L2 RECEIVER TYPE DEFAULT = 6
Enter the digit for the desired receiver type from the chart below in location L2.
VALUE DESCRIPTION TYPICAL CS RECEIVERS
o= 10 PPS, 1400 Hz., No Parity FBI, Ademco Slow, Silent Knight Slow
l= 10 PPS, 1400 Hz, Parity FBI
2= 10 PPS, 2300 Hz, No Parity FBI
3= 10 PPS, 2300 Hz, Parity FBI
4= 20 PPS, 1400 Hz, No Parity FBI, Silent Knight Fast, ADCOR, ADEMCO 685
5= 20 PPS, 1400 Hz, Parity FBI, Radionics Slow (1400)
6= 20 PPS, 2300Hz., No Parity FBI, Franklin, Sescoa, DCI, Quickalert, Varitech, ADEMCO 685
7= 20 PPS, 2300 Hz, Parity FBI, Radionics Slow (2300)
8= 40 PPS, 1400 Hz, No Parity FBI
A= 40 PPS, 2300 Hz, No Parity FBI
B= 40 PPS, 2300 Hz, Parity FBI, Radionics Fast (2300)
NOTE: For UL installations the acceptable receivers are FBI CP220 (all formats), ADEMCO 685 (all formats without
parity), Silent Knight 8520 or 9000.
L3 - MESSAGE LENGTH/BELL LOCKOUT Default = 1
r
Enter the digit for the desired message length from the chart below in location L3.
o= 3 x 1 3 digit account, 1dlglt event code, no bell lockout 8 = 3x1, with bell lockout
2
fjf
4x1 4 digit account number, 1digit event code, no bell lockout A = 4x1, with bell lockout
4 x 2 4 digit account number, 2 digit event code, no bell lockout E = 4x2, with bell lockout
If bell lockout is selected then subsequent activations of the same zone within the same arming interval will not activate
the bell. This applies only to burglary (non 24 hour) zones. For UL installations bell lockout must not be selected.
NOTE: Please consult your Central Station manager to determine the formats and message lengths which are accepted
by the receiver. To select European dialing format, add 1to the value selected for this digit.
L4- SYSTEM OPTIONS Default = 1
Enter the digit for the desired system options from the chart below in location L4.
o= Silent Keypad Panic
1 Audlble Keypad Panic r
2:
Silent Keypad Panic, Split Reporting
3
41 Audible Keypad Panic, Split Reporting
Silent Keypad Panic, 24 Hr Test
5= Audible Keypad Panic, 24 Hr Test
6= Silent Keypad Panic, Split Reporting, 24 Hr Test
7= Audible Keypad Panic, Split Reporting, 24 hr Test
8= Silent Keypad Panic, Bell Test
9= Audible Keypad Panic, Bell Test
A= Silent Keypad Panic, Split Reporting, Bell Test
B= Audible Keypad Panic, Split Reporting, Bell Test
c= Silent Keypad Panic, 24 Hr Test, Bell Test
D= Audible Keypad Panic, 24 hr Test, Bell Test
E= Silent Keypad Panic, Split Reporting, 24 Hr Test, Bell Test
F= Audible Keypad Panic, Split Reporting, 24 Hr Test, Bell Test
DESCRIPTION OF SYSTEM OPTIONS
Keypad SllentlAudlble Panic - Determines whether the keypad panic condition ( ’ & #from the keypad) will activate
the bell. In either case a signal will be transmitted to the Central Station if a panic code has been programmed. NOTE: The
keypad panic condition can be activated through location 1of question 05.
Split Reporting -The split reportingoptionwill direct allopeningandclosing signalstothe secondary receivertelephone
number. All otherconditions (alarms, troubles, restores etc.) will adhereto the reporting routedescribed inquestion 01.If split
reporting is selected then the secondary receiver telephone number MUST be programmed.
24 Hour Test - If 24 hourtest is enabled then the XL46OODLwill transmit the test code to the Central Station every 24
hours inthe absence of anyother signal. Transmission of any signalwill resetthe 24 hourtest clock. Forexample ifa businessr
opened and closed 6 days a week then a test signal will be generated 24 hours after the last closing signal. NOTE: This
option is requiredfor UL Commercial Burglary applications. ‘.
Bell Test If this option is selected the bell will be activated for one second upon successful arming. This option is
required for UL Commercial Burglary applications.
STAR XL4600DL HOOKUP & INSTALLATION Page 16