GATEXPERT PY300DCL User manual

Sliding Gate Opener
User Manual
PY300DCL
Website: www.gatexpertstore.com
E-mail: sales@gatexpertstore.com

Instructions for PY300DCL
www.gatexpertstore.com
WARNING
Instructions must be read before installation. Please follow these instructions carefully,
incorrect installation could affect gate operation.
When mounting and positioning this product please ensure the power cable is
unplugged.
The motor cover will need to be removed to mount the motor to the mounting plate or
directly to the concrete footing.
Any changes to the settings on this product can only be made by a licensed electrician.
This product is only powered by AC110V power supplyor backup battery power and
solar power.

Instructions for PY300DCL
www.gatexpertstore.com
WARRANTY
1. To repair against this warranty card and invoice during the warranty period.
2. Warranty period: 1 year after the date of invoice.
3. Without unauthorized dismantling, any product broken or damage due to quality problem,
we’ll offer the repair service for free or replace for free.
4. The malfunction and damages caused by incorrect use or man fault is not covered by this
warranty.
CONTACT US
E-mail: sales@gatexpertstore.com
Please fill in the order information in the form below.
All personal information you provided will be only used for warranty service and kept
strictly confidential.
Refer to this list when contacting GATEXPERT for technical service or assistance with
your automatic gate opener.
Order Number
Product Model
Purchase Date
Country / Region
Email Address
Issue Details

Instructions for PY300DCL
www.gatexpertstore.com
CONTENTS
Default Setting Instruction..............................................................................................................1
Safety Instruction.............................................................................................................................2
Parts List...........................................................................................................................................3
Technical Parameters......................................................................................................................5
Installation........................................................................................................................................5
Before You Start..........................................................................................................................5
Tools Required / Example Sliding Gate………............................................................................5
Step 1 - Gate Preparation............................................................................................................6
Step 2 - Checking Manual Release.............................................................................................6
Step 3 - Removing / Installing Motor Cover.................................................................................7
Step 4 – Motor Pad Footing.........................................................................................................8
Step 5 - Fitting Mounting Base and Motor....................................................................................8
Step 6 - Sprocket and Chain & Motor Alignment.......................................................................10
Step 7 - Powering on........................……..................................................................................11
Step 8 - Testing Travel and Limit Stops.....................................................................................12
Programming and Wiring..............................................................................................................13
Terminal Instructions.................................................................................................................14
Wiring to the Terminal...............................................................................................................15
Wiring to the Transformer..........................................................................................................15
Connecting Infrared Photocells.................................................................................................17
Remote Control Operation........................................................................................................19
Connecting Storage Battery......................................................................................................20
Connecting Solar Panel.............................................................................................................21
Maintenance...................................................................................................................................21
Troubleshooting.............................................................................................................................22
Drawing and Measurements..........................................................................................................23

Instructions for PY300DCL
www.gatexpertstore.com
1
Then the gate will move in
the set direction.
Default Setting Instruction
The gate opener will open the gate to the right-hand side as its default setting. By default, the
opener mounts on the right-hand side. (Figure 1)
Gate in closed position Gate in open position
Figure 1
Before installation: Test the gate opener by plugging it into a power source and pressing the
remote. Press the opening button, the output sprocket rotates, then press the stop button, the
output sprocket stops rotating. Finally, press the closing button, the output sprocket rotates to the
opposite direction. This will give you an understanding of the way how the opener moves the gate.
Figure 2
Note: Ensure that the gate opener is unplugged before proceeding with installation. Please keep
fingers away from the motor output sprocket whilst it is turning.
If your gate needs to open from the other direction (to the left, refer to figure 3), your opener needs
to be mounted on the left-hand side as shown, the relative wires need to be swapped over, please
check under “Terminal Instructions” for swapping. (Factory default setting is for right-hand opening:
opener mounted on the right-hand side).
Figure 3
Any works done to the gate opener must be completed whilst the power is off, and the opener is
unplugged.
Press the first/top button
on the remote.
Rotating output sprocket will
drive the gate frame.

Instructions for PY300DCL
www.gatexpertstore.com
2
Safety Instruction
Warning: Incorrect or improper use of this product can cause damage to persons, animals or
properties.
·Please ensure that the input voltage used matches with the supply voltage of gate opener.
·All modifications to wiring or electrics, and any adjustment or maintenance to input voltage
must be done by a qualified electrician.
·All potential hazards and exposed pinch points of the gate must be eliminated or guarded prior
to installation of this gate opener.
·Never mount any device that operates the gate opener where the user can reach over (under,
around or through) the gate to operate the controls. These must be placed away from any
moving range of the moving gate.
·Ensure power plug is disconnected from the power socket during installation or maintenance.
·Keep remote control and other control devices out of children’s reach, in order to avoid
unintentional activation.
·To ensure safety, before installing the motor, mount a Gate End Catch and a Gate Stop at each
end of the rail to prevent the gate travelling off the track.
·If required, install infrared photocell to detect obstructions and prevent injury to person or
damage to property.
·Instruct all users about the control systems provided and the manual opening operation in case
of emergency.
·Ensure that the power cable is connected to a RCD protected weatherproof power outlet
installed by a qualified electrician.
·Do not install this product in an explosive atmosphere or where there is any danger of flooding.
·This product was exclusively designed and manufactured for the use specified in the present
documentation. Any other use not specified in this documentation could damage the product
and be dangerous.
·Only use original parts for any maintenance or repair operation. Our company declines all
responsibility with respect to the automation safety and correct operation when other supplier’s
components are used.
·Do not modify the automation components, unless explicitly authorized by our company.
·The user must avoid any attempt to carry out any works or repairs on this product, and should
always request the assistance of qualified personnel.
·This product is suitable for use on one sliding gate only.
·Anything which is not expressly provided for in these instructions is not allowed and will void
warranty.
·Dispose of all packing materials (plastic, cardboard, polystyrene etc.) according to current
guidelines. Keep plastic bags and polystyrene out of children’s reach.
·Save these instructions for future use.

Instructions for PY300DCL
www.gatexpertstore.com
3
Parts List
Parts List (standard configuration)
No.
Picture
Name
Quantity
1
Motor
1
2
Manual Release Keys
2
3
Manual Release Bar
1
4
Remote Controls
2
5
Mounting Accessories Box
1
5-1
Sprocket Cover
1
5-2
Chain(Including 2 Chain Links)
6m
5-3
Tie Rod
2
5-4
Square Screw
4
5-5
Round Screw
4
5-6
Door Connecting Plate
2
5-7
Horizontal Mounting Plate
1

Instructions for PY300DCL
www.gatexpertstore.com
4
No.
Picture
Name
Quantity
5-8
Vertical Mounting Plate
2
5-9
Anchor Bolts M8
4
5-10
Inner Hexagon Head Bolt M6X20
4
5-11
Hexagon Head Bolt M8X40
4
5-12
Nut M6
12
Nut M8
16
5-13
Flat Washer φ6
12
Flat Washer φ8
16
5-14
Spring Washers φ6
12
Spring Washers φ8
12
Note: Extra flat washers and spring washers are spare parts.
Parts List (optional)
No.
Picture
Name
Quantity
1
Infrared Photocell
1
2
Wireless Keypad
1
3
Alarm Lamp
1
Additional remote controls: Spare/Additional remotes for the automatic gate kit, these will need to
be paired to the motor.
Infrared photocell: Detects pedestrians, vehicles and objects that cross an infrared beam and
prevents the gate from closing.
Wireless keypad: Allows secure access through the gate used with a user set code.
Wired control: Allow users to control the opening and closing of the door through an external
push-button.
Alarm lamp: Alerts people near the gate and users that the gate is in operation.

Instructions for PY300DCL
www.gatexpertstore.com
5
Technical Parameters
Model
PY300DCL
Power Supply
110VAC/60Hz
Motor Power
100W
Gate Moving Speed
13m/min
Maximum Loading Weight
300KG
Remote Control Distance
≥30m
Remote Control Mode
Single button mode
Limit Switch
Electronic limit switch
Working Noise
≤60dB
Working Duty
S2, 20min
Recording of up Remote Controls
20
Remote Frequency
433.92 MHz
Working Temperature
-20°C - +70°C
Battery Specification
12V 4.5Ah*2pcs
Package Weight
18.94KG
Installation
Before You Start
·PY300DCL Sliding Gate Automation Kit is suitable for powering the opening and
closing motion of gates up to 300kg in weight, up to a length of 12m. (Standard kit contains a
6m chain, if the gate length is over 5.5m, please consider to extend the length of the chain.)
·Gate motion is achieved by the rotating output sprocket of the gate opener driving the chain
fitted to the moving gate.
·The gate opener requires you to press the remote control once to open, and once again to
close. This is a safety feature to ensure safe operation.
·The gate opener itself must be fitted within private property, never externally to a property’s
boundary.
Any works done to the gate opener must be completed whilst the power is off and the opener is
unplugged. Any modifications/alterations/works to AC power components must only be completed by
a licensed electrician.
Tools Required
·Tape measure
·Level
·12mm concrete drill and hammer (when uses expansion screws)
·Phillips head screwdriver
·Straight screwdriver

Instructions for PY300DCL
www.gatexpertstore.com
6
Example Sliding Gate
Gate Track and Track Wheels Gate End Catch Gate Guide Rollers Gate Stop
Figure 4
Please ensure that the gate opener power cable is not plugged in at any stage before Step 7.
Step 1 - Gate Preparation
·Ensure that the sliding gate is correctly installed.
·The gate is horizontal and level and the gate can glide back and forth smoothly when moved by
hand before installing the gate opener.
·Wheels and guide rollers should rotate easily and be free from dirt or grime.
·Track should be flat, level and firmly affixed.
·Any misalignment in the gate will affect performance of the automatic gate opener.
The gate should slide smoothly by hand before attempting to install the gate opener.
Figure 5
Step 2 - Checking Manual Release
·Insert the key and open the manual release bar to enable the motor get into manual mode and
check that the motor output sprocket rotates freely by hand (Figure 6).

Instructions for PY300DCL
www.gatexpertstore.com
7
Figure 6
Step 3 - Removing / Installing Motor Cover
·Unscrew the two cover screws located at each side of the motor cover.
·Remove the rubber grommet below the limit switch (Figure 7).
Figure 7
·Sprocket cover installation as Figure 8
Figure 8
To make the motor into manual mode, insert the key
and open the manual release bar as shown.
In manual mode, the sprocket can turn
freely and the gate can be operated by
hand.
Bolts
Sprocket Cover
open the manual
release bar

Instructions for PY300DCL
www.gatexpertstore.com
8
Step 4 - Motor Pad Footing
·The motor pad concrete footing requires an area of no less than 500mm long x 350mm wide
and a minimum depth of 200mm (Standard requirement).
·Ensure surface is level and parallel to the driveway.
Mounting Base Dimensions
Figure 9
Step 5 - Fitting Mounting Base and Motor
·Fit anchor bolts(included in kit) or expansion bolts(should be prepared by users) according to
holes in mounting base (as per Figure 9).
·Position the mounting base and fix it as per Figure 10.
·Bolt motor to its base using the M8x40 bolts with spring and flat washers provided and tighten
as required.
Figure 10

Instructions for PY300DCL
www.gatexpertstore.com
9
Figure 11
Fitting Motor
·Fit motor and mounting base on the concrete footing.
·Ensure the motor output sprocket and chain are correctly aligned. Sprocket and chain should
be centered as much as possible.
·Take the motor away from mounting base.
·Leave a space of 30cm from the motor to end of the chain.
Nut
Flat Washer
Spring Washer
Nut
Sliding Gate Frame (in open position)
Use pencil, chalk or similar tools to
mark at the corners of mounting
plate
Flat Washer

Instructions for PY300DCL
www.gatexpertstore.com
10
Figure 12
Step 6 - Sprocket and Chain & Motor Alignment
·Ensure output sprocket and chain are correctly aligned. Under no circumstances should the
gate opener output sprocket carry any weight of the gate. It is the task of the gate castors or
wheels to carry the weight of the gate.
·If the gate doesn’t slide freely by hand, adjust the height of the chain accordingly until the full
length of gate slides freely by hand.
·Ensure the chain is in proper tightness after installation. (refer to Figure 13)
Figure 13

Instructions for PY300DCL
www.gatexpertstore.com
11
Figure 14
Open Position
Step 7 - Powering on
·Ensure that the outer cover has been fitted and fastened back onto the motor base.
·Before powering up the gate opener make sure the gate can travel by hand in manual mode
(key unlocked).
·Slide the gate to between the middle of the posts, approximately (see below diagrams).
·Lock the manual release spanner (key locked) in readiness for automatic mode.
·Plug the power cord into an approved RCD protected weatherproof outlet.
·Remote controls included in this kit are factory paired ready for use.
Sprocket
Chain
Cover
Chain
Sprocket

Instructions for PY300DCL
www.gatexpertstore.com
12
Figure 15
Step 8 - Testing Travel and Limit Stops
·Ensure gate opener is installed as per step 5, 6 and the sliding gate is in the middle position.
·Please refer to control board setting(page 15) to set the open limit stop position and closed limit
stop position. The ideal closed final position for the gate frame is 10-15mm from closed gate
end catch.
·After setting up the limit stop positions, the sliding gate will automatically run to open limit stop
positon and then to the closed limit stop postion, do not cut off the power supply or stop the
gate during it’s Auto-running.
·Press remote (remotes included in kit are factory paired to the motor) or exteral push button,the
sliding gate will begin to move. When it arriaves at the limit stop position the sliding gate will
stop.
Now the basic open and closed positions are set, for further setting functions and adjusting
parameters, please refer to pages 13-21 in this manual.
Open Limit Stop Position
Closed Limit Stop Position

Instructions for PY300DCL
www.gatexpertstore.com
13
J3 Terminal
J4 Terminal
J2 Terminal
Transformer
Secondary
(AC24V/3.3A)
Programming and Wiring
Any works to the 110V/220V AC must only be performed by a licensed electrician.
Ensure power is off before any modifications are made.
DC Motor
Solar Panel and
Storage Battery
Hall Sensor
Figure 17

Instructions for PY300DCL
www.gatexpertstore.com
14
Terminal Instructions
All changes to these settings below must be completed by licensed electrician.
Terminal DC Motor: Black connect to “T1”, red connect to “T2”, if the running
direction is opposite, please exchange “T1” and “T2”.
J4 Terminal:
Terminal LAMP+: Alarm Lamp +24VDC
Terminal LAMP-: Alarm Lamp -24VDC
J3 Terminal:
Terminal GND: Common Terminal for Photocell
Terminal PE: Photocell Input (N.C.).
Terminal +24: Additional Accessories +24VDC
Additional accessories sold separately.
J2 Terminal:
Terminal OSC: Single Cycle for External Push Button
(open/stop/close)
Terminal COM: Common Terminal for External Push Button.
Terminal OPEN: External Open Push Button Switch.
Terminal STOP: External Stop Push Button Switch.
Terminal CLOSE: External Close Push Button Switch.

Instructions for PY300DCL
www.gatexpertstore.com
15
Insert the wire into the
number on the terminal that
you are looking to connect to.
Refer to Page 13.
Tighten with a screwdriver
to secure the wire in place.
Wiring to the Terminal
Wiring to the Transformer
Figure 18
Using a screwdriver to
loosen the screw on the
side of the terminal.
Transformer Input 220VAC
Transformer
output 24VAC

Instructions for PY300DCL
www.gatexpertstore.com
16
Setting the Open and Closed Position
1. Press and hold SET until digital dispalys “1”.
2. Press and hold OPEN until gate opens to a proper open position(The open position will
be determined by customer themselves. Note: Press OPEN, the gate will open, if it’s not
opening, please change the motor wire “T1” and “T2”)
3. Press SET to confirm the open position, the digital will dispaly “2”.
4. Press and hold CLOSE until gate closes to a proper closed position.(The closed position
will be determined by customer themselves.)
5. Press SET to confirm the closed position.
Figure 19
Adjusting the Auto-close Time:
1. Press and hold OPEN until digital display “—”.
2. Press OPEN to add the time for Auto-close, press CLOSE to reduce the time.
3. If the time setting is 0, there will be no Auto-close function.
4. Press SET to confirm.
5. The number increase by 1, the time will add by 10 seconds.
Note: The Auto-close function will work only after the sliding gate runs to open
position.
Table of contents
Other GATEXPERT Gate Opener manuals

GATEXPERT
GATEXPERT GA600AC User manual

GATEXPERT
GATEXPERT DKC500ACL User manual

GATEXPERT
GATEXPERT GT1000DC User manual

GATEXPERT
GATEXPERT SL500DC User manual

GATEXPERT
GATEXPERT GK Series User manual

GATEXPERT
GATEXPERT GA500DC User manual

GATEXPERT
GATEXPERT GT800ACL User manual

GATEXPERT
GATEXPERT GA1000AC User manual

GATEXPERT
GATEXPERT PY1200AC User manual

GATEXPERT
GATEXPERT SW400DC User manual