Auxiliary Controls onyourZoneline. .cEAp ,ia,oos.oom
Auxiliary Controls- Dip Switches
The au_liary dip switch controls are located
behind the room cabinet, through an opening
in the control panel.
Remove the room cabinet. See the ToRemovethe
RoomCabinetsection,
The ti_ctox) settings will be in the DOWNposition.
The owner is responsible for checking switches
and ensuring the) are in the desired position.
DipSwitches
ALLFR(All Electric Heat)--
(3500Series models only)
C:FAN CN(Cooling-Smart Fan)
H:FAN CY(Heating-Smart Fan)
CLASS2 (RemoteThermostat)
LOADSHEDDING(CDC)
FREEZSen (FreezeSentinel)
CONSTFAN(Constant ON Fan)
OCCUPIED(OccupancySensor)
J_og_N
T'_[_--TL1 (H)(Temp.Limit 1-Heat)
TL2(H)(Temp.Limit 2-Heat)
TL3(H)(Temp.Limit 3-Heat)
TL1(C)(Temp.Limit 1-Cool)
TL2(C)(Temp.Limit 2-Cool)
TL3(C)(Temp.Limit 3-Cool)
All ElectricHeat
This electric heat option flmcfions only on the
3500 Series models. X,_hen this switch is enabled
(UP), heat ptunp operation is locked out, causin,*,
the unit to provide only electric resistance heat.
°°"'EmBBBBBBB][BBBBBB]° "
L ALLI_R(All Electric Heat)
Cooling-Smart Fan
_._]_en this switch is enabled (UP), it allows the
indoor lira to cycle on/off with the compressor
_._]_en this switch is disabled (DOWN),it allows
the indoor lira to run continuously.
oo : aaaaBailaaaaaaloo':
L C: FAN CN (Cooling-Smart Fan)
Heating-Smart Fan
\,_l_en this switch is enabled (UP), it allows the
indoor tim to run confinuousl); When this
switch is disabled (DOWN),it allows the indoor
lira to cycle on/off with the heat pump or
heater oper;ition.
° :'[BBCBBBBB]IBBBBBBI
L H: FANCY(Heating-Smart Fan)