INSTRUCTION
MANUAL
INSTALLATION
The installation should be done by a qualified technician.
In case of substitution of a pump verify that the model on
the label is the same of the original pump to avoid damage
due to different hydraulic or electric characteristics or fluid
compatibility. The power supply must be consistent with
the electrical data stamped on the pump, with particular
regard to voltage and frequency. Verify also that, during
installation, the machine to which the pump is going to be
mounted is disconnected from the power supply.
For the models in epoxy resin without the double insulation
(class I device) the grounding wire is necessary. In case
of prolonged working the coil gets hot. In case the pump
operates in a closed space or with temperature higher than
50 °C (122 F), a thermal protector is necessary. Electric
wires, rubber pipes or any part sensible to heat should not
be in contact with the pump. Also avoid installing electric or
electronic components nearby the pump, because a leak
might damage them. A leaking pump has to be repaired or
replaced. It’s advisable to install the pump under the tank in
order to avoid cavitation. If the pump is directly connected
to the line, the inlet pressure shouldn’t be higher than 2 bar
(29 psi). Do not install the pump plunged in the liquid if this
is not a dielectric one. The vibrations during operation can
be damped by utilising the stands available from Fluid-o-
Tech; this will reduce noise or resonance of machine parts.
WARNING
Before installation, in order to improve the subsequent
correct priming of the pump, it is suggested to blow
compressed air from the suction line for three seconds.
OPERATING CONDITIONS
Make sure that the pumped fluid is compatible with the
materials of the pump. Avoid as well to use liquids with
temperature higher than 70 °C (158 F). The pump is
designed to handle clean water. Particles in the fluid may
cause failure of the pump. For any application involving
different fluids or unusual operating conditions please
verify the compatibility with Fluid-o-Tech. It’s necessary
to mount a 10 µm filter before the pump if the fluid
contains particles or extraneous objects and to keep it
clean periodically; a dirty filter (or an insufficient surface
area) doesn’t let the liquid flow causing cavitation and
fast wear of the internal parts. Priming and operating the
pump at more than 0.5 m higher than the water line may
cause prolonged dry running or cavitation. The pump
shouldn’t work with the outlet clogged or at maximum
pressure because overheating of the pump and breaking
of some parts of the circuit may occur under these
circumstances. Models with relief valve are available: in
case of obstruction of the pipe the pressure can’t raise
over the set valve. The relief valve is set by Fluid-o-Tech
at 10 bar (145 psi) for the models 1006 and 1106 and
6 bar (88 psi) for the models 1008 and 1108, except for
specific request of the customer. For a correct use of the
pump, the working pressure should be at least 1 bar (14.5
psi) lower than the set value. The 1006 series should work
with back-pressure not lower than 1.5 bar (22 psi). The
1008 series should work with back-pressure not lower
than 1 bar (14.5 psi). The 1106 and 1108 series may work
without back pressure. It’s strongly recommended not
letting the pump run dry. Dry running causes overheating
and wears out the internal parts of the pump. If the
pump is not equipped with a relief valve it’s advisable to
check that the system is protected (it’s possible to use an
external relief valve or a pressure switch to interrupt the
liquid flow) against accidental overpressures (electrovalves
shutting or a clogged outlet) which may compromise the
integrity of the circuit. If the pump is equipped with a relief
valve, a storage tank or a system to recover the liquid
dripping through the valve is necessary. The relief valve
is not and must not be used as a flow regulator. Models
equipped with a flow regulator (restrictor) are available.
The flow depends on the working pressure. If the pump
is powered by an electronic circuit, this must be able to
supply the necessary current (pulsating current with peaks
equals to 1.8 times the average).
SOLENOID PUMPS MONO SERIES
www.fluidotech.com
Fluid-o-Tech Int’l Inc.
161 Atwater St.,
Plantsville CT (USA) 06479
Tel. +1 (860) 276 9270
Fax +1 (860) 620 0193
[email protected]
Fluid-o-Tech Int’l Inc. Japan
2nd Floor, 4-3-8, Espoir Todoroki,
Todoroki, Setagaya, Tokyo 158-0082
Tel. +81 (0) (3) 6432 1812
Fax +81 (0) (3) 6432 1813
[email protected]
Fluid-o-Tech Asia (Shanghai) Co., Ltd.
2/F, Factory building 6 (1), No. 258, Zhijiang Road,
Fengxian District, Shanghai City, Z.P.: 201499 China
Tel. +86 (021) 67100 838
Fax +86 (021) 67100 605
[email protected]
Fluid-o-Tech srl
Via Leonardo da Vinci, 40
20094 Corsico, Milano, Italy
Tel. +39 02 9995 01
Fax +39 02 9995 0999
[email protected]
MANUAL - VIP en - 06/21 Ed.
Fluid-o-Tech reserves the right to alter the specifications indicated in this catalogue at any time and without prior notice.
WORKING CYCLES
Different coils in Nylon or Epoxy resin from 24 V AC,
110 V AC, 220 V AC, 50 and 60 Hz are available. The
maximum continuous operation for the models with a 70
Watt coil is 5 minutes, with 1 minute stop (intermittent
duty). If prolonged or abnormal operation is possible
(lack of water or clogged outlet) it is necessary to use a
thermal protector. The models equipped with the “IF” coil
(70 W, 110 V, 60 Hz) have the following limitations:
• The pump and quick connect terminals must be
provided with a suitable enclosure in accordance with
the requirements of the end-use Standard.
• The quick connect terminals are not suitable for field
wiring purposes.
• The suitability of the pumps for a duty cycle other than
5 min on/30 s off, and at an ambient temperature
greater than 40 °C (104 F), must be evaluated in the
end product.
• The suitability of the pump for control of a water
source greater than atmospheric pressure, or at a
water temperature greater then 25 °C (77 F), must be
evaluated in the end product.
• Temperatures of the coil windings are to be monitored
in the end product by the change-of-resistance
method, and are not to exceed Class A limits (110 °C).
• The suitability of the permanence of markings shall be
determined in the end product.
• The end product shall provide provisions for
preventing the dry operation of the pump, and over-
current protection in the case of blocked plunger.
STANDARD MAINTENANCE, REPLACEMENT OF
PARTS SUBJECT TO WEAR, SPARE PARTS
Solenoid pumps do not need any maintenance. In case
of break-down the replacement of worn out parts should
be done by Fluid-o-Tech or authorized repair centers.
Every pump is marked with production date, model
number and electric characteristics of the coil.
WARRANTY
Every new pump manufactured by Fluid-o-Tech
is guaranteed to be free of defects in workmanship
and material when leaving the factory for a period of
12 months from the production date stamped on the
pumps’ labels or 400 hours of operation – whichever
comes first – within the performances prescribed in Fluid-
o-Tech technical documents, with pure water (max 10
micron particles); applying maximum working cycle as
prescribed into product instruction manual. Fluid-o-Tech
will repair or replace at its judgement part or all of the
product not conforming to this warranty. Fluid-o-Tech’s
responsibility under this warranty is limited to the repair
or replacement of defective equipment returned to us on
a D.A.P. basis, providing that our analysis discloses that
such part or parts were defective at the time of sale.
The warranty is not recognized if:
• The identifying label is missing
• The instructions are disregarded
• The pump has been disassembled or modified by
anyone other than a Fluid-o-Tech engineer
• The pump operated dry or in water starvation.
Extraneous solid particles have compromised the normal
operation of the pump
The wiring is burned due to one of the following reasons:
- continuous operation
- voltage or frequency different from the ones stamped
on the label
It is responsibility of the user to predispose, in the
machine where the pump will be used, all the necessary
protections in order to avoid at all times the dry running
of the pump.
The Purchaser/User is responsible for the disposal or
recycling of the product at end of its use or lifetime. For
more information on proper disposal method, please
contact Fluid-o-Tech Customer Care.
Pump Connections
CERTIFICATIONS
This product is supplied with the mark “CE” that grants
its conformity to European directives, mentioned in
the product declaration of conformity, provided that
it is utilized in accordance to the operating conditions
reported on this instruction manual.
129 mm
55 mm
Inlet
Outlet

Other fluid-o-tech Water Pump manuals

fluid-o-tech DGD PRO Series User manual

fluid-o-tech

fluid-o-tech DGD PRO Series User manual

fluid-o-tech ROTOFLOW User manual

fluid-o-tech

fluid-o-tech ROTOFLOW User manual

fluid-o-tech DGD Series User manual

fluid-o-tech

fluid-o-tech DGD Series User manual

fluid-o-tech MG 200 Series User manual

fluid-o-tech

fluid-o-tech MG 200 Series User manual

fluid-o-tech FG Series User manual

fluid-o-tech

fluid-o-tech FG Series User manual

fluid-o-tech TMFR User manual

fluid-o-tech

fluid-o-tech TMFR User manual

fluid-o-tech MG Series User manual

fluid-o-tech

fluid-o-tech MG Series User manual

fluid-o-tech TP30 Series User manual

fluid-o-tech

fluid-o-tech TP30 Series User manual

fluid-o-tech MK series User manual

fluid-o-tech

fluid-o-tech MK series User manual

Popular Water Pump manuals by other brands

DAYLIFF DS Installation & operating manual

DAYLIFF

DAYLIFF DS Installation & operating manual

Lafferty 920118 Installation & operation instructions

Lafferty

Lafferty 920118 Installation & operation instructions

Flux F 550 S Series Original main operating instructions

Flux

Flux F 550 S Series Original main operating instructions

Gormann-Rupp Pumps 6500 Series Installation, operation and maintenance manual

Gormann-Rupp Pumps

Gormann-Rupp Pumps 6500 Series Installation, operation and maintenance manual

POMPE CUCCHI MX Series Operating and maintenance manual

POMPE CUCCHI

POMPE CUCCHI MX Series Operating and maintenance manual

Barmesa Pumps BVL Series Installation, operation & maintenance manual

Barmesa Pumps

Barmesa Pumps BVL Series Installation, operation & maintenance manual

Goulds Prime Line SP SPH130 Installation, operation and maintenance instructions

Goulds

Goulds Prime Line SP SPH130 Installation, operation and maintenance instructions

IMI PNEUMATEX Transfero TVI Connect 19.1 H Install

IMI PNEUMATEX

IMI PNEUMATEX Transfero TVI Connect 19.1 H Install

Hozelock FLOWMAX 7500 manual

Hozelock

Hozelock FLOWMAX 7500 manual

Grundfos DMX Series Installation and operating instructions

Grundfos

Grundfos DMX Series Installation and operating instructions

Corken Z Series Installation, operation & maintenance manual

Corken

Corken Z Series Installation, operation & maintenance manual

Graco 205394 Instructions-parts list

Graco

Graco 205394 Instructions-parts list

Intex Krystal Clear 604 owner's manual

Intex

Intex Krystal Clear 604 owner's manual

Lincoln 9917 Installation and maintenance guide

Lincoln

Lincoln 9917 Installation and maintenance guide

Pulsafeeder GLM1 Installation operation & maintenance

Pulsafeeder

Pulsafeeder GLM1 Installation operation & maintenance

Waterous CM Series OVERHAUL INSTRUCTIONS

Waterous

Waterous CM Series OVERHAUL INSTRUCTIONS

BE SP-500TD user manual

BE

BE SP-500TD user manual

Warren rupp SandPIPER EB3-M Service & operating manual

Warren rupp

Warren rupp SandPIPER EB3-M Service & operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.