FilterQuick Controller Field Replacement for FilterQuick Models
2
Replacing the Controller
1. Follow the steps in Section 1.4 in the provided manual to record the settings of the replacement
controller on the FilterQuick fryer. Make a note of all settings (include all 20 buttons in
Product Set-up and Vat Set-Up to include System, Time/Date, DST and Filter). They will
have to be transferred to the new service controller.
2. Disconnect the fryer from the electrical power supply.
3. Open the control panel by removing the screws on the bottom of the bezel. Carefully lower the
bezel.
4. Remove the two screws from the upper corners of the controller. The controller is hinged at the
bottom and will swing open from the top.
5. Unplug the wiring harnesses from the connectors on the back of the controller, marking their
position for reassembly. Disconnect the ground wires from the terminals. Remove the controller,
lifting it from the hinged slots.
6. Install the new replacement controller in the far most left position to
setup up the controller.
7. Attach the ground wires and harnesses removed in step 5.
8. Rotate the controller up and install one screw to position it for the
setup sequence.
9. Follow the instructions below to setup the controller to match the settings recorded earlier from the
fryer bank’s leftmost controller.
Setup: FilterQuick Fryers
Left Display Right Display Action
OFF OFF
Press until the controller scrolls Info Mode, changing to Main and then PRODUCT
SETUP.
Product
Setup
Blank Press to scroll to Vat Setup. Press .
Vat setup Enter
code
Enter 1656
system Press .
Language English Press to scroll to another language. Press .
2nd
Language
Spanish Press to scroll to another language. Press .
Locale Non-ce Press to change locale. Press .
Energy gas Press to change to ELEC if necessary. Press .
Type Gl30 full
Press to scroll to GL30 Split (GL…OSP designations are for European usage.) if
necessary. Press .
System
volume
5 Press to change to setting recorded from fryer controller. Press .
Temper
format
F Press to change to setting recorded from fryer controller. Press .
Exit melt
TMPR
180F Press to change to setting recorded from fryer controller. Press .
Ground Wire Terminal
20-Pin Connecto
Ground Wire Terminal
Communication Wires Locator Wire
NOTE:Therightmostcontrollerwillalsohave
anend‐of‐lineresistor.Itmustbetransferred
toanewcontrolleroccupyingtherightmost
position.
Drain Switch
and LED