FLIR A615 User manual

User’s manual
FLIR A6xx series


User’s manual
FLIR A6xx series
#T559950; r. AD/35720/35720; en-US iii


Table of contents
1 Legal disclaimer................................................................................1
1.1 Legal disclaimer .......................................................................1
1.2 Usage statistics ........................................................................ 1
1.3 Changes to registry ...................................................................1
1.4 U.S. Government Regulations......................................................1
1.5 Copyright................................................................................1
1.6 Quality assurance .....................................................................2
1.7 Patents...................................................................................2
1.8 EULATerms ............................................................................2
2 Safety information .............................................................................4
3 Notice to user ...................................................................................5
3.1 User-to-user forums ..................................................................5
3.2 Calibration...............................................................................5
3.3 Accuracy ................................................................................5
3.4 Disposal of electronic waste ........................................................5
3.5 Training ..................................................................................5
3.6 Documentation updates .............................................................5
3.7 Important note about this manual..................................................5
3.8 Note about authoritative versions..................................................5
4 Customer help ..................................................................................6
4.1 General ..................................................................................6
4.2 Submitting a question ................................................................6
4.3 Downloads..............................................................................7
5 Installation (FLIR A6xx cameras).........................................................8
5.1 General information...................................................................8
5.1.1 Explanation...................................................................8
5.1.2 Default installation paths ..................................................8
5.2 System requirements.................................................................8
5.2.1 Operating system...........................................................8
5.2.2 Hardware .....................................................................8
5.2.3 Software ......................................................................8
5.2.4 More information............................................................8
5.3 Installation...............................................................................9
5.3.1 General........................................................................9
5.3.2 Procedure ....................................................................9
6 Installation (FLIR A6xx sc cameras)................................................... 10
7 Quick start guide ............................................................................. 11
7.1 Quick start guide, FLIR A6xx series ............................................ 11
7.1.1 Download FLIR Tools .................................................... 11
7.2 Quick start guide, FLIR A6xx sc series......................................... 11
8 List of accessories and services ....................................................... 12
9 Mechanical installation .................................................................... 13
9.1 Mounting interfaces................................................................. 13
9.2 Notes on permanent installation ................................................. 13
9.3 Vibrations.............................................................................. 13
9.4 Further information.................................................................. 13
9.5 Cable strain relief.................................................................... 13
10 Mounting and removing lenses ......................................................... 15
10.1 Removing an infrared lens ........................................................ 15
10.2 Procedure............................................................................. 15
10.3 Mounting an infrared lens ......................................................... 15
10.3.1 Procedure .................................................................. 15
#T559950; r. AD/35720/35720; en-US v

Table of contents
11 Connectors, controls, and indicators ................................................. 16
11.1 Explanation ........................................................................... 16
12 Example system overviews............................................................... 17
12.1 FLIR A6xx series .................................................................... 17
12.1.1 Figure........................................................................ 17
12.1.2 Explanation................................................................. 17
12.1.3 Figure........................................................................ 18
12.1.4 Explanation................................................................. 18
12.1.5 Figure........................................................................ 18
12.1.6 Explanation................................................................. 19
12.2 FLIR A6xx sc series................................................................. 19
12.2.1 Figure........................................................................ 19
12.2.2 Explanation................................................................. 19
13 Digital I/O functionality..................................................................... 20
13.1 FLIR A615 and A655sc ............................................................ 20
14 Technical data.................................................................................21
14.1 Online field-of-view calculator .................................................... 21
14.2 Note about technical data ......................................................... 21
14.3 Note about authoritative versions................................................ 21
14.4 FLIR A615 15° ....................................................................... 22
14.5 FLIR A615 25° ....................................................................... 26
14.6 FLIR A615 45° ....................................................................... 30
14.7 FLIR A615 7°......................................................................... 34
14.8 FLIR A615 windowing 80°......................................................... 38
14.9 FLIR A655sc 15° .................................................................... 42
14.10 FLIR A655sc 25° .................................................................... 46
14.11 FLIR A655sc 45° .................................................................... 50
14.12 FLIR A655sc 7° ...................................................................... 54
14.13 FLIR A655sc 80° .................................................................... 58
15 Pin configurations and schematics.................................................... 62
15.1 Pin configuration for camera I/O connector ................................... 62
15.2 LED indicators ....................................................................... 62
16 Mechanical drawings ....................................................................... 63
17 CE Declaration of conformity ............................................................ 73
18 Network troubleshooting.................................................................. 75
19 Digital I/O connection diagrams ........................................................ 76
20 Cleaning the camera ........................................................................ 78
20.1 Camera housing, cables, and other items..................................... 78
20.1.1 Liquids....................................................................... 78
20.1.2 Equipment.................................................................. 78
20.1.3 Procedure .................................................................. 78
20.2 Infrared lens .......................................................................... 78
20.2.1 Liquids....................................................................... 78
20.2.2 Equipment.................................................................. 78
20.2.3 Procedure .................................................................. 78
20.3 Infrared detector ..................................................................... 78
20.3.1 General...................................................................... 78
20.3.2 Procedure .................................................................. 79
21 About FLIR Systems ........................................................................ 80
21.1 More than just an infrared camera .............................................. 81
21.2 Sharing our knowledge ............................................................ 81
21.3 Supporting our customers......................................................... 81
#T559950; r. AD/35720/35720; en-US vi

Table of contents
22 Glossary ........................................................................................83
23 Thermographic measurement techniques .......................................... 86
23.1 Introduction .......................................................................... 86
23.2 Emissivity.............................................................................. 86
23.2.1 Finding the emissivity of a sample.................................... 86
23.3 Reflected apparent temperature................................................. 89
23.4 Distance ............................................................................... 90
23.5 Relative humidity .................................................................... 90
23.6 Other parameters.................................................................... 90
24 History of infrared technology........................................................... 91
25 Theory of thermography................................................................... 94
25.1 Introduction ........................................................................... 94
25.2 The electromagnetic spectrum................................................... 94
25.3 Blackbody radiation................................................................. 94
25.3.1 Planck’s law ................................................................ 95
25.3.2 Wien’s displacement law................................................ 96
25.3.3 Stefan-Boltzmann's law ................................................. 97
25.3.4 Non-blackbody emitters................................................. 98
25.4 Infrared semi-transparent materials........................................... 100
26 The measurement formula.............................................................. 101
27 Emissivity tables ........................................................................... 105
27.1 References.......................................................................... 105
27.2 Tables ................................................................................ 105
#T559950; r. AD/35720/35720; en-US vii


Legal disclaimer
1
1.1 Legal disclaimer
All products manufactured by FLIR Systems are warranted against defective materials
and workmanship for a period of one (1) year from the delivery date of the original pur-
chase, provided such products have been under normal storage, use and service, and in
accordance with FLIR Systems instruction.
Products which are not manufactured by FLIR Systems but included in systems deliv-
ered by FLIR Systems to the original purchaser, carry the warranty, if any, of the particu-
lar supplier only. FLIR Systems has no responsibility whatsoever for such products.
The warranty extends only to the original purchaser and is not transferable. It is not appli-
cable to any product which has been subjected to misuse, neglect, accident or abnormal
conditions of operation. Expendable parts are excluded from the warranty.
In the case of a defect in a product covered by this warranty the product must not be fur-
ther used in order to prevent additional damage. The purchaser shall promptly report any
defect to FLIR Systems or this warranty will not apply.
FLIR Systems will, at its option, repair or replace any such defective product free of
charge if, upon inspection, it proves to be defective in material or workmanship and pro-
vided that it is returned to FLIR Systems within the said one-year period.
FLIR Systems has no other obligation or liability for defects than those set forth above.
No other warranty is expressed or implied. FLIR Systems specifically disclaims the im-
plied warranties of merchantability and fitness for a particular purpose.
FLIR Systems shall not be liable for any direct, indirect, special, incidental or consequen-
tial loss or damage, whether based on contract, tort or any other legal theory.
This warranty shall be governed by Swedish law.
Any dispute, controversy or claim arising out of or in connection with this warranty, shall
be finally settled by arbitration in accordance with the Rules of the Arbitration Institute of
the Stockholm Chamber of Commerce. The place of arbitration shall be Stockholm. The
language to be used in the arbitral proceedings shall be English.
1.2 Usage statistics
FLIR Systems reserves the right to gather anonymous usage statistics to help maintain
and improve the quality of our software and services.
1.3 Changes to registry
The registry entry HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Lsa
\LmCompatibilityLevel will be automatically changed to level 2 if the FLIR Camera Moni-
tor service detects a FLIR camera connected to the computer with a USB cable. The
modification will only be executed if the camera device implements a remote network
service that supports network logons.
1.4 U.S. Government Regulations
This product may be subject to U.S. Export Regulations. Please send any inquiries to ex-
portquestions@flir.com.
1.5 Copyright
© 2016, FLIR Systems, Inc. All rights reserved worldwide. No parts of the software in-
cluding source code may be reproduced, transmitted, transcribed or translated into any
language or computer language in any form or by any means, electronic, magnetic, opti-
cal, manual or otherwise, without the prior written permission of FLIR Systems.
The documentation must not, in whole or part, be copied, photocopied, reproduced,
translated or transmitted to any electronic medium or machine readable form without pri-
or consent, in writing, from FLIR Systems.
#T559950; r. AD/35720/35720; en-US 1

Legal disclaimer1
Names and marks appearing on the products herein are either registered trademarks or
trademarks of FLIR Systems and/or its subsidiaries. All other trademarks, trade names
or company names referenced herein are used for identification only and are the prop-
erty of their respective owners.
1.6 Quality assurance
The Quality Management System under which these products are developed and manu-
factured has been certified in accordance with the ISO 9001 standard.
FLIR Systems is committed to a policy of continuous development; therefore we reserve
the right to make changes and improvements on any of the products without prior notice.
1.7 Patents
One or several of the following patents and/or design patents may apply to the products
and/or features. Additional pending patents and/or pending design patents may also
apply.
000279476-0001; 000439161; 000499579-0001; 000653423; 000726344; 000859020;
001106306-0001; 001707738; 001707746; 001707787; 001776519; 001954074;
002021543; 002058180; 002249953; 002531178; 0600574-8; 1144833; 1182246;
1182620; 1285345; 1299699; 1325808; 1336775; 1391114; 1402918; 1404291;
1411581; 1415075; 1421497; 1458284; 1678485; 1732314; 2106017; 2107799;
2381417; 3006596; 3006597; 466540; 483782; 484155; 4889913; 5177595;
60122153.2; 602004011681.5-08; 6707044; 68657; 7034300; 7110035; 7154093;
7157705; 7237946; 7312822; 7332716; 7336823; 7544944; 7667198; 7809258 B2;
7826736; 8,153,971; 8,823,803; 8,853,631; 8018649 B2; 8212210 B2; 8289372;
8354639 B2; 8384783; 8520970; 8565547; 8595689; 8599262; 8654239; 8680468;
8803093; D540838; D549758; D579475; D584755; D599,392; D615,113; D664,580;
D664,581; D665,004; D665,440; D677298; D710,424 S; D718801; DI6702302-9;
DI6903617-9; DI7002221-6; DI7002891-5; DI7002892-3; DI7005799-0; DM/057692;
DM/061609; EP 2115696 B1; EP2315433; SE 0700240-5; US 8340414 B2; ZL
201330267619.5; ZL01823221.3; ZL01823226.4; ZL02331553.9; ZL02331554.7;
ZL200480034894.0; ZL200530120994.2; ZL200610088759.5; ZL200630130114.4;
ZL200730151141.4; ZL200730339504.7; ZL200820105768.8; ZL200830128581.2;
ZL200880105236.4; ZL200880105769.2; ZL200930190061.9; ZL201030176127.1;
ZL201030176130.3; ZL201030176157.2; ZL201030595931.3; ZL201130442354.9;
ZL201230471744.3; ZL201230620731.8.
1.8 EULA Terms
• You have acquired a device (“INFRARED CAMERA”) that includes software licensed
by FLIR Systems AB from Microsoft Licensing, GP or its affiliates (“MS”). Those in-
stalled software products of MS origin, as well as associated media, printed materials,
and “online” or electronic documentation (“SOFTWARE”) are protected by internation-
al intellectual property laws and treaties. The SOFTWARE is licensed, not sold. All
rights reserved.
• IF YOU DO NOT AGREE TO THIS END USER LICENSE AGREEMENT (“EULA”), DO
NOT USE THE DEVICE OR COPY THE SOFTWARE. INSTEAD, PROMPTLY CON-
TACT FLIR Systems AB FOR INSTRUCTIONS ON RETURN OF THE UNUSED DE-
VICE(S) FOR A REFUND. ANY USE OF THE SOFTWARE, INCLUDING BUT NOT
LIMITED TO USE ON THE DEVICE, WILL CONSTITUTE YOUR AGREEMENT TO
THIS EULA (OR RATIFICATION OF ANY PREVIOUS CONSENT).
•GRANT OF SOFTWARE LICENSE. This EULA grants you the following license:
◦ You may use the SOFTWARE only on the DEVICE.
◦NOT FAULT TOLERANT. THE SOFTWARE IS NOT FAULT TOLERANT. FLIR Sys-
tems AB HAS INDEPENDENTLY DETERMINED HOW TO USE THE SOFTWARE
IN THE DEVICE, AND MS HAS RELIED UPON FLIR Systems AB TO CONDUCT
SUFFICIENT TESTING TO DETERMINE THAT THE SOFTWARE IS SUITABLE
FOR SUCH USE.
#T559950; r. AD/35720/35720; en-US 2

Legal disclaimer1
◦NO WARRANTIES FOR THE SOFTWARE. THE SOFTWARE is provided “AS IS”
and with all faults. THE ENTIRE RISK AS TO SATISFACTORY QUALITY, PER-
FORMANCE, ACCURACY, AND EFFORT (INCLUDING LACK OF NEGLIGENCE)
IS WITH YOU. ALSO, THERE IS NO WARRANTYAGAINST INTERFERENCE
WITH YOUR ENJOYMENT OF THE SOFTWARE OR AGAINST INFRINGEMENT.
IF YOU HAVE RECEIVED ANY WARRANTIES REGARDING THE DEVICE OR
THE SOFTWARE, THOSE WARRANTIES DO NOT ORIGINATE FROM, AND
ARE NOT BINDING ON, MS.
◦ No Liability for Certain Damages. EXCEPT AS PROHIBITED BY LAW, MS SHALL
HAVE NO LIABILITY FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL OR IN-
CIDENTAL DAMAGES ARISING FROM OR IN CONNECTION WITH THE USE
OR PERFORMANCE OF THE SOFTWARE. THIS LIMITATION SHALL APPLY
EVEN IF ANY REMEDY FAILS OF ITS ESSENTIAL PURPOSE. IN NO EVENT
SHALL MS BE LIABLE FOR ANY AMOUNT IN EXCESS OF U.S. TWO HUN-
DRED FIFTY DOLLARS (U.S.$250.00).
◦Limitations on Reverse Engineering, Decompilation, and Disassembly. You
may not reverse engineer, decompile, or disassemble the SOFTWARE, except and
only to the extent that such activity is expressly permitted by applicable law not-
withstanding this limitation.
◦SOFTWARE TRANSFER ALLOWED BUT WITH RESTRICTIONS. You may per-
manently transfer rights under this EULA only as part of a permanent sale or trans-
fer of the Device, and only if the recipient agrees to this EULA. If the SOFTWARE
is an upgrade, any transfer must also include all prior versions of the SOFTWARE.
◦EXPORT RESTRICTIONS. You acknowledge that SOFTWARE is subject to U.S.
export jurisdiction. You agree to comply with all applicable international and nation-
al laws that apply to the SOFTWARE, including the U.S. Export Administration
Regulations, as well as end-user, end-use and destination restrictions issued by U.
S. and other governments. For additional information see http://www.microsoft.
com/exporting/.
#T559950; r. AD/35720/35720; en-US 3

Safety information
2
WARNING
Make sure that you read all applicable MSDS (Material Safety Data Sheets) and warning labels on con-
tainers before you use a liquid. The liquids can be dangerous. Injury to persons can occur.
CAUTION
Do not point the infrared camera (with or without the lens cover) at strong energy sources, for example,
devices that cause laser radiation, or the sun. This can have an unwanted effect on the accuracy of the
camera. It can also cause damage to the detector in the camera.
CAUTION
Do not use the camera in temperatures more than +50°C (+122°F), unless other information is specified
in the user documentation or technical data. High temperatures can cause damage to the camera.
CAUTION
Do not apply solvents or equivalent liquids to the camera, the cables, or other items. Damage to the bat-
tery and injury to persons can occur.
CAUTION
Be careful when you clean the infrared lens. The lens has an anti-reflective coating which is easily dam-
aged. Damage to the infrared lens can occur.
CAUTION
Do not use too much force to clean the infrared lens. This can cause damage to the anti-reflective
coating.
CAUTION
Applicability: Cameras with an automatic shutter that can be disabled.
Do not disable the automatic shutter in the camera for a long time period (a maximum of 30 minutes is
typical). If you disable the shutter for a longer time period, damage to the detector can occur.
NOTE
The encapsulation rating is only applicable when all the openings on the camera are sealed with their
correct covers, hatches, or caps. This includes the compartments for data storage, batteries, and
connectors.
CAUTION
Applicability: Cameras where you can remove the lens and expose the infrared detector.
Do not use the pressurized air from the pneumatic air systems in a workshop when you remove dust
from the detector. The air contains oil mist to lubricate the pneumatic tools and the pressure is too high.
Damage to the detector can occur.
#T559950; r. AD/35720/35720; en-US 4

Notice to user
3
3.1 User-to-user forums
Exchange ideas, problems, and infrared solutions with fellow thermographers around the
world in our user-to-user forums. To go to the forums, visit:
http://www.infraredtraining.com/community/boards/
3.2 Calibration
We recommend that you send in the camera for calibration once a year. Contact your lo-
cal sales office for instructions on where to send the camera.
3.3 Accuracy
For very accurate results, we recommend that you wait 5 minutes after you have started
the camera before measuring a temperature.
3.4 Disposal of electronic waste
As with most electronic products, this equipment must be disposed of in an environmen-
tally friendly way, and in accordance with existing regulations for electronic waste.
Please contact your FLIR Systems representative for more details.
3.5 Training
To read about infrared training, visit:
• http://www.infraredtraining.com
• http://www.irtraining.com
• http://www.irtraining.eu
3.6 Documentation updates
Our manuals are updated several times per year, and we also issue product-critical notifi-
cations of changes on a regular basis.
To access the latest manuals and notifications, go to the Download tab at:
http://support.flir.com
It only takes a few minutes to register online. In the download area you will also find the
latest releases of manuals for our other products, as well as manuals for our historical
and obsolete products.
3.7 Important note about this manual
FLIR Systems issues generic manuals that cover several cameras within a model line.
This means that this manual may contain descriptions and explanations that do not apply
to your particular camera model.
3.8 Note about authoritative versions
The authoritative version of this publication is English. In the event of divergences due to
translation errors, the English text has precedence.
Any late changes are first implemented in English.
#T559950; r. AD/35720/35720; en-US 5

Customer help
4
4.1 General
For customer help, visit:
http://support.flir.com
4.2 Submitting a question
To submit a question to the customer help team, you must be a registered user. It only
takes a few minutes to register online. If you only want to search the knowledgebase for
existing questions and answers, you do not need to be a registered user.
When you want to submit a question, make sure that you have the following information
to hand:
• The camera model
• The camera serial number
• The communication protocol, or method, between the camera and your device (for ex-
ample, HDMI, Ethernet, USB, or FireWire)
• Device type (PC/Mac/iPhone/iPad/Android device, etc.)
• Version of any programs from FLIR Systems
• Full name, publication number, and revision number of the manual
#T559950; r. AD/35720/35720; en-US 6

Customer help
4
4.3 Downloads
On the customer help site you can also download the following, when applicable for the
product:
• Firmware updates for your infrared camera.
• Program updates for your PC/Mac software.
• Freeware and evaluation versions of PC/Mac software.
• User documentation for current, obsolete, and historical products.
• Mechanical drawings (in *.dxf and *.pdf format).
• Cad data models (in *.stp format).
• Application stories.
• Technical datasheets.
• Product catalogs.
#T559950; r. AD/35720/35720; en-US 7

Installation (FLIR A6xx cameras)
5
5.1 General information
5.1.1 Explanation
The following programs are included on the ThermoVision System Tools & Utilities appli-
cation CD:
• FLIR IP Config: A set-up and configuration program to detect and find FLIR automa-
tion and science cameras on a network and automatically assign or manually set IP
addresses.
• FLIR IR Monitor: A program to control FLIR automation and science cameras on a
network. You typically use FLIR IR Monitor to change camera settings, lay out meas-
urement tools on the screen, set up alarms, etc.
• FLIR IR Camera Player: A PC-based remote control and video player for infrared cam-
eras from FLIR Systems.
• A link to a web installation of FLIR Axxx Control & Image Interfaces: An installation
that includes Interface Control Documents (ICDs), user documentation, and Ccode
examples. We recommend that you read the documentation.
5.1.2 Default installation paths
• C:\Program Files\FLIR Systems\FLIR IP Config
• C:\Program Files\FLIR Systems\FLIR IR Monitor
• C:\Program Files\FLIR Systems\FLIR IR Camera Player
• C:\Program Files\FLIR Systems\AXXX Control & Image Interfaces
Note Functionality in the PC programs is dependent on the camera model.
5.2 System requirements
5.2.1 Operating system
• Microsoft Windows XP Professional, with Service Pack 2 (SP2).
• Microsoft Windows Vista Ultimate 32-bit.
• Microsoft Windows 7, 32-bit and 64-bit.
5.2.2 Hardware
• Personal computer with a 2 GHz 32-bit or 64-bit processor.
• 1 GB of RAM or more.
• 20 GB of hard disk space.
• Super VGA (1024 × 768) or higher-resolution monitor.
• Support for DirectX 9 graphics with:
◦ WDDM driver
◦ 128 MB of graphics memory (minimum)
◦ Pixel Shader 2.0 (in hardware)
◦ 32 bits per pixel.
• DVD-ROM drive.
• Audio output.
• Keyboard and Microsoft mouse, or a compatible pointing device.
5.2.3 Software
Microsoft Internet Explorer 6 or later.
5.2.4 More information
For specific information about system requirements for the operating systems mentioned
above, visit http://www.microsoft.com/windows/.
#T559950; r. AD/35720/35720; en-US 8

Installation (FLIR A6xx cameras)
5
5.3 Installation
5.3.1 General
Last-minute changes and other important information can be found in the read-me file on
the CD-ROM. We recommend that you read this file before you install the programs.
Note
• If you experience problems during the installation, visit our Customer Help at http://
support.flir.com.
• You must be an Administrator or a user with Administrative Rights to install the
programs.
• A complete installation consists of several subinstallations, some of which are from
third-party vendors. Do not abort these subinstallations, as they are needed for the
complete installation.
• A complete installation can take up to 10 minutes to complete.
5.3.2 Procedure
Follow this procedure:
1. Close down all applications.
2. Insert the ThermoVision System Tools & Utilities CD-ROM into the CD drive on the
computer. The installation should start automatically.
Should the installation not start automatically, start Windows Explorer and double-
click SETUP.HTM on the CD-ROM.
3. Click one of the following:
• Install FLIR IP Config.
• Install FLIR IR Monitor.
• Install FLIR IR Camera Player.
• Install AXXX Control & Image Interfaces.
4. Follow the on-screen instructions.
#T559950; r. AD/35720/35720; en-US 9

Installation (FLIR A6xx sc
cameras)
6
The FLIR A6xx sc cameras are supported by the FLIR ResearchIR software. A download
card for this software is included in the camera package.
To install the software, follow the procedure in the user’s manual for FLIR ResearchIR.
The user’s manual is available in the User documentation >Software folder on the User
documentation CD-ROM that comes with the camera.
#T559950; r. AD/35720/35720; en-US 10

Quick start guide
7
7.1 Quick start guide, FLIR A6xx series
Follow this procedure:
1. Connect the power and Ethernet cables to the camera.
2. Connect the power cable to a power supply.
3. Connect the camera to the network, using the Ethernet cable.
4. Use to identify the unit in the network and set the IP address if necessary. Download
from http://tinyurl.com/o5wudd7.
5. Use FLIR Tools to set up and control the camera. For more information, see section
7.1.1 Download FLIR Tools, page 11.
7.1.1 Download FLIR Tools
FLIR Tools lets you quickly create professional inspection reports that clearly show deci-
sion makers what you’ve found with your IR camera.
Import, analyze, and fine-tune images easily. Then incorporate them into concise docu-
ments to share findings and justify repairs.
Go to the following website to download FLIR Tools:
http://support.flir.com/tools
7.2 Quick start guide, FLIR A6xx sc series
Follow this procedure:
1. Go to http://support.flir.com/rir4 and download FLIR ResearchIR Max.
2. Install FLIR ResearchIR Max.
3. Start FLIR ResearchIR Max.
When asked for the license key, enter the license key that is printed on the FLIR Re-
searchIR Max download card. The card is included with your camera.
4. Connect the camera to the computer using the provided Ethernet cable.
5. Start the camera. This displays a start-up dialog box in FLIR ResearchIR Max. If the
start-up dialog box is not displayed, go to View >Startup Dialog.
6. In the start-up dialog box, click the camera you want to connect to.
For more information about the installation and connection processes, see the FLIR Re-
searchIR Max manual.
#T559950; r. AD/35720/35720; en-US 11

List of accessories and services
8
IR lens, f=41.3 mm (15°) with case T197914
IR lens, f=24.6 mm (25°) with case T197922
IR lens, f=13.1 mm (45°) with case T197915
Close-up IR lens, 2.9× (50 µm) with case T198059
Close-up IR lens, 5.8× (100 µm) with case T198060
IR lens, f=6.5 mm (80°) with case T198065
IR lens, f=88.9 mm (7°) with case and support for
A6xx/A6xxsc
T198165
Close-up IR lens, 1.5× (25 µm) with case T198066
High temp option +300°C to 2000°C (+572°F to
3632°F) for FLIR A6xxsc and T6xx
T197896
Power cord EU 1910400
Power cord US 1910401
Power cord UK 1910402
Power supply, incl. multi plugs, for A3xx, A3xxsc,
A6xx and A6xxsc
T910922
Power supply for A3xx f, IP66 T911182
USB cable Std A <-> Mini-B 1910423
Ethernet cable CAT-6, 2m/6.6 ft. T951004ACC
Power cable, pigtailed 1910586ACC
Hard transport case for A3xx/A6xx series T197871ACC
Cardboard box for A3xx/A6xx series T197870ACC
Filter holder for A6xx lenses T126889ACC
FLIR Tools T198584
FLIR Tools+ (license only) T198583
FLIR IR Camera Player DSW-10000
FLIR ResearchIR 3 (license only) T198578
FLIR ResearchIR 3 Max (license only) T198574
FLIR ResearchIR Max + HSDR 4 T198697
FLIR ResearchIR Max + HSDR 4 T199014
FLIR ResearchIR Max + HSDR 4 Upgrade T199044
FLIR ResearchIR Max 4 T198696
FLIR ResearchIR Max 4 T199013
FLIR ResearchIR Max 4 Upgrade T199043
FLIR ResearchIR Standard 4 T198731
FLIR ResearchIR Standard 4 T199012
FLIR ResearchIR Standard 4 Upgrade T199042
ThermoVision™ System Developers Kit Ver. 2.6 T198567
ThermoVision™ LabVIEW® Digital Toolkit Ver.
3.3
T198566
One year extended warranty for A6xx, A6xxsc
series
T199827
Note FLIR Systems reserves the right to discontinue models, parts or accessories,
and other items, or to change specifications at any time without prior notice.