logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Fisher
  6. •
  7. Controllers
  8. •
  9. Fisher FIELDVUE DVC6200 User manual

Fisher FIELDVUE DVC6200 User manual

Other manuals for FIELDVUE DVC6200

9

This manual suits for next models

1

Other Fisher Controllers manuals

Fisher FIELDVUE DVC6200 Configuration guide

Fisher

Fisher FIELDVUE DVC6200 Configuration guide

Fisher 912 Series User manual

Fisher

Fisher 912 Series User manual

Fisher 1066 User manual

Fisher

Fisher 1066 User manual

Fisher 667 User manual

Fisher

Fisher 667 User manual

Fisher MR108 Series User manual

Fisher

Fisher MR108 Series User manual

Fisher FIELDVUEDVC6200f User manual

Fisher

Fisher FIELDVUEDVC6200f User manual

Fisher FIELDBUE DVC6200 User manual

Fisher

Fisher FIELDBUE DVC6200 User manual

Fisher FIELDVUE DVC6200 User manual

Fisher

Fisher FIELDVUE DVC6200 User manual

Fisher MR95L User manual

Fisher

Fisher MR95L User manual

Fisher ED User guide

Fisher

Fisher ED User guide

Fisher 627F User manual

Fisher

Fisher 627F User manual

Fisher 685 User manual

Fisher

Fisher 685 User manual

Fisher 6492HTM User manual

Fisher

Fisher 6492HTM User manual

Fisher FIELDVUE DVC6200p Configuration guide

Fisher

Fisher FIELDVUE DVC6200p Configuration guide

Fisher 4660 User manual

Fisher

Fisher 4660 User manual

Fisher FIELDVUE DVC6200 User manual

Fisher

Fisher FIELDVUE DVC6200 User manual

Fisher EMERSON VSX4 Series User manual

Fisher

Fisher EMERSON VSX4 Series User manual

Fisher 1301F User manual

Fisher

Fisher 1301F User manual

Fisher EZR User manual

Fisher

Fisher EZR User manual

Fisher FIELDVUE DVC6200 User manual

Fisher

Fisher FIELDVUE DVC6200 User manual

Fisher 2500 Series User manual

Fisher

Fisher 2500 Series User manual

Fisher 480-12 User manual

Fisher

Fisher 480-12 User manual

Fisher FIELDVUE DLC3010 User manual

Fisher

Fisher FIELDVUE DLC3010 User manual

Fisher 1061 User manual

Fisher

Fisher 1061 User manual

Popular Controllers manuals by other brands

Digiplex DGP-848 Programming guide

Digiplex

Digiplex DGP-848 Programming guide

YASKAWA SGM series user manual

YASKAWA

YASKAWA SGM series user manual

Sinope Calypso RM3500ZB installation guide

Sinope

Sinope Calypso RM3500ZB installation guide

Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

Isimet

Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

LSIS sv-ip5a user manual

LSIS

LSIS sv-ip5a user manual

Airflow Uno hab Installation and operating instructions

Airflow

Airflow Uno hab Installation and operating instructions

ABB ACS580-01 drives Hardware manual

ABB

ABB ACS580-01 drives Hardware manual

Panasonic GM1 Series Reference manual

Panasonic

Panasonic GM1 Series Reference manual

Emerson SW93 owner's manual

Emerson

Emerson SW93 owner's manual

AutoAqua Smart ATO micro SATO-120P manual

AutoAqua

AutoAqua Smart ATO micro SATO-120P manual

Panasonic FP? Positioning Unit RTEX Technical manual

Panasonic

Panasonic FP? Positioning Unit RTEX Technical manual

Alpha IP MIOB 21001 manual

Alpha IP

Alpha IP MIOB 21001 manual

Siemens OpenAir GMA 1 Series Mounting instructions

Siemens

Siemens OpenAir GMA 1 Series Mounting instructions

Surecom SR-629 user manual

Surecom

Surecom SR-629 user manual

Regulus SRS1 T Installation and operation manual

Regulus

Regulus SRS1 T Installation and operation manual

3M MicroTouch EX113 reference guide

3M

3M MicroTouch EX113 reference guide

KUHN TKS user manual

KUHN

KUHN TKS user manual

S&C PMH Instructions for operation

S&C

S&C PMH Instructions for operation

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
DVC6200/DVC2000
Digital Valve Controller on
Linear Actuator
Mounting Instructions
D103996X012
May 2014
Use these instructions to mount a FIELDVUE™
DVC6200/DVC2000 to a Linear Actuator.
WARNING
Avoid personal injury or property
damage from sudden release of process
pressure or bursting of parts. Before
performing any maintenance
operations:
Always wear protective clothing,
gloves, and eyewear.
Do not remove the actuator from
the valve while the valve is still
pressurized.
Disconnect any operating lines
providing air pressure, electric power, or
a control signal to the actuator. Be sure
the actuator cannot suddenly open or
close the valve.
Use bypass valves or completely
shut off the process to isolate the valve
from process pressure. Relieve process
pressure from both sides of the valve.
Vent the pneumatic actuator
loading pressure and relieve any
actuator spring precompression.
Use lock-out procedures to be sure
that the above measures stay in effect
while you work on the equipment.
Check with your process or safety
engineer for any additional measures
that must be taken to protect against
process media.
The visual aids in this document are for general
reference representation only. Refer to the
appropriate actuator instruction manual for actuator
installation, operation, maintenance, and parts
identification as this manual
may or may not include
all components shown for kit installation
.
1. Isolate the control valve from the process line
pressure and release pressure from both sides of the
valve body. Shut off all pressure lines to the actuator,
releasing all pressure from the actuator. Use lock-out
procedures to be sure that the above measures stay in
effect while you work on the equipment.
2. Attach connector arm assembly to stem block
using provided fasteners (including spacers and stud
bolts, if applicable).
2
DVC6200/DVC2000
Digital Valve Controller on
Linear Actuator
Mounting Instructions
D103996X012
May 2014
For fork-style connector arms remove the nuts and
indicator disk from the stem. Place the fork-style
extension arm flush with the bottom of the stem block
onto the stem. Reattach the indicator disk and nuts.
3. Loosely attach array to extension arm using
provided fasteners. (
Array not included with kit)
3
DVC6200/DVC2000
Digital Valve Controller on
Linear Actuator
Mounting Instructions
D103996X012
May 2014
4. Attach extension arm with array assembly to
connector arm.
5. Attach mounting plate to actuator using provided
hardware (including stud bolts, spacers, and
L-brackets, if applicable).
4
DVC6200/DVC2000
Digital Valve Controller on
Linear Actuator
Mounting Instructions
D103996X012
May 2014
6. Attach aligning template to mounting plate.
Adjust height of array until the middle line of the
aligning template is level with the corresponding line
of the array relative to stem block position.
***Care
needs to be taken to ensure that line the index marks
on the array do not move outside of the center index
mark on the alignment template***
5
DVC6200/DVC2000
Digital Valve Controller on
Linear Actuator
Mounting Instructions
D103996X012
May 2014
7. Attach insert assembly into the magnet housing
slot on the back of the device using the provided 3m
adhesive strip.
8. Remove aligning template. Attach device to
mounting bracket using provided fasteners.
6
DVC6200/DVC2000
Digital Valve Controller on
Linear Actuator
Mounting Instructions
D103996X012
May 2014
9. Attach remote mount air filter regulator (if
applicable).
Final Assembly
7
DVC6200/DVC2000
Digital Valve Controller on
Linear Actuator
Mounting Instructions
D103996X012
May 2014
Air Filter Regulator
Alignment Template
Connector Arm
Common Mounting Bracket
DVC2000
DVC6200
Extension Arm
Insert Assembly
Linear Feedback Array
Mounting Plate
Shield
Spacer
U-Bracket
8
DVC6200/DVC2000
Digital Valve Controller on
Linear Actuator
Mounting Instructions
D103996X012
May 2014
Neither Emerson, Emerson Process Management, Fisher, nor any of their affiliated entities assumes responsibility for the selection, use and
maintenance of any product. Responsibility for the selection, use and maintenance of any product remains with the purchaser and end user.
Fisherand FIELDVUE are marks owned by Fisher Controls International LLC, a member of the Emerson Process Management business unit of Emerson Electric
Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the
property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to
be construed as warranties or guarantees, express or implied, regarding the products or services
described herein or their use or applicability. We reserve the
right to modify or improve the designs or specifications of such products at any time without notice.
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
_____________________________________________________________________________________________________
© 2014 Fisher Controls International LLC. All right reserved.