GATEXPERT SW400DC User manual

Swing Gate Opener
User Manual
SW400DC
Website: www.gatexpertstore.com
E-mail: sales@gatexpertstore.com

Instructions for SW400DC
www.gatexpertstore.com
WARRANTY
1. To repair against this warranty card and invoice during the warranty period.
2. Warranty period: 1 year after the date of invoice.
3. Without unauthorized dismantling, any product broken or damage due to
quality problem, we’ll offer the repair service for free or replace for free.
4. The malfunction and damages caused by incorrect use or man fault is not
covered by this warranty.
CONTACT US
E-mail: sales@gatexpertstore.com
Please fill in the order information in the form below.
All personal information you provided will be only used for warranty service
and kept strictly confidential.
Refer to this list when contacting GATEXPERT for technical service or
assistance with your automatic gate opener.
Order Number
Product Model
Purchase Date
Country / Region
Email Address
Issue Details

Instructions for SW400DC
www.gatexpertstore.com
CONTENTS
1. Safety Instruction........................................................................................................................1
2. Packing List..................................................................................................................................2
3. Technical Parameters............................................................................................................................... 3
4. Installation.................................................................................................................................... 4
4.1 Installation Drawing............................................................................................................................4
4.2 Size of Main Machine and Accessories.........................................................................................4
4.2.1 Size of Main Machine.................................................................................................................... 4
4.2.2 Size of Mounting Plate.................................................................................................................. 5
4.3 Installation Steps.................................................................................................................................5
4.3.1 Preparation before Main Machine Installation........................................................................... 5
4.3.2 Accessory Installation....................................................................................................................6
4.3.3 Main Machine Installation............................................................................................................. 7
4.3.4 Size of Control Box......................................................................................................................10
5. Wiring and Debugging....................................................................................................................... 11
5.1 Wiring Instructions............................................................................................................................11
5.2 Control Board Drawing and Instructions....................................................................................12
5.3 Digital Screen Setting...................................................................................................................... 13
5.4 Travel Setting..................................................................................................................................... 13
5.5 Trimmer Setting................................................................................................................................. 14
5.6 Learning Remote Control & Delete Remote Control............................................................... 14
5.6.1 Learning Remote Control............................................................................................................14
5.6.2 Delete Remote Control................................................................................................................14
5.6.3 Special Remote Control Key-button....................................................................................15
5.7 Control Board Settings....................................................................................................................15
5.7.1 Base Menu.................................................................................................................................... 15
5.7.2 Base Menu Instructions...............................................................................................................17
5.7.3 Advanced Menu............................................................................................................................19
5.7.4 Advanced Menu Instructions...................................................................................................... 21
6. Others.......................................................................................................................................... 22
6.1 Maintenance....................................................................................................................................... 22
6.2 Troubleshooting................................................................................................................................ 23

Instructions for SW400DC
www.gatexpertstore.com
1
Dear users,
Thank you for choosing this product. Please read the manual carefully before assembling
and using it. Please do not leave out the manual if you send this product to a third party.
1. Safety Instruction
● Please read this manual carefully before installation, in which involves with important
information about installation、using、maintenance and safety.
● Any undefined operations under this manual is not allowed, incorrect using may damage
the product even causing the injuries or property losses.
● To consider the possible danger during the installation or using process of swing gate
operator, installation must strictly comply with the construction standard and electrical
operating procedure.
● Before installation, please make sure that the power voltage being used matches with
the supply voltage of this product. Please check if the leakage protection switch is
installed and the grounding system is correct.
● Please check if additional equipments or materials are required to meet the specific
requirements.
● The disposal of packaging material must be complying with the local regulation.
● Please do not change any parts except for those defined under this manual. Any
undefined changes may cause the malfunction. Any damages to the product arising
therefrom shall be beyond the liability of the company.
● Please do not leak water or any liquid into the controller or any other open devices.
Please disconnect the power immediately if any mentioned cases happened.
● Please keep this product away from heat and open fire. Or it may damage the
components; cause the failure or other hazards.
● Please make sure there is no vehicles、passengers and objects passing through while
the swing gate is moving.
● Anti-clip equipment like infrared protection switch must be installed to avoid injuries to
person and property losses. The company shall not be liable for any damage or
accident arising therefrom.
● The installation、using and maintenance of this product must be carried out by
professionals.
● Children are not allowed be touch the control devices or remote transmitters.

Instructions for SW400DC
www.gatexpertstore.com
2
● A warning sign must be placed somewhere on the swing gate according to the national
standard.
● Please keep this instruction properly for future reference.
2. Packing List (Standard)
No.
Picture
Name
Quantity
1
Main machine
2
2
Control box
1
3
Manual release bar
1
4
Remote control
2
5
Wall bracket
4
6
Front mounting bracket
2
7
Connecting bracket
2
8
Mounting screw (short)
2
9
Mounting screw (long)
2
10
Screw M8×25
4
11
Nut M8
6
12
Limit stopper
1

Instructions for SW400DC
www.gatexpertstore.com
3
No.
Picture
Name
Quantity
13
Spring washer Ø12
2
14
gasket
2
Packing List (Optional)
No.
Picture
Name
Quantity
1
Infrared sensor
1
2
0
8
5 6
97
4
1 2 3
Wireless keypad
1
3
Alarm lamp
1
4
Electric lock
1
5
Storage battery
2
3. Technical Parameters
Model
SW400DC
Power supply
220V/50Hz;110V/60Hz
Motor power
62W
Gate moving speed
22~26s / 90°
Max.single-leaf weight
400kg
Max.single-leaf length
3m
Max.piston stroke
45cm
Max.force
3800N
Remote control distance
≥30m
Remote control mode
Single button mode
Storage battery (optional)
DC24V (4.5Ah or 9Ah)

Instructions for SW400DC
www.gatexpertstore.com
4
Noise
≤60dB
Working duty
S2, 30min
Recording of up remote controls
20
Remote frequency
433.92 MHz
Working temperature
-20°C - +70°C
Package weight
20kg
4. Installation
SW400DC swing gate opener is applicable to single leaf gate weight less than 400kg,
and the length shorter than 3m. The drive mode adopts the worm and worm gear to
combine the screw rod transmission. This gate opener must be installed inside the
enclosure or yard for protection.
4.1 Installation Drawing
0
8
5 6
97
4
1 2 3
⑦
①
③
④
⑤
②
⑧
⑥
Figure 1
①Control box ③Gate ⑤Infrared sensor (optional) ⑦
Remote control
②Gate opener ④Alarm lamp (optional) ⑥Limit stopper ⑧
Wireless keypad (optional)
4.2 Size of Main Machine and Accessories
4.2.1 Size of Main Machine

Instructions for SW400DC
www.gatexpertstore.com
5
1 4 5 0 m m
1 0 0 0 m m
1 0 6 m m
Figure 2
4.2.2 Size of Mounting Plate
F ro n t m o u n tin g b ra c k e t W a ll b ra c k e t
70mm
8.
5mm
17.5mm
40mm
2x8.
5mm
φ
Figure 3
4.3 Installation Steps
4.3.1 Preparation before Main Machine Installation
Before installing the door opener, please confirm that the door were installed
correctly, please ensure that the door can be manually operated smoothly, and the
door limit stopper can effectively prevent the door to continue moving.
Please keep a distance of 40-50mm between the door bottom and the ground for
installing the electric lock. If electric lock is not required, the distance between the
door bottom and the ground should be ≥20mm;
The recommended mounting height of the 2 main machines is around 300 ~
800mm above the ground, and make sure there are reliable fixed points for mounting
brackets.
Cable bury
In order to ensure the normal operation of the door opener and protect the cable
from damage, please use two PVC pipes to bury the motor and power cables, and the

Instructions for SW400DC
www.gatexpertstore.com
6
control cables separately. One PVC pipe for motor and power cables, the other one
for control cables.
Mounting brackets fixing
In order to install the SW400DC main machines firmly, it is recommended to use
the expansion screws to fix the mounting brackets.
4.3.2 Accessory Installation
a) Before installing the main machines, please install the wall bracket on the wall first,
then fix the connecting bracket, finally install the front mounting bracket on the door.
Note: Please detect by gradienter before fixing to ensure that the front
mounting bracket and the connecting bracket are in the same level.
Expansion screw Hexagon screw
Nut Nut
Hexagon screw
Nylon gasket
Figure 4
b) The connecting bracket and wall bracket can be connected according to different
conditions, please refer to figure 5.
Figure 5
c) Users should prepare power cables for the control box and the main machines by
themselves due to the different installation environment. The cores for the control box
power supply cable should be more than 3, the cores for the motor cable is 2. If users
need to install external accessories like electric lock, infrared sensor, alarm lamp,
external button switch etc., please increase the embedded cables accordingly, please
make sure the sectional diameter of electric lock cable is over 1.5mm², sectional

Instructions for SW400DC
www.gatexpertstore.com
7
diameter of other cables is over 0.5mm². The cable length should be determined by
users according to their installation situations.
Note: The outlet on the PVC pipe should be downward in order to avoid the rain
water flowing into the pipe along the cable.
d) Before the installation, please unlock the two main machines. Unlock method:
Remove the cover, insert the manual release bar, rotate the bar until it’s released, as
shown in Figure 6, then turn the telescopic arm, you’ll find it is stretched easily.
Left engine Right engine
Figure 6
4.3.3 Main Machine Installation
Please refer to Figure 7 to fix the tail of the main machine and the connecting bracket
with the installation screws, and then manually adjust the telescopic arm to the
appropriate length, finally fix the telescopic arm connector and the front mounting
bracket with the installation screws. Pull the door after installation to ensure the travel
is flexible without jamming.
Mounting screw (length)
Spring washer
Mounting screw (short)
Nut
gasket
Figure 7

Instructions for SW400DC
www.gatexpertstore.com
8
Installation direction: door opens inward
B
C
A
D
L
F
E
Note:Note: TheThe unlimitedunlimited versionversion
mustmust havehave a limitlimit stopperstopper
installedinstalled
ItIt isis recommendedrecommended toto installinstall withwith a
safetysafety stopperstopper (should(should bebe
preparedprepared byby thethe usersusers themselves)themselves)
Figure 8
A(mm)
B(mm)
C(mm)
D max
L(mm)
SIZE
240
115
15
100°
1400
220
125
25
100°
1440
200
135
35
100°
1420
180
145
45
90°
1420
Table 1 Recommended Installation Position

Instructions for SW400DC
www.gatexpertstore.com
9
Installation direction: door opens outward
L
A
B
FE
D
C
Note:Note: TheThe unlimitedunlimited versionversion
mustmust havehave a limitlimit stopperstopper
installedinstalled
ItIt isis recommendedrecommended toto installinstall withwith a
safetysafety stopperstopper (should(should bebe
preparedprepared byby thethe usersusers themselves)themselves)
Figure 9
A(mm)
B(mm)
C(mm)
D max
L(mm)
SIZE
170
170
40
90°
1000
180
170
30
100°
1000
190
170
30
100°
1000
200
180
40
100°
1000
Table 2 Recommended Installation Position
Note: Value B must be close or equal to the value A to reach the best
mechanical advantage.

Instructions for SW400DC
www.gatexpertstore.com
10
4.3.4 Size of Control Box
Control box without built-in battery Control box
with built-in battery
Figure 9
Warning
To ensure safety, please install the limit stopper at the close limit position
when the door opens inward (as shown in figure 8).
Before installing the main machine, please make sure the main machine and
components are in good mechanical performance and the door can be manually
operated flexibly.
One control unit can optionally drive one main machine or two main machines.
Earth leakage circuit breaker must be installed on where the gate movement can
be seen, and the minimum mounting height for the control box should be over
1.5m to avoid being touched by kids.
After installation, please check whether the mechanical property is good or not,
whether gate movement is flexible or not after unlocking, and whether the
infrared sensor (optional) is installed correctly and effectively.
2 1 0 m m
2 9 9 m m
1 3 3 m m
8 8 m m
2 9 9 m m
2 1 0 m m

Instructions for SW400DC
www.gatexpertstore.com
11
5.Wiring and Debugging
5.1 Wiring Instructions
MOTOR1MOTOR1
AC24VINAC24VIN
FORCEFORCE SLOWSLOW
PROGPROG +-SETSET
DOWNDOWN SPEEDSPEED
MOTOR2MOTOR2 -ELOCK+-ELOCK+ -BLK+-BLK+ 24V24V
+SOLAR-+SOLAR- +BATT-+BATT-
12V12V COMCOM COMCOM COMCOM OSCOSC GNDGND ANTANTPHPH PEDPEDEM1EM1 LM1LM1 EM2EM2
L
LM2LM2
M1M1 M2M2
Motor1Motor1
MainsMains
inputinput
FUSEFUSE 10A10A
24V24V batterybattery inputinput +
24V24V batterybattery inputinput -
SolarSolar powerpower inputinput -
SolarSolar powerpower inputinput +
Motor2Motor2
ElectricElectric LockLock
AlarmAlarm LampLamp
24V+24V+
12V+12V+
Motor1Motor1 LimitLimit signalsignal
CommonCommon
Motor1Motor1 LimitLimit powerpower supplysupply
Motor2Motor2 LimitLimit powerpower supplysupply
Motor2Motor2 LimitLimit signalsignal
GroundGround
AntennaAntenna
PhotoPhoto SensorSensor
SingleSingle ChannelChannel
SingleSingle GateGate
CommonCommon
Figure 11

Instructions for SW400DC
www.gatexpertstore.com
12
5.2 Control Board Drawing and Instructions
MOTOR1MOTOR1
AC24VINAC24VIN
FORCEFORCE SLOWSLOW
PROGPROG +-SETSET
DOWNDOWN SPEEDSPEED
MOTOR2MOTOR2 -ELOCK+-ELOCK+ -BLK+-BLK+ 24V24V
+SOLAR-+SOLAR- +BATT-+BATT-
12V12V COMCOM COMCOM COMCOM OSCOSC GNDGND ANTANTPHPH PEDPEDEM1EM1 LM1LM1 EM2EM2 LM2LM2
Figure 12
Terminal
Description
1. AC24VIN
24VAC Power Supply Input
2. +SOLAR-
Solar Power Input
3. +BATT-
24V Battery Input
4. FORCE
Resistance Force
5. SLOW DOWN
Slow Stop Distance
6. SPEED
Moving Speed
7. MOTOR1
Motor1 Output
8. MOTOR2
Motor2 Output
9. -ELOCK+
Electric Lock Output
10. -BLK+
Alarm Lamp Output (Note: pay
attention to the negative and positive.)
11. +24V
24V Output Positive
12. +12V
12V Output Positive (No output under
dormant state)
13. EM1
Motor1 Hall Sensor Power Output
14. LM1
Motor1 Hall Sensor Limit Signal Input
15. EM2
Motor2 Hall Sensor Power Output
16. LM2
Motor2 Hall Sensor Limit Signal Input
17. PH
Photo Sensor Input Active
18. PED
Single Gate/Pedestrian Mode Input
Active
19. OSC
Single Channel Input Active
20. ANT
Antenna

Instructions for SW400DC
www.gatexpertstore.com
13
21. COM
Common
5.3 Digital Screen Setting
When the control board is working, the users can check working state of gate opener
by digital screen on the control board.
: no input;
: under opening state;
: under closing state;
: error;
:manual mode;
: travel setting;
5.4 Travel Setting (VERY IMPORTANT)
In the first installation of gate openers, the installer need to set open and closed
limit switch positions for running the travel.
Fully open both sides of the gate and lock the clutch, and then press and hold the "-"
button on the control board until the digital screen shows "SU". After this step, the
gate will firstly run towards the closing direction and stop, and then the gate will
automatically open. When the two swing gates are fully open, the gates will
automatically close for the second time, and the travel setting will be completed when
the gates are closed. If the distance of starting slow speed of gate is not appropriate,
adjust the "SLOW DOWN " button to revise the distance.
Note:
If the gate suddenly stops during travel setting, please increase the resistance
force.
If the gate didn’t stop when meets the obstacles during travel setting, please
appropriately reduce the resistance force.

Instructions for SW400DC
www.gatexpertstore.com
14
Installer must redo travel setting after modifying the "SPEED" trimmer.
5.5 Trimmers Setting
Obstacle Sensibility Trimmer
To adjust the sensitivity of obstacle -- clockwise to increase, counterclockwise to
reduce the sensitivity of obstacle. If there are environmental effects, such as heavy
winds, adjust the trimmer according to environment.
Slow Speed Distance Trimmer
To adjust slow speed distance -- clockwise to increase, counterclockwise to decrease
slow speed distance. Please do not set very short slow speed distance, to avoid the
gate collision.
Gate Moving Speed Trimmer
To adjust gate moving speed -- clockwise to accelerate, counterclockwise to slow
down. The trimmer can be adjusted to change the opening and closing travel time.
This adjustment must be finished before travel setting.
Figure 13
5.6 Learning Remote Control & Delete Remote Control
5.6.1 Learning Remote Control
Press and hold "+" button, the alarm light will keep flashing, and digital screen
displays remote control mode -- “PO” -- two swing gates single channel mode; “Pd" --
single gate four channel mode; Press the button of the remote control to be learned,
the digital screen will show the number of current learned remote control, then the
remote control learning is completed. (The default of new paired remote control is two
swing gates single channel mode).
5.6.2 Delete Remote Control
Enter into “AE” in the digital screen and then to choose “rE” to delete the remote
controls.
Counterclock
wise
reduce
FORCE
Obstacle Sensibility
Trimmer
Clockwise
Increase
SLOW DOWN
Slow Speed Distance
Trimmer
SPEED
Gate Moving Speed
Trimmer
Counterclock
wise
reduce
Clockwis
Counterclockw
ise
Clockwis

Instructions for SW400DC
www.gatexpertstore.com
15
Figure 14
5.6.3 Special Remote Control Key-button
Press and hold the combination keys for 5S.
C(stop)+D(single gate) combination key -- enter into remote control learning.
5.7 Control Board Settings
5.7.1 Base Menu
Press "PROG" to enter into base menu;
Digital screen shows “NE”, select other functions of this menu by “+” and “-” buttons.
Press "SET" to confirm or to enter into sub-menu.
To exit menu, press "PROG".
If no command for one minute, the menu will automatically exit.
Base Menu
Automatic closing
mode
Standard mode
Open/Close/Stop
Dual gates
mode
To switch
single gate
mode/dual
gates mode
Single gate
mode
Community
mode
Open gate
time interval
3 seconds
(default)
To select
working
mode
Initial

Instructions for SW400DC
www.gatexpertstore.com
16
15 seconds
(default)
Automati
c closing
time
Remote
control
mode
Dual gates
single channel
mode
Four channel
Single gate
single channel
Delete
remote

Instructions for SW400DC
www.gatexpertstore.com
17
5.7.2 Base Menu Instruction
Menu
Press "PROG" to
enter into base menu.
Option
Press “+”(up) or “-”(down) to select;
Press “SET” to confirm.
Default/Attention
Working Mode
Standard mode; O/C/S
(Open/Close/Stop).
O/S/C standard mode with
automatic closing function. When the
gate opens, it will automatically close
after automatic closing time. If a “close
the gate” command is sent during the
automatic closing time waiting time, the
automatic closing function will be
canceled.
Community mode(with
automatic closing function). When the
gate opens, any gate command will not
be responded until it closes
automatically. If user sends gate
command during the closing process,
then the gate will reopen. If a gate
command is sent during the automatic
closing waiting time, this waiting time
will be recalculated. If the gate is not
closed completely for more than three
consecutive times, the automatic
closing function will be canceled and
the gate will be closed by re-sending the
gate closing command. Note that in
community mode, the gate still has the
automatic closing function in case of
meeting obstacles.
Standard
mode; O/C/S
(Open/Close/Stop).
Table of contents
Other GATEXPERT Gate Opener manuals

GATEXPERT
GATEXPERT SL500DCL User manual

GATEXPERT
GATEXPERT GT1000DCL User manual

GATEXPERT
GATEXPERT GT800ACL User manual

GATEXPERT
GATEXPERT GK Series User manual

GATEXPERT
GATEXPERT SW200DC User manual

GATEXPERT
GATEXPERT PY300DC User manual

GATEXPERT
GATEXPERT PY1200AC User manual

GATEXPERT
GATEXPERT SL500DC User manual

GATEXPERT
GATEXPERT GT1000DC User manual

GATEXPERT
GATEXPERT GA600AC User manual
Popular Gate Opener manuals by other brands

Benninca
Benninca RI.524K Operating instructions and spare parts catalogue

BFT
BFT WIND AC A230/240-76 EF Installation and ajustament instructions

tau
tau R18 series Use and maintenance manual

On Automation
On Automation ATLAS SWA300 instruction manual

Nice
Nice HOPP HO7124 instructions

FAAC
FAAC FSL700 manual