Amika®
ENTERAL NUTRITION PUMP
PICTORIAL REFERENCE GUIDE
Empty battery
Connect pump to
mains supply
immediately.
Pump error alarm
Note the technical
Error code (Err xyz)
and contact your
biomedical
department.
Empty bag/ air in
set alarm
Change feed
container, check
connection to
giving set and
ensure giving set is
fully primed.
Door open alarm
Close pump door.
Ta rget volume
almost reached
message
Continue feeding
or end feeding.
Ta rget volume
reached alarm
End feeding or
proceed to the
next step
Downstream
occlusion alarm
Check that pumpset/
feeding tube is clear
of any occlusion after
the pump, at the
patient side.
Upstream
occlusion alarm
Check that pump
set is clear of any
occlusions between
the container and
the pump
Set installation alarm
Check giving set
position above and
below pump
mechanism and
insert it correctly
Mute alarm (if necessary)
Detect the cause and proceed to the appropriate action
Release alarm Resume feeding
If alarm occurs: Start Reminder
Proceed to next step
or switch pump off.
What to do if...
caring
for
life
FOR
ANY
ENQUIRIES
OR
INFORMATION
CALL
THE
HOMECARE
24
HOUR
FREEPHONE
HELPLINE
NUMBER
0808
100
1990
caring
for
life
ENTERAL NUTRITION PUMP PICTORIAL REFERENCE GUIDE
SETTING UP THE PUMP
Close the pinch clamp on the giving set and then
connect to the EasyBag or feed container.
Open the pump door.
Turn the Amika®pump on – pressing
the on/off button.
Place the giving set pinch clamp in line with
the downward arrow until it “clicks” in place.
Press the automatic priming key, and then
press the start button.
Place the giving set tube
straight inside the tube guide.
Set the desired flow rate by
pressing the +/- keys until the
desired volume is reached.
When priming is complete,
press the start button again.
To stop feeding at any point,
press the stop key. When
feeding has finished or your
target volume is reached, press
the stop key.
If you need to reset the
progress bar after target
volume is reached, press the
stop key for 2-3 seconds.
To switch off the pump
press the on/off button
until the countdown is
completed.
Connect the giving set to the
patient’s enteral feeding tube.
Press the start key to
start feeding.
Set the target volume by
pressing the +/- keys until the
desired volume is reached.
Close the door, push down the
lever to lock it firmly in place.
01 02
06
03
14
07
04
0908
11 12 13
05
10

Other manuals for Amika

3

Other Fresenius Kabi Medical Equipment manuals

Fresenius Kabi Ambix activ User manual

Fresenius Kabi

Fresenius Kabi Ambix activ User manual

Fresenius Kabi Volumat Agilia User manual

Fresenius Kabi

Fresenius Kabi Volumat Agilia User manual

Fresenius Kabi Volumat MC Agilia User manual

Fresenius Kabi

Fresenius Kabi Volumat MC Agilia User manual

Fresenius Kabi AGILIA SP MC WIFI CA User manual

Fresenius Kabi

Fresenius Kabi AGILIA SP MC WIFI CA User manual

Fresenius Kabi Volumat MC Agilia User manual

Fresenius Kabi

Fresenius Kabi Volumat MC Agilia User manual

Fresenius Kabi Freka PEG FR15 ENFit User manual

Fresenius Kabi

Fresenius Kabi Freka PEG FR15 ENFit User manual

Fresenius Kabi Volumat MC Agilia Setup guide

Fresenius Kabi

Fresenius Kabi Volumat MC Agilia Setup guide

Fresenius Kabi OPTIMA PT-VS-S User manual

Fresenius Kabi

Fresenius Kabi OPTIMA PT-VS-S User manual

Fresenius Kabi agilia User manual

Fresenius Kabi

Fresenius Kabi agilia User manual

Fresenius Kabi APPLIX SMART User manual

Fresenius Kabi

Fresenius Kabi APPLIX SMART User manual

Fresenius Kabi CompoSeal Universal User manual

Fresenius Kabi

Fresenius Kabi CompoSeal Universal User manual

Popular Medical Equipment manuals by other brands

Itamar Medical WatchPAT Operation manual

Itamar Medical

Itamar Medical WatchPAT Operation manual

PROTEOR 1P650 KNEE Assembling and adjustment instructions

PROTEOR

PROTEOR 1P650 KNEE Assembling and adjustment instructions

Liberate Medical VentFree user manual

Liberate Medical

Liberate Medical VentFree user manual

Dicarre DA20 user guide

Dicarre

Dicarre DA20 user guide

Stryker Medical M Series Operation manual

Stryker Medical

Stryker Medical M Series Operation manual

Invacare ScanBed 750 user manual

Invacare

Invacare ScanBed 750 user manual

Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Getinge

Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics Sonicator 730 Maintenance manual

Mettler Electronics

Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care R1100 Mounting instruction

Pressalit Care

Pressalit Care R1100 Mounting instruction

Denas MS DENAS-T operating manual

Denas MS

Denas MS DENAS-T operating manual

bort medical ActiveColor quick guide

bort medical

bort medical ActiveColor quick guide

AccuVein AV400 user manual

AccuVein

AccuVein AV400 user manual

agiliti NP Trio user manual

agiliti

agiliti NP Trio user manual

Rocket Medical Rocket Digital Oocyte Aspiration Pump Service manual

Rocket Medical

Rocket Medical Rocket Digital Oocyte Aspiration Pump Service manual

Monteris Medical Neuroblate Instructions for use

Monteris Medical

Monteris Medical Neuroblate Instructions for use

Otto Block 8E33 7 manual

Otto Block

Otto Block 8E33 7 manual

ADVANCED HOME CARE Helios Guide

ADVANCED HOME CARE

ADVANCED HOME CARE Helios Guide

NeuLog NUL-208 Guide

NeuLog

NeuLog NUL-208 Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.