Forza SL402UL User manual

User Manual
Uninterruptible Power System
SL402UL/SL-602UL/SL-802UL/SL-1012UL
3 -
y ear
war r ant y **

1
2
1
2
SL-402ULSL-802UL/SL-602UL
SL-1012UL
Important safety instructions (Save this sheet)
This unit is intended for installation in a controlled environment (temperature-controlled indoor area location, free of conductive
contaminants). Avoid installing the UPS where there is standing or running water, or excessive humidity.
To reduce the risk of overheating, do not cover the cooling vents. Avoid exposing the UPS to direct sunlight or installing the unit
near heat-emitting appliances, such as electric heaters or furnaces.
Do not connect non-computer related peripheral devices, such as medical devices, life-support equipment, microwave ovens, or
vacuum cleaners to the UPS.
Do not connect any power strip or surge suppressor to the UPS.
Do not plug the UPS AC input power cord into its own output.
Do not allow any kind of liquid or foreign object to enter this UPS unit. Do not place beverages or any other containers with liquid
on or nearby the unit.
During the installation of this equipment, make sure that the sum of the leakage currents of the UPS and the connected loads shall
not exceed 3.5mA. In case of emergency, turn the power switch “off” and disconnect the power cord from the AC mains outlet.
Unplug the UPS before cleaning, and do not use liquid or spray detergents.
Never try to open or mutilate a battery. Released electrolyte is harmful to the skin and eyes, and also can be toxic.
Servicing of batteries should be performed or supervised by experts who possess the knowledge to closely follow all required
precautions.
When replacing the battery, make sure to use the same type and number of sealed lead-acid batteries specified.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
CAUTION!
Upon opening the box, make sure the following items are included:
Remove the UPS from its package and look for damages that may have occurred during shipping. If any damage is discovered, repack
the unit and return it to the place of purchase.
1. UPS unit
2. User manual
3. CD with software
4. USB cable
5. Warranty certificate
Thank you for purchasing the SL402UL/SL-602UL/SL-802UL/SL-1012UL Line Interactive Smart UPS from Forza. To enjoy all
the features and benefits of this unit, we encourage you to read this manual and follow the installation and operation instructions
thoroughly.
This unit features a state of the art LCD display and powerful features designed to protect your equipment and sensitive electronics
from voltage fluctuations and power failures. Reliable and interrupted performance is possible through the integration of voltage
regulation, surge suppression and backup capabilities –all in a single unit. The new SL includes a power management software, with
the latest in system monitoring technology. The SL UPS system comes in 400, 600, 800 and 1000 configurations.
1. Introduction
2. Package content
2.1 Inspection
• A battery can present the risk of short-circuit current and electrical shock. The following precautions should be taken:
1) Remove watches, rings, or other metal objects from your hand.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not place tools or metal parts on the top of batteries.
5) Disconnect charging source prior to connecting or disconnecting battery terminals.
• Attention: potentially hazardous voltages from the battery can still be present even after disconnecting the UPS from the AC mains.
Therefore, the positive and negative terminals of the battery shall be disconnected prior to performing any maintenance or repair
inside the unit.
• The UPS contains internal 12VDC, sealed, lead-acid batteries.
• Do not dispose of batteries in a fire. Batteries may explode if exposed to high temperatures.
Safe handling of batteries
Attention: Risk of electric shock
3. Product overview
SL402UL/SL-602UL/SL-802UL/SL-1012UL
Rear view
3
4
5
6
8
7
8
3
4
5
6
7
4
5
7
6
3
8
Front view

Install the UPS unit in any protected environment that provides adequate airflow around the unit, and free from excessive dust,
corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity
is high. For best performance, keep the indoor temperature between 0°C and 40°C with a relative humidity within 0-90%. Place the
UPS unit at least 20 cm away from monitors to avoid interference.
4. Installation and operation
4.1 Choose a location
Plug in the AC cord to a wall outlet. Please make sure there are no devices plugged into the unit.
This unit is shipped from the factory with its internal battery fully charged; however, some charge may be lost during shipping. So for
best results, it is recommended to recharge them for at least 6 hours prior to initial use. The unit charges its batteries whenever it is
connected to the utility power.
4.2 Connection of the UPS to utility power and initial charging
Connect one device into each power receptacle provided on the back of the UPS. Plug sensitive equipment into battery backup
outlets. Battery power is automatically provided in case of a power outage.
NOTE: Make sure that the UPS is powered on to protect all important devices from data loss during power failure.
4.3 Connection of loads to the UPS
In order to monitor the UPS status and to allow for unattended shutdown of your operating system in the event of an extended power
failure, connect the supplied USB cable between the USB port of your PC and the one located on the back of the UPS. The UPS will
be detected automatically in this case.
4.4 USB communication port
To start up the UPS, push down the power switch. To turn off the unit, press the button again.
4.5 Powering on and off the UPS
ForzaTracker is a new generation of UPS monitoring software, which provides user-friendly interface to monitor and control your UPS
system. This unique software provides safe auto shutdown for multi-computer systems during power failures. With this software, users
can remotely monitor and control any UPS on the same LAN, no matter how far the unit is located.
5. Software installation – Forza Tracker
1. LCD touchscreen display
2. Power button
3. USB communication port
4. Circuit breaker
5. AC input
6. Battery backup receptacles
7. Surge-only protected receptacles
8. RJ-45/11 Network, fax and modem surge protection
6 hours
Never connect a power strip or surge suppressor to the UPS.
NEVER connect a laser printer or scanner to the UPS unit. These devices generate
high transient voltages that cause permanent damage to the UPS.
1. Go to the website: www.forzaups.com/us/driver-downloads/
2. Choose the type of operation system and follow the instructions on the website to download the software.
3. When downloading all required files from the internet, enter the serial No: 5242-87f6-64re-di8d-986u to install the software
(include the hyphens).
4. When your computer restarts, the management software will appear as a green plug icon located in the system tray, near
the clock.
5. To access the Forza Tracker management software as an administrator, you must enter the password: 111296.
Installation procedure:
6. LCD display description
UPS mode LCD Description
When the UPS is initially powered on, it
remains in this mode for 4 seconds
When the AVR function is active,
the icon blinks every second
The icon is displayed on the
screen
Information is displayed in the following
order when the LCD screen is touched:
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
UPS power on
AC mode
When the UPS is overloaded, the unit
beeps every 0.5 second to warn about
such condition
Overload in AC mode
220
75 100
220

If the UPS system does not operate correctly, use the table below to troubleshoot the problem.
7. Troubleshooting guide
UPS mode LCD Description
When the UPS is overloaded, the unit
beeps every 0.5 second to warn about
such condition
Overload in battery
mode
The icon is displayed on the
screen
Fault condition LCD Solution
Disconnect short-circuited
loads and restart the UPS
The output is short circuited
Remove all connected loads
and restart the UPS
Overload fault
Call for technical assistance
immediately
Overcharge
Please replace the batteryDefective or severely
discharged battery
Call for technical assistance
immediately
High output voltage
1. Turn off and wait for the unit
to cool
2. Or remove excessive loads
and wait for the unit to cool
Over-temperature
The icon is displayed when
battery level is low
When the UPS is in battery mode and
battery voltage begins to dwindle, the unit
will beep once every 10 seconds. Also when
the LCD is touched, the information will be
displayed in the following order:
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Battery mode
8. Technical specifications
* 2 years on batteries
** Calculated using a single PC plus monitor
MPN SL-402UL SL-602UL SL-802UL SL-1012UL
General
Input
Output
Battery
Voltage regulation
Frequency regulation
Protection
Special features
Environment
Line/Battery transfer
Alarms/Indicators
Capacity 400VA/240W 600VA/360W 800VA/480W 1000VA/600W
12V/4.5Ah (1) 12V/7Ah (1) 12V/9Ah (1) 12V/7Ah (2)
18 min** 25 min** 32 min** 50 min**
Physical appearance
Additional information
Nominal voltage
Voltage range
Frequency
AC plug style
220V
162-268VAC
45-65Hz (autosensing)
NEMA 5-15P
Nominal voltage
Frequency
Frequency stability
Waveform
Total outlets
Full battery with surge
protection outlets
Surge protection only
outlets
Network protection
Phone/fax/modem
protection
USB management
Battery type and quantity
8.2lb 9.7lb 11lb 17.6lb
220V +/- 10%
50/60Hz
+/- 1Hz battery mode
Modified sine wave
6 (NEMA 5-15R) 8 (NEMA 5-15R)
510J 660J
-4-113°F -4 to 122°F
11.8x3.9x 5.6in 12.6x5.1x7.2in
4 5 6
RJ-11
RJ-45
2 1 2
Included with ForzaTracker software
Warranty 3 years *
268V +/- 5%
162-204V +/- 5%
236-268V +/- 5%
162V +/- 5%
4 hours to 90% after complete discharge
High cutoff
Boost 1
Buck
Low cutoff
IncludedAutomatic
frequency selection
2-4ms
162VAC +/- 5%
268VAC +/- 5%
Typical transfer time
Low line transfer to battery
High line transfer to battery
Easy to read touch screen LCD with a blue backlight that displays input voltage,
output voltage, battery capacity,load level, and UPS status
Battery mode: Sounds every 10 seconds
Low battery: Sounds every second
Overload: Sounds every 0.5 second
Fault: Sounds continuously
Visual indicators
(LCD display)
Audible tone
Voltage regulation, overload, discharge and overcharge protectionFull protection
Joules
Included
Included
“Cold start” option
Auto charge
32-104°F
0-90% non-condensing
<40dB at one meter
Operating temperature
Storage temperature
Relative humidity
Audible noise
Power switch
Housing
Color
Dimensions
Weight
Push button
ABS fire retardant plastic
Black
Recharge time
Backup time
220
50 75
0

NOTAS
NOTES
This manual suits for next models
3
Table of contents
Other Forza UPS manuals

Forza
Forza FDC-1002T-C User manual

Forza
Forza FDC-1502R User manual

Forza
Forza FDC-003K User manual

Forza
Forza FDC-106K User manual

Forza
Forza Elipse Series User manual

Forza
Forza Elipse Series User manual

Forza
Forza Atlas 2-3KVA User manual

Forza
Forza FIO-P11K12 User manual

Forza
Forza FDC-1001RUL User manual

Forza
Forza SL402UL-C User manual

Forza
Forza HT-752LCD-C User manual

Forza
Forza FDC-106KMR-ISO User manual

Forza
Forza FX-1500LCD User manual

Forza
Forza SL-802UL-A User manual

Forza
Forza DC-140USB User manual

Forza
Forza XG-1201LCD User manual

Forza
Forza SL-1501UL User manual

Forza
Forza HT-650LCD User manual

Forza
Forza FDC-1000T User manual

Forza
Forza FDC-2012R-I User manual