manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GE
  6. •
  7. Air Conditioner
  8. •
  9. GE AJEQ09DCD User manual

GE AJEQ09DCD User manual

Other manuals for AJEQ09DCD

1

Other GE Air Conditioner manuals

GE AJCM10ACD User manual

GE

GE AJCM10ACD User manual

GE AEM08 Series Operating instructions

GE

GE AEM08 Series Operating instructions

GE AVP12 User manual

GE

GE AVP12 User manual

GE AEH14 Operating instructions

GE

GE AEH14 Operating instructions

GE AKM06LN User instructions

GE

GE AKM06LN User instructions

GE Zoneline 2500 Operating instructions

GE

GE Zoneline 2500 Operating instructions

GE ASTD5 and Operating instructions

GE

GE ASTD5 and Operating instructions

GE AEE12DN Manual

GE

GE AEE12DN Manual

GE APEW50 User manual

GE

GE APEW50 User manual

GE AEQ24DL User instructions

GE

GE AEQ24DL User instructions

GE AGM12 Operating instructions

GE

GE AGM12 Operating instructions

GE AEW10A Operating instructions

GE

GE AEW10A Operating instructions

GE AEW10AN Operating instructions

GE

GE AEW10AN Operating instructions

GE AJCS10DCB Assembly instructions

GE

GE AJCS10DCB Assembly instructions

GE AJCQ06LCH Original instructions

GE

GE AJCQ06LCH Original instructions

GE AHV05LP Original instructions

GE

GE AHV05LP Original instructions

GE AEW05 Operating instructions

GE

GE AEW05 Operating instructions

GE AEE18DN Manual

GE

GE AEE18DN Manual

GE AGW12 Operating instructions

GE

GE AGW12 Operating instructions

GE AJEQ12DCD User manual

GE

GE AJEQ12DCD User manual

GE AKQ24DN User instructions

GE

GE AKQ24DN User instructions

GE AGL05 User manual

GE

GE AGL05 User manual

GE AKW18 Series Operating instructions

GE

GE AKW18 Series Operating instructions

GE AEW10 Series Operating instructions

GE

GE AEW10 Series Operating instructions

Popular Air Conditioner manuals by other brands

Fujitsu ASYG 09 LLCA installation manual

Fujitsu

Fujitsu ASYG 09 LLCA installation manual

York HVHC 07-12DS Installation & owner's manual

York

York HVHC 07-12DS Installation & owner's manual

Carrier Fan Coil 42B Installation, operation and maintenance manual

Carrier

Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity IDUFCI60KC-3 installation manual

intensity

intensity IDUFCI60KC-3 installation manual

Frigidaire FAC064K7A2 Factory parts catalog

Frigidaire

Frigidaire FAC064K7A2 Factory parts catalog

Sanyo KS2432 instruction manual

Sanyo

Sanyo KS2432 instruction manual

LG MultiV Series installation manual

LG

LG MultiV Series installation manual

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

CLIMAVENETA

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea EWK06CW5 user manual

Midea

Midea EWK06CW5 user manual

Pioneer FAB Series installation manual

Pioneer

Pioneer FAB Series installation manual

SPT WA-1511S user manual

SPT

SPT WA-1511S user manual

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Mitsubishi Electric

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic CS-S18HKQ Service manual

Panasonic

Panasonic CS-S18HKQ Service manual

Panasonic CS-E15NKE3 operating instructions

Panasonic

Panasonic CS-E15NKE3 operating instructions

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Friedrich ZoneAire Compact P08SA owner's manual

Friedrich

Friedrich ZoneAire Compact P08SA owner's manual

Daikin R32 Split Series installation manual

Daikin

Daikin R32 Split Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
AJEQ09DCD
GE®230/208 Volt Window/Wall Mount Heat and Cool Unit
Wall Case Dimensions and Installation Information (in inches)
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
Specification Created 9/09 390364
Note: When installing slide-out chassis units in through-the-wall
applications, keep louvers free. Do not restrict air flow areas.
230/208V
20 Amp
Perpendicular
AJCQ12DCD
Premium, Deluxe and Value Model
Wall Case Dimensions (in inches)
Note: When installing units in through-the-wall applications.
Do not restrict air flow areas.
15-5/8
26
16-7/8
Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
AJEQ09DCD
GE®230/208 Volt Window/Wall Mount Heat and Cool Unit
Wall Case Dimensions and Installation Information (in inches)
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
Specification Created 9/09 390364
Installation Information: A finished opening of 26-1/8" x 15-3/4"
clear of intrusions is required. Keep clearance of 4" from side
walls. Brick veneer or frame walls should have wood studding
surrounding case to provide firm anchoring with screws. Case
can be fastened directly to brick or block walls with screws sunk
in lead expansion shields.
Note: Units should be caulked on all four sides of case to the
building exterior to assure building integrity.
Two Wall Cases for Tenant Option Installation
When the air conditioner is offered as a tenant option, these
wall cases provide protection against outside elements.
RAB47 – includes wall case, exterior grille and steel
closure panels.
RAB48 – includes wall case, exterior grille, steel closure panel
and two layers of insulation.
Standard Wall Case RAB46
Solid-sided wall case fabricated of galvanized steel with
baked enamel finish. Welded areas are coated with a sealing
compound to help resist rust and corrosion. Polymer gasket
surrounds opening to assure tight weather seal. Aluminum grille
(RAG13) is included. Panels on interior and between case and
grille provide weather protection prior to installation of chassis.
Provide firm anchoring with screws. Case can be fastened
directly to brick or block walls with screws sunk in lead
expansion shields.
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
AJEQ09DCD
GE®230/208 Volt Window/Wall Mount Heat and Cool Unit
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
Specification Created 9/09 390364
Features and Benefits
• R-410A Refrigerant
• 8,900/8,700 Cooling BTU
• 11,600/9,500 Heating BTU
• 9.4/9.4 EER
• 230/208 Volts
• Electronic controls with remote
• Electronic digital thermostat
• Four-way air direction
• Up-front, washable air filter
• 2 cool/2 heat/2 fan only speeds
• Remote thermostat capable
• Unit dimensions: 14-7/8"W x 24-3/4"H x 19-7/8"D
• Model AJEQ09DCD – Soft Gray
AJEQ12DCD