9
ESTRO GT
ESTRO GT 1.2 1 3 4 5 6 7 8 9 95 11 12
GTFL Kg 19,1 20,1 20,1 24,8 24,8 30,4 30,4 30,9 31,0 41,3 50,4
GTCL Kg 19,7 20,0 20,6 25,5 26,7 31,0 32,3 32,3 - - -
GTFA Kg 18,1 19,1 19,1 23,3 23,3 28,4 28,4 28,9 - 38,8 47,9
GTFC Kg 14,1 15,1 15,1 18,8 18,8 22,9 22,9 23,4 24,0 31,8 38,8
GTFU Kg 20,1 21,1 21,1 26,8 26,8 32,4 32,4 32,9 33,0 43,8 53,0
GTFF Kg 14,1 15,1 15,1 18,8 18,8 22,9 22,9 23,4 - 31,8 38,8
GTFP Kg 20,1 21,1 21,1 26,8 26,8 32,4 32,4 32,9 - 43,8 53,0
FC66003937 - Rev 00 ALL COPYING, EVEN PARTIAL, OF THIS MANUAL IS STRICTLY FORBIDDEN
4.1 WEIGHTS
4 RATINGS AND TECHNICAL DATA
1Water temperature 7/12°C, air temp. 27°C D.B., 19°C W.B. (47% R.H.)
2Water temperature 50°C, water flow rate same as in cooling mode, air inlet temperature 20°C
3Water temperature 70/60°C, air temp. 20°C
4Sound power measured according to standards ISO 3741 and ISO 3742
5Sound pressure level measured at a distance of 1 m with a directivity factor of 4
ESTRO GT 7M 8 8M 9
Fan speed min med max min med max min med max min med max
Total cooling capacity (1) (E) kW 2,48 3,39 4,58 2,64 3,27 4,30 2,78 3,70 4,96 3,17 3,89 0,02
Sensible cooling capacity (1) (E) kW 1,73 2,37 3,22 1,80 2,38 3,13 1,94 2,59 3,50 2,07 2,82 3,81
Water flow (1) l/h 427 582 785 423 561 738 477 635 850 1.650 2.230 3.030
Water pressure drop (1) (E) kPa 6 11 18 5 8 12 7 12 20 7 10 14
Heating capacity (2) (E) kW 3,01 4,08 5,49 3,07 3,93 5,02 3,36 4,45 5,94 4,02 4,88 5,87
Water pressure drop (2) (E) kPa 5 9 14 4 6 10 6 10 17 6 8 12
Heating capacity (3) kW 5,06 6,84 9,22 5,21 6,62 8,42 5,64 7,46 9,98 6,81 8,25 9,93
Water flow (3) l/h 444 601 808 457 581 739 495 654 876 597 724 871
Water pressure drop (3) kPa 5 8 14 4 6 9 6 10 16 6 9 12
Air flow m3/h 320 450 640 361 497 706 361 497 706 470 605 785
Power imput (E) W 6 9 19 7 11 24 7 11 24 10 17 32
Control voltage V 2,5 3,6 5,7 2,8 4,1 6,5 2,8 4,1 6,5 3,8 5,3 7,6
Sound power level (4) (E) dB/A 35 43 51 35 43 53 35 43 53 43 49 56
Sound pressure level dB/A 30 38 46 30 38 48 30 38 48 38 44 51
Additional coil heating capacity (3) (E) kW not available 3,56 4,26 5,11 not available 4,09 4,67 5,31
Water flow (3) l/h not available 312 374 448 not available 359 410 466
Water pressure drop (3) (E) kPa not available 7 9 13 not available 6 8 10
Hydraulic connections std inch 1/2 1/2 1/2 1/2
DF inch not available 1/2 not available 1/2
Water content std dm3 1,33 1,4 1,8 1,4
DF dm3 not available 0,4 not available 0,4
ESTRO GT 9M
Fan speed min med max
Total cooling capacity (1) (E) kW 3,52 4,37 5,40
Sensible cooling capacity (1) (E) kW 2,47 3,07 3,82
Water flow (1) l/h 605 750 926
Water pressure drop (1) (E) kPa 11 16 24
Heating capacity (2) (E) kW 4,24 5,24 6,47
Water pressure drop (2) (E) kPa 9 13 19
Heating capacity (3) kW 7,11 8,79 10,87
Water flow (3) l/h 623 772 953
Water pressure drop (3) kPa 9 13 19
Air flow m3/h 470 605 785
Power imput (E) W 10 17 32
Control voltage V 3,8 5,3 7,6
Sound power level (4) (E) dB/A 43 49 56
Sound pressure level dB/A 38 44 51
Additional coil heating capacity (3) (E) kW not available
Water flow (3) l/h not available
Water pressure drop (3) (E) kPa not available
Hydraulic connections std inch 1/2
DF inch not available
Water content std dm3 1,8
DF dm3 not available
4.1 WEIGHTS