FS S3150-8T2FP User manual

8/16/24/48PORT GIGABIT L2+ POE+
MANAGED SWITCH
PoE+ Series Switches
Quick Start Guide V2.0
CONSOLE
SFP+
TE1
RESET
POE
PoE
S3400-48T4SP
31 2 5 7 9 11 13 15 17 19 21 23 25 27
4 6 8 10 12 14 16 18 20 22 24 26 28
SYS
PWR
29 31 33 35 37 39 41 43
30 32 34 36 38 40 42 44 45 4746 48
TE2TE3TE4
SYS 2 4 6 8 10 12 14 16 18 18F 20
1 3 5 7 9 11 13 15 17 17F 19
Lnk/Act
Lnk/Act
PoE
PoE RESET
PWR
CONSOLE
17
17F 18F 19 20
18
1 3 5 7
2 4 6 8
911 13 15
10 12 14 16
S3260-16T4FP
PoE
13 5 7 9 11
2468 10 12
13 15 17 19 21 23
14 16 18 20 22 24 26 26F
25
28
27
COMBO
25F
28F
CONSOLE
PoE
27F
S3400-24T4FP
PoE
SYS 31
2
57 9 11 13 15 17 19 21 23 25 27 25F27F
PWR 468 10 12 14 16 18 20 22 24 26 28 26F28F
LnK/Act
PoE RESET
LnK/Act
1 3 5 7
24 6 8
10
PoE
SYS
S3260-8T2FP
31
2
579
PWR 4 6 8
LnK/Act
PoE
+
EO
P
RESET
LnK/Act
9 10
SFP
CONSOLE
PoE
1357
2 4 6 8
10
PoE
SYS
S3150-8T2FP
31
2
5 7 9
PWR 4 6 8
LnK/Act
PoE
+
E
O
P
RESET
LnK/Act
9 10
SFP
CONSOLE
PoE
COMBO

Introduction
Thank you for choosing PoE+ Series Switches. This guide is designed to familiarize you with the layout
of the switches and describes how to deploy the switches in your network.
Accessories
Power Cable x1 Rack Mount Bracket x2
M3 Screw x8Rubber Pad x4
Console Cable x1
S3260-8T2FP
S3260-16T4FP
S3400-24T4FP
S3150-8T2FP
S3400-48T4SP
CONSOLE
SFP+
TE1
RESET
POE
PoE
S3400-48T4SP
3
1 2 5 7 9 11 13 15 17 19 21 23 25 27
4 6 8 10 12 14 16 18 20 22 24 26 28
SYS
PWR
29 31 33 35 37 39 41 43
30 32 34 36 38 40 42 44 45 47
46 48
TE2TE3TE4
CONSOLE
SFP+
TE1
RESET
POE
PoE
S3400-48T4SP
3
1 2 5 7 9 11 13 15 17 19 21 23 25 27
4 6 8 10 12 14 16 18 20 22 24 26 28
SYS
PWR
29 31 33 35 37 39 41 43
30 32 34 36 38 40 42 44 45 47
46 48
TE2TE3TE4
1 3 5 7 9 11
2 4 6 8 10 12
13 15 17 19 21 23
14 16 18 20 22 24 26 26F
25
28
27
COMBO
25F
28F
CONSOLE
PoE
27F
1 3 5 7
24 6 8
10
PoE
SYS
S3260-8T2FP
31
2
5 7 9
PWR 468
LnK/Act
PoE
+EO
P
RESET
LnK/Act
9 10
SFP
CONSOLE
PoE
1 3 5 7
2 4 6 8
10
PoE
SYS
S3150-8T2FP
31
2
5 7 9
PWR 4 6 8
LnK/Act
PoE
+EOP
RESET
LnK/Act
910
SFP
CONSOLE
PoE
SYS 2 4 6 8 10 12 14 16 18 18F 20
1 3 5 7 9 11 13 15 17 17F 19
Lnk/Act
Lnk/Act
PoE
PoE RESET
PWR
CONSOLE
17
17F 18F 19 20
18
1 3 5 7
2468
9 11 13 15
10 12 14 16
S3260-16T4FP
PoE
S3400-24T4FP
PoE
SYS 31
2
5 7 9 11 13 15 17 19 21 23 25 27 25F 27F
PWR 4 6 8 10 12 14 16 18 20 22 24 26 28 26F 28F
LnK/Act
PoE RESET
LnK/Act
COMBO

Hardware Overview
Front Panel Ports
1 3 5 7 9 11
2 4 6 8 10 12
13 15 17 19 21 23
14 16 18 20 22 24 26 26F
25
28
27 25F
28F
CONSOLE
PoE
27F
S3400-24T4FP
PoE
SYS 31
2
57911 13 15 17 19 21 23 25 27 25F 27F
PWR 46810 12 14 16 18 20 22 24 26 28 26F 28F
LnK/Act
PoE RESET
LnK/Act
COMBO
RJ45 RJ45/SFP Combo Console
S3400-24T4FP
1357
2468
10
PoE
SYS 31
2
5 7 9
PWR 4 6 8
LnK/Act
PoE
+EOP
RESET
LnK/Act
910
SFP
CONSOLE
PoE
RJ45 SFP Console
S3150-8T2FP/S3260-8T2FP
S3260-16T4FP
SYS 2 4 6 8 10 12 14 16 18 18F 20
1 3 5 7 9 11 13 15 17 17F 19
Lnk/Act
Lnk/Act
PoE
PoE RESET
PWR
CONSOLE
17
17F 18F 19 20
18
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
S3260-16T4FP
PoE
COMBO
Console RJ45 RJ45/SFP Combo SFP
Ports Description
RJ45
RJ45/SFP Combo
SFP
10/100/1000BASE-T ports for Ethernet connection
One RJ45 port and one SFP slot, with one port active at a time
SFP ports for 1G transceivers
SFP+ SFP+ ports for 10G transceivers
Console An RJ45 console port for serial management
S3400-48T4SP
CONSOLE
SFP+
TE1
RESET
POE
PoE
S3400-48T4SP
3
1 2 5 7 9 11 13 15 17 19 21 23 25 27
4 6 8 10 12 14 16 18 20 22 24 26 28
SYS
PWR
29 31 33 35 37 39 41 43
30 32 34 36 38 40 42 44 45 47
46 48
TE2TE3TE4
CONSOLE
SFP+
TE1
RESET
POE
PoE
S3400-48T4SP
3
1 2 5 7 9 11 13 15 17 19 21 23 25 27
4 6 8 10 12 14 16 18 20 22 24 26 28
SYS
PWR
29 31 33 35 37 39 41 43
30 32 34 36 38 40 42 44 45 47
46 48
TE2TE3TE4
RJ45 SFP+ Console

1 3 5 7 9 11
2 4 6 8 10 12
13 15 17 19 21 23
14 16 18 20 22 24 26 26F
25
28
27 25F
28F
CONSOLE
PoE
27F
S3400-24T4FP
PoE
SYS 31
2
57911 13 15 17 19 21 23 25 27 25F 27F
PWR 46810 12 14 16 18 20 22 24 26 28 26F 28F
LnK/Act
PoE RESET
LnK/Act
COMBO
Front Panel Button
RESET
Button Description
Reset Restart and restore factory default settings.
LEDs Status Description
SYS
PWR
Lnk/Act
Switch is powered on.
System is working properly.
System is working not properly.
Data is being transmitted or received.
PoE
Connection is not connected.
ON
Blinking Green
ON/OFF
Blinking Green
Connected PD device, working properly.
ON/OFF
ON
Front Panel LEDs
1 3 5 7 9 11
2 4 6 8 10 12
13 15 17 19 21 23
14 16 18 20 22 24 26 26F
25
28
27 25F
28F
CONSOLE
PoE
27F
S3400-24T4FP
PoE
SYS 31
2
57911 13 15 17 19 21 23 25 27 25F 27F
PWR 46810 12 14 16 18 20 22 24 26 28 26F 28F
LnK/Act
PoE RESET
LnK/Act
Lnk/Act
PWR PoE
SYS
COMBO

Installation Requirements
Do not operate it in an area that exceeds an ambient temperature of 50ºC.
The installation site must be well ventilated. Ensure that there is adequate air fow around the
switch.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Do not install the equipment in a dusty environment.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Ensure rack and working platforms are well earthed.
Phillips screwdriver.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ45 Ethernet cables for connecting the network devices.
Back Panel
POWER
Input:100-240Vac
Freq:50/60Hz
ON
OFF
Input:53.5Vdc
Grounding PointPower Supply (DC) Power Supply (AC)
Power ON/OFF
Before you begin the installation, make sure that you have the following:
Site Environment:
SYS
1
2
3
4
5
6
7
8
PWR
S3400-24T4FP
1357911
810 12
6
4
2
SYS
1
2
3
4
5
6
7911 13 15 17 19 21 23 25 27 25F 27F
10 12 14 16 18 20 22 24 26 28 26F 28F
PoE
PoE
Lnk/Act
RESET
Lnk/Act
8
PWR
S3400-24T4FP

Rack Mounting
1. Secure the mounting brackets to the two sides of the switch with eight M3 screws.
15 17 19 21 23
16 18 20 22 24
25 27
COMBO
25F 27F
26 28 26F 28F
CONSOLE
PoE
Desk Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on a desk.
Mounting the Switch
SYS
1
2
3
4
5
6
7911 13 15 17 19 21 23 25 27 25F 27F
10 12 14 16 18 20 22 24 26 28 26F 28F
PoE
PoE
Lnk/Act
RESET
Lnk/Act
8
PWR
S3400-24T4FP
13 15 17 19 21 23
14 16 18 20 22 24
26 28 26F 28F
CONSOLE
PoE
1357911
810 12
6
4
2
25 27 COMBO 25F 27F
SYS
1
PWR
S3400-24T4FP

2. Attach the switch to the rack using four M6 screws and cage nuts.
25 27
COMBO
25F 27F
1357911
810 12
6
4
2
13 15 17 19 21 23
14 16 18 20 22 24
26 28 26F 28F
CONSOLE
13 15 17 19 21 23 25 27 25F 27F
14 16 18 20 22 24 26 28 26F 28F
PoE
PoE
Lnk/Act
RESET
Lnk/Act
PoE
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch back panel with the washers and
screws.
Grounding the Switch
CAUTION: The earth connection must not be removed unless all supply connections have
been disconnected.
100-240V AC
50/60Hz

25 27
COMBO
25F 27F
1357911
810 12
6
4
2
13 15 17 19 21 23
14 16 18 20 22 24
26 28 26F 28F
CONSOLE
SYS
1
2
3
4
5
6
7911 13 15 17 19 21 23 25 27 25F 27F
10 12 14 16 18 20 22 24 26 28 26F 28F
PoE
PoE
Lnk/Act
RESET
Lnk/Act
8
PWR
S3400-24T4FP
PoE
100-240V AC
50/60Hz
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to an AC power source.
Connecting the Power
WARNING: Do not install power cables while the power is on.
Connecting the RJ45 Ports
1. Connect an Ethernet cable to the RJ45 port of IP cameras, IP telephones, Access Points (AP), or other
network devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.

25 27
COMBO
25F 27F
1357911
810 12
6
4
2
13 15 17 19 21 23
14 16 18 20 22 24
26 28 26F 28F
CONSOLE
21 23 25 27 25F 27F
20 22 24 26 28 26F 28F
PoE
PoE
Lnk/Act
RESET
Lnk/Act
PoE
Connecting the SFP/SFP+ Ports
1. Plug the compatible SFP/SFP+ transceiver into the SFP/SFP+ port.
2. Connect a ber optic cable to the ber transceivers. Then connect the other end of the cable to
other ber devices.
WARNING: Laser beams will cause eye damage. Do not look into bores of optical modules
or optical bers without eye protection.
Connecting the Console Port
1. Insert the RJ45 connector of the console cable into the RJ45 console port on the front of the switch.
2. Connect the other end of the console cable to the RS-232 serial port on the computer.
21 23
22 24
25 27
COMBO
25F 27F
26 28 26F 28F
CONSOLE
PoE

Conguring the Switch
Step 1: Connect the computer to any Ethernet port of the switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x. ("x" is any number from 2 to 254.). Set the
subnet mask of the computer to 255.255.255.0.
Conguring the Switch Using the Web-based Interface
?x
OK Cancel
General
IP address:
Subnet mask:
Default gateway:
You can get IP settings assigned automatically if your network
supports this capability. Otherwise, you need to ask your network
administrator for the appropriate IP settings.
Internet Protocol Version 4(TCP/IPv4) Properties
Use the following IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit Advanced...
. . . 21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNS server address automatically
Use the following DNS server addresses:
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password,
admin/admin.
Step 4: Click sign in to display the web-based conguration page.
Step 1: Connect a computer to the switch's console port using the supplied console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 115200 bits per second, 8 data bits, no parity, 1 stop
bit and no ow control.
Conguring the Switch Using the Console Port

Step 4: Enter the default username and password, admin/admin.
x
Quick Connect
Protocol: Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect Cancel
COM3
115200
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:
Troubleshooting
After loading fails, the system will keep running in the original version. At this time, users should
re-check if physical port connections are good rstly. If some ports are not connected, then re-connect
them to ensure that physical connections are correct, and begin re-loading. If physical connections
are correct, then check the loading process information displayed on the super terminal to verify if
there are input errors. If there are input errors, correct them and re-load.
Loading Failure Troubleshooting
If system password is lost or forgotten, the following method can be used to reset the password:
User Password Lost Troubleshooting
1. Connect the console port of the switch to the computer through the console cable.
2. Press ctrl + b to enter the Uboot mode.
3. Start the system with an empty conguration le with no password.
Bootrom#boot_ash_nopass
Bootrom#Do you want to revert to the default cong le?[Y|N|E]:
NOTE: Forgetting your username and password and restoring them through console port
may cause conguration loss and business interruption. Please remember your username
and password.

Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will oer a
free return within 30 Days from the day you receive your goods. This excludes any custom made
items or tailored solutions.
Warranty: PoE+ Series Switches enjoys 4 years limited warranty against defect in
materials or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
4
Conguration System Troubleshooting
1. Make sure the power supply is normal and the console cable is properly connected.
2. Check if the console cable is the right type.
3. Check if the control cable driver is properly installed on the computer.
4. Ensure the parameters of the HyperTerminal are correct.
Support and Other Resources
Download
Help Center
Contact Us
https://www.fs.com/download.html
https://www.fs.com/service/help_center.html
https://www.fs.com/contact_us.html
Copyright © 2020 FS.COM All Rights Reserved.