EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Gaggenau
  6. •
  7. Ventilation Hood
  8. •
  9. Gaggenau AH 590-720 Product guide

Gaggenau AH 590-720 Product guide

Other manuals for AH 590-720

2

Other Gaggenau Ventilation Hood manuals

Gaggenau VL 200 120 User manual

Gaggenau

Gaggenau VL 200 120 User manual

Gaggenau AW 540 Product guide

Gaggenau

Gaggenau AW 540 Product guide

Gaggenau AW 220 191 CN User manual

Gaggenau

Gaggenau AW 220 191 CN User manual

Gaggenau VL 040 User manual

Gaggenau

Gaggenau VL 040 User manual

Gaggenau AR413122 AD854048 User manual

Gaggenau

Gaggenau AR413122 AD854048 User manual

Gaggenau AF210762 User manual

Gaggenau

Gaggenau AF210762 User manual

Gaggenau AR 413 121 User manual

Gaggenau

Gaggenau AR 413 121 User manual

Gaggenau VL 051-107 Service manual

Gaggenau

Gaggenau VL 051-107 Service manual

Gaggenau AW 442 720 User manual

Gaggenau

Gaggenau AW 442 720 User manual

Gaggenau AW 250 User manual

Gaggenau

Gaggenau AW 250 User manual

Gaggenau AW 480 User manual

Gaggenau

Gaggenau AW 480 User manual

Gaggenau AC 250 User manual

Gaggenau

Gaggenau AC 250 User manual

Gaggenau AL400122 User manual

Gaggenau

Gaggenau AL400122 User manual

Gaggenau AI 280720 User manual

Gaggenau

Gaggenau AI 280720 User manual

Gaggenau AI 400720 User manual

Gaggenau

Gaggenau AI 400720 User manual

Gaggenau AH 900791 User manual

Gaggenau

Gaggenau AH 900791 User manual

Gaggenau VL 410 User manual

Gaggenau

Gaggenau VL 410 User manual

Gaggenau VL 051-907 Product guide

Gaggenau

Gaggenau VL 051-907 Product guide

Gaggenau AH 600-190 Product guide

Gaggenau

Gaggenau AH 600-190 Product guide

Gaggenau AL 400 791 User manual

Gaggenau

Gaggenau AL 400 791 User manual

Gaggenau AW 442 720 User manual

Gaggenau

Gaggenau AW 442 720 User manual

Gaggenau AW 2 Series User manual

Gaggenau

Gaggenau AW 2 Series User manual

Gaggenau AC 250 User manual

Gaggenau

Gaggenau AC 250 User manual

Gaggenau AH 530-720 Product guide

Gaggenau

Gaggenau AH 530-720 Product guide

Popular Ventilation Hood manuals by other brands

Haier CXW-219-D67 null

Haier

Haier CXW-219-D67 null

emmeti RECUPA MED A-140 Installation and use manual

emmeti

emmeti RECUPA MED A-140 Installation and use manual

Nibe F135 user manual

Nibe

Nibe F135 user manual

Zephyr Spruce AK9834BS Use, care and installation guide

Zephyr

Zephyr Spruce AK9834BS Use, care and installation guide

Kuppersberg INTRO 60 Technical Passport

Kuppersberg

Kuppersberg INTRO 60 Technical Passport

Hisense MH6INBG manual

Hisense

Hisense MH6INBG manual

Miele DA 1255 Operating and installation instructions

Miele

Miele DA 1255 Operating and installation instructions

Broan 46000 Specification sheet

Broan

Broan 46000 Specification sheet

GE Profile PV977 Owner's Manual & Installation Instructions

GE

GE Profile PV977 Owner's Manual & Installation Instructions

FALMEC FFRIA24W5FS Instruction booklet

FALMEC

FALMEC FFRIA24W5FS Instruction booklet

Whirlpool RH2600XL-1 SERIES installation instructions

Whirlpool

Whirlpool RH2600XL-1 SERIES installation instructions

ETNA AV360RVS Instructions for use

ETNA

ETNA AV360RVS Instructions for use

JUNO JDF603E6 installation manual

JUNO

JUNO JDF603E6 installation manual

Miele DA 6708 D Operating and installation instructions

Miele

Miele DA 6708 D Operating and installation instructions

Tricity Bendix LE 150 Installation & operating instructions

Tricity Bendix

Tricity Bendix LE 150 Installation & operating instructions

AEG X68163BV1 user manual

AEG

AEG X68163BV1 user manual

AEG 125 D operating instructions

AEG

AEG 125 D operating instructions

Smeg KSEV97X instruction manual

Smeg

Smeg KSEV97X instruction manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Operating and assem ly instructions
AH 590-720
Freely Suspended Insular Hood
1
AH 590-720
. Assembly instructions Page 13-19
6.1 Technical data Page 13
6.2 Installation Page 14-19
13
.1 Technical data
Weight without support frame and LK: 35 kg
Weight with support frame and LK: max. 60 kg
Dimensions: 473/16 ´ ´ x 27 1/2´´/ 1198 x 700 mm
Electrical connection
Pay attention to the rating plate data.
The appliance must only e connected y an
authorised specialist. The specialist is respon-
si le for perfect functioning of the appliance at its
installation location. He must explain the operating
principle of the appliance to the user with refe-
rence to the operating instructions. He must explain
to the user how the appliance can e isolated from
the mains whenever required.
Connection possibilities
It must e possi le to isolate all poles of the
appliance from the mains y way of the domestic
fuse, or y means of accessi le isolating device
with a contact gap of at least 3 mm.
6. Assem ly instructions
.2 Installation
WARNING - TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
a.) Installation work and electrical wiring must e
done y qualified person(s) in accordance with
all applica le codes and standards, including
fire-rated construction.
.) Sufficient air is needed for proper com ustion
end exhausting of gases through the flue
(chimney) of fuel urning equipment to prevent
ack drafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those pu lished y the National Fire
Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air
Conditioning (ASHRAE), and the local code
authorities.
c.) When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
d.) Ducted fans must always e vented to the
outdoors.
e.) If this unit is to e installed over a tu or shower,
it must e marked as appropriate for the appli-
cation and e connected to a GFCI (Ground
Fault Circuit Interrupter) - protected ranch
circuit.
f.) NEVER place a switch where it can e reached
from a tu or shower.
WARNING:
To reduce the risk of fire, use only metal ductwork.
The applica le regulations of the energy supply
companies and the regional construction regula-
tions must e o served when installing the hood.
The minimum distance from the worktop to the
ottom edge of the wall hood is for electrical appli-
ances 24´ ´ / 600 mm and for gas appliances 30´´/
762 mm.
The extractor hood was conceived for the exhaust
air mode. The exhaust air can e routed into a se-
parate exhaust air shaft or directly into the open
through the outside wall.
It is not allowed to pass the exhaust air into a flue
or exhaust air chimney that is in operation or into a
shaft that is linked to the heating asement. Consult
the chimney sweep responsi le for your district
whenever you wish to pass the exhaust air into a
chimney that is not in operation.
During the course of planning, a chimney sweep
must e consulted if a room air-dependent hearth
is operated in the same room as the one in which a
hood is operated in the exhaust air mode. Adequate
incoming air must e ensured. The applica le con-
struction and safety regulations must e o served.
Adequate incoming air must e ensured if a wood,
coal, gas or oil heater or an open hearth is operated
in the same room as the one in which the hood is
installed.
Safe operation is possi le whenever the partial
vacuum in the place where the firing equipment
is installed does not exceed 4 Pa (0.04 m ar).
This can e achieved whenever the air needed for
com ustion is a le to enter through openings that
cannot e sealed, for example in doors, windows,
incoming/exhaust air wall oxes or y other techni-
cal means.
14
15
Flexi le aluminium pipes, corrosion-protected
sheet metal pipes and exhaust air pipes whose
material conforms to fire B1 in accordance with
DIN 4102 can e used. Exhaust air pipes should
have a nominal diameter of 6´ ´ / 150 mm.
Pay particular attention to ensuring that
– the exhaust air ducts and pipes are kept as short
as possi le
– the pipes are not laid at an acute angle, ut as
ends and that they are inserted into the shaft at
an inclined upward angle and
– there are no cross-sectional constrictions in the
upward direction (this reduces the volume flow).
As standard, the low-out opening of the extractor
hood is in the upward direction.
To pass exhaust air through the outer wall, we
recommend the use of our telescopic wall ox
TM 150-045 (Ø 6´ ´ / 150 mm).
Note:
to prevent the ingress of water, e.g. condensate or
rain water from an uncovered exhaust air shaft, our
condensate separator RV 060-150 must e installed
in the exhaust air line. The condensate separator
must still e accessi le after installation.
The duct units listed elow are availa le depen-
ding on the height of the ceiling:
Stainless steel-design ventilation duct:
LK 590-010 for ceiling heights of
7 ´´ 10 ´´- 8´´ 8 ´ ´ / 2.39 - 2.64 m
LK 590-020 for ceiling heights of
8 ´´ 8 ´ ´ - 9´´ 6 ´ ´ / 2.64 - 2.89 m
LK 590-030 for ceiling heights of
9 ´´ 6 ´ ´ - 10 ´´ 4 ´ ´ / 2.89 - 3.14 m
Aluminium-design ventilation duct:
LK 590-011 for ceiling heights of
7 ´´ 10 ´´- 8´´ 8 ´ ´ / 2.39 - 2.64 m
LK 590-021 for ceiling heights of
8 ´´ 8 ´ ´ - 9´´ 6 ´ ´ / 2.64 - 2.89 m
LK 590-031 for ceiling heights of
9 ´´ 6 ´ ´ - 10´´ 4 ´ ´ / 2.89 - 3.14 m
The dimensions a ove refer to a distance of 5’3” /
1.60 m from the floor to the ottom edge of the
hood.
If required, custom made duct units are availa le at
an extra charge.
The power connection must e placed within the
ventilation duct on the ceiling.
(15
15
/16")
405
(47
3
/16")
1200
(27")
700
(9
14
/16")
251,5
Fig. 18
2.39 - 3.14 m
7’10” - 10’4”
ceiling height
min. 600 (24
´´ ´´
) over electric hob
min. 762
(30
´´ ´´
)
over gas hob
Installation above gas cooker / gas hob
Installation of the appliance a ove a gas cooking
device must conform to national safety regulations.
A minimum distance of 30´´/ 762 mm etween the
hood and gas appliance must e o served.
Gas appliances may only e used under the
extractor hood when pots and pans are placed on
them!
Operation above gas cooker / gas hob
During operation the heat load of all hotplates and
oven must not exceed 13.5 kW.
Should the nominal heat loads of all hotplates com-
ined exceed 13.5 kW (e.g. com ination with WOK
urner), during operation only a com ination of hot-
plates of max. 13.5 kW must e used.
Exception:
the nominal heat loads of all hotplates com ined to
a maximum of 15.4 kW can e operated for a very
short period of time (max. 15 minutes), if the hood is
running on a minimum of level 2. Otherwise there is
a risk of urns when touching the exterior of the ex-
tractor hood.
16
17
Installation:
1. Using the drilling template mark the position of
the screws on the ceiling.
2. Drill 4 holes Ø 8 mm for the wall plugs. Push the
plugs flush with the ceiling (Fig. 19).
3. Turn two screws to a 10 mm gap. Both screws
are placed in a position, in which at a later stage
of the installation the key-holes of the suppor-
ting frame are found (namely front left and ack
right from the control panel of the hood).
4. Place the hood on a suita le ase. Connect the
air outlet pipe to the hood.
5. Screw the support frame to the hood with
4 screws. The marking “FRONT” must e on the
same side as the control panel (Fig. 20).
Ventilation ducts LK 590-020/030/021/031
only: the enclosed extension module should e
mounted on top of the support frame. Follow the
a ove instructions for mounting the support
frame and hood.
(13
5
/
8
")
346
(7
7
/
8
")
200
Fig. 19
Fig. 20
Note:
the extractor hood is to e installed to a kitchen
ceiling or suspended ceiling. Ensure that the
ceiling is capa le of providing a firm hold for a
maximum weight of hood and accessories of 60 kg.
Before marking the securing holes, make sure that
no electricity wires or water pipes or other wires/
pipes are laid at the drilling points in the ceiling.
Before installation check the enclosed wall plugs
and screws are suita le for your ceiling. If neces-
sary use special wall plugs.
18
. Adjust the support frame to the desired height
and secure with 8 screws. The length of the
support frame can e adjusted in steps of
3/4´´/ 20 mm from 153/16 ´´/ 386 mm to
25 7/16 ´´/ 646 mm (Fig. 21).
Note:
ensure that the minimum distance etween the
ho and the extractor hood is maintained –
24´´/ 600 mm for an electric ho and 30´´/ 762 mm
for a gas ho
7. Stainless steel ventilation ducts only
(LK 590-010/020/030):
pull the protective film off the metal surface.
8. Place oth ventilation ducts over the support
frame. Take care not to scratch the sensitive
duct surface.
9. Attach the electrical plug to the support frame
with sticky tape so that it can e easily reached
later.
10. Hang the hood and the support frame with the
two key-holes to the two screws in the ceiling
(Fig. 22).
Attention: the two screws cannot support
the weight of the hood. Therefore it must be
supported at this stage!
Fig. 21
Fig. 22
11. Adjust the hood to the final position and attach it
with all 4 screws to the ceiling (Fig. 23).
12. Connect the air outlet pipe.
13. Connect the hood to the electricity supply.
14. Pull the top duct unit up into its final position.
Secure the top duct unit with 4 screws on the
support frame (Fig. 24).
Note: avoid scratches when pulling the ele-
ments apart y placing the assem ly template,
for example, over the top edge of the ottom
duct to protect it.
15. Replace the glass plates with the printed side
facing down. Position the glass plates at the
chimney side first.
Note: when putting the glass plates in place,
make sure that you do not scratch the chimney.
1 . Check the appliance functions correctly.
5750202702 en 11.02 SK 19
Fig. 23
Fig. 24
5551 McFADDEN AVENUE
HUNTINGTON BEACH, CA 92649
USA
Y(800) 828-9165 · FA (714) 901-0979
www.gaggenau.com/us
GAGGENAU HAUSGERÄTE GMBH
P.O. BO 10 02 50 · D-80076 MÜNCHEN
GERMANY
Y(0 89) 45 90-01
FA (0 89) 45 90-23 47