FS S5810 Series User manual

MINICONSOLE
PoE
PoE
STATUSPWR1 PWR2 MGMT
5049 5251
SFP+
S5810-48TS-P PoE+
On=Link Flashing=ACT Green=1000M Yellow=10/100M
CONSOLE
MGMT
2
14
36
58
710
912
11 14
13 16 32
15 18
17 20
19 22
21 24
23 26
25 28
27 30
29 31 48
34
33 36
35 38
37 40
39 42
41 44
43 46
45 47
MINICONSOLE
STATUSPWR1 PWR2MGMT
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
S5810-48FS
On=Link Flashing=ACT Green=1000M Yellow=100M
MGMT
CONSOLE
MINICONSOLE
STATUSPWR1 PWR2MGMT
S5810-28FS
SFP+
COMBO
21 43 65 87 21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE
MANAGED L2/L3 ENTERPRISE SWITCHES
S5810 Series Switches
Quick Start Guide V1.0

MINICONSOLE
PoE
PoE
STATUSPWR1 PWR2 MGMT
5049 5251
SFP+
S5810-48TS-P PoE+
On=Link Flashing=ACT Green=1000M Yellow=10/100M
CONSOLE
MGMT
2
14
36
58
710
912
11 14
13 16 32
15 18
17 20
19 22
21 24
23 26
25 28
27 30
29 31 48
34
33 36
35 38
37 40
39 42
41 44
43 46
45 47
MINICONSOLE
STATUSPWR1 PWR2 MGMT
S5810-28FS
SFP+
COMBO
21 43 65 87 21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE
MINICONSOLE
STATUSPWR1 PWR2 MGMT
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
S5810-48FS
On=Link Flashing=ACT Green=1000M Yellow=100M
MGMT
CONSOLE
Introduction
Thank you for choosing S5810 Series Switches. This guide is designed to familiarize you with the
layout of the switch and describes how to deploy the switch in your network.
S5810-28FS
S5810-48FS
S5810-48TS-P
Accessories
S5810-28FS/S5810-48FS/S5810-48TS-P
Power Cord x2
Mounting Bracket x2 M4 Screw x8
Rubber Pad x4
Grounding Cable x1
NOTE: S5810 series switches have dust plugs delivered with them. Keep the dust plugs
properly and use them to protect idle optical ports.
Mini Console Cable x1

Hardware Overview
Front Panel Ports
Ports Description
RJ45
COMBO
SFP
10/100/1000BASE-T ports for Ethernet connection
One RJ45 port and one SFP slot, with one port active at a time
SFP ports for 100M/1G connection
SFP+ SFP+ ports for 1/10G connection
S5810-28FS
S5810-48FS
S5810-48TS-P
MINI CONSOLE
STATUSPWR1 PWR2 MGMT
S5810-28FS
SFP+
COMBO
21 43 65 87 21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE
MINI CONSOLE
USB MGMT COMBO SFP SFP+
CONSOLE
SFP
MINI CONSOLE
STATUSPWR1 PWR2 MGMT
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
S5810-48FS
On=Link Flashing=ACT Green=1000M Yellow=100M
MGMT
CONSOLE
MINI CONSOLE CONSOLE
USB MGMT SFP+
MINI CONSOLE
PoE
PoE
STATUSPWR1 PWR2 MGMT
5049 5251
SFP+
S5810-48TS-P PoE+
On=Link Flashing=ACT Green=1000M Yellow=10/100M
CONSOLE
MGMT
2
14
36
58
710
912
11 14
13 16 32
15 18
17 20
19 22
21 24
23 26
25 28
27 30
29 31 48
34
33 36
35 38
37 40
39 42
41 44
43 46
45 47
MINI CONSOLE CONSOLE
USB MGMT
RJ45
SFP+
MGMT An out-of-band Ethernet management port
MINI CONSOLE A serial port for installing the software driver

PWR1 PWR2
Module1
Module2
Ports Description
Front Panel Button
Back Panels
S5810-48TS-P
S5810-28FS
S5810-48FS
MINI CONSOLE
PoE
PoE
STATUSPWR1 PWR2 MGMT
5049 5251
SFP+
S5810-48TS-P PoE+
On=Link Flashing=ACT Green=1000M Yellow=10/100M
CONSOLE
MGMT
2
14
36
58
710
912
11 14
13 16 32
15 18
17 20
19 22
21 24
23 26
25 28
27 30
29 31 48
34
33 36
35 38
37 40
39 42
41 44
43 46
45 47
PoE
CONSOLE An RJ45 console port for serial management
USB A USB management port for software and conguration backup and oine
software upgrade
Button Description
PoE Switch the display mode between PoE mode and switch mode.
Grounding Point Expansion Module Slot
Expansion Module Slot
Dual Power Supplies
Grounding Point Dual Power Supplies
PWR1 PWR2
Module1 Module2

MINI CONSOLE
PoE
PoE
STATUSPWR1 PWR2 MGMT
5049 5251
SFP+
S5810-48TS-P PoE+
On=Link Flashing=ACT Green=1000M Yellow=10/100M
CONSOLE
MGMT
2
14
36
58
710
912
11 14
13 16 32
15 18
17 20
19 22
21 24
23 26
25 28
27 30
29 31 48
34
33 36
35 38
37 40
39 42
41 44
43 46
45 47
Front Panel LEDs
S5810-28FS
S5810-48FS
S5810-48TS-P
MINI CONSOLE
STATUSPWR1 PWR2 MGMT
S5810-28FS
SFP+
COMBO
21 43 65 87 21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE
STATUS
PWR1 MGMT RJ45 SFP SFP+
PWR2
S5810-48TS-P
PWR2PWR1
Input
Output
Input
Output
Grounding Point
Dual Power Supplies
SFP
MINI CONSOLE
STATUSPWR1 PWR2 MGMT
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
S5810-48FS
On=Link Flashing=ACT Green=1000M Yellow=100M
MGMT
CONSOLE
PWR1 MGMT SFP+
STATUS
PWR2
PWR1MGMT PoE (1-48) SFP+
STATUS PoE RJ45
PWR2

LEDs Status Description
O
Blinking Green (3Hz)
The system is powered o.
Solid Green The switch is operational.
The switch is being initialized with 3Hz blinking.
Continuous blinking indicates errors.
Blinking Green (10Hz) Supports remote on/o to locate the switch.
STATUS
PWR1/PWR2
MGMT
PoE
Solid Yellow Temperature warning, check the working environment of
the switch immediately.
Solid Red Switch is faulty.
O The power module is not in place or not receiving power.
Solid Green The power module is connected and able to work.
Solid Red The redundant power is faulty or the AC power cord is not
connected.
O The port is not connected.
Solid Green The port is connected at 1000 Mbps.
Blinking Green The port is receiving or transmitting trac at 1000 Mbps.
Solid Yellow The port is connected at 10/100 Mbps.
Blinking Yellow The port is receiving or transmitting trac at 10/100 Mbps.
Solid Green Indicates the switching state.
Solid Yellow Indicates the PoE state.
RJ45
O The port is not connected.
Solid Green The port is connected at 1000 Mbps.
Blinking Green The port is receiving or transmitting trac at 1000 Mbps.
Solid Yellow The port is connected at 10/100 Mbps.
Blinking Yellow
The port is receiving or transmitting trac at 10/100 Mbps.

LEDs Status Description
PoE (1-48)
SFP
O The port is not connected.
Solid Green The port is connected at 1000 Mbps.
Blinking Green The port is receiving or transmitting trac at 1000 Mbps.
Solid Yellow The port is connected at 100 Mbps.
Blinking Yellow The port is receiving or transmitting trac at 100 Mbps.
The port is not connected.
The port is connected at 1/10 Gbps.
The port is receiving or transmitting trac at 1/10 Gbps.
SFP+
O
Solid Green
Blinking Green
O PoE is not enabled.
Solid Green PoE is enabled. The port is operational.
Solid Yellow The port has a PoE fault of overload.

Installation Requirements
Before you begin the installation, make sure that you have the followings:
Phillips screwdriver.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables, ber optical cables and console cable for connecting
network devices.
Site Environment:
Do not operate it in an area that exceeds an ambient temperature of 50°C.
Do not install the equipment in a dusty environment.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
The installation site must be well ventilated. Ensure that there is adequate airow around the
switch.
The switch should be installed at least 1U (44.45mm) away from devices to its sides.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Ensure rack and working platforms are well earthed.
MINI CONSOLE
STATUSPWR1 PWR2 MGMT
COMBO
21 43 65 87 21 43 65 87 109 1211 1413 1615 17
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE

Mounting the Switch
Desk Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on a desk.
1. Secure the mounting brackets to the two sides of the switch with eight M4 screws.
Rack Mounting
S5810-28FS
SFP+
20 2221 2423 2625 2827 3029 3231
Module1
MINI CONSOLE
STATUSPWR1 PWR2 MGMT
COMBO
21 43 65 87 21 3
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE

PWR1 PWR2
Module2
PWR1
S5810-28FS
SFP+
87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231
NOTE: Insert the power module steadily. Please pay attention to the direction of the
power panel to avoid wrong insertion. If the position is not proper, press the plug of the
power module and hold on to the module handle with one hand to pull it out slowly, then
re-insert it.
Installing the Power Supply Module
2. Attach the switch to the rack using four M6 screws and cage nuts.
1. Take a new power module out of the package and conrm the input mode and the input parameters
of the power module match the requirements.
2. Remove the old power module and take the plane printed with power information as the top panel
of the power module. Hold the handle of the power module with one hand, and hold the end of the
power module with the other hand. Insert it into the chassis along the guide rail uprightly and slowly
until it clicks into place, and make sure that it is in good contact with the power slot.

PWR1 PWR2
Module2
PWR1
Module1
Module2
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch back panel with the washers and
screws.
Grounding the Switch
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to an AC power source.
Connecting the Power
WARNING: Do not install power cable while the power is on.
CAUTION: The earth connection must not be removed unless all supply connections have
been disconnected.

PWR2
WARNING: Laser beams will cause eye damage. Do not look into bores of optical modules
or optical bers without eye protection.
Connecting the RJ45 Ports
1. Connect an Ethernet cable to the RJ45 port of IP cameras, IP telephone, Access Points (AP), or other
network devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.
1. Plug the compatible SFP/SFP+ transceiver into the SFP/SFP+ port.
2. Connect a ber optic cable to the ber transceiver. Then connect the other end of the cable to
another ber device.
Connecting the SFP/SFP+ Ports
MINI CONSOLE
STATUSPWR1 PWR2 MGMT
SFP+
COMBO
21 43 65 87 21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 31
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE

S5810-28FS
MINI CONSOLE
STATUSPWR1 PWR2 MGMT
COMBO
21 43 65 87 21 43 65 87 109 1211 1413
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE
1. Insert the RJ45 connector into the RJ45 console port on the front of the switch.
2. Connect the DB9 female connector of the console cable to the serial port on the computer.
Connecting the Console Port
1. Connect one end of a standard RJ45 Ethernet cable to a computer.
2. Connect the other end of the cable to the MGMT port on the front of the switch.
Connecting the MGMT Port
MINI CONSOLE
STATUSPWR1 PWR2 MGMT
COMBO
21 43 65 87 21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 29
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE

S5810-28FS
SFP+
18 2019 2221 2423 2625 2827 3029 3231
S5810-28FS
MINICONSOLE
STATUSPWR1 PWR2 MGMT
S5810-28FS
SFP+
COMBO
21 43 65 87 21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE
MINICONSOLE
STATUSPWR1 PWR2 MGMT
S5810-28FS
SFP+
COMBO
21 43 65 87 21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE
MINICONSOLE
STATUSPWR1 PWR2 MGMT
S5810-28FS
SFP+
COMBO
21 43 65 87 21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE
MINICONSOLE
STATUSPWR1 PWR2 MGMT
S5810-28FS
SFP+
COMBO
21 43 65 87 21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231
On=Link Flashing=ACT Green=1000M Yellow=10/100M
MGMT
CONSOLE
Stacking the Switches
The S5810 series switches support stacking up to 8 switches between the same series together.
The switch can be physically stacked using optical ber cables connected to SFP/SFP+ transceivers or
1G/10G Direct Attach Cables (DAC). Only four SFP+ uplinks on the switch can be used for physical
stacking.

Step 4: Click Login to display the web-based conguration page.
Conguring the Switch
Step 1: Connect the computer to the Management port of the switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x.(“x” is any number from 2 to 254.)
Conguring the Switch Using the Web-based Interface
?x
OK Cancel
General
IP address:
Subnet mask:
Default gateway:
You can get IP settings assigned automatically if your network
supports this capability. Otherwise, you need to ask your network
administrator for the appropriate IP settings.
Internet Protocol Version 4(TCP/IPv4) Properties
Use the following IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit Advanced...
. . . 21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNS server address automatically
Use the following DNS server addresses:
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password,
admin/admin.
IE 8/9/10/11, Google Chrome, Firefox are supported
Login
admin
*****

Conguring the Switch Using the Console Port
Step 1: Connect a computer to the switch's console port using the console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 9600 bits per second, 8 data bits, no parity, 1 stop bit
and no ow control.
Step 4: After setting the parameters, click Connect to enter.
x
Quick Connect
Protocol:
The port may be manually entered or selected from the list.
Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect
Cancel
COM3
9600
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:

Troubleshooting
The indicator on the front panel of host is OFF. The Status indicator of fan module is OFF, and the fan
does not work. The indicator on the panel of the power module is OFF and the fan does not work.
Please check the following:
After power-on, if the conguration terminal shows nothing, you can rstly check the following:
1. Whether serial port cables are connected correctly.
2. Whether the conguration of the serial port on the HyperTerminal.
First, disconnect the power cord of the power module.
1. Whether the cables of the cabinet have been correctly connected.
2. Whether the cabinet power sockets are loosely connected to power modules.
3. Whether the power modules are installed correctly.
1. Test network connectivity through ping.
2. If the network is reachable, try restarting the switch.
3. Check if the corresponding service is enabled.
1. Ensure the switch ports are in the no shutdown state.
2. Check if the switch can read the DDM information.
3. Check if the port speed setting is correct.
4. Try looping the switch cable.
Power System Fault
Connecting the Switch Remotely Unsuccessfully
The Port is not Working, the LED Indicator is O
Troubleshooting for Terminal No-show
If the conguration terminal shows error codes, it is likely that the terminal (such as HyperTerminal)
parameters are set incorrectly. Please conrm the parameters of the terminal (such as HyperTerminal).
Troubleshooting for Terminal Show Error Codes

Support and Other Resources
Download
Help Center
Contact Us
https://www.fs.com/download.html
https://www.fs.com/service/help_center.html
https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will oer a
free return within 30 Days from the day you receive your goods. This excludes any custom made
items or tailored solutions.
Warranty: S5810 series switches enjoy 5 years limited warranty against defect in materials
or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
5
Copyright © 2020 FS.COM All Rights Reserved.
Q.C. PASSED
Other manuals for S5810 Series
2
This manual suits for next models
6
Table of contents
Other FS Switch manuals

FS
FS S5860-20SQ User manual

FS
FS S5850-48S8C User manual

FS
FS T5850 Series User manual

FS
FS PoE+ Series User manual

FS
FS IES3110 Series User manual

FS
FS S3410 Series User manual

FS
FS PoE+ Series Operating instructions

FS
FS S1900-16T User manual

FS
FS S5850-24XMG-U Series User manual

FS
FS S1900-24T User manual