
Decreasing
Stable
Increasing
BAR GRAPH: The graphical representation
of the measurement. The scale is static and
nonlinear for increased resolution at deeper
vacuums. Full bars indicates atmospheric
pressure.
~3500 micronHg
Alarm Mode
Every evacuation is dierent. Some require
multiple purges of dry nitrogen, while some take
less time than a phone call. Activate alarm mode
so you can get other things handled without
babysitting your gauge.
Follow recommended evacuation practices
from the equipment manufacturer and training.
Alarm levels can be adjusted in the menu.
1. Hold ALARM to activate* low alarm (L).
Stopwatch starts. APO deactivates.
Turn on your vacuum pump.
2. Once the low alarm level is reached, the back-
light blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Isolate the vacuum pump from the system.
3. Press ENTER to activate high alarm (H).
Stopwatch restarts.
4. Once the high alarm level is reached, the
backlight blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Stopwatch stops.
5. Press ENTER to exit alarm mode.
APO reactivates.
* Hold ALARM to exit alarm mode at any time.
Specifications
Connector Type: 1/4'' SAE male tting. Includes reversible 1/4"
angled (45°) coupler with Schrader depressors.
Max Pressure: 870 psig (60 bar)
Refresh Rate: 0.5 seconds
Accuracy: ±(5% reading + 5 micron) at 77°F (25°C), 50 to 2000 micron
Measurement Range and Units:
50 to 25000 micronHg (mTorr); 0.05 to 25 mmHg (Torr);
6 to 3333 Pascals; 0.06 to 33.33 mBar
Bar Graph Range: ultimate vacuum to atmospheric pressure
Best Resolution:
1 micronHg(mTorr), below 2000; 0.001 mmHg (Torr), below 2.5;
1 Pascal, below 250; 0.001 mBar, below 2.5;
Battery Type: 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6
Battery Life: 50 hours typical alkaline
Auto Power Off: 15 minutes default (APO adjustable)
Wireless Range: 1000 feet (305 meters) line of sight.
Obstructions aect distance.
Radio Frequency: 2.4 GHz
Wireless Device Requirements:
(Latest compatibility and firmware at www.fieldpiece.com)
Job Link® app: BLE 4.0 devices with iOS® 7.0 or Android™ 5.0
SMANTM manifold: Models SM380V/SM480V with latest
rmware installed.
Water Resistance: IP54
Operating Environment: 14°F to 122°F (-10°C to 50°C) at
<75%RH
Storage Temperature: -4°F to 140°F (-20°C to 60°C) at <80%RH
(with batteries removed)
Weight: 0.66 lbs (300 g)
US Patent: www.eldpiece.com/patents
!
WARNINGS
Disconnect MG44 from system before applying pressure; pressures above
870 psig (60 bar) can damage the vacuum gauge.
Hand tighten ttings; overtightening may damage seals.
Follow all equipment manufacturer’s testing procedures above those in
this manual in regards to properly servicing their equipment.

01
06
02
07
03
08
04
09
05
10
Wireless Vacuum Gauge
MG44
NEXT
ALARM
ENTER
MENU
GASKETS: Each end of the coupler is sealed
by a black rubber gasket. These may become
worn over time due to overtightening or
connecting to damaged male ttings.
1. Use needle nose pliers or a similar tool to unscrew the Schrader
valve depressor from the gasket.
2. Remove and replace the worn gasket.
3. Screw the depressor back into the gasket.
Reversible Coupler
It's best to avoid using a hose to connect
your vacuum gauge to the system. The coupler
makes it easy to connect the gauge directly to a
service port or valve core removal tool.
Each end has a valve depressor and gasket so
you can ip the coupler to best t the system
and your viewing angle. Rotate and tighten
each end independently for optimal viewing
and control.
Quick Start
1. Unscrew the battery cover and install (2) AA
alkaline batteries.
2. Hold
MENU
ENTER
ALARM
NEXT
to power on.
Wireless setting is briefly displayed (ON/OFF).
Activate wireless in the menu to send measure-
ments to compatible Job Link® system tools.
3. Connecttotheequipmentyou'reevacuating.
Connect directly to an unused service port or to
a Schrader valve core removal tool.
4. View the live measurement on the top line.
5. Press NEXT to change bottom line view.
What's Included
(1) MG44 Wireless Vacuum Gauge
(1) Reversible 1/4" angled (45°) coupler
(2) AA Batteries
(1) Operator's manual
(1) Year limited warranty
Description
Use the MG44 Wireless Vacuum Gauge
to reliably monitor your evacuations in the
eld. Long range wireless technology sends
deep vacuum measurements up to 1000 feet
(305 meters) away. View live on your SMANTM
manifold, in the Job Link® mobile app, or directly
on the MG44.
Save time by wirelessly monitoring your
evacuations. Remotely view trending on the
Job Link mobile app so you know when an extra
nitrogen purge is required, a leak is suspected,
or just watch everything pull as planned.
Reduce the misleading nature of dynamic
vacuum measurement during pull down by
connecting MG44 directly to the system. The
reversible angled coupler makes it easy to orient
the gauge so that it's out of the way and easy
to see.
Select one of three unique views, including a
new Rate Meter that provides a great feel and
a Bar Graph that has a range up to atmosphere.
Built for demanding eld use, the overmolded
case resists damage from physical impact and
water ingress.
Maintenance
CLEANING: Clean the exterior with a damp
cloth. Do not use detergents or solvents.
SENSOR: Clean the sensor on a regular basis
to prevent the build up of oils and contaminents.
DO NOT use an object such as a cotton swab to
clean the sensor. This may damage the sensor.
1. Power o MG44.
2. If attached, remove the coupler from MG44 to expose the cavity of
the 1/4" male tting.
3. Fill up about half of the cavity with isopropyl (rubbing) alcohol or
AC system ush.
4. Cover the cavity and gently shake it for about 15-30 seconds.
5. Pour out the dirty solution and let the vacuum sensor dry with the
tting facing down.
BATTERIES: An empty battery icon
indicates batteries need to be replaced. When
power is too low to operate, "LoBatt" is displayed
5 sec before powering o automatically.You can
also monitor battery life in the Job Link app tool
manager.
1. Power o MG44.
2. Unscrew the battery cover (2 screws) and dispose of batteries
according to local law.
3. Install (2) new alkaline AA batteries.
4. Reinstall cover.
Wireless
Vacuum
Gauge
OPERATOR'S
MANUAL
Model MG44
Operation
Buttons
Unless muted, each button press triggers
a beep. An inactive button press triggers a
double beep.
Hold to toggle power.
Toggle backlight.
Silence alarm.
Hold to enter MENU.
Hold to exit MENU without saving.
ENTER selection.
Stop low alarm and start high alarm.
NEXT view.
NEXT menu item or increase value.
Hold to toggle ALARM mode.
Silence alarm.
Display
In standard operating mode, the top line
shows the live measurement. The bottom line
shows one of three selectable views.
: Auto Power O Enabled
: Battery Level
: Low Alarm
: High Alarm
: Muted
: Rate (dierential per minute)
: Wireless Enabled (shown at startup)
: Wireless Disabled (shown at startup)
Views
Press NEXT to change the content of the
bottom line. Each view provides a unique way
to monitor your evacuation.
RATE: The running 10-second average of the
measurement's change per minute. Negative
rates indicate the vacuum is getting deeper.
RATE METER: The graphical representation
of the measurement's real-time change per
minute. The scale is dynamic (i.e. relative to the
measurement) making changes easy to see.
Decreasing
Stable
Increasing
BAR GRAPH: The graphical representation
of the measurement. The scale is static and
nonlinear for increased resolution at deeper
vacuums. Full bars indicates atmospheric
pressure.
~3500 micronHg
Alarm Mode
Every evacuation is dierent. Some require
multiple purges of dry nitrogen, while some take
less time than a phone call. Activate alarm mode
so you can get other things handled without
babysitting your gauge.
Follow recommended evacuation practices
from the equipment manufacturer and training.
Alarm levels can be adjusted in the menu.
1. Hold ALARM to activate* low alarm (L).
Stopwatch starts. APO deactivates.
Turn on your vacuum pump.
2. Once the low alarm level is reached, the back-
light blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Isolate the vacuum pump from the system.
3. Press ENTER to activate high alarm (H).
Stopwatch restarts.
4. Once the high alarm level is reached, the
backlight blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Stopwatch stops.
5. Press ENTER to exit alarm mode.
APO reactivates.
* Hold ALARM to exit alarm mode at any time.
Specifications
Connector Type: 1/4'' SAE male tting. Includes reversible 1/4"
angled (45°) coupler with Schrader depressors.
Max Pressure: 870 psig (60 bar)
Refresh Rate: 0.5 seconds
Accuracy: ±(5% reading + 5 micron) at 77°F (25°C), 50 to 2000 micron
Measurement Range and Units:
50 to 25000 micronHg (mTorr); 0.05 to 25 mmHg (Torr);
6 to 3333 Pascals; 0.06 to 33.33 mBar
Bar Graph Range: ultimate vacuum to atmospheric pressure
Best Resolution:
1 micronHg(mTorr), below 2000; 0.001 mmHg (Torr), below 2.5;
1 Pascal, below 250; 0.001 mBar, below 2.5;
Battery Type: 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6
Battery Life: 50 hours typical alkaline
Auto Power Off: 15 minutes default (APO adjustable)
Wireless Range: 1000 feet (305 meters) line of sight.
Obstructions aect distance.
Radio Frequency: 2.4 GHz
Wireless Device Requirements:
(Latest compatibility and firmware at www.fieldpiece.com)
Job Link® app: BLE 4.0 devices with iOS® 7.0 or Android™ 5.0
SMANTM manifold: Models SM380V/SM480V with latest
rmware installed.
Water Resistance: IP54
Operating Environment: 14°F to 122°F (-10°C to 50°C) at
<75%RH
Storage Temperature: -4°F to 140°F (-20°C to 60°C) at <80%RH
(with batteries removed)
Weight: 0.66 lbs (300 g)
US Patent: www.eldpiece.com/patents
!
WARNINGS
Disconnect MG44 from system before applying pressure; pressures above
870 psig (60 bar) can damage the vacuum gauge.
Hand tighten ttings; overtightening may damage seals.
Follow all equipment manufacturer’s testing procedures above those in
this manual in regards to properly servicing their equipment.

01
06
02
07
03
08
04
09
05
10
Wireless Vacuum Gauge
MG44
NEXT
ALARM
ENTER
MENU
GASKETS: Each end of the coupler is sealed
by a black rubber gasket. These may become
worn over time due to overtightening or
connecting to damaged male ttings.
1. Use needle nose pliers or a similar tool to unscrew the Schrader
valve depressor from the gasket.
2. Remove and replace the worn gasket.
3. Screw the depressor back into the gasket.
Reversible Coupler
It's best to avoid using a hose to connect
your vacuum gauge to the system. The coupler
makes it easy to connect the gauge directly to a
service port or valve core removal tool.
Each end has a valve depressor and gasket so
you can ip the coupler to best t the system
and your viewing angle. Rotate and tighten
each end independently for optimal viewing
and control.
Quick Start
1. Unscrew the battery cover and install (2) AA
alkaline batteries.
2. Hold
MENU
ENTER
ALARM
NEXT
to power on.
Wireless setting is briefly displayed (ON/OFF).
Activate wireless in the menu to send measure-
ments to compatible Job Link® system tools.
3. Connecttotheequipmentyou'reevacuating.
Connect directly to an unused service port or to
a Schrader valve core removal tool.
4. View the live measurement on the top line.
5. Press NEXT to change bottom line view.
What's Included
(1) MG44 Wireless Vacuum Gauge
(1) Reversible 1/4" angled (45°) coupler
(2) AA Batteries
(1) Operator's manual
(1) Year limited warranty
Description
Use the MG44 Wireless Vacuum Gauge
to reliably monitor your evacuations in the
eld. Long range wireless technology sends
deep vacuum measurements up to 1000 feet
(305 meters) away. View live on your SMANTM
manifold, in the Job Link® mobile app, or directly
on the MG44.
Save time by wirelessly monitoring your
evacuations. Remotely view trending on the
Job Link mobile app so you know when an extra
nitrogen purge is required, a leak is suspected,
or just watch everything pull as planned.
Reduce the misleading nature of dynamic
vacuum measurement during pull down by
connecting MG44 directly to the system. The
reversible angled coupler makes it easy to orient
the gauge so that it's out of the way and easy
to see.
Select one of three unique views, including a
new Rate Meter that provides a great feel and
a Bar Graph that has a range up to atmosphere.
Built for demanding eld use, the overmolded
case resists damage from physical impact and
water ingress.
Maintenance
CLEANING: Clean the exterior with a damp
cloth. Do not use detergents or solvents.
SENSOR: Clean the sensor on a regular basis
to prevent the build up of oils and contaminents.
DO NOT use an object such as a cotton swab to
clean the sensor. This may damage the sensor.
1. Power o MG44.
2. If attached, remove the coupler from MG44 to expose the cavity of
the 1/4" male tting.
3. Fill up about half of the cavity with isopropyl (rubbing) alcohol or
AC system ush.
4. Cover the cavity and gently shake it for about 15-30 seconds.
5. Pour out the dirty solution and let the vacuum sensor dry with the
tting facing down.
BATTERIES: An empty battery icon
indicates batteries need to be replaced. When
power is too low to operate, "LoBatt" is displayed
5 sec before powering o automatically.You can
also monitor battery life in the Job Link app tool
manager.
1. Power o MG44.
2. Unscrew the battery cover (2 screws) and dispose of batteries
according to local law.
3. Install (2) new alkaline AA batteries.
4. Reinstall cover.
Wireless
Vacuum
Gauge
OPERATOR'S
MANUAL
Model MG44
Operation
Buttons
Unless muted, each button press triggers
a beep. An inactive button press triggers a
double beep.
Hold to toggle power.
Toggle backlight.
Silence alarm.
Hold to enter MENU.
Hold to exit MENU without saving.
ENTER selection.
Stop low alarm and start high alarm.
NEXT view.
NEXT menu item or increase value.
Hold to toggle ALARM mode.
Silence alarm.
Display
In standard operating mode, the top line
shows the live measurement. The bottom line
shows one of three selectable views.
: Auto Power O Enabled
: Battery Level
: Low Alarm
: High Alarm
: Muted
: Rate (dierential per minute)
: Wireless Enabled (shown at startup)
: Wireless Disabled (shown at startup)
Views
Press NEXT to change the content of the
bottom line. Each view provides a unique way
to monitor your evacuation.
RATE: The running 10-second average of the
measurement's change per minute. Negative
rates indicate the vacuum is getting deeper.
RATE METER: The graphical representation
of the measurement's real-time change per
minute. The scale is dynamic (i.e. relative to the
measurement) making changes easy to see.
Decreasing
Stable
Increasing
BAR GRAPH: The graphical representation
of the measurement. The scale is static and
nonlinear for increased resolution at deeper
vacuums. Full bars indicates atmospheric
pressure.
~3500 micronHg
Alarm Mode
Every evacuation is dierent. Some require
multiple purges of dry nitrogen, while some take
less time than a phone call. Activate alarm mode
so you can get other things handled without
babysitting your gauge.
Follow recommended evacuation practices
from the equipment manufacturer and training.
Alarm levels can be adjusted in the menu.
1. Hold ALARM to activate* low alarm (L).
Stopwatch starts. APO deactivates.
Turn on your vacuum pump.
2. Once the low alarm level is reached, the back-
light blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Isolate the vacuum pump from the system.
3. Press ENTER to activate high alarm (H).
Stopwatch restarts.
4. Once the high alarm level is reached, the
backlight blinks and the alarm sounds.
To silence the alarm, press
MENU
ENTER
ALARM
NEXT
or NEXT.
Stopwatch stops.
5. Press ENTER to exit alarm mode.
APO reactivates.
* Hold ALARM to exit alarm mode at any time.
Specifications
Connector Type: 1/4'' SAE male tting. Includes reversible 1/4"
angled (45°) coupler with Schrader depressors.
Max Pressure: 870 psig (60 bar)
Refresh Rate: 0.5 seconds
Accuracy: ±(5% reading + 5 micron) at 77°F (25°C), 50 to 2000 micron
Measurement Range and Units:
50 to 25000 micronHg (mTorr); 0.05 to 25 mmHg (Torr);
6 to 3333 Pascals; 0.06 to 33.33 mBar
Bar Graph Range: ultimate vacuum to atmospheric pressure
Best Resolution:
1 micronHg(mTorr), below 2000; 0.001 mmHg (Torr), below 2.5;
1 Pascal, below 250; 0.001 mBar, below 2.5;
Battery Type: 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6
Battery Life: 50 hours typical alkaline
Auto Power Off: 15 minutes default (APO adjustable)
Wireless Range: 1000 feet (305 meters) line of sight.
Obstructions aect distance.
Radio Frequency: 2.4 GHz
Wireless Device Requirements:
(Latest compatibility and firmware at www.fieldpiece.com)
Job Link® app: BLE 4.0 devices with iOS® 7.0 or Android™ 5.0
SMANTM manifold: Models SM380V/SM480V with latest
rmware installed.
Water Resistance: IP54
Operating Environment: 14°F to 122°F (-10°C to 50°C) at
<75%RH
Storage Temperature: -4°F to 140°F (-20°C to 60°C) at <80%RH
(with batteries removed)
Weight: 0.66 lbs (300 g)
US Patent: www.eldpiece.com/patents
!
WARNINGS
Disconnect MG44 from system before applying pressure; pressures above
870 psig (60 bar) can damage the vacuum gauge.
Hand tighten ttings; overtightening may damage seals.
Follow all equipment manufacturer’s testing procedures above those in
this manual in regards to properly servicing their equipment.

11
16
12
17
13
18
14
19
15
20
Settings Menu
The settings menu can be entered when
in standard operating mode. Selecting a new
setting automatically exits the menu.This saves
time getting in and out of the menu quickly
for your most commonly changed setting (e.g.
wireless).
1. Hold ENTER to enter* the settings menu.
The menu starts where you last exited.
2. Press NEXT to view next setting.
The menu loops so keep going if you skipped
the setting you want to change.
3. Press ENTER to select the setting.
4. Press NEXT to increase the setting value.
The setting values loop so keep going if you
skipped the value you want to save.
5. Press ENTER to save* the new value and exit.
*Hold ENTER to exit the menu without saving.
List of Settings
Start : Enable Wireless (if o)
Stop : Disable Wireless (if on)
Auto O : Set Auto O Timer
Units : Set Unit of Measure
Alarm Lo : Set Low Alarm Level
Alarm Hi : Set High Alarm Level
Mute : Enable Speaker (if o)
Unmute : Disable Speaker (if on)
BkLtTime : Set Backlight Timer
Firmware : View and Update Firmware
Restore : Restore Default Settings
Wireless
Start or stop sending wireless measurements.
Live measurements can be sent to SMAN
manifold (overrides its internal vacuum gauge),
and to the Job Link mobile app for added
capabilities such as live trending. Wireless is
disabled by default to maximize battery life.
Auto Power Off Timer (APO)
Set the timer for the gauge automatically
powering o. The timer is reset when a button
is pressed. The timer is disabled in alarm mode.
(15min, 30min, 45min, 60min, Disabled)
Units
Set the unit of vacuum measurement. Alarm
levels are automatically converted to match the
unit setting.
(Microns, Pascals, mBar, mTorr, Torr, mmHg)
Low Alarm Level ( )
Set the vacuum level required to trigger the
low alarm. Hold NEXT for quicker scrolling.
(50 - 500 - High Alarm)
High Alarm Level ( )
Set the vacuum level required to trigger the
high alarm. Hold NEXT for quicker scrolling.
(Low Alarm - 1000 - 9000)
Mute ( )
Mute or unmute the speaker. Button presses
and alarms remain silent if the speaker is muted.
The icon appears if the speaker is muted.
Backlight Timer
Set the timer for the backlight automatically
turning o. The timer is reset when a button is
pressed.
(10s,20s,1min,2min,5min,10min,15min,30min)
Firmware
Check the firmware version (X.XXX.X) by
reading the first 4 digits. If a new version is
available from the Job Link mobile app, initiate
the update from your mobile device.
Restore
To restore all settings to their factory defaults,
press NEXT until "YES" is displayed and press
ENTER to conrm. To exit without restoring,
select "no" or hold ENTER.
Evacuation Tips
MAXIMIZE FLOW
• Remove Schrader valve cores with a removal
tool.
• Remove valve depressors from hoses.
• Useshortestvacuumratedhoseswithlargest
diameter available.
• Do not evacuate through hoses with low loss
ttings.
TRUST YOUR TEST
• Inspect the rubber seals at both ends of your
hoses for damage. Replace as needed.
• Change pump oil before and during the job.
Change pump oil on-the-y without losing
vacuum with Fieldpiece vacuum pumps.
• When the vacuum pump is isolated from the
system, a slow rise that stabilizes may signify
moisture is still present in the system. A con-
tinuous rise to atmosphere indicates a leak.
Check hoses, tools, or the system itself.
• Measurements are less representative of the
entire system when the vacuum pump is on
because pumping creates a pressure gradi-
ent.Isolatethepump and allowthesystemto
stabilize before assuming the measurement
represents the entire system.
Certifications
and Module IDs
FCC Statement
This equipmenthas beentested and found to comply withthe limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if notinstalled andused in accordance with theinstructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the
interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit dierent from that
to which the receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or
modications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
(Example - use only shielded interface cables when connecting to
computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device complies with Industry Canada licence-exempt RSS-247
standard. Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference thatmay cause undesired operation
of the device.
IC Radiation Exposure Statement: This equipment complies
with IC RSS-102 radiation exposure limit set forth for an uncontrolled
environment. This equipment should be installed and operated with
minimum distance 0.5 cm between the radiator and your body.
Fieldpiece Instruments 1636 West Collins Avenue, Orange, CA 92867
IFETEL Statement
Laoperacióndeesteequipoestásujetaalassiguientesdoscondiciones:
(1) es posible que este equipo o dispositivo no cause interferencia
perjudicial y (2) este equipo o dispositivo debe aceptar cualquier
interferencia, incluyendo la que pueda causar su operación no deseada.
The operation of this equipment is subject to the following two
conditions: (1)this device or device maynot cause harmful interference,
and (2) this device or device must accept any interference, including
interference that may cause undesired operation.
ANATEL Statement
Este equipamento não tem direito à proteção contra interferência
prejudicial e não pode causar interferência em sistemas devidamente
autorizados.
This equipment is not subject to the protection from harmful
interference and may not cause interference with duly authorized
systems.
Limited Warranty
This product is warranted against defects in material and
workmanship for one year from date of purchase from an authorized
Fieldpiece dealer. Fieldpiece will replace or repair the defective unit,
at its option, subject to verication of the defect.
This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arisingfrom thesale of a Fieldpiece product,
including but not limited to implied warranties of merchantability and
tness for a particular purpose, are limited to the above. Fieldpiece
shall not be liable for loss of use of the instrument or other incidental
or consequential damages, expenses, or economic loss, or for any claim
of such damage, expenses, or economic loss.
State laws vary. The above limitations or exclusions may not apply
to you.
Obtaining Service
For international customers, warranty for products purchased
outside of the U.S. should be handled through local distributors. Visit
our website to nd your local distributor.
© Fieldpiece Instruments, Inc 2021; v01
EN 300 328
2ALHR003
00263-18-10972
IC: Industry Canada
22518-BT003
IFETEL: Federal Telecom Institute
RCPFI2A18-0235
Regulatory Compliance Mark
Waste Electrical and
Electronic Equipment
Restriction of Hazardous
Substances Compliant

11
16
12
17
13
18
14
19
15
20
Settings Menu
The settings menu can be entered when
in standard operating mode. Selecting a new
setting automatically exits the menu.This saves
time getting in and out of the menu quickly
for your most commonly changed setting (e.g.
wireless).
1. Hold ENTER to enter* the settings menu.
The menu starts where you last exited.
2. Press NEXT to view next setting.
The menu loops so keep going if you skipped
the setting you want to change.
3. Press ENTER to select the setting.
4. Press NEXT to increase the setting value.
The setting values loop so keep going if you
skipped the value you want to save.
5. Press ENTER to save* the new value and exit.
*Hold ENTER to exit the menu without saving.
List of Settings
Start : Enable Wireless (if o)
Stop : Disable Wireless (if on)
Auto O : Set Auto O Timer
Units : Set Unit of Measure
Alarm Lo : Set Low Alarm Level
Alarm Hi : Set High Alarm Level
Mute : Enable Speaker (if o)
Unmute : Disable Speaker (if on)
BkLtTime : Set Backlight Timer
Firmware : View and Update Firmware
Restore : Restore Default Settings
Wireless
Start or stop sending wireless measurements.
Live measurements can be sent to SMAN
manifold (overrides its internal vacuum gauge),
and to the Job Link mobile app for added
capabilities such as live trending. Wireless is
disabled by default to maximize battery life.
Auto Power Off Timer (APO)
Set the timer for the gauge automatically
powering o. The timer is reset when a button
is pressed. The timer is disabled in alarm mode.
(15min, 30min, 45min, 60min, Disabled)
Units
Set the unit of vacuum measurement. Alarm
levels are automatically converted to match the
unit setting.
(Microns, Pascals, mBar, mTorr, Torr, mmHg)
Low Alarm Level ( )
Set the vacuum level required to trigger the
low alarm. Hold NEXT for quicker scrolling.
(50 - 500 - High Alarm)
High Alarm Level ( )
Set the vacuum level required to trigger the
high alarm. Hold NEXT for quicker scrolling.
(Low Alarm - 1000 - 9000)
Mute ( )
Mute or unmute the speaker. Button presses
and alarms remain silent if the speaker is muted.
The icon appears if the speaker is muted.
Backlight Timer
Set the timer for the backlight automatically
turning o. The timer is reset when a button is
pressed.
(10s,20s,1min,2min,5min,10min,15min,30min)
Firmware
Check the firmware version (X.XXX.X) by
reading the first 4 digits. If a new version is
available from the Job Link mobile app, initiate
the update from your mobile device.
Restore
To restore all settings to their factory defaults,
press NEXT until "YES" is displayed and press
ENTER to conrm. To exit without restoring,
select "no" or hold ENTER.
Evacuation Tips
MAXIMIZE FLOW
• Remove Schrader valve cores with a removal
tool.
• Remove valve depressors from hoses.
• Useshortestvacuumratedhoseswithlargest
diameter available.
• Do not evacuate through hoses with low loss
ttings.
TRUST YOUR TEST
• Inspect the rubber seals at both ends of your
hoses for damage. Replace as needed.
• Change pump oil before and during the job.
Change pump oil on-the-y without losing
vacuum with Fieldpiece vacuum pumps.
• When the vacuum pump is isolated from the
system, a slow rise that stabilizes may signify
moisture is still present in the system. A con-
tinuous rise to atmosphere indicates a leak.
Check hoses, tools, or the system itself.
• Measurements are less representative of the
entire system when the vacuum pump is on
because pumping creates a pressure gradi-
ent.Isolatethe pump and allowthe system to
stabilize before assuming the measurement
represents the entire system.
Certifications
and Module IDs
FCC Statement
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installedand used in accordance withthe instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the
interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit dierent from that
to which the receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or
modications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
(Example - use only shielded interface cables when connecting to
computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device complies with Industry Canada licence-exempt RSS-247
standard. Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interferencethat may cause undesired operation
of the device.
IC Radiation Exposure Statement: This equipment complies
with IC RSS-102 radiation exposure limit set forth for an uncontrolled
environment. This equipment should be installed and operated with
minimum distance 0.5 cm between the radiator and your body.
Fieldpiece Instruments 1636 West Collins Avenue, Orange, CA 92867
IFETEL Statement
Laoperacióndeesteequipoestásujetaalassiguientesdoscondiciones:
(1) es posible que este equipo o dispositivo no cause interferencia
perjudicial y (2) este equipo o dispositivo debe aceptar cualquier
interferencia, incluyendo la que pueda causar su operación no deseada.
The operation of this equipment is subject to the following two
conditions: (1)this device or device may not cause harmful interference,
and (2) this device or device must accept any interference, including
interference that may cause undesired operation.
ANATEL Statement
Este equipamento não tem direito à proteção contra interferência
prejudicial e não pode causar interferência em sistemas devidamente
autorizados.
This equipment is not subject to the protection from harmful
interference and may not cause interference with duly authorized
systems.
Limited Warranty
This product is warranted against defects in material and
workmanship for one year from date of purchase from an authorized
Fieldpiece dealer. Fieldpiece will replace or repair the defective unit,
at its option, subject to verication of the defect.
This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arisingfrom thesale of a Fieldpiece product,
including but not limited to implied warranties of merchantability and
tness for a particular purpose, are limited to the above. Fieldpiece
shall not be liable for loss of use of the instrument or other incidental
or consequential damages, expenses, or economic loss, or for any claim
of such damage, expenses, or economic loss.
State laws vary. The above limitations or exclusions may not apply
to you.
Obtaining Service
For international customers, warranty for products purchased
outside of the U.S. should be handled through local distributors. Visit
our website to nd your local distributor.
© Fieldpiece Instruments, Inc 2021; v01
EN 300 328
2ALHR003
00263-18-10972
IC: Industry Canada
22518-BT003
IFETEL: Federal Telecom Institute
RCPFI2A18-0235
Regulatory Compliance Mark
Waste Electrical and
Electronic Equipment
Restriction of Hazardous
Substances Compliant

11
16
12
17
13
18
14
19
15
20
Settings Menu
The settings menu can be entered when
in standard operating mode. Selecting a new
setting automatically exits the menu.This saves
time getting in and out of the menu quickly
for your most commonly changed setting (e.g.
wireless).
1. Hold ENTER to enter* the settings menu.
The menu starts where you last exited.
2. Press NEXT to view next setting.
The menu loops so keep going if you skipped
the setting you want to change.
3. Press ENTER to select the setting.
4. Press NEXT to increase the setting value.
The setting values loop so keep going if you
skipped the value you want to save.
5. Press ENTER to save* the new value and exit.
*Hold ENTER to exit the menu without saving.
List of Settings
Start : Enable Wireless (if o)
Stop : Disable Wireless (if on)
Auto O : Set Auto O Timer
Units : Set Unit of Measure
Alarm Lo : Set Low Alarm Level
Alarm Hi : Set High Alarm Level
Mute : Enable Speaker (if o)
Unmute : Disable Speaker (if on)
BkLtTime : Set Backlight Timer
Firmware : View and Update Firmware
Restore : Restore Default Settings
Wireless
Start or stop sending wireless measurements.
Live measurements can be sent to SMAN
manifold (overrides its internal vacuum gauge),
and to the Job Link mobile app for added
capabilities such as live trending. Wireless is
disabled by default to maximize battery life.
Auto Power Off Timer (APO)
Set the timer for the gauge automatically
powering o. The timer is reset when a button
is pressed. The timer is disabled in alarm mode.
(15min, 30min, 45min, 60min, Disabled)
Units
Set the unit of vacuum measurement. Alarm
levels are automatically converted to match the
unit setting.
(Microns, Pascals, mBar, mTorr, Torr, mmHg)
Low Alarm Level ( )
Set the vacuum level required to trigger the
low alarm. Hold NEXT for quicker scrolling.
(50 - 500 - High Alarm)
High Alarm Level ( )
Set the vacuum level required to trigger the
high alarm. Hold NEXT for quicker scrolling.
(Low Alarm - 1000 - 9000)
Mute ( )
Mute or unmute the speaker. Button presses
and alarms remain silent if the speaker is muted.
The icon appears if the speaker is muted.
Backlight Timer
Set the timer for the backlight automatically
turning o. The timer is reset when a button is
pressed.
(10s,20s,1min,2min,5min,10min,15min,30min)
Firmware
Check the firmware version (X.XXX.X) by
reading the first 4 digits. If a new version is
available from the Job Link mobile app, initiate
the update from your mobile device.
Restore
To restore all settings to their factory defaults,
press NEXT until "YES" is displayed and press
ENTER to conrm. To exit without restoring,
select "no" or hold ENTER.
Evacuation Tips
MAXIMIZE FLOW
• Remove Schrader valve cores with a removal
tool.
• Remove valve depressors from hoses.
• Useshortestvacuumratedhoseswithlargest
diameter available.
• Do not evacuate through hoses with low loss
ttings.
TRUST YOUR TEST
• Inspect the rubber seals at both ends of your
hoses for damage. Replace as needed.
• Change pump oil before and during the job.
Change pump oil on-the-y without losing
vacuum with Fieldpiece vacuum pumps.
• When the vacuum pump is isolated from the
system, a slow rise that stabilizes may signify
moisture is still present in the system. A con-
tinuous rise to atmosphere indicates a leak.
Check hoses, tools, or the system itself.
• Measurements are less representative of the
entire system when the vacuum pump is on
because pumping creates a pressure gradi-
ent.Isolatethe pumpandallowthe systemto
stabilize before assuming the measurement
represents the entire system.
Certifications
and Module IDs
FCC Statement
This equipment hasbeen tested and foundto comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and,if not installedand used in accordance withthe instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the
interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit dierent from that
to which the receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or
modications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
(Example - use only shielded interface cables when connecting to
computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device complies with Industry Canada licence-exempt RSS-247
standard. Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference,including interference that may cause undesired operation
of the device.
IC Radiation Exposure Statement: This equipment complies
with IC RSS-102 radiation exposure limit set forth for an uncontrolled
environment. This equipment should be installed and operated with
minimum distance 0.5 cm between the radiator and your body.
Fieldpiece Instruments 1636 West Collins Avenue, Orange, CA 92867
IFETEL Statement
Laoperacióndeesteequipoestásujetaalassiguientesdoscondiciones:
(1) es posible que este equipo o dispositivo no cause interferencia
perjudicial y (2) este equipo o dispositivo debe aceptar cualquier
interferencia, incluyendo la que pueda causar su operación no deseada.
The operation of this equipment is subject to the following two
conditions: (1)this device ordevice may not cause harmful interference,
and (2) this device or device must accept any interference, including
interference that may cause undesired operation.
ANATEL Statement
Este equipamento não tem direito à proteção contra interferência
prejudicial e não pode causar interferência em sistemas devidamente
autorizados.
This equipment is not subject to the protection from harmful
interference and may not cause interference with duly authorized
systems.
Limited Warranty
This product is warranted against defects in material and
workmanship for one year from date of purchase from an authorized
Fieldpiece dealer. Fieldpiece will replace or repair the defective unit,
at its option, subject to verication of the defect.
This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arisingfrom thesale of a Fieldpieceproduct,
including but not limited to implied warranties of merchantability and
tness for a particular purpose, are limited to the above. Fieldpiece
shall not be liable for loss of use of the instrument or other incidental
or consequential damages, expenses, or economic loss, or for any claim
of such damage, expenses, or economic loss.
State laws vary. The above limitations or exclusions may not apply
to you.
Obtaining Service
For international customers, warranty for products purchased
outside of the U.S. should be handled through local distributors. Visit
our website to nd your local distributor.
© Fieldpiece Instruments, Inc 2021; v01
EN 300 328
2ALHR003
00263-18-10972
IC: Industry Canada
22518-BT003
IFETEL: Federal Telecom Institute
RCPFI2A18-0235
Regulatory Compliance Mark
Waste Electrical and
Electronic Equipment
Restriction of Hazardous
Substances Compliant

11
16
12
17
13
18
14
19
15
20
Settings Menu
The settings menu can be entered when
in standard operating mode. Selecting a new
setting automatically exits the menu.This saves
time getting in and out of the menu quickly
for your most commonly changed setting (e.g.
wireless).
1. Hold ENTER to enter* the settings menu.
The menu starts where you last exited.
2. Press NEXT to view next setting.
The menu loops so keep going if you skipped
the setting you want to change.
3. Press ENTER to select the setting.
4. Press NEXT to increase the setting value.
The setting values loop so keep going if you
skipped the value you want to save.
5. Press ENTER to save* the new value and exit.
*Hold ENTER to exit the menu without saving.
List of Settings
Start : Enable Wireless (if o)
Stop : Disable Wireless (if on)
Auto O : Set Auto O Timer
Units : Set Unit of Measure
Alarm Lo : Set Low Alarm Level
Alarm Hi : Set High Alarm Level
Mute : Enable Speaker (if o)
Unmute : Disable Speaker (if on)
BkLtTime : Set Backlight Timer
Firmware : View and Update Firmware
Restore : Restore Default Settings
Wireless
Start or stop sending wireless measurements.
Live measurements can be sent to SMAN
manifold (overrides its internal vacuum gauge),
and to the Job Link mobile app for added
capabilities such as live trending. Wireless is
disabled by default to maximize battery life.
Auto Power Off Timer (APO)
Set the timer for the gauge automatically
powering o. The timer is reset when a button
is pressed. The timer is disabled in alarm mode.
(15min, 30min, 45min, 60min, Disabled)
Units
Set the unit of vacuum measurement. Alarm
levels are automatically converted to match the
unit setting.
(Microns, Pascals, mBar, mTorr, Torr, mmHg)
Low Alarm Level ( )
Set the vacuum level required to trigger the
low alarm. Hold NEXT for quicker scrolling.
(50 - 500 - High Alarm)
High Alarm Level ( )
Set the vacuum level required to trigger the
high alarm. Hold NEXT for quicker scrolling.
(Low Alarm - 1000 - 9000)
Mute ( )
Mute or unmute the speaker. Button presses
and alarms remain silent if the speaker is muted.
The icon appears if the speaker is muted.
Backlight Timer
Set the timer for the backlight automatically
turning o. The timer is reset when a button is
pressed.
(10s,20s,1min,2min,5min,10min,15min,30min)
Firmware
Check the firmware version (X.XXX.X) by
reading the first 4 digits. If a new version is
available from the Job Link mobile app, initiate
the update from your mobile device.
Restore
To restore all settings to their factory defaults,
press NEXT until "YES" is displayed and press
ENTER to conrm. To exit without restoring,
select "no" or hold ENTER.
Evacuation Tips
MAXIMIZE FLOW
• Remove Schrader valve cores with a removal
tool.
• Remove valve depressors from hoses.
• Useshortestvacuumratedhoseswithlargest
diameter available.
• Do not evacuate through hoses with low loss
ttings.
TRUST YOUR TEST
• Inspect the rubber seals at both ends of your
hoses for damage. Replace as needed.
• Change pump oil before and during the job.
Change pump oil on-the-y without losing
vacuum with Fieldpiece vacuum pumps.
• When the vacuum pump is isolated from the
system, a slow rise that stabilizes may signify
moisture is still present in the system. A con-
tinuous rise to atmosphere indicates a leak.
Check hoses, tools, or the system itself.
• Measurements are less representative of the
entire system when the vacuum pump is on
because pumping creates a pressure gradi-
ent.Isolatethe pump andallow thesystemto
stabilize before assuming the measurement
represents the entire system.
Certifications
and Module IDs
FCC Statement
This equipment hasbeen tested and foundto comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installedand used in accordance withthe instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the
interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit dierent from that
to which the receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or
modications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
(Example - use only shielded interface cables when connecting to
computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device complies with Industry Canada licence-exempt RSS-247
standard. Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference,including interference that may cause undesired operation
of the device.
IC Radiation Exposure Statement: This equipment complies
with IC RSS-102 radiation exposure limit set forth for an uncontrolled
environment. This equipment should be installed and operated with
minimum distance 0.5 cm between the radiator and your body.
Fieldpiece Instruments 1636 West Collins Avenue, Orange, CA 92867
IFETEL Statement
Laoperacióndeesteequipoestásujetaalassiguientesdoscondiciones:
(1) es posible que este equipo o dispositivo no cause interferencia
perjudicial y (2) este equipo o dispositivo debe aceptar cualquier
interferencia, incluyendo la que pueda causar su operación no deseada.
The operation of this equipment is subject to the following two
conditions: (1)this device ordevice maynot cause harmful interference,
and (2) this device or device must accept any interference, including
interference that may cause undesired operation.
ANATEL Statement
Este equipamento não tem direito à proteção contra interferência
prejudicial e não pode causar interferência em sistemas devidamente
autorizados.
This equipment is not subject to the protection from harmful
interference and may not cause interference with duly authorized
systems.
Limited Warranty
This product is warranted against defects in material and
workmanship for one year from date of purchase from an authorized
Fieldpiece dealer. Fieldpiece will replace or repair the defective unit,
at its option, subject to verication of the defect.
This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arisingfrom thesale of a Fieldpieceproduct,
including but not limited to implied warranties of merchantability and
tness for a particular purpose, are limited to the above. Fieldpiece
shall not be liable for loss of use of the instrument or other incidental
or consequential damages, expenses, or economic loss, or for any claim
of such damage, expenses, or economic loss.
State laws vary. The above limitations or exclusions may not apply
to you.
Obtaining Service
For international customers, warranty for products purchased
outside of the U.S. should be handled through local distributors. Visit
our website to nd your local distributor.
© Fieldpiece Instruments, Inc 2021; v01
EN 300 328
2ALHR003
00263-18-10972
IC: Industry Canada
22518-BT003
IFETEL: Federal Telecom Institute
RCPFI2A18-0235
Regulatory Compliance Mark
Waste Electrical and
Electronic Equipment
Restriction of Hazardous
Substances Compliant

11
16
12
17
13
18
14
19
15
20
Settings Menu
The settings menu can be entered when
in standard operating mode. Selecting a new
setting automatically exits the menu.This saves
time getting in and out of the menu quickly
for your most commonly changed setting (e.g.
wireless).
1. Hold ENTER to enter* the settings menu.
The menu starts where you last exited.
2. Press NEXT to view next setting.
The menu loops so keep going if you skipped
the setting you want to change.
3. Press ENTER to select the setting.
4. Press NEXT to increase the setting value.
The setting values loop so keep going if you
skipped the value you want to save.
5. Press ENTER to save* the new value and exit.
*Hold ENTER to exit the menu without saving.
List of Settings
Start : Enable Wireless (if o)
Stop : Disable Wireless (if on)
Auto O : Set Auto O Timer
Units : Set Unit of Measure
Alarm Lo : Set Low Alarm Level
Alarm Hi : Set High Alarm Level
Mute : Enable Speaker (if o)
Unmute : Disable Speaker (if on)
BkLtTime : Set Backlight Timer
Firmware : View and Update Firmware
Restore : Restore Default Settings
Wireless
Start or stop sending wireless measurements.
Live measurements can be sent to SMAN
manifold (overrides its internal vacuum gauge),
and to the Job Link mobile app for added
capabilities such as live trending. Wireless is
disabled by default to maximize battery life.
Auto Power Off Timer (APO)
Set the timer for the gauge automatically
powering o. The timer is reset when a button
is pressed. The timer is disabled in alarm mode.
(15min, 30min, 45min, 60min, Disabled)
Units
Set the unit of vacuum measurement. Alarm
levels are automatically converted to match the
unit setting.
(Microns, Pascals, mBar, mTorr, Torr, mmHg)
Low Alarm Level ( )
Set the vacuum level required to trigger the
low alarm. Hold NEXT for quicker scrolling.
(50 - 500 - High Alarm)
High Alarm Level ( )
Set the vacuum level required to trigger the
high alarm. Hold NEXT for quicker scrolling.
(Low Alarm - 1000 - 9000)
Mute ( )
Mute or unmute the speaker. Button presses
and alarms remain silent if the speaker is muted.
The icon appears if the speaker is muted.
Backlight Timer
Set the timer for the backlight automatically
turning o. The timer is reset when a button is
pressed.
(10s,20s,1min,2min,5min,10min,15min,30min)
Firmware
Check the firmware version (X.XXX.X) by
reading the first 4 digits. If a new version is
available from the Job Link mobile app, initiate
the update from your mobile device.
Restore
To restore all settings to their factory defaults,
press NEXT until "YES" is displayed and press
ENTER to conrm. To exit without restoring,
select "no" or hold ENTER.
Evacuation Tips
MAXIMIZE FLOW
• Remove Schrader valve cores with a removal
tool.
• Remove valve depressors from hoses.
• Useshortestvacuumratedhoseswithlargest
diameter available.
• Do not evacuate through hoses with low loss
ttings.
TRUST YOUR TEST
• Inspect the rubber seals at both ends of your
hoses for damage. Replace as needed.
• Change pump oil before and during the job.
Change pump oil on-the-y without losing
vacuum with Fieldpiece vacuum pumps.
• When the vacuum pump is isolated from the
system, a slow rise that stabilizes may signify
moisture is still present in the system. A con-
tinuous rise to atmosphere indicates a leak.
Check hoses, tools, or the system itself.
• Measurements are less representative of the
entire system when the vacuum pump is on
because pumping creates a pressure gradi-
ent.Isolate the pump andallowthesystemto
stabilize before assuming the measurement
represents the entire system.
Certifications
and Module IDs
FCC Statement
This equipmenthas beentested andfoundto comply withthe limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if notinstalled andusedin accordance withthe instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the
interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit dierent from that
to which the receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or
modications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
(Example - use only shielded interface cables when connecting to
computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device complies with Industry Canada licence-exempt RSS-247
standard. Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference thatmay cause undesired operation
of the device.
IC Radiation Exposure Statement: This equipment complies
with IC RSS-102 radiation exposure limit set forth for an uncontrolled
environment. This equipment should be installed and operated with
minimum distance 0.5 cm between the radiator and your body.
Fieldpiece Instruments 1636 West Collins Avenue, Orange, CA 92867
IFETEL Statement
Laoperacióndeesteequipoestásujetaalassiguientesdoscondiciones:
(1) es posible que este equipo o dispositivo no cause interferencia
perjudicial y (2) este equipo o dispositivo debe aceptar cualquier
interferencia, incluyendo la que pueda causar su operación no deseada.
The operation of this equipment is subject to the following two
conditions: (1)this device or device maynot cause harmfulinterference,
and (2) this device or device must accept any interference, including
interference that may cause undesired operation.
ANATEL Statement
Este equipamento não tem direito à proteção contra interferência
prejudicial e não pode causar interferência em sistemas devidamente
autorizados.
This equipment is not subject to the protection from harmful
interference and may not cause interference with duly authorized
systems.
Limited Warranty
This product is warranted against defects in material and
workmanship for one year from date of purchase from an authorized
Fieldpiece dealer. Fieldpiece will replace or repair the defective unit,
at its option, subject to verication of the defect.
This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arisingfrom thesale ofa Fieldpieceproduct,
including but not limited to implied warranties of merchantability and
tness for a particular purpose, are limited to the above. Fieldpiece
shall not be liable for loss of use of the instrument or other incidental
or consequential damages, expenses, or economic loss, or for any claim
of such damage, expenses, or economic loss.
State laws vary. The above limitations or exclusions may not apply
to you.
Obtaining Service
For international customers, warranty for products purchased
outside of the U.S. should be handled through local distributors. Visit
our website to nd your local distributor.
© Fieldpiece Instruments, Inc 2021; v01
EN 300 328
2ALHR003
00263-18-10972
IC: Industry Canada
22518-BT003
IFETEL: Federal Telecom Institute
RCPFI2A18-0235
Regulatory Compliance Mark
Waste Electrical and
Electronic Equipment
Restriction of Hazardous
Substances Compliant

11
16
12
17
13
18
14
19
15
20
Settings Menu
The settings menu can be entered when
in standard operating mode. Selecting a new
setting automatically exits the menu.This saves
time getting in and out of the menu quickly
for your most commonly changed setting (e.g.
wireless).
1. Hold ENTER to enter* the settings menu.
The menu starts where you last exited.
2. Press NEXT to view next setting.
The menu loops so keep going if you skipped
the setting you want to change.
3. Press ENTER to select the setting.
4. Press NEXT to increase the setting value.
The setting values loop so keep going if you
skipped the value you want to save.
5. Press ENTER to save* the new value and exit.
*Hold ENTER to exit the menu without saving.
List of Settings
Start : Enable Wireless (if o)
Stop : Disable Wireless (if on)
Auto O : Set Auto O Timer
Units : Set Unit of Measure
Alarm Lo : Set Low Alarm Level
Alarm Hi : Set High Alarm Level
Mute : Enable Speaker (if o)
Unmute : Disable Speaker (if on)
BkLtTime : Set Backlight Timer
Firmware : View and Update Firmware
Restore : Restore Default Settings
Wireless
Start or stop sending wireless measurements.
Live measurements can be sent to SMAN
manifold (overrides its internal vacuum gauge),
and to the Job Link mobile app for added
capabilities such as live trending. Wireless is
disabled by default to maximize battery life.
Auto Power Off Timer (APO)
Set the timer for the gauge automatically
powering o. The timer is reset when a button
is pressed. The timer is disabled in alarm mode.
(15min, 30min, 45min, 60min, Disabled)
Units
Set the unit of vacuum measurement. Alarm
levels are automatically converted to match the
unit setting.
(Microns, Pascals, mBar, mTorr, Torr, mmHg)
Low Alarm Level ( )
Set the vacuum level required to trigger the
low alarm. Hold NEXT for quicker scrolling.
(50 - 500 - High Alarm)
High Alarm Level ( )
Set the vacuum level required to trigger the
high alarm. Hold NEXT for quicker scrolling.
(Low Alarm - 1000 - 9000)
Mute ( )
Mute or unmute the speaker. Button presses
and alarms remain silent if the speaker is muted.
The icon appears if the speaker is muted.
Backlight Timer
Set the timer for the backlight automatically
turning o. The timer is reset when a button is
pressed.
(10s,20s,1min,2min,5min,10min,15min,30min)
Firmware
Check the firmware version (X.XXX.X) by
reading the first 4 digits. If a new version is
available from the Job Link mobile app, initiate
the update from your mobile device.
Restore
To restore all settings to their factory defaults,
press NEXT until "YES" is displayed and press
ENTER to conrm. To exit without restoring,
select "no" or hold ENTER.
Evacuation Tips
MAXIMIZE FLOW
• Remove Schrader valve cores with a removal
tool.
• Remove valve depressors from hoses.
• Useshortestvacuumratedhoseswithlargest
diameter available.
• Do not evacuate through hoses with low loss
ttings.
TRUST YOUR TEST
• Inspect the rubber seals at both ends of your
hoses for damage. Replace as needed.
• Change pump oil before and during the job.
Change pump oil on-the-y without losing
vacuum with Fieldpiece vacuum pumps.
• When the vacuum pump is isolated from the
system, a slow rise that stabilizes may signify
moisture is still present in the system. A con-
tinuous rise to atmosphere indicates a leak.
Check hoses, tools, or the system itself.
• Measurements are less representative of the
entire system when the vacuum pump is on
because pumping creates a pressure gradi-
ent.Isolatethepump and allowthesystemto
stabilize before assuming the measurement
represents the entire system.
Certifications
and Module IDs
FCC Statement
This equipmenthas beentested and found to comply withthe limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if notinstalled andused in accordance with theinstructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the
interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit dierent from that
to which the receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or
modications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
(Example - use only shielded interface cables when connecting to
computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device complies with Industry Canada licence-exempt RSS-247
standard. Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference thatmay cause undesired operation
of the device.
IC Radiation Exposure Statement: This equipment complies
with IC RSS-102 radiation exposure limit set forth for an uncontrolled
environment. This equipment should be installed and operated with
minimum distance 0.5 cm between the radiator and your body.
Fieldpiece Instruments 1636 West Collins Avenue, Orange, CA 92867
IFETEL Statement
Laoperacióndeesteequipoestásujetaalassiguientesdoscondiciones:
(1) es posible que este equipo o dispositivo no cause interferencia
perjudicial y (2) este equipo o dispositivo debe aceptar cualquier
interferencia, incluyendo la que pueda causar su operación no deseada.
The operation of this equipment is subject to the following two
conditions: (1)this device or device maynot cause harmful interference,
and (2) this device or device must accept any interference, including
interference that may cause undesired operation.
ANATEL Statement
Este equipamento não tem direito à proteção contra interferência
prejudicial e não pode causar interferência em sistemas devidamente
autorizados.
This equipment is not subject to the protection from harmful
interference and may not cause interference with duly authorized
systems.
Limited Warranty
This product is warranted against defects in material and
workmanship for one year from date of purchase from an authorized
Fieldpiece dealer. Fieldpiece will replace or repair the defective unit,
at its option, subject to verication of the defect.
This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arisingfrom thesale of a Fieldpiece product,
including but not limited to implied warranties of merchantability and
tness for a particular purpose, are limited to the above. Fieldpiece
shall not be liable for loss of use of the instrument or other incidental
or consequential damages, expenses, or economic loss, or for any claim
of such damage, expenses, or economic loss.
State laws vary. The above limitations or exclusions may not apply
to you.
Obtaining Service
For international customers, warranty for products purchased
outside of the U.S. should be handled through local distributors. Visit
our website to nd your local distributor.
© Fieldpiece Instruments, Inc 2021; v01
EN 300 328
2ALHR003
00263-18-10972
IC: Industry Canada
22518-BT003
IFETEL: Federal Telecom Institute
RCPFI2A18-0235
Regulatory Compliance Mark
Waste Electrical and
Electronic Equipment
Restriction of Hazardous
Substances Compliant

11
16
12
17
13
18
14
19
15
20
Settings Menu
The settings menu can be entered when
in standard operating mode. Selecting a new
setting automatically exits the menu.This saves
time getting in and out of the menu quickly
for your most commonly changed setting (e.g.
wireless).
1. Hold ENTER to enter* the settings menu.
The menu starts where you last exited.
2. Press NEXT to view next setting.
The menu loops so keep going if you skipped
the setting you want to change.
3. Press ENTER to select the setting.
4. Press NEXT to increase the setting value.
The setting values loop so keep going if you
skipped the value you want to save.
5. Press ENTER to save* the new value and exit.
*Hold ENTER to exit the menu without saving.
List of Settings
Start : Enable Wireless (if o)
Stop : Disable Wireless (if on)
Auto O : Set Auto O Timer
Units : Set Unit of Measure
Alarm Lo : Set Low Alarm Level
Alarm Hi : Set High Alarm Level
Mute : Enable Speaker (if o)
Unmute : Disable Speaker (if on)
BkLtTime : Set Backlight Timer
Firmware : View and Update Firmware
Restore : Restore Default Settings
Wireless
Start or stop sending wireless measurements.
Live measurements can be sent to SMAN
manifold (overrides its internal vacuum gauge),
and to the Job Link mobile app for added
capabilities such as live trending. Wireless is
disabled by default to maximize battery life.
Auto Power Off Timer (APO)
Set the timer for the gauge automatically
powering o. The timer is reset when a button
is pressed. The timer is disabled in alarm mode.
(15min, 30min, 45min, 60min, Disabled)
Units
Set the unit of vacuum measurement. Alarm
levels are automatically converted to match the
unit setting.
(Microns, Pascals, mBar, mTorr, Torr, mmHg)
Low Alarm Level ( )
Set the vacuum level required to trigger the
low alarm. Hold NEXT for quicker scrolling.
(50 - 500 - High Alarm)
High Alarm Level ( )
Set the vacuum level required to trigger the
high alarm. Hold NEXT for quicker scrolling.
(Low Alarm - 1000 - 9000)
Mute ( )
Mute or unmute the speaker. Button presses
and alarms remain silent if the speaker is muted.
The icon appears if the speaker is muted.
Backlight Timer
Set the timer for the backlight automatically
turning o. The timer is reset when a button is
pressed.
(10s,20s,1min,2min,5min,10min,15min,30min)
Firmware
Check the firmware version (X.XXX.X) by
reading the first 4 digits. If a new version is
available from the Job Link mobile app, initiate
the update from your mobile device.
Restore
To restore all settings to their factory defaults,
press NEXT until "YES" is displayed and press
ENTER to conrm. To exit without restoring,
select "no" or hold ENTER.
Evacuation Tips
MAXIMIZE FLOW
• Remove Schrader valve cores with a removal
tool.
• Remove valve depressors from hoses.
• Useshortestvacuumratedhoseswithlargest
diameter available.
• Do not evacuate through hoses with low loss
ttings.
TRUST YOUR TEST
• Inspect the rubber seals at both ends of your
hoses for damage. Replace as needed.
• Change pump oil before and during the job.
Change pump oil on-the-y without losing
vacuum with Fieldpiece vacuum pumps.
• When the vacuum pump is isolated from the
system, a slow rise that stabilizes may signify
moisture is still present in the system. A con-
tinuous rise to atmosphere indicates a leak.
Check hoses, tools, or the system itself.
• Measurements are less representative of the
entire system when the vacuum pump is on
because pumping creates a pressure gradi-
ent.Isolatethe pump and allowthe system to
stabilize before assuming the measurement
represents the entire system.
Certifications
and Module IDs
FCC Statement
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installedand used in accordance withthe instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the
interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit dierent from that
to which the receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or
modications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
(Example - use only shielded interface cables when connecting to
computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device complies with Industry Canada licence-exempt RSS-247
standard. Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interferencethat may cause undesired operation
of the device.
IC Radiation Exposure Statement: This equipment complies
with IC RSS-102 radiation exposure limit set forth for an uncontrolled
environment. This equipment should be installed and operated with
minimum distance 0.5 cm between the radiator and your body.
Fieldpiece Instruments 1636 West Collins Avenue, Orange, CA 92867
IFETEL Statement
Laoperacióndeesteequipoestásujetaalassiguientesdoscondiciones:
(1) es posible que este equipo o dispositivo no cause interferencia
perjudicial y (2) este equipo o dispositivo debe aceptar cualquier
interferencia, incluyendo la que pueda causar su operación no deseada.
The operation of this equipment is subject to the following two
conditions: (1)this device or device may not cause harmful interference,
and (2) this device or device must accept any interference, including
interference that may cause undesired operation.
ANATEL Statement
Este equipamento não tem direito à proteção contra interferência
prejudicial e não pode causar interferência em sistemas devidamente
autorizados.
This equipment is not subject to the protection from harmful
interference and may not cause interference with duly authorized
systems.
Limited Warranty
This product is warranted against defects in material and
workmanship for one year from date of purchase from an authorized
Fieldpiece dealer. Fieldpiece will replace or repair the defective unit,
at its option, subject to verication of the defect.
This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arisingfrom thesale of a Fieldpiece product,
including but not limited to implied warranties of merchantability and
tness for a particular purpose, are limited to the above. Fieldpiece
shall not be liable for loss of use of the instrument or other incidental
or consequential damages, expenses, or economic loss, or for any claim
of such damage, expenses, or economic loss.
State laws vary. The above limitations or exclusions may not apply
to you.
Obtaining Service
For international customers, warranty for products purchased
outside of the U.S. should be handled through local distributors. Visit
our website to nd your local distributor.
© Fieldpiece Instruments, Inc 2021; v01
EN 300 328
2ALHR003
00263-18-10972
IC: Industry Canada
22518-BT003
IFETEL: Federal Telecom Institute
RCPFI2A18-0235
Regulatory Compliance Mark
Waste Electrical and
Electronic Equipment
Restriction of Hazardous
Substances Compliant

11
16
12
17
13
18
14
19
15
20
Settings Menu
The settings menu can be entered when
in standard operating mode. Selecting a new
setting automatically exits the menu.This saves
time getting in and out of the menu quickly
for your most commonly changed setting (e.g.
wireless).
1. Hold ENTER to enter* the settings menu.
The menu starts where you last exited.
2. Press NEXT to view next setting.
The menu loops so keep going if you skipped
the setting you want to change.
3. Press ENTER to select the setting.
4. Press NEXT to increase the setting value.
The setting values loop so keep going if you
skipped the value you want to save.
5. Press ENTER to save* the new value and exit.
*Hold ENTER to exit the menu without saving.
List of Settings
Start : Enable Wireless (if o)
Stop : Disable Wireless (if on)
Auto O : Set Auto O Timer
Units : Set Unit of Measure
Alarm Lo : Set Low Alarm Level
Alarm Hi : Set High Alarm Level
Mute : Enable Speaker (if o)
Unmute : Disable Speaker (if on)
BkLtTime : Set Backlight Timer
Firmware : View and Update Firmware
Restore : Restore Default Settings
Wireless
Start or stop sending wireless measurements.
Live measurements can be sent to SMAN
manifold (overrides its internal vacuum gauge),
and to the Job Link mobile app for added
capabilities such as live trending. Wireless is
disabled by default to maximize battery life.
Auto Power Off Timer (APO)
Set the timer for the gauge automatically
powering o. The timer is reset when a button
is pressed. The timer is disabled in alarm mode.
(15min, 30min, 45min, 60min, Disabled)
Units
Set the unit of vacuum measurement. Alarm
levels are automatically converted to match the
unit setting.
(Microns, Pascals, mBar, mTorr, Torr, mmHg)
Low Alarm Level ( )
Set the vacuum level required to trigger the
low alarm. Hold NEXT for quicker scrolling.
(50 - 500 - High Alarm)
High Alarm Level ( )
Set the vacuum level required to trigger the
high alarm. Hold NEXT for quicker scrolling.
(Low Alarm - 1000 - 9000)
Mute ( )
Mute or unmute the speaker. Button presses
and alarms remain silent if the speaker is muted.
The icon appears if the speaker is muted.
Backlight Timer
Set the timer for the backlight automatically
turning o. The timer is reset when a button is
pressed.
(10s,20s,1min,2min,5min,10min,15min,30min)
Firmware
Check the firmware version (X.XXX.X) by
reading the first 4 digits. If a new version is
available from the Job Link mobile app, initiate
the update from your mobile device.
Restore
To restore all settings to their factory defaults,
press NEXT until "YES" is displayed and press
ENTER to conrm. To exit without restoring,
select "no" or hold ENTER.
Evacuation Tips
MAXIMIZE FLOW
• Remove Schrader valve cores with a removal
tool.
• Remove valve depressors from hoses.
• Useshortest vacuum ratedhoseswithlargest
diameter available.
• Do not evacuate through hoses with low loss
ttings.
TRUST YOUR TEST
• Inspect the rubber seals at both ends of your
hoses for damage. Replace as needed.
• Change pump oil before and during the job.
Change pump oil on-the-y without losing
vacuum with Fieldpiece vacuum pumps.
• When the vacuum pump is isolated from the
system, a slow rise that stabilizes may signify
moisture is still present in the system. A con-
tinuous rise to atmosphere indicates a leak.
Check hoses, tools, or the system itself.
• Measurements are less representative of the
entire system when the vacuum pump is on
because pumping creates a pressure gradi-
ent.Isolatethe pumpand allowthesystem to
stabilize before assuming the measurement
represents the entire system.
Certifications
and Module IDs
FCC Statement
This equipment has been tested andfound to complywith the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and usedin accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the
interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit dierent from that
to which the receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or
modications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
(Example - use only shielded interface cables when connecting to
computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device complies with Industry Canada licence-exempt RSS-247
standard. Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference,including interference that may cause undesired operation
of the device.
IC Radiation Exposure Statement: This equipment complies
with IC RSS-102 radiation exposure limit set forth for an uncontrolled
environment. This equipment should be installed and operated with
minimum distance 0.5 cm between the radiator and your body.
Fieldpiece Instruments 1636 West Collins Avenue, Orange, CA 92867
IFETEL Statement
Laoperacióndeesteequipo estásujetaa lassiguientesdoscondiciones:
(1) es posible que este equipo o dispositivo no cause interferencia
perjudicial y (2) este equipo o dispositivo debe aceptar cualquier
interferencia, incluyendo la que pueda causar su operación no deseada.
The operation of this equipment is subject to the following two
conditions: (1) this device or device may not causeharmful interference,
and (2) this device or device must accept any interference, including
interference that may cause undesired operation.
ANATEL Statement
Este equipamento não tem direito à proteção contra interferência
prejudicial e não pode causar interferência em sistemas devidamente
autorizados.
This equipment is not subject to the protection from harmful
interference and may not cause interference with duly authorized
systems.
Limited Warranty
This product is warranted against defects in material and
workmanship for one year from date of purchase from an authorized
Fieldpiece dealer. Fieldpiece will replace or repair the defective unit,
at its option, subject to verication of the defect.
This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arising from the sale of a Fieldpiece product,
including but not limited to implied warranties of merchantability and
tness for a particular purpose, are limited to the above. Fieldpiece
shall not be liable for loss of use of the instrument or other incidental
or consequential damages, expenses, or economic loss, or for any claim
of such damage, expenses, or economic loss.
State laws vary.The above limitations or exclusions may not apply
to you.
Obtaining Service
For international customers, warranty for products purchased
outside of the U.S. should be handled through local distributors. Visit
our website to nd your local distributor.
© Fieldpiece Instruments, Inc 2021; v01
EN 300 328
2ALHR003
00263-18-10972
IC: Industry Canada
22518-BT003
IFETEL: Federal Telecom Institute
RCPFI2A18-0235
Regulatory Compliance Mark
Waste Electrical and
Electronic Equipment
Restriction of Hazardous
Substances Compliant

11
16
12
17
13
18
14
19
15
20
Settings Menu
The settings menu can be entered when
in standard operating mode. Selecting a new
setting automatically exits the menu.This saves
time getting in and out of the menu quickly
for your most commonly changed setting (e.g.
wireless).
1. Hold ENTER to enter* the settings menu.
The menu starts where you last exited.
2. Press NEXT to view next setting.
The menu loops so keep going if you skipped
the setting you want to change.
3. Press ENTER to select the setting.
4. Press NEXT to increase the setting value.
The setting values loop so keep going if you
skipped the value you want to save.
5. Press ENTER to save* the new value and exit.
*Hold ENTER to exit the menu without saving.
List of Settings
Start : Enable Wireless (if o)
Stop : Disable Wireless (if on)
Auto O : Set Auto O Timer
Units : Set Unit of Measure
Alarm Lo : Set Low Alarm Level
Alarm Hi : Set High Alarm Level
Mute : Enable Speaker (if o)
Unmute : Disable Speaker (if on)
BkLtTime : Set Backlight Timer
Firmware : View and Update Firmware
Restore : Restore Default Settings
Wireless
Start or stop sending wireless measurements.
Live measurements can be sent to SMAN
manifold (overrides its internal vacuum gauge),
and to the Job Link mobile app for added
capabilities such as live trending. Wireless is
disabled by default to maximize battery life.
Auto Power Off Timer (APO)
Set the timer for the gauge automatically
powering o. The timer is reset when a button
is pressed. The timer is disabled in alarm mode.
(15min, 30min, 45min, 60min, Disabled)
Units
Set the unit of vacuum measurement. Alarm
levels are automatically converted to match the
unit setting.
(Microns, Pascals, mBar, mTorr, Torr, mmHg)
Low Alarm Level ( )
Set the vacuum level required to trigger the
low alarm. Hold NEXT for quicker scrolling.
(50 - 500 - High Alarm)
High Alarm Level ( )
Set the vacuum level required to trigger the
high alarm. Hold NEXT for quicker scrolling.
(Low Alarm - 1000 - 9000)
Mute ( )
Mute or unmute the speaker. Button presses
and alarms remain silent if the speaker is muted.
The icon appears if the speaker is muted.
Backlight Timer
Set the timer for the backlight automatically
turning o. The timer is reset when a button is
pressed.
(10s,20s,1min,2min,5min,10min,15min,30min)
Firmware
Check the firmware version (X.XXX.X) by
reading the first 4 digits. If a new version is
available from the Job Link mobile app, initiate
the update from your mobile device.
Restore
To restore all settings to their factory defaults,
press NEXT until "YES" is displayed and press
ENTER to conrm. To exit without restoring,
select "no" or hold ENTER.
Evacuation Tips
MAXIMIZE FLOW
• Remove Schrader valve cores with a removal
tool.
• Remove valve depressors from hoses.
• Useshortestvacuumratedhoseswithlargest
diameter available.
• Do not evacuate through hoses with low loss
ttings.
TRUST YOUR TEST
• Inspect the rubber seals at both ends of your
hoses for damage. Replace as needed.
• Change pump oil before and during the job.
Change pump oil on-the-y without losing
vacuum with Fieldpiece vacuum pumps.
• When the vacuum pump is isolated from the
system, a slow rise that stabilizes may signify
moisture is still present in the system. A con-
tinuous rise to atmosphere indicates a leak.
Check hoses, tools, or the system itself.
• Measurements are less representative of the
entire system when the vacuum pump is on
because pumping creates a pressure gradi-
ent.Isolate the pump andallowthesystemto
stabilize before assuming the measurement
represents the entire system.
Certifications
and Module IDs
FCC Statement
This equipmenthas beentested andfoundto comply withthe limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if notinstalled andusedin accordance withthe instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the
interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit dierent from that
to which the receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or
modications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
(Example - use only shielded interface cables when connecting to
computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device complies with Industry Canada licence-exempt RSS-247
standard. Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference thatmay cause undesired operation
of the device.
IC Radiation Exposure Statement: This equipment complies
with IC RSS-102 radiation exposure limit set forth for an uncontrolled
environment. This equipment should be installed and operated with
minimum distance 0.5 cm between the radiator and your body.
Fieldpiece Instruments 1636 West Collins Avenue, Orange, CA 92867
IFETEL Statement
Laoperacióndeesteequipoestásujetaalassiguientesdoscondiciones:
(1) es posible que este equipo o dispositivo no cause interferencia
perjudicial y (2) este equipo o dispositivo debe aceptar cualquier
interferencia, incluyendo la que pueda causar su operación no deseada.
The operation of this equipment is subject to the following two
conditions: (1)this device or device maynot cause harmfulinterference,
and (2) this device or device must accept any interference, including
interference that may cause undesired operation.
ANATEL Statement
Este equipamento não tem direito à proteção contra interferência
prejudicial e não pode causar interferência em sistemas devidamente
autorizados.
This equipment is not subject to the protection from harmful
interference and may not cause interference with duly authorized
systems.
Limited Warranty
This product is warranted against defects in material and
workmanship for one year from date of purchase from an authorized
Fieldpiece dealer. Fieldpiece will replace or repair the defective unit,
at its option, subject to verication of the defect.
This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arisingfrom thesale ofa Fieldpieceproduct,
including but not limited to implied warranties of merchantability and
tness for a particular purpose, are limited to the above. Fieldpiece
shall not be liable for loss of use of the instrument or other incidental
or consequential damages, expenses, or economic loss, or for any claim
of such damage, expenses, or economic loss.
State laws vary. The above limitations or exclusions may not apply
to you.
Obtaining Service
For international customers, warranty for products purchased
outside of the U.S. should be handled through local distributors. Visit
our website to nd your local distributor.
© Fieldpiece Instruments, Inc 2021; v01
EN 300 328
2ALHR003
00263-18-10972
IC: Industry Canada
22518-BT003
IFETEL: Federal Telecom Institute
RCPFI2A18-0235
Regulatory Compliance Mark
Waste Electrical and
Electronic Equipment
Restriction of Hazardous
Substances Compliant
Table of contents
Popular Packaging Equipment manuals by other brands

Advanced Poly-Packaging
Advanced Poly-Packaging Advanced Poly-Bagger T-1000-S14 Operation manual

Titan
Titan PKD instruction manual

Sipromac
Sipromac 560A owner's manual

3TECH
3TECH TS-12 manual

Advanced Poly-Packaging
Advanced Poly-Packaging Advanced Poly-Bagger T-1000 Operation guide

Polychem
Polychem PWT Operation manual and spare parts list