SPECIFICATIONS/DIMENSIONSStepTwo
Flashtype:Xenontube
Flashfrequency:1persecond
Strobelife:10Mcycles
Supplyvoltage:LC09:12‐36VDC
LC10:120VAC
LC10‐E:240VAC
Consumption:LC09:80mA
LC10:2Wattsmax.
LC10‐E:3Wattsmax.
Material:Polycarbonate
Enclosurerating:NEMA4X(IP65)
Color:Amber
UnpackingandInspection:Thefollowingitemsareincludedin
thispackage:
1StrobeAlert™(LC09‐1004,LC10‐1004orLC10‐1004‐E)
1 Junctionwire
1 Gasket
1 InstructionManual
Checktomakesurethatallpartsareincludedinthekitbefore
proceeding:
StrobeAlert™toLC10‐1001controller:The16Arelayinthe
LC10‐1001isanindependentSDPTrelay.WiththeStrobeAlert™
wiredNC;itcanbeusedasahighorlowlevelalarm,depending
onthesettingfortheinvertswitch.TheStrobeAlert™canalso
bewiredNO.PowertotheStrobeAlert™canbeprovidedfrom
thecontroller’ssupplyorfromanalternativesource.
ToLC10‐1001controller
ToLC09‐1001controller
StrobeAlert™toLC09‐1001controller:The6Arelayinthe
LC09‐1001isanindependentSDPTrelay.WiththeStrobeAlert™
wiredNC;itcanbeusedasahighorlowlevelalarm,depending
onthesettingfortheinvertswitch.TheStrobeAlert™canalso
bewiredNO.PowertotheStrobeAlert™canbeprovidedfrom
thecontroller’ssupplyorfromanalternativesource.
StrobeAlert™Alone
StrobeAlert™w/LC10,LC11orLC05series
StrobeAlert™w/LC06,LC09series

RevALCS9000013of4
SAFETYPRECAUTIONSStepThree
AboutThisManual:PLEASEREADTHEENTIREMANUALPRIORTOINSTALLINGORUSINGTHISPRODUCT.
ThismanualincludesinformationonthreedifferentmodelsofStrobeAlert™FlashAlarmfromFlowline:
LC09‐1004,LC10‐004andLC10‐1004‐E.Manyaspectsofinstallationandusearesimilarbetweenthethree
models.
User’sResponsibilityforSafety:FLOWLINEmanufacturesseveralmodelsofcontroller,withdifferent
mountingandswitchingconfigurations.Itistheuser’sresponsibilitytoselectacontrollermodelthatis
appropriatefortheapplication,installitproperly,performtestsoftheinstalledsystem,andmaintainall
components.
ElectricalShockHazard:Itispossibletocontactcomponentsonthecontrollerthatcarryhighvoltage,
causingseriousinjuryordeath.Allpowertothecontrollerandtherelaycircuit(s)itcontrolsshouldbe
turnedOFFpriortoworkingonthecontroller.Ifitisnecessarytomakeadjustmentsduringpowered
operation,useextremecautionanduseonlyinsulatedtools.Makingadjustmentstopoweredcontrollers
isnotrecommended.Wiringshouldbeperformedbyqualifiedpersonnelinaccordancewithallapplicable
national,stateandlocalelectricalcodes.
FlammableorExplosiveApplications:Sensormountcontrollersshouldnotbeusedwithexplosiveor
flammableliquids,whichrequireanintrinsicallysafeorexplosionproofrating.Ifyouareunsureofthe
suitabilityofacontrollerforyourinstallation,consultyourFlowlinerepresentativeforfurtherinformation.
InstallInaDryLocation:TheLC09&LC10seriesStrobeAlert™isliquid‐resistantandmadeof
Polycarbonate.Wheninstalledproperly,theStrobeAlert™andthehousingitisattachedtoarenot
designedtobeimmersed.Itshouldbemountedinsuchawaythatitdoesnotnormallycomeintocontact
withfluid.Refertoanindustryreferencetoensurethatcompoundsthatmaysplashontothecontroller
housingwillnotdamageit.Suchdamageisnotcoveredbythewarranty.
TestingwithaFlowlineController:
1. Ifconnected,turnOffpowertothecontrollerdevice(motor,alarmcircuit,etc).TurnOnpowertothe
controllerattheswitchorcircuitbreaker.ThegreenPowerLEDshouldturnOn.
2. Immersethesensor(s).TheamberINPUTLED(s)shouldturnOnimmediatelywhenliquidissensed.
3. TurntheTIMEDELAYpotentiometerfullcounter‐clockwiseforimmediateresponsefromtherelay.
DependingonthesettingoftheINVERTswitch,theredrelayLEDshouldcomeOnatthedesired
sensorcondition.AslightclickisaudiblewhentherelayisturnedOnandOff.
4. TurnOnpowertothecontrollerdeviceandtesttomakesuretherelaycircuitperformsasexpected.

4of4LCS900001RevA
WARRANTYStepNine
Warranty
Flowlinewarrantstotheoriginalpurchaserofitsproductsthatsuchproductswillbefreefromdefectsin
materialandworkmanshipundernormaluseandserviceinaccordancewithinstructionsfurnishedbyFlowline
foraperiodoftwoyearsfromthedateofmanufactureofsuchproducts.Flowline'sobligationunderthis
warrantyissolelyandexclusivelylimitedtotherepairorreplacement,atFlowline'soption,oftheproductsor
components,whichFlowline'sexaminationdeterminestoitssatisfactiontobedefectiveinmaterialor
workmanshipwithinthewarrantyperiod.Flowlinemustbenotifiedpursuanttotheinstructionsbelowofany
claimunderthiswarrantywithinthirty(30)daysofanyclaimedlackofconformityoftheproduct.Anyproduct
repairedunderthiswarrantywillbewarrantedonlyfortheremainderoftheoriginalwarrantyperiod.Any
productprovidedasareplacementunderthiswarrantywillbewarrantedforthefulltwoyearsfromthedate
ofmanufacture.
Returns
ProductscannotbereturnedtoFlowlinewithoutFlowline'spriorauthorization.Toreturnaproductthatis
thoughttobedefective,gotowww.flowline.com,andsubmitacustomerreturn(MRA)requestformand
followtheinstructionstherein.Allwarrantyandnon‐warrantyproductreturnstoFlowlinemustbeshipped
prepaidandinsured.Flowlinewillnotberesponsibleforanyproductslostordamagedinshipment.
Limitations
Thiswarrantydoesnotapplytoproductswhich:1)arebeyondthewarrantyperiodorareproductsforwhich
theoriginalpurchaserdoesnotfollowthewarrantyproceduresoutlinedabove;2)havebeensubjectedto
electrical,mechanicalorchemicaldamageduetoimproper,accidentalornegligentuse;3)havebeenmodified
oraltered;4)anyoneotherthanservicepersonnelauthorizedbyFlowlinehaveattemptedtorepair;5)have
beeninvolvedinaccidentsornaturaldisasters;or6)aredamagedduringreturnshipmenttoFlowline.Flowline
reservestherighttounilaterallywaivethiswarrantyanddisposeofanyproductreturnedtoFlowlinewhere:1)
thereisevidenceofapotentiallyhazardousmaterialpresentwiththeproduct;or2)theproducthasremained
unclaimedatFlowlineformorethan30daysafterFlowlinehasdutifullyrequesteddisposition.Thiswarranty
containsthesoleexpresswarrantymadebyFlowlineinconnectionwithitsproducts.ALLIMPLIED
WARRANTIES,INCLUDINGWITHOUTLIMITATION,THEWARRANTIESOFMERCHANTABILITYANDFITNESSFOR
APARTICULARPURPOSE,AREEXPRESSLYDISCLAIMED.Theremediesofrepairorreplacementasstatedabove
aretheexclusiveremediesforthebreachofthiswarranty.INNOEVENTSHALLFLOWLINEBELIABLEFORANY
INCIDENTALORCONSEQUENTIALDAMAGESOFANYKINDINCLUDINGPERSONALORREALPROPERTYORFOR
INJURYTOANYPERSON.THISWARRANTYCONSTITUTESTHEFINAL,COMPLETEANDEXCLUSIVESTATEMENT
OFWARRANTYTERMSANDNOPERSONISAUTHORIZEDTOMAKEANYOTHERWARRANTIESOR
REPRESENTATIONSONBEHALFOFFLOWLINE.Thiswarrantywillbeinterpretedpursuanttothelawsofthe
StateofCalifornia.Ifanyportionofthiswarrantyisheldtobeinvalidorunenforceableforanyreason,such
findingwillnotinvalidateanyotherprovisionofthiswarranty.
Forcompleteproductdocumentation,videotraining,andtechnicalsupport,gotowww.flowline.com.
Forphonesupport,call562‐598‐3015from8amto5pmPST,Mon‐Fri.
(PleasemakesureyouhavethePartandSerialnumberavailable.)
This manual suits for next models
1
Table of contents
Popular Security System manuals by other brands

Climax Technology
Climax Technology HSGW-Gen2-V1 user manual

Xtralis
Xtralis ADPRO Presidium Mini Installation and user manual

Optex Morse
Optex Morse Genesys 824 Alpha owner's manual

Cocoon
Cocoon IT214054 instruction manual

Hiltron security
Hiltron security SCHSW manual

Powerex
Powerex MA24 Series Installation & operating instructions