- (01 - 05) -
WALL MOUNTED TYPE
ASÜA24-30LC(F)
WALL MOUNTED TYPE
ASÜA24-30LC(F)
SPECIFICATIONS3.
Type WALL MOUNTED
INVERTER HEAT PUMP
Model name ASÜA24LCC ASÜA30LCC
Power source 230V~ 50Hz
Available voltage range 198 - 264V ~ 50Hz
ENERGY STAR RANK Cooling A B
Heating A B
Capacity
Cooling
Rated kW 7.10 8.00
BTU/h 24,200 2 7,3 0 0
Min.-Max. kW 0.9-8.0 2.9-9.0
BTU/h 3,100-27,300 9,900-30,700
Heating
Rated kW 8.10 9.00
BTU/h 27, 6 0 0 30,700
Min.-Max. kW 0.9-10.6 2. 2-11.0
BTU/h 3,100-36,200 7,5 0 0 - 3 7,6 0 0
Input power
Cooling Rated
kW
2.21 2.66
Min.-Max. 0.11-2 .62 0.58-3.60
Heating Rated 2.24 2.64
Min.-Max. 0.11-3.6 8 0.50-4.30
Current
Cooling Rated
A
9.7 11.7
Max.* 12 17
Heating Rated 9.8 11.6
Max.* 17.5 19
EER Cooling kW/kW 3.21 3.01
COP Heating 3.62 3.41
SENSIBLE CAPACITY Cooling kW 5.54 5.34
POWER FACTOR Cooling %99 99
Heating 99 99
Moisture removal l/h (pints/h) 3.0(5.3) 3.4(6.0)
Fan
Airow
rate
Cooling
High
m3/h
1100 110 0
Med 900 900
Low 740 740
Quiet 620 620
Heating
High 1100 1100
Med 900 900
Low 740 740
Quiet 620 620
Type × Q'ty Cross ow fan × 1
Motor output W42 42
Sound pressure level
Cooling
High
dB(A)
47 47
Med 41 41
Low 36 36
Quiet 32 32
Heating
High 45 45
Med 36 36
Low 32 32
Quiet 32 32
Heat exchanger type
Dimensions
(H × W × D) mm
Main : 378 × 832 × 26.6
Sub : 84 × 832 × 13.3
Main : 378 × 832 × 26.6
Sub1 : 84 × 832 × 13.3,
Sub2 : 84 × 832 × 13.3
Fin pitch Main : 1.2, Sub : 1.4 Main : 1.2, Sub1 : 1.4, Sub2 : 1.4
Rows x Stages Main : 2 × 18, Sub : 1 × 4
Main : 2 × 18,
Sub : 1 × 4,
Sub2 : 1 × 4
Pipe type Copper
Fin type Aluminium
Enclosure
Material Polystyrene
Colour WHITE
Approximate colour of MANSELL N9.25/
Dimensions
( H×W ×D )
Net mm 320 × 998 × 228
Gross 319 × 1090 × 429
Weight Net kg(lb.) 14 (30.8)
Gross 18 (39.6)
Connection pipe Size Liquid mm Ø6.35 (Ø 1/4 in.) Ø9.52 (Ø 3/8 in.)
Gas Ø15.88 (Ø 5/8 in.)
Method Flare
Operation range Cooling °C 18 to 32
%RH 80 or less
Heating °C 30 or less
Remote controller type Wireless
Drain pipe Material PVC
Size mm Outer diameter: 28 / Inner diameter: 16
Note :
Specications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB/19°CWB. and outdoor temperature of 35°CDB/24°CWB.
Heating : Indoor temperature of 20°CDB/15°CWB. and outdoor temperature of 7°CDB/6°CWBA.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
The maximum current is the maximum value when operated within the operation range(temperature)
* The maximum current is the total current of indoor unit and outdoor unit.