FS S3910 Series User manual

SET
CONSOLE
TUS PWR1 PWR2 ID
21 43 65 87 109 12
11 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 38
37 4039 4241 4443 4645 4847 5049 5251
SFP+
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S3910-48TS
RESET
Green=1000M On=Link
Yellow=10/100M Flashing=ACT
CONSOLE
ATUS PWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
25 26 27 28
SFP+
S3910-24TS
MANAGED L2+ GIGABIT SWITCHES
S3910 Series Switches
Quick Start Guide V1.0

RESET
Green=1000M On=LinkYellow=10/100M Flashing=ACT
CONSOLE
STATUS PWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
25 26 27 28
SFP+
S3910-24TS
RESET
CONSOLE
STATUS PWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
Green=1000M Yellow=10/100M On=Link Flashing=ACT S3910-48TS
Introduction
Thank you for choosing S3910 Series Stackable Managed Switches. This guide is designed to
familiarize you with the layout of the switch and describes how to deploy the switch in your network.
S3910-24TS
S3910-48TS
Accessories
Power Cord x2 Grounding Cable x1 Rubber Pad x4
NOTE: S3910 series switches have dust plugs delivered with them. Keep the dust plugs
properly and use them to protect idle optical ports.
Mounting Bracket x2 M4 Screw x8

RESET
Green=1000M On=LinkYellow=10/100M Flashing=ACT
CONSOLE
STATUS PWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
25 26 27 28
SFP+
S3910-24TS
RESET
Green=1000M On=LinkYellow=10/100M Flashing=ACT
CONSOLE
STATUS PWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
25 26 27 28
SFP+
S3910-24TS
RESET
CONSOLE
STATUS PWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S3910-48TS
Hardware Overview
Front Panel Ports
Front Panel Button
CONSOLE
S3910-24TS
SFP+RJ45
RESET
S3910-24TS / S3910-48TS
CONSOLE SFP+RJ45
S3910-48TS
Ports Description
RJ45
CONSOLE
SFP+
10/100/1000BASE-T ports for Ethernet connection
SFP+ ports for 1/10G connection
An RJ45 console port for serial management
Button Description
RESET Restart: Press and hold the RESET button for more than ve seconds, and
then wait for ten seconds.

RESET
Green=1000M On=LinkYellow=10/100M Flashing=ACT
CONSOLE
STATUS PWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
25 26 27 28
SFP+
S3910-24TS
RESET
CONSOLE
STATUS PWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S3910-48TS
Back Panels
S3910-24TS / S3910-48TS
Front Panel LEDs
S3910-24TS
SFP+
RJ45
STATUS
PWR1 ID
PWR2
S3910-48TS
PWR1
PWR2
Dual Power Supplies Grounding Point
SFP+
RJ45
PWR1 ID
STATUS
PWR2
LEDs DescriptionStatus
STATUS
O
Blinking Green
Solid Yellow
Solid Red
Solid Green
System is being initialized.
Switch is operational.
Switch is not receiving power.
1. Severe temperature warning:
The temperature severely exceeds the temperature limit, so
the system is going to restart.
2. The switch is faulty.
Moderate temperature warning:
Check the working environment of the switch immediately.

LEDs DescriptionStatus
PWR1/PWR2
ID
RJ45
SFP+
O
Solid Green
Solid Red
A power supply is connected and able to work.
A redundant power supply fails or no AC cable is connected.
No power supply module is connected.
O
Solid Blue
O
Locating is enabled. Operation and maintenance sta turn
on and o the LED remotely.
The port is not connected.
Solid Green The port is connected at 1000 Mbps.
Blinking Green The port is receiving or transmitting trac at 1000 Mbps.
Solid Yellow The port is connected at 10/100 Mbps.
Blinking Yellow The port is receiving or transmitting trac at 10/100 Mbps.
O The port is not connected.
Solid Green The port is connected.
Blinking Green The port is receiving or transmitting trac.
Locating is disabled.

Before you begin the installation, make sure that you have the following:
Site Environment:
Do not operate it in an area that exceeds an ambient temperature of 50°C.
Installation Requirements
Phillips screwdriver.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables, ber optical cables and console cable for connecting
network devices.
Do not install the equipment in a dusty environment.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
The installation site must be well ventilated. Ensure that there is adequate airow around the
switch.
The switch should be installed at least 1U (44.45mm) away from devices to its sides.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Ensure rack and working platforms are well earthed.
Desk Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on a desk.
Mounting the Switch
RESET
CONSOLE
STATUS PWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423
Green=1000M Yellow=10/100M On=Link Flashing=ACT
RESET
CONSOLE
STATUS PWR1 PWR2 ID
21 43 65 87 109 1211 1413 15
Green=1000M Yellow=10/100M On=Link Flashing=ACT

3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
S3910-48TS
20 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
S3910-48TS
Rack Mounting
1. Secure the mounting brackets to the two sides of the switch with eight M4 screws.
2. Attach the switch to the rack using four M6 screws and cage nuts.
RESET
CONSOLE
STATUS PWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 21
Green=1000M Yellow=10/100M On=Link Flashing=ACT

S3910-48TS
2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
S3910-48TS
1. Attach the mounting brackets to the switch with the supplied screws.
Wall Mounting
2. Use the expansion screws to securely attach the mounting brackets on the wall.
NOTE: Suitable for mounting on concrete or other non-combustible surface only.
S3910-48TS

PWR1
PWR2
Installing the Power Supply Module
1. Take a new power module out of the package.
2. Take the plane printed with power information as the top panel of the power module. Hold the
handle of the power module with one hand, and hold the end of the power module with the other
hand. Insert it into the chassis along the guide rail steadily and slowly until a click is heard, and make
sure that it is in good contact with the power slot.
NOTE: Insert the power module steadily. Please pay attention to the direction of the power
panel to avoid wrong insertion. If the position is not proper, press the plug of the power
module and hold on to the module handle with one hand to pull it out slowly, then
re-insert it.

12
2
345678910 11 12
12
13 14
14
15 16 17 18 19 20 21 22 23 24
24
G
r
e
en=10
G/
1G On=Lin
k
F
l
as
h
i
n
g
=
ACT
R
G
-
S
5
310-
2
4
G
T
4
X
S
G
r
ee
n=1
0
G
/1G
Y
e
l
l
ow=10/100M
O
n=L
i
n
k
F
l
ashi
ng
=
A
CT
Reset
St
a
t
us
P
W
R
1
P
W
R
2
ID
PWR1
PWR2
WARNING: Do not install power cable while the power is on.
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch back panel with the washers and
screws.
Grounding the Switch
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to an AC power source.
Connecting the Power

WARNING: Laser beams will cause eye damage. Do not look into bores of optical modules
or optical bers without eye protection.
1. Plug the compatible SFP+/SFP transceiver into the SFP+ port.
2. Connect a ber optic cable to the ber transceiver. Then connect the other end of the cable to
another ber device.
Connecting the SFP+ Ports
1. Connect an Ethernet cable to the RJ45 port of a computer, printer, network storage, or other
network devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.
Connecting the RJ45 Ports
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
25 26
49F 50F 51F 52F
38
48
37
38
39
40
41
42
43
44
45
46
47
48
25
26
26
27
28
29
30
31
32
33
34
35
36
36
22 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
S3910-48TS

25
26
27
CONSOLE
MGT
SYS
PWR
RESET
28
RESET
CONSOLE
STATUSPWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S3910-48TS
RESET
CONSOLE
STATUSPWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S3910-48TS
RESET
CONSOLE
STATUSPWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S3910-48TS
RESET
CONSOLE
STATUSPWR1 PWR2 ID
21 43 65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
Green=1000M Yellow=10/100M On=Link Flashing=ACT
S3910-48TS
RESET
CONSOLE
STATUS PWR1 PWR2 ID
21 43 65 87 109 1211 1413 16
15 1817 2019 2221 23
Green=1000M Yellow=10/100M On=Link Flashing=ACT
1. Insert the RJ45 connector into the RJ45 console port on the front of the switch.
2. Connect the DB9 female connector of the console cable to the serial port on the computer.
Connecting the Console Port
Stacking the S3910 Series Switches
The S3910 series switches support stacking up to 4 switches between the same models together.
Switches in the series can be physically stacked using optical ber cables connected to SFP+
transceivers or 10G Direct Attach Cables (DAC). The four SFP+ ports on the switch can be used for
physical stacking.

2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251
SFP+
S3910-24TS
IE 8/9/10/11, Google Chrome, Firefox are supported
Login
admin
*****
Configuring the Switch
Configuring the Switch Using the Web-based Interface
x
Cancel
General
IP address:
Subnet mask:
Default g a t e w a y :
You can get IP settings assigned automatically if your net w o r k
supports this capabil i t y . O t herwise, y o u need t o a sk your net w o r k
adminis t r a t o r f o r the appropr i a t e IP settings .
In ter net Pro toc ol Versi on 4 ( T CP/IPv4) P roperties
Us e the following IP address:
Obtain an IP address a utomatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit A d v anc e d ...
. . .21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNSser v e r a ddres s automatically
Us e the following DNS s e r ve r addresses:
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password,
admin/admin.
Step 1: Connect the computer to the business port of the switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x.(“x” is any number from 2 to 254.)
Step 4: Click Login to display the web-based conguration page.
OK

Troubleshooting
In the case of compatible cables and transceivers, the port cannot be up, please try to modify the
port mode to adapt or force the port speed to 1G/10G.
10G Port is not Working
Configuring the Switch Using the Console Port
Step 1: Connect a computer to the switch's console port using the console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 9600 bits per second, 8 data bits, no parity, 1 stop
bit and no ow control.
Step 4: After setting the parameters, click Connect to enter.
x
Quick Connect
Protocol:
The port may be manually entered or selected from the list.
Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect
Cancel
COM3
9600
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:
1. Test network connectivity through ping.
2. If the network is reachable, try restarting the switch.
3. Check if the corresponding service is enabled.
Connecting the Switch Remotely Unsuccessfully

1. Ensure the switch ports are in the no shutdown state.
2. Check if the switch can read the DDM information.
3. Check if the port speed setting is correct.
4. Try looping the switch cable.
The Port is not Working, the LED Indicator is O
Support and Other Resources
Download
Help Center
Contact Us
https://www.fs.com/download.html
https://www.fs.com/service/help_center.html
https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will oer a
free return within 30 Days from the day you receive your goods. This excludes any custom made
items or tailored solutions.
Warranty: S3910 Series Switches enjoy 5 years limited warranty against defect in materials
or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
5
Copyright © 2020 FS.COM All Rights Reserved.
Q.C. PASSED
Other manuals for S3910 Series
2
This manual suits for next models
2
Table of contents
Other FS Switch manuals

FS
FS S5800 Series User manual

FS
FS TAP Series User manual

FS
FS S3700-24T4F Instruction Manual

FS
FS Fiberstore S8050-20Q4C User manual

FS
FS S3410 Series Operating manual

FS
FS S3700-24T4F Instruction Manual

FS
FS PoE+ Series User manual

FS
FS S5850-24XMG User manual

FS
FS S3150-8T2FP User manual

FS
FS IES5100-24TF User manual
Popular Switch manuals by other brands

Dinel
Dinel GPLS-25 Series instruction manual

COMEPI
COMEPI 010 ISTR 03 SC 1221-02 Additional safety and use instructions

SMC Networks
SMC Networks ZSE20CF Series Operation manual

Arista
Arista 7060 Series quick start guide

Code 3
Code 3 ROCKERPAK430 Installation & operation manual

Knox Video