17
Programming Question Table
Q # QUESTION DEFAULT
Q-1 Select RF sensor # (01-48)
Q-1 SUB-QUESTIONS
Select RF sensor (#) type (00) unused
Select RF sensor (#) equipment type Varies by RF sensor type
(Only shown for some sensor types)
Select RF sensor (#) equipment code (0000) other
Enter RF sensor (#) other equipment code (0-9999) 0 (Only shown if other is selected)
Enter RF sensor (#) serial number (7 digits) 0000000
Select RF sensor (#) equipment age (0-1) (0) new
Select RF sensor (#) loop number (1-3) Varies with sensor model selected
Select RF sensor (#) dialer delay (0-1) ‡(1) enabled (except for fire & CO)
Construct RF sensor (#) voice descriptor No default
Select RF sensor (#) reports (0-1) (1) enabled
Select RF sensor (#) supervised (0-1) (1) enabled
Select RF sensor (#) chime (0-5) (0) disabled
Q-2 Select wired sensor # (1-2)
Q-2 SUB-QUESTIONS
Select wired sensor (#) type (00) unused
Select wired sensor (#) equipment type Varies by wired sensor type
(Only shown for some sensor types)
Enter wired sensor (#) equipment code (0-9999) 0
Select wired sensor (#) equipment age (0-1) (0) new
Select wired sensor (#) normal state (0) not used
Select wired sensor (#) dialer delay (0-1) ‡(1) enabled
Construct wired sensor (#) voice descriptor No default
Select wired sensor (#) reports (0-1) (1) enabled
Select wired sensor (#) chime (0-5) (0) disabled
Q-3Select fob # (1-8)
Q-3SUB-QUESTIONS
Select fob (#) used (0-1) (0) unused
Select fob (#) equipment code (0000) (0000) other
Enter fob (#) other equipment code (0-9999) 0 (Only shown if other is selected)
Enter fob (#) serial number (7 digits) 0000000
Select fob (#) equipment age (0-1) (0) new
Select fob (#) emergency key (0-4) (0) disabled
Select fob (#) key 2 can disarm (0-1) (1) enabled
Construct fob (#) voice descriptor keyfob #
Select fob (#) arm no delay (0-1) (0) disabled
Select fob (#) key 4 output (0-2) (0) disabled
Q-4 Select RF keypad # (1-4)
Q-4 SUB-QUESTIONS
Select RF keypad (#) used (0-1) (0) unused
Select RF keypad (#) equipment code (0000) other
Enter RF keypad (#) other equipment code (0-9999) 0 (Only shown if other is selected)
Enter RF keypad (#) serial number (7 digits) 0000000
Select RF keypad (#) equipment age (0-1) (0) new
Select RF keypad (#) emergency keys (0-1) (1) enabled
Construct RF keypad (#) voice descriptor keypad #
Q-5 Enter exit delay, in seconds (45-120) ‡60 seconds
Q-6 Enter entry delay 1, in seconds (30-240) ‡30 seconds
Q-7 Enter entry delay 2, in seconds (30-240) ‡45 seconds
Q-8Select dialer (0-1) (0) disabled
Q-9 Enter dialing prefix (0-4 digits) No default
Q-10 Enter call waiting disable code (0-6 digits) ‡No default
Q-11 Enter CS #1 phone number (0-25 digits) No default
Q-12 Enter CS #1 account number (4 digits) No default
Q-13Select 2-way voice (0-2) (1) stay on line
Q-14 Select silent panic/burglary listen only (0-1) (1) enabled
Q-15 Select dialing type (0-1) (0) touch tone
Q-16 Select police emergency key (0-2) (1) audible
Q-17 Select fire emergency key (0-1) (1) audible
Q-18Select emergency key (0-1) (1) audible
Q-19 Select quick arming (0-1) (1) enabled
Q-20 Select swinger shutdown count (1-6) ‡(2) two trips
Q-21 Select siren supervision time (0-3) (0) disabled
Q-22 Enter CS lack of usage notification time (0-255) 7 Days
Q-23Enter radio modem network failure time (0-255) 30 minutes
Q-24 Select radio modem network failure causes trouble (0-1) (1) enabled
Q-25 Select radio modem network failure reports (0-1) (1) enabled
Q-26 Select auto stay (0-1) ‡(1) enabled
Q-27 Select exit delay restart (0-1) ‡(1) enabled
Q # QUESTION DEFAULT
Q-28Select quick exit (0-1) (1) enabled
Q-29 Enter periodic test, in days (0-255) 30 days
Q-31Enter cancel time, in minutes (5-255) ‡5 minutes
Q-32Select cancel display (0-1) ‡(1) enabled
Q-33 Select cross sensor 47-48 (0-1) (0) disabled
Q-34Enter cross sensor timeout, in seconds (10-120) 10 seconds
Q-35Select abort window dialer delay (0-2) ‡(1) 30 seconds
Q-36Select burglary bell cutoff (0-4) (0) 4 minutes
Q-37Select fire bell cutoff (0-4) (0) 4 minutes
Q-38 Enter time to detect AC loss, in minutes (0-30) 10 minutes
Q-39Select random AC loss report time (0-1) (1) enabled
Q-40 Enter CS #2 phone number (0-25 digits) No default
Q-41 Enter CS #2 account number (4 digits) No default
Q-42 Select remote control phone (0-3) (3) data and voice
Q-43Enter installer code (4 digits) 1561
Q-44 Select lock installer programming (0-2) (0) disabled
Q-45 Select lock default programming (0-2) (0) default all
Q-46 Select trouble doesn’t sound at night (0-1) ♦(1) enabled
Q-47 Select trouble resound after holdoff (0-7) (0) disabled
Q-48Enter download csid (6 digits) 000000
Q-49 Select programming mode entry reports to CS (0-1) (0) disabled
Q-50 Select trouble reports to CS (0-1) (1) enabled
Q-51 Select manual bypass reports to CS (0-1) (0) disabled
Q-52 Select AC loss reports to CS (0-1) (1) enabled
Q-53Select system low battery reports to CS (0-1) (1) enabled
Q-54 Select RF low battery reports to CS (0-1) (1) enabled
Q-55 Select opening reports to CS (0-1) (0) disabled
Q-56 Select closing reports to CS (0-1) (0) disabled
Q-57 Select alarm restore reports to CS (0-1) (0) disabled
Q-58Select trouble restore reports to CS (0-1) (1) enabled
Q-59 Select bypass restores reports to CS (0-1) (0) disabled
Q-60 Select AC restore reports to CS (0-1) (1) enabled
Q-61 Select system low battery restore reports to CS (0-1) (1) enabled
Q-62 Select RF low battery restores reports to CS (0-1) (1) enabled
Q-63Select phone fail detect (0-1) (0) disabled
Q-64 Select smart test reports (0-1) (0) disabled
Q-65 Select RF jam causes trouble (0-1) (0) disabled
Q-66 Select daylight saving (0-1) (1) enabled
Q-67 Select daylight saving start month (01-12) (03) March
Q-68Select daylight saving start Sunday (1-7) (2) 2nd
Q-69 Select daylight saving end month (01-12) (11) November
Q-70 Select daylight saving end Sunday (1-7) (1) 1st
Q-71 Select system tamper causes trouble (0-1) (1) enabled
Q-72 Select quick bypass (0-1) (0) disabled
Q-73Select disarming keyfob after alarm (alert) (0-1) (0) disabled
Q-74 Select keyfob arm / disarm confirmation (0-1) (0) disabled
Q-75 Select auto unbypass for manual bypass (0-1) (1) enabled
Q-76 Select force bypass reports (0-1) (0) disabled
Q-77 Select event log (0-3) (3) all events
Q-78Select output (00-10) ‡(11) follows internal sounder alarm
Q-79 Select Z-Wave feature (0-3) (1) disabled but visible
Q-80Select Z-Wave switches feature (0-1) (0) disabled
Q-81Select Z-Wave thermostats feature (0-1) (0) disabled
Q-82Select Z-Wave door locks feature (0-1) (0) disabled
Q-83 Select temperature display units (0-1) (0) degrees Fahrenheit
Q-84Select services require master code (0-1) (0) disabled
Q-85Select master user access to zwave toolbox (0-1) (0) disabled
Q-86Select disable siren after two-way audio (0-1) (0) disabled
Q-87Select keyfob/remote arming mode on system not
ready (0-2)
(0) auto-bypass with zone
participation on restore
Q-88 Select siren mode (0-1) (0) sound for burglary and fire/CO
‡ Default set forSIA CP-01 compliance
♦ForUL985 Installations, this feature must be disabled