FS S2800S Series User manual

PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43 65 87 109 1211 1413 1615 2019 2221 2423
1817
SFP
RESET
PWR
S2800S-48T4F
2109
143 65 87 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 49 50 51 52
SFP
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S2800S-24T2F
1 3 5 7 9 11 13 15 17 19 21 23
Link/Act
Link/Act
2PWR 4 6 8 10 12 14 16 18 20 22 RESET
SYS
24
21 43 65 87 109 1211 1413 1615 2019 2221 2423
1817
SFP
25
25
26
26
S2800S-8T2F-P PoE+
1
Green=1000M
PWR SYS
1
PoE
100M
1000M
2345678
9
10
Link/Act
Link/Act RESET
Yellow=10/100M On=Link Flashing=ACT
2 3 4 5 6 7 8 SFP
9 10
S2800S-8T
1 2 3 4 5 6 7 8
RESET
PWR
Green=1000M Yellow=10/100M On=Link Flashing=ACT
SMART MANAGED L2+ BUSINESS SWITCHES
S2800S Series Switches
SMART MANAGED L2+ BUSINESS SWITCHES
SWITCHS D'ENTREPRISE GÉRÉS L2+ INTELLIGENTS
Quick Start Guide V2.0
Quick-Start Anleitung
Guide de Démarrage Rapide

S2800S-8T
1 2 3 4 5 6 7 8
RESET
PWR
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S2800S-8T2F-P PoE+
1
Green=1000M
PWR SYS
1
PoE
100M
1000M
2345678
9
10
Link/Act
Link/Act RESET
Yellow=10/100M On=Link Flashing=ACT
2 3 4 5 6 7 8 SFP
9 10
S2800S-24T2F
1 3 5 7 9 11 13 15 17 19 21 23
Link/Act
Link/Act
2PWR 4 6 8 10 12 14 16 18 20 22 RESET SYS
24
21 43 65 87 109 1211 1413 1615 2019 2221 24231817
SFP
25
25
26
26
RESET
PWR
S2800S-48T4F
2 109
1 43 65 87 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 49 50 51 52
SFP
Green=1000M Yellow=10/100M On=Link Flashing=ACT
PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43 65 87 109 1211 1413 1615 2019 2221 24231817 SFP
Introduction
Accessories
Thank you for choosing S2800S Series Smart Managed Switches. This guide is designed to familiarize
you with the layout of the switch and describes how to deploy the switch in your network.
S2800S-8T
S2800S-8T2F-P
S2800S-24T2F
S2800S-48T4F
S2800S-24T4F-P
S2800S-8T2F-P
Power Cord x1 Grounding Cable x1 Rubber Pad x4
1m Cat5e UTP Ethernet Patch Cable x1Mounting Bracket x2 M3 Screw x6
1
EN

S2800S-24T4F-P/S2800S-24T2F/S2800S-48T4F
S2800S-8T
Power Cord x1 Grounding Cable x1
Grounding Cable x1
Rubber Pad x4
Rubber Pad x4
Mounting Bracket x2 1m Cat5e UTP Ethernet Patch Cable x1
1m Cat5e UTP Ethernet Patch Cable x1
M3 Screw x6
M3 Screw x2
NOTE: S2800S series switches have dust plugs delivered with them. Keep the dust plugs
properly and use them to protect idle optical ports.
Power Adapter x1
Screw Expansion Tube x2
2
EN

Hardware Overview
Front Panel Ports
S2800S-8T2F-P
S2800S-8T
S2800S-24T4F-P
S2800S-8T2F-P PoE+
1
Green=1000M
PWR SYS
1
PoE
100M
1000M
2345678
9
10
Link/Act
Link/Act RESET
Yellow=10/100M On=Link Flashing=ACT
2 3 4 5 6 7 8 SFP
9 10
8x 10/100/1000BASE-T Ports 2x 1G SFP Ports
Ports Description
RJ45
SFP SFP ports for 1G connection
10/100/1000BASE-T ports for Ethernet connection
Ports Description
RJ45 10/100/1000BASE-T ports for Ethernet connection
S2800S-8T
1 2 3 4 5 6 7 8
RESET
PWR
Green=1000M Yellow=10/100M On=Link Flashing=ACT
8x 10/100/1000BASE-T Ports
PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43 65 87 109 1211 1413 1615 2019 2221 24231817 SFP
24x 10/100/1000BASE-T Ports 4x 1G SFP Ports
Ports Description
RJ45
SFP
10/100/1000BASE-T ports for Ethernet connection
SFP ports for 1G connection
3
EN

Front Panel Buttons
S2800S-24T2F
S2800S-8T2F-P PoE+
1
Green=1000M
PWR SYS
1
PoE
100M
1000M
2345678
9
10
Link/Act
Link/Act RESET
Yellow=10/100M On=Link Flashing=ACT
2 3 4 5 6 7 8 SFP
9 10
S2800S-8T
1 2 3 4 5 6 7 8
RESET
PWR
Green=1000M Yellow=10/100M On=Link Flashing=ACT
Ports Description
RJ45
SFP
10/100/1000BASE-T ports for Ethernet connection
SFP ports for 1G connection
S2800S-48T4F
S2800S-8T2F-P
S2800S-8T
Ports Description
RJ45
SFP
10/100/1000BASE-T ports for Ethernet connection
SFP ports for 1G connection
RESET
PWR
S2800S-48T4F
2 109
1 43 65 87 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 49 50 51 52
SFP
Green=1000M Yellow=10/100M On=Link Flashing=ACT
48x 10/100/1000BASE-T Ports
RESET
4x 1G SFP Ports
S2800S-24T2F
1 3 5 7 9 11 13 15 17 19 21 23
Link/Act
Link/Act
2PWR 4 6 8 10 12 14 16 18 20 22 RESET SYS
24
21 43 65 87 109 1211 1413 1615 2019 2221 24231817
SFP
25
25
26
26
24x 10/100/1000BASE-T Ports 2x 1G SFP Ports
RESET
4
EN

12V 1A SWITCH GND
PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43 65 87 109 1211 1413 1615 2019 2221 24231817 SFP
S2800S-24T4F-P
S2800S-24T2F
S2800S-48T4F
RESET
PWR
S2800S-48T4F
2 109
1 43 65 87 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 49 50 51 52
SFP
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S2800S-24T2F
1 3 5 7 9 11 13 15 17 19 21 23
Link/Act
Link/Act
2PWR 4 6 8 10 12 14 16 18 20 22 RESET SYS
24
21 43 65 87 109 1211 1413 1615 2019 2221 24231817
SFP
25
25
26
26
RESET
RESET
RESET
Back Panels
S2800S-8T2F-P
S2800S-8T
100-240V~, 50-60Hz.2A
Grounding Point Power Supply
Single Power Supply Power ON/OFF Grounding Point Kensington Security Slot
Button Description
Restart: Press and hold the RESET button for more than ve
seconds, and then wait for ve seconds.
RESET
5
EN

S2800S-24T4F-P
Single Power Supply Grounding Point
IN:100-240V AC 50-60Hz
Front Panel LEDs
S2800S-8T2F-P PoE+
1
Green=1000M
PWR SYS
1
PoE
100M
1000M
2345678
9
10
Link/Act
Link/Act RESET
Yellow=10/100M On=Link Flashing=ACT
2 3 4 5 6 7 8 SFP
9 10
S2800S-8T
1 2 3 4 5 6 7 8
RESET
PWR
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S2800S-8T2F-P
S2800S-8T
PWR
PoE
SYS 100M Link/Act
1000M Link/Act
PWR
1000M Link/Act
100M Link/Act
S2800S-48T4F
S2800S-24T2F
100-240V,50-60Hz.0.08A
Grounding Point Single Power Supply
IN:100-240V AC 50-60Hz
Single Power Supply Grounding Point
6
EN

S2800S-24T4F-P
PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43 65 87 109 1211 1413 1615 2019 2221 24231817 SFP
PWR
SYS PoE Link/Act
RESET
PWR
S2800S-48T4F
2 109
1 43 65 87 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 49 50 51 52
SFP
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S2800S-24T2F
1 3 5 7 9 11 13 15 17 19 21 23
Link/Act
Link/Act
2PWR 4 6 8 10 12 14 16 18 20 22 RESET SYS
24
21 43 65 87 109 1211 1413 1615 2019 2221 24231817
SFP
25
25
26
26
PWR Link/Act SYS
RJ45
PWR
SFP
SFP
S2800S-24T2F
S2800S-48T4F
PWR
SYSTEM
The power supply is operational.Solid Green
Blinking Green
O
O
Solid Green
Switch is not receiving power.
The system is working properly.
The system is not working properly.
The system is not working properly.
RJ45
PoE
SFP
O
O
Solid Green
Blinking Green
Solid Yellow
Blinking Yellow
Solid Green
The port is not connected.
The port is connected at 1000 Mbps.
The port is receiving or transmitting trac at 1000 Mbps.
The port is connected at 10/100 Mbps.
The port is receiving or transmitting trac at 10/100 Mbps.
PoE is not enabled.
PoE is enabled. The port is operational.
O The port is not connected.
Solid Green The port is connected at 1000 Mbps.
Blinking Green The port is receiving or transmitting trac at 1000 Mbps.
LEDs Status Description
7
EN

PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43 65 87 109 1211 1413 1615 17
Installation Requirements
Before you begin the installation, make sure that you have the following:
The installation site must be well ventilated. Ensure that there is adequate airow around the
switch.
Site Environment:
Do not operate it in an area that exceeds an ambient temperature of 50°C.
Phillips screwdriver.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables, ber optical cables , and console cable for
connecting network devices.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Ensure rack and working platforms are well earthed.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Do not install the equipment in a dusty environment.
8
EN

PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43
2019 2221 2423
1817
SFP
Mounting the Switch
Desk Mounting
Rack Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on a desk.
1. Secure the mounting brackets to the two sides of the switch with supplied M3 screws.
PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43 65 87 109 1211 1413 1615 2019 2221 2423
1817
SFP
9
EN

IN:100-240V AC 50-60Hz
4 65 87 109 1211 1413 1615 2019 2221 2423
1817
SFP
Grounding the Switch
2. Attach the switch to the rack using four M6 screws and cage nuts.
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch back panel with the washers and
screws.
CAUTION: The earth connection must not be removed unless all supply connections have
been disconnected.
10
EN

PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43 65 87 109 1211 1413 1615 2019 2221 2423
1817
IN:100-240V AC 50-60Hz
Connecting the Power
Connecting the RJ45 Ports
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to an AC power source.
1. Connect an Ethernet cable to the RJ45 port of IP cameras, IP telephone, Access Points (AP), or other
network devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.
WARNING: Do not install power cable while the power is on.
PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43 65 87 9
EN
11

24
SFP
Connecting the SFP Ports
1. Plug the compatible SFP transceiver into the SFP port.
2. Connect a ber optic cable to the ber transceiver. Then connect the other end of the cable to
another ber device.
109 1211 1413 1615 2019 2221 2423
1817
SFP
Conguring the Switch Using the Web-based Interface
Conguring the Switch
Step 1: Connect the computer to any RJ45 port of the switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x. (“x” is any number from 2 to 254.)
?x
OK Cancel
General
IP address:
Subnet ma sk :
Default ga t ew a y :
You can get IP settings assigned automatically if your network
supports this capability. Otherwise, you need to ask your network
administrator for the appropriate IP settings.
Internet Protocol Version 4 (TCP/IPv4) Properties
Use the following IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit A d v anc e d ...
. . .21168192
0255
255255
. . .
. . .
. . .
. . .
ObtainDNSserv er addressa utomatically
Use the following DNS se rver addresses:
EN
12

Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password,
admin/admin.
Step 4: Click Login to display the web-based conguration page.
1G Port is not Working
Troubleshooting
In the case of compatible cables and transceivers, the port cannot be up, please try to modify the port
mode to adapt or force the port speed to 1G.
Connecting the Switch Remotely Unsuccessfully
1. Test network connectivity through ping.
2. If the network is reachable, try restarting the switch.
3. Check if the corresponding service is enabled.
The Port is not Working, the LED Indicator is O
1. Ensure the switch ports are in the no shutdown state.
2. Check if the switch can read the DDM information.
3. Check if the port speed setting is correct.
4. Try looping the switch cable.
admin
English
Login
Remember Password
……
13
EN

RJ45 port is not in connectivity or it is erroneous in receiving/transmitting
frames
1. Replace the twisted pair cable.
2. Check that the port conguration has the common working mode with the connected switch.
Support and Other Resources
Download
Help Center
Contact Us
https://www.fs.com/download.html
https://www.fs.com/service/help_center.html
https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will oer a
free return within 30 Days from the day you receive your goods. This excludes any custom made
items or tailored solutions.
Warranty: S2800S series switches enjoy 1 Year limited warranty against defect in materials
or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
1
14
EN

S2800S-8T
1 2 3 4 5 6 7 8
RESET
PWR
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S2800S-8T2F-P PoE+
1
Green=1000M
PWR SYS
1
PoE
100M
1000M
2345678
9
10
Link/Act
Link/Act RESET
Yellow=10/100M On=Link Flashing=ACT
2 3 4 5 6 7 8 SFP
9 10
S2800S-24T2F
1 3 5 7 9 11 13 15 17 19 21 23
Link/Act
Link/Act
2PWR 4 6 8 10 12 14 16 18 20 22 RESET SYS
24
21 43 65 87 109 1211 1413 1615 2019 2221 24231817
SFP
25
25
26
26
RESET
PWR
S2800S-48T4F
2 109
1 43 65 87 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 49 50 51 52
SFP
Green=1000M Yellow=10/100M On=Link Flashing=ACT
PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43 65 87 109 1211 1413 1615 2019 2221 24231817 SFP
Einführung
Zubehör
Vielen Dank, dass Sie sich für Smart Managed Switches der S2800S-Serie entschieden haben.
Diese Anleitung soll Sie mit dem Aufbau des Switches vertraut machen und beschreibt, wie Sie den
Switch in Ihrem Netzwerk einsetzen.
S2800S-8T
S2800S-8T2F-P
S2800S-24T2F
S2800S-48T4F
S2800S-24T4F-P
S2800S-8T2F-P
Netzkabel x1 Erdungskabel x1 Gummipad x4
1m Cat5e UTP-Ethernet-Patchkabel x1Montagehalterung x2 M3-Schraube x6
15
DE

S2800S-24T4F-P/S2800S-24T2F/S2800S-48T4F
S2800S-8T
Netzkabel x1 Erdungskabel x1
Erdungskabel x1
Gummipad x4
Gummipad x4
Montagehalterung x2 1m Cat5e UTP-Ethernet-Patchkabel x1
1m Cat5e UTP-Ethernet-Patchkabel x1
M3-Schraube x6
M3-Schraube x2
HINWEIS: Die Switches der Serie S2800S werden mit Staubschutzstopfen geliefert.
Bewahren Sie die Staubschutzstopfen ordnungsgemäß auf und verwenden Sie sie zum
Schutz der ungenutzten optischen Anschlüsse.
Netzkabel x1
Schraube Expansionsrohr x2
16
DE

Hardware-Übersicht
Ports an der Vorderseite
S2800S-8T2F-P
S2800S-8T
S2800S-24T4F-P
S2800S-8T2F-P PoE+
1
Green=1000M
PWR SYS
1
PoE
100M
1000M
2345678
9
10
Link/Act
Link/Act RESET
Yellow=10/100M On=Link Flashing=ACT
2 3 4 5 6 7 8 SFP
9 10
8x 10/100/1000BASE-T Ports 2x 1G SFP Ports
Ports Beschreibung
RJ45
SFP SFP-Ports für 1G-Verbindung
10/100/1000BASE-T-Ports für Ethernet-Anschluss
Ports Beschreibung
RJ45 10/100/1000BASE-T-Ports für Ethernet-Anschluss
S2800S-8T
1 2 3 4 5 6 7 8
RESET
PWR
Green=1000M Yellow=10/100M On=Link Flashing=ACT
8x 10/100/1000BASE-T Ports
PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43 65 87 109 1211 1413 1615 2019 2221 24231817 SFP
24x 10/100/1000BASE-T Ports 4x 1G SFP Ports
Ports Beschreibung
RJ45
SFP
10/100/1000BASE-T-Ports für Ethernet-Anschluss
SFP-Ports für 1G-Verbindung
17
DE

Tasten an der Vorderseite
S2800S-24T2F
S2800S-8T2F-P PoE+
1
Green=1000M
PWR SYS
1
PoE
100M
1000M
2345678
9
10
Link/Act
Link/Act RESET
Yellow=10/100M On=Link Flashing=ACT
2 3 4 5 6 7 8 SFP
9 10
S2800S-8T
1 2 3 4 5 6 7 8
RESET
PWR
Green=1000M Yellow=10/100M On=Link Flashing=ACT
Ports Beschreibung
RJ45
SFP
10/100/1000BASE-T-Ports für Ethernet-Anschluss
SFP-Ports für 1G-Verbindung
S2800S-48T4F
S2800S-8T2F-P
S2800S-8T
Ports Beschreibung
RJ45
SFP
10/100/1000BASE-T-Ports für Ethernet-Anschluss
SFP-Ports für 1G-Verbindung
RESET
PWR
S2800S-48T4F
2 109
1 43 65 87 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 49 50 51 52
SFP
Green=1000M Yellow=10/100M On=Link Flashing=ACT
48x 10/100/1000BASE-T Ports
RESET
4x 1G SFP Ports
S2800S-24T2F
1 3 5 7 9 11 13 15 17 19 21 23
Link/Act
Link/Act
2PWR 4 6 8 10 12 14 16 18 20 22 RESET SYS
24
21 43 65 87 109 1211 1413 1615 2019 2221 24231817
SFP
25
25
26
26
24x 10/100/1000BASE-T Ports 2x 1G SFP Ports
RESET
18
DE

12V 1A SWITCH GND
PWR SYS
1
2 4 6 8 10 12 14 16 18 20 22 24 26
PoE
28
2 5 7 9 11 13 15 17 19 21 23 25 27
Link/Act
Link/Act
RESET
S2800S-24T4F-P PoE+
21 43 65 87 109 1211 1413 1615 2019 2221 24231817 SFP
S2800S-24T4F-P
S2800S-24T2F
S2800S-48T4F
RESET
PWR
S2800S-48T4F
2 109
1 43 65 87 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 49 50 51 52
SFP
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S2800S-24T2F
1 3 5 7 9 11 13 15 17 19 21 23
Link/Act
Link/Act
2PWR 4 6 8 10 12 14 16 18 20 22 RESET SYS
24
21 43 65 87 109 1211 1413 1615 2019 2221 24231817
SFP
25
25
26
26
RESET
RESET
RESET
Rückseite
S2800S-8T2F-P
S2800S-8T
100-240V~, 50-60Hz.2A
Erdungspunkt Stromversorgung
Einzelne Stromversorgung Strom EIN/AUS Erdungspunkt Kensington-Schloss
Taste Beschreibung
Neustart: Halten Sie die RESET-Taste länger als fünf Sekunden
gedrückt und warten Sie dann fünf Sekunden lang.
RESET
19
DE
This manual suits for next models
5
Table of contents
Languages:
Other FS Switch manuals

FS
FS S3400-24T4SP User manual

FS
FS S3900 Series User manual

FS
FS PoE+ Series User manual

FS
FS S5810 Series Operating manual

FS
FS S3150-8T2FP User manual

FS
FS S5860-24XB-U User manual

FS
FS S3150-8T2FP User manual

FS
FS IES3100-8T4F-P User manual

FS
FS S3270 Series Operating manual

FS
FS S3700-24T4F Instruction Manual