manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GE
  6. •
  7. Measuring Instrument
  8. •
  9. GE PACE 1000 Instruction Manual

GE PACE 1000 Instruction Manual

Other GE Measuring Instrument manuals

GE Multilin PQM User manual

GE

GE Multilin PQM User manual

GE Protimeter MMS2 User manual

GE

GE Protimeter MMS2 User manual

GE Moisture Image 1 Series Owner's manual

GE

GE Moisture Image 1 Series Owner's manual

GE moisture.IQ User manual

GE

GE moisture.IQ User manual

GE Druck DPI 705 User manual

GE

GE Druck DPI 705 User manual

GE DigitalFlow GF868 Owner's manual

GE

GE DigitalFlow GF868 Owner's manual

GE RHM 40 User manual

GE

GE RHM 40 User manual

GE PanaFlow HT User manual

GE

GE PanaFlow HT User manual

GE CTF878 Troubleshooting guide

GE

GE CTF878 Troubleshooting guide

GE Multilin DDFR User manual

GE

GE Multilin DDFR User manual

GE DewPro MMY 245 User manual

GE

GE DewPro MMY 245 User manual

GE MAC 800 User manual

GE

GE MAC 800 User manual

GE DigitalFlow DF868 Owner's manual

GE

GE DigitalFlow DF868 Owner's manual

GE SCOUT100-Ex User manual

GE

GE SCOUT100-Ex User manual

GE Power Quality Meter Series User manual

GE

GE Power Quality Meter Series User manual

GE Precision 500D User manual

GE

GE Precision 500D User manual

GE DigitalFlow GF868 User guide

GE

GE DigitalFlow GF868 User guide

GE RHM 80 User manual

GE

GE RHM 80 User manual

GE N60 User manual

GE

GE N60 User manual

GE MAC 600 User manual

GE

GE MAC 600 User manual

GE Sievers 500 RL User manual

GE

GE Sievers 500 RL User manual

GE DINAMAP ProCare User manual

GE

GE DINAMAP ProCare User manual

GE PanaFlow MV80 User manual

GE

GE PanaFlow MV80 User manual

GE Ultrasonic USM Go User manual

GE

GE Ultrasonic USM Go User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

K0467 Issue No. 4 1
GE
Measurement & Control
Pressure Automated Calibration Equipment
Safety Instructions and User Guide - K0467
PACE Pressure Indicators
2 K0467 Issue No. 4
Figure 1
A Single port instrument B Two port instrument C Three port instrument
D Remote sensor instrument
1 Power supply connector 2 Electrical rating 3 Pressure port
4 Pressure port 5 Maximum working pressure 6 Pressure full-scale (range)
7 Power supply adaptor (see packaging list)
1
5
6
2
3
4
A
B
C7
22V to 26V22V to 26V
22V to 26V22V to 26V
XXXX XXXX XX
ANALOGUE 1
CONSULT HANDBOOK
CONSULT HANDBOOK
22V to 26V22V to 26V
ANALOGUE 1
CONSULT HANDBOOK
D
22V to 26V22V to 26V
ANALOGUE 1 VFC 1
15
CONSULT HANDBOOK
K0467 Issue No. 4 3
1 Introduction
The PACE Pressure Indicator measures both pneumatic and hydraulic pressures and displays, on
a colour touch-screen, the measured pressure and instrument status. The touch-screen enables
selections and settings in measuring modes. The instrument can be operated remotely through
communication interfaces.
1.1 Safety
The manufacturer has designed this equipment to be safe when operated using the
procedures detailed in this manual. Do not use this equipment for any other purpose
than that stated, the protection provided by the equipment may be impaired.
This publication contains operating and safety instructions that must be followed to
make sure of safe operation and to maintain the equipment in a safe condition. The
safety instructions are either warnings or cautions issued to protect the user and the
equipment from injury or damage.
Use qualified * technicians and good engineering practice for all procedures in this
publication.
1.2 Pressure
Do not apply pressures greater than the maximum working pressure to the equipment.
1.3 Toxic Materials
There are no known toxic materials used in construction of this equipment.
1.4 Maintenance
The equipment must be maintained using the procedures in this publication. Further
manufacturer’s procedures should be done by an authorized service agents or the
manufacturer’s service departments.
1.5 Technical advice
For technical advice contact the manufacturer.
* A qualified technician must have the necessary technical knowledge, documentation,
special test equipment and tools to carry out the required work on this equipment.
1.6 General Specification
Display LCD: Colour display with touch-screen
Operating temperature 10°C to 50°C (50° to 122°F)
Storage temperature -20°C to 70°C (-4° to 158°F)
Ingress protection IP20 (EN60529)
Operating humidity 5% to 95% RH (non-condensing)
Vibration MIL-PRF-28800 Type 2 class 5 style E/F
Operating altitude Maximum 2000 metres (6560ft)
EMC EN 61326
Electrical safety EN 61010-1, UL61010-1, CSA 22.2, No. 61010-1 and IEC61010-1
Power adaptor Input range: 100 - 240VAC, 50 to 60Hz, 700mA. Installation category
II
Pressure safety Pressure Equipment Directive - class: sound engineering practice
(SEP) for group 2 fluids.
Pollution degree 2
Operating Environment Indoor use only. Not rated for use in potential explosive
atmospheres
4 K0467 Issue No. 4
1.7 Symbols
The equipment contains the following symbols to identify hazards.
This equipment meets the requirements of all relevant European safety
directives. The equipment carries the CE mark.
This symbol, on the instrument, indicates that the user should refer to the
user manual. This symbol, in this manual, indicates a hazardous
operation.
Ce symbole, sur l’instrument, indique que l’utilisateur doit consulter le
manuel d’utilisation. Ce symbole, dans le manuel, indique une situation
dangereuse.
This symbol, on the instrument, indicates do not throw-away in domestic
bin, hazardous material, dispose correctly in accordance with local
regulations.
WARNINGS
TURN OFF THE SOURCE PRESSURE(S) AND CAREFULLY VENT THE PRESSURE LINES
BEFORE DISCONNECTING OR CONNECTING THE PRESSURE LINES. PROCEED WITH
CARE.
ONLY USE EQUIPMENT WITH THE CORRECT PRESSURE RATING.
BEFORE APPLYING PRESSURE, EXAMINE ALL FITTINGS AND EQUIPMENT FOR
DAMAGE. REPLACE ALL DAMAGED FITTINGS AND EQUIPMENT. DO NOT USE ANY
DAMAGED FITTINGS AND EQUIPMENT.
ISOLATE THE POWER SUPPLY BEFORE MAKING ANY ELECTRICAL CONNECTIONS TO
THE REAR PANEL.
2 Packaging
Check the contents of the PACE1000 packaging with the list that follows:
Packaging List - PACE1000
i) PACE1000 Pressure Indicator.
ii) Adaptor, power supply (GE part number 191-370).
iii) User guide and safety instructions, and CD containing the full documentation suite.
iv) Calibration certificate.
2.1 Packaging for Storage or Transportation
To store or return the instrument for calibration/repair do the procedures that follow:
1. Pack the instrument (Ref: K0470, User manual, Reference and Specification, Section
6.13).
2. Return the instrument for calibration/repair complete the return goods procedure (Ref:
K0470, User manual, Reference and Specification, Section 6.12).
3 Preparation for Use
The instrument can be used as a:
• Free-standing instrument positioned on a horizontal surface
• Panel-mounted using the panel-mount option kit (Ref: K0470, User manual, Section 2.5)
• Rack-mounted in a standard 19 inch rack using the rack-mount option kit (Ref: K0470,
User manual, Section 2.5).
K0467 Issue No. 4 5
For free-standing instruments, the feet on the front of the base can be used elevate the
instrument to a better viewing angle.
Note: Allow a free flow of air around the instrument, especially at high ambient temperatures.
3.1 Connecting the Instrument WARNINGS
TURN OFF THE SOURCE PRESSURE(S) AND CAREFULLY VENT THE PRESSURE LINES
BEFORE DISCONNECTING OR CONNECTING THE PRESSURE LINES. PROCEED WITH
CARE.
ONLY USE EQUIPMENT WITH THE CORRECT PRESSURE RATING.
BEFORE APPLYING PRESSURE, EXAMINE ALL FITTINGS AND EQUIPMENT FOR
DAMAGE. REPLACE ALL DAMAGED FITTINGS AND EQUIPMENT. DO NOT USE ANY
DAMAGED FITTINGS AND EQUIPMENT.
3.2 Pneumatic Pressure (Figure 2)
1. Refer to the Data sheet for the correct pressure mediums to be used.
2. Connect the Unit Under Test (UUT) to the required connection port.
Note: For instruments with NPT connections, use applicable pressure sealing.
Figure 2 Sealing Pneumatic Connections
 
recommended method alternative method below 100 bar
6 K0467 Issue No. 4
3.3 Pneumatic connections
For examples of adaptors (see Page 8).
3.4 Input Pressure (Figure 3)
1. Make sure the user systems can be isolated and vented.
2. Connect the Unit Under Test (UUT) to the output connection port.
Note: For instruments with NPT connections, use applicable pressure sealing.
Figure 3 Pneumatic Connections
Connection
Input ISO228/1 G 1/8 parallel threads (DIN ISO228/1, JIS B0202)
Reference ISO228/1 G 1/8 parallel threads (DIN ISO228/1, JIS B0202)
2
1
1) Connector 2) Bonded seal
K0467 Issue No. 4 7
4 Installation
The instrument connects to the Unit Under Test.
4.1 Input Pressure and Equipment
The pressure should not exceed 1.25 x full-scale or MWP stated on the rear panel of the
instrument.
To protect the instrument from over-pressure a suitable protection device (such as a
relief valve or bursting disc) must be fitted to prevent over pressurization.
4.2 Pneumatic Connection WARNING
PRESSURE RANGES > 210 bar (3000 psi) ARE ONLY RATED FOR HYDRAULIC USE.
Cautions
Do not exceed the maximum pressures stated in the appropriate Component
Manual for the unit under test.
Reduce pressure at a controlled rate when venting to atmosphere.
Carefully de-pressurize all pipes to atmospheric pressure before disconnecting
and connecting to the unit under test.
4.3 Connections
1. Switch off the power supply before connecting or disconnecting the instrument.
2. Use the appropriate sealing method for all pressure connections.
4.4 Method of connection
 
Recommended method
8 K0467 Issue No. 4
4.5 Adaptors
Refer to the Data sheet for the range of adaptors.








K0467 Issue No. 4 9
4.6 Hydraulic Pressure WARNINGS
HYDRAULIC LIQUID IS DANGEROUS. OBSERVE RELEVANT HEALTH AND SAFETY
PRECAUTIONS. USE APPROPRIATE PROTECTIVE BARRIERS AND EYE PROTECTION.
BEFORE APPLYING PRESSURE, EXAMINE ALL FITTINGS AND EQUIPMENT FOR
DAMAGE AND ENSURE THAT ALL EQUIPMENT IS TO THE CORRECT PRESSURE
RATING.
DO NOT EXCEED THE MAXIMUM WORKING PRESSURE OF THE INSTRUMENT.
PURGE ALL AIR FROM THE HYDRAULIC LIQUID.
PRESSURE RANGES > 210 bar (3000 psi) ARE ONLY RATED FOR HYDRAULIC USE.
DO NOT USE A SENSOR FOR GAS THAT HAS BEEN USED WITH HYDRAULIC LIQUID.
Cautions
Do not exceed the maximum pressures stated in the appropriate component
manual for the unit under test.
Reduce pressure at a controlled rate when venting to atmosphere.
Carefully de-pressurize all pipes to atmospheric pressure before disconnecting
and connecting to the unit under test.
Observe absolute cleanliness when using the instrument.
Severe damage can be caused if equipment connected to this instrument is
contaminated.
Connect only clean equipment to the instrument.
To avoid any contamination, an external filter is recommended.
4.7 Installation
The instrument connects to the Unit Under Test.
4.8 Input Pressure and Equipment
1. The pressure should not exceed 1.25 x full-scale or MWP stated on the rear panel of the
instrument.
2. To protect the instrument from over-pressure a suitable protection device (such as a
relief valve or bursting disc) must be fitted to limit the pressure to below the MWP.
Note: For instruments with NPT connections, use applicable pressure sealing.
Figure 4 Sealing Hydraulic Connections
 
Recommended
method
10 K0467 Issue No. 4
4.9 Hydraulic connections
Note: Pressure connections greater than 210 bar are 9/16” 18UNF Male Autoclave.
1. Switch off the power supply before connecting or disconnecting the instrument.
2. Use the applicable sealing method for all pressure connections.
3. Isolate the hydraulic pressures and de-pressurise the pipes before connecting or
disconnecting the instrument.
4.10 Pressure input (Figure 2)
1. Make sure the user systems can be isolated and vented.
2. Use the applicable sealing method for all pressure connections.
3. The hydraulic liquid must be clean, refer to specification given in the data sheet.
4. Connect the Unit Under Test (UUT) to the appropriate connection port.
5. Fill and bleed the UUT and connecting pipes.
5 Mounting kits
5.1 Rack-mount option (Figure 5)
There must be enough space at the rear of the instrument for all the cables and pipes. The length
of the cables and pipes must allow for the removal and installation of the instrument. The cooling
air of the instrument must not be obstructed. Allow a free flow of air through the equipment rack
and around the instrument, especially at high ambient temperatures.
Figure 5 Rack-mounting
Connection
Input ISO228/1 G 1/8 parallel threads (DIN ISO228/1, JIS B0202)
Reference ISO228/1 G 1/8 parallel threads (DIN ISO228/1, JIS B0202)