GE Monogram ZV900 User manual

Other manuals for Monogram ZV900

4

Other GE Ventilation Hood manuals

GE Monogram ZVC36L2SS User manual

GE

GE Monogram ZVC36L2SS User manual

GE 36" CUSTOM HOOD INSERT ZVC36LSS Manual

GE

GE 36" CUSTOM HOOD INSERT ZVC36LSS Manual

GE Monogram ZV370YSS User guide

GE

GE Monogram ZV370YSS User guide

GE Monogram ZV950 User manual

GE

GE Monogram ZV950 User manual

GE MONOGRAM ZV800SJSS User guide

GE

GE MONOGRAM ZV800SJSS User guide

GE JV936DSS User manual

GE

GE JV936DSS User manual

GE Appliances JVE40 Operating instructions

GE

GE Appliances JVE40 Operating instructions

GE Monogram ZV1050 User manual

GE

GE Monogram ZV1050 User manual

GE Monogram ZVB30 User manual

GE

GE Monogram ZVB30 User manual

GE JV247 Operating instructions

GE

GE JV247 Operating instructions

GE Monogram ZV881WSS User manual

GE

GE Monogram ZV881WSS User manual

GE MONOGRAM ZV750SY Service manual

GE

GE MONOGRAM ZV750SY Service manual

GE Cafe CV936MSS Manual

GE

GE Cafe CV936MSS Manual

GE UVC9420 Original instructions

GE

GE UVC9420 Original instructions

GE UVW8361SLSS Service manual

GE

GE UVW8361SLSS Service manual

GE JVW5301, JVW5361 User manual

GE

GE JVW5301, JVW5361 User manual

GE GE Deluxe JV347X User manual

GE

GE GE Deluxe JV347X User manual

GE Profile JVB67HBB User manual

GE

GE Profile JVB67HBB User manual

GE UVC7300 Original instructions

GE

GE UVC7300 Original instructions

GE JV694SBB Training manual

GE

GE JV694SBB Training manual

GE Monogram ZV800 User manual

GE

GE Monogram ZV800 User manual

GE JVW5301SJ Manual

GE

GE JVW5301SJ Manual

GE JV960SCBR User manual

GE

GE JV960SCBR User manual

GE PVWC930 Operating instructions

GE

GE PVWC930 Operating instructions

Popular Ventilation Hood manuals by other brands

Gorenje S3 IHGC963S4X manual

Gorenje

Gorenje S3 IHGC963S4X manual

KOBE ISX2136SQB-1 Installation instructions and operation manual

KOBE

KOBE ISX2136SQB-1 Installation instructions and operation manual

U.S. Products ADVANTAGE-100H Information & operating instructions

U.S. Products

U.S. Products ADVANTAGE-100H Information & operating instructions

Kuppersberg DUDL 4 LX Technical Passport

Kuppersberg

Kuppersberg DUDL 4 LX Technical Passport

Framtid HW280 manual

Framtid

Framtid HW280 manual

Thermador HGEW 36 FS installation manual

Thermador

Thermador HGEW 36 FS installation manual

Electrolux LFT769X user manual

Electrolux

Electrolux LFT769X user manual

AEG X69453MVO UK user manual

AEG

AEG X69453MVO UK user manual

Broan B5836SS manual

Broan

Broan B5836SS manual

Heinner HDCH-6060RGBK quick start guide

Heinner

Heinner HDCH-6060RGBK quick start guide

Baumatic AS35SS instruction manual

Baumatic

Baumatic AS35SS instruction manual

Franke FTF 604 XS V2 Instructions for use and installation

Franke

Franke FTF 604 XS V2 Instructions for use and installation

Best UCB3I30SBW installation instructions

Best

Best UCB3I30SBW installation instructions

Gram EFU 503-90 X instruction manual

Gram

Gram EFU 503-90 X instruction manual

CIARRA CBCS6803 Installation and user manual

CIARRA

CIARRA CBCS6803 Installation and user manual

sauter SHG501 Instructions for installation and use

sauter

sauter SHG501 Instructions for installation and use

Franke 392-17 User instructions

Franke

Franke 392-17 User instructions

FALMEC Polar Black 35 Instruction booklet

FALMEC

FALMEC Polar Black 35 Instruction booklet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Installation
Instructions
36″Glass Canopy
Chimney Vent Hood
ZV900
49-80328
04-06 JR
14-5/8″
to top of
bracket
C
L
▼
ALIGN BOTTOM EDGE
WITH PENCIL LINE,
INDICATING BOTTOM
OF THE HOOD
Drill 2 (two) 3/16″pilot holes through studs or rear wall support
REAR WALL
MOUNTING TEMPLATE
49-80405 04-06 JR
Safety Information
2
BEFO E YOU BEGIN
ead these instructions completely and carefully.
• IMPO TANT—Save these instructions for
local inspector’s use.
• IMPO TANT—bserve all governing codes
and ordinances.
•Note to Installer —Be sure to leave these
instructions with the Consumer.
•Note to Consumer —Keep these instructions
with your wner’s Manual for future reference.
•Skill Level —Installation of this appliance requires
basic mechanical and electrical skills.
•Completion Time — 1 to 3 Hours.
•Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the warranty.
For Monogram local service in your area, call
1.800.444.1845.
For Monogram service in Canada, call 1.888.880.3030
For Monogram Parts and Accessories, call
1.800.626.2002.
CAUTION:
Due to the weight and size of these vent hoods and to
reduce the risk of personal injury or damage to the
product, TWO PEOPLE A E EQUI ED FO P OPE
INSTALLATION.
P UDENCE :
À cause du poids et de la taille de ces hottes et pour
reduire le risque de blessures et de dommages, IL FAUT
DEUX PE SONNES POU FAI E L’INSTALLATION
CO ECTEMENT.
WA NING:
To reduce the risk of fire or electrical shock, do not
use this range hood with any external solid-state speed
control device. Any such alteration from original factory
wiring could result in damage to the unit and/or create
an electrical safety hazard.
AVE TISSEMENT :
Pour réduire le risque d’incendie ou de choc électrique,
il ne faut pas utiliser cette hotte avec un régulateur de
vitesse électronique externe. Toute modification de ce
type du branchement d’usine peute endommager
l’appareil ou créer un risque de choc électrique.
TO EDUCE THE ISK OF FI E, USE ONLY METAL
DUCTWO K.
WA NING: TO EDUCE THE ISK OF FI E,
ELECT ICAL SHOCK O INJU Y TO PE SONS, OBSE VE
THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch power off at
the service panel and lock service panel to prevent
power from being switched on accidentally. If the
service panel cannot be locked, fasten a tag or
prominent warning label to the panel.
AVE TISSEMENT :
POU ÉDUI E LE ISQUE D’INCENDIE, DE CHOC
ÉLECT IQUE OU DE BLESSU ES, IL FAUT OBSE VE LES
EGLES SUIVANTES :
A. Utiliser cet appareil uniquement de la maniére prévue
par le fabricant. En cas de question, consulter le
fabricant.
B. Avant toute intervention ou nettoyage, couper
l’alimentation électrique au disjoncteur et verrouiller
le panneau du disjoncteur pour éviter la mise sous
tension accidentelle. S’il n’est pas possible de
verrouiller le panneau du disconcteur, attacher un
placard ou une étiquette trés visible au panneau.
•For general ventilating use only. Do not use to
exhaust hazardous or explosive materials or vapors.
•Structural framing, installation work and electrical
wiring must be done by qualified person(s)
in accordance with all applicable codes and
standards including fire-rated construction.
•Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guidelines and safety standards such as those
published by the National Fire Protection Association
(NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
•Local codes vary. Installation of electrical
connections and grounding must comply with
applicable codes. In the absence of local codes, the
vent should be installed in accordance with National
Electrical Code ANSI/NFPA 70-1990 or latest edition.
CAUTION:To reduce risk of fire and to
properly exhaust air, be sure to duct air outside—do not
vent exhaust air into spaces within walls or ceilings or
into attics, crawl spaces or garages.
P UDENCE :Il faut prendre soin d’installer
un conduit vers l’extérieur pour réduire le risque
d’incendie et pouvoir évacuer l’air correctement. Il ne
faut pas évacuer l’air correctement. Il ne faut pas
évacuer l’air dans l’espace entre les parois d’un mur, un
plafond ou un grenier, un espace sanitaire ou un garage.
INSTALLATION OPTIONS
NOTE: Installation height should be measured from the
cooking surface to the outer glass sides.
This hood may be installed onto a wall and vented
to the outdoors, or it can be installed for recirculating
operation. All necessary parts for recirculating
operation are supplied with the hood. No kits
required.
This hood can be installed over any Monogram
electric cooktop or gas cooktop. It cannot be
installed over a Monogram Professional cooktop
or range.
Design Information
3
CONTENTS
Design Information
Product Dimensions and Clearances ....................................................3
Installation ptions ........................................................................................3
Installation Preparation
Advance Planning, Ductwork, Framing ................................................4
Power Supply ....................................................................................................4
Duct Fittings ......................................................................................................5
Tools and Materials Required ....................................................................6
Remove the Packaging ................................................................................6
Determine Installation Height ..................................................................7
Wall Mount Installation Heights ..............................................................7
Check Installation Hardware......................................................................8
Installation—Vented to the Outside
Step 1, Install Framing for Hood Support ............................................9
Step 2, Install Mounting Bracket............................................................10
Step 3, Install Duct Bracket......................................................................10
Step 4, Prepare the Hood..........................................................................11
Step 5, Mount the Hood ............................................................................12
Step 6, Level the Hood................................................................................12
Step 7, Connect Ductwork........................................................................12
Step 8, Connect Electrical ........................................................................13
Step 9, Install Duct Covers........................................................................14
Step 10, Install Filters..................................................................................14
Step 11, Finalize Installation....................................................................14
Installation— ecirculating
Ductwork, Wiring Locations ....................................................................15
Step 1, Install Framing for Hood Support..........................................15
Step 2, Install Mounting Bracket............................................................16
Step 3, Install Duct Bracket......................................................................16
Step 4, Prepare the Hood..........................................................................17
Step 5, Mount the Hood ............................................................................17
Step 6, Level the Hood................................................................................17
Step 7, Size and Cut Duct Piece ............................................................18
Step 8, Connect Electrical ........................................................................18
Step 9, Install Duct Covers........................................................................19
Step 10, Install Filters..................................................................................19
Step 11, Finalize Installation....................................................................19
P ODUCT DIMENSIONS
AND CLEA ANCES
The vent hood must be installed 24″min., and
30″max. above the cooking surface. The hood
installation height above the cooking surface
depends upon ceiling height.
The telescopic duct cover conceals the ductwork
running from the top of the hood to the ceiling.
The supplied duct cover is sized to reach 8′to
9′ 5″ceiling heights.
The ZX90010 accessory is available for ceiling
heights of 9′6″to 10′5″.
*Height
to
Ceiling
7/16"
3 1/4"
35 7/8"
* The Supplied Duct Cover Fits 8′to 9′5″ Ceiling
Heights. For 9′6″to 10′5″ceilings, order ZX90010.
*Height
to
Ceiling
20 7/16” 35 7/8”
3 1/4” 24” Min.
30” Max.
Installation Preparation
4
ADVANCE PLANNING
•Determine the exact location of the vent hood.
•Plan the route for venting exhaust to the outdoors.
•Use the shortest and straightest duct route possible. For
satisfactory performance, duct run should not exceed 100 ft.
equivalent length for any duct configurations.
•Refer to “Duct Fittings” chart to compute the maximum
permissible length for duct runs to the outdoors.
CAUTION:To reduce risk of fire and to properly
exhaust air, be sure to duct air outside—do not vent exhaust
air into spaces within walls or ceilings or into attics, crawl
spaces or garages.
P UDENCE :Il faut prendre soin d’installer un
conduit vers l’extérieur pour réduire le risque d’incendie et
pouvoir évacuer l’air correctement. Il ne faut pas évacuer l’air
correctement. Il ne faut pas évacuer l’air dans l’espace entre
les parois d’un mur, un plafond ou un grenier, un espace
sanitaire ou un garage.
•Use metal ductwork only. These hoods must use
8″round duct.
•Install a wall cap with damper or roof cap at the exterior
opening. rder the wall or roof cap and any transition
needed in advance.
Wall Framing for Adequate Support
•This vent hood is heavy. Adequate structural support must
be provided in all types of installations. The hood must be
secured to vertical studs in the wall, or to a horizontal
support.
•The vent hood should be on site before final framing and
wall finishing. This will help to accurately locate the duct
work and electrical service.
•Installation will be easier if the vent hood is installed before
the cooktop and countertop are installed.
Accessory Duct Cover
•This hood is shipped with a decorative duct cover for ceiling
heights of 7′11″to 9′5″. ZX90010 duct cover accessory
is available to reach 9′6″to 10′ 5″ceiling heights. The
accessory should be ordered with the hood and be
on site before installation begins.
POWE SUPPLY
IMPO TANT – (Please read carefully)
WA NING: FO PE SONAL SAFETY, THIS
APPLIANCE MUST BE P OPE LY G OUNDED.
AVE TISSEMENT :P UR DES RAIS NS DE
SÉCURITÉ, CET APPAREIL D IT ÊTRE C RRECTEMENT MISE
À LA TERRE.
Remove house fuse or open circuit breaker before beginning
installation.
Do not use an extension cord or adapter plug with this
appliance. Follow National electrical codes or prevailing local
codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch circuit,
and protected by a 15 or 20 amp circuit breaker or time delay
fuse.
•Wiring must be 2 wire with ground.
•If the electrical supply does not meet the above
requirements, call a licensed electrician before proceeding.
•Route house wiring as close to the installation location as
possible, in the ceiling or back wall.
•Connect the hood wiring to the house wiring in accordance
with local codes.
Grounding instructions
The grounding conductor must be connected to a grounded
metal, permanent wiring system, or an equipment-grounding
terminal or lead on the hood.
WA NING:The improper connection of the
equipment-grounding conductor can result in a risk of
electric shock. Check with a qualified electrician or service
representative if you are in doubt whether the appliance is
properly grounded.
AVE TISSEMENT : Le mauvais branchement du
fil de mise à la terre peut causer un choc électrique. En cas de
doute, consulter un électricien qualifié ou un technicien pour
déterminer si l’appareil est à la terre.
CAUTION:Automatically perated Device –
To reduce the risk of injury disconnect from power supply
before servicing. This unit is equipped with an integral
disconnecting switch located inside the blower housing.
P UDENCE :Appareil commandé
automatiquement. Afin de réduire les risques de blessure,
débranchez l’appareil de l’alimentation électrique avant de
procéder à une réparation. L’appareil est équipé d’un
sectionneur intégral situé à l’intérieur du logement du
ventilateur.
DUCT FITTINGS
Use this chart to compute
maximum permissible lengths for
duct runs to outdoors.
NOTE: Do not exceed maximum
permissible equivalent lengths!
Maximum duct length:
100 foot for 8″round duct
Flexible ducting:
If flexible metal ducting is used,
all the equivalent feet values in
the table should be doubled.
The flexible metal duct should
be straight and smooth and
extended as much as possible.
D N T use flexible plastic
ducting.
NOTE: Any home ventilation
system, such as a ventilation hood,
may interrupt the proper flow of
combustion air and exhaust
required by fireplaces, gas
furnaces, gas water heaters and
other naturally vented systems.
To minimize the chance of
interruption of such naturally
vented systems, follow the
heating equipment manufacturer s
guidelines and safety standards
such as those published by NFPA
and ASHRAE.
This Hood Must Use an
8″ound Duct.
5
Installation Preparation
Total
Equivalent Quantity Equivalent
Duct Piece Dimensions Length* Used Length
Round, 1 ft.
straight (per foot
length)
3-1/4″x 12″1 ft.
3-1/4″x 24″(per foot
straight length)
8″round
90° elbow 15 ft.
8″round
45° elbow 8 ft.
3-1⁄4″x 12″
90° elbow 11 ft.
3-1/4″x 12″or
45° elbow 6 ft.
3-1/4″x 12″
90° flat elbow 24 ft.
8″round to
3-1/4″x 12″
or 3-1/4″x 24″transition 1 ft.
3-1/4″x 12″to 8″
round transition 8 ft.
8″round
to 3-1/4″x 12″or
transition 90° elbow 16 ft.
3-1/4″x 12″to 8″round
round transition 90° elbow 17 ft.
8″round
wall cap
with damper 30 ft.
3-1/4″x 12″wall cap
with damper 30 ft.
8″round
roof cap 26 ft.
8″round
roof vent 26 ft.
*Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are
based on actual tests conducted by GE Evaluation
Engineering and reflect requirements for good
venting performance with any ventilation hood.
Total Duct Run
Installation Preparation
EMOVE THE PACKAGING
CAUTION: LIFT THE H D UT F THE B X
BY THE CENTER METAL P RTI N. D N T LIFT BY THE
GLASS SIDES.
P UDENCE : LEVEZ LA H TTE À
L’EXTÉRIEUR DE LA B ÎTE PAR LA P RTI N MÉTAL
CENTRAL. NE LEVEZ PAS PAR LES CÔTÉS DE VERRE.
CAUTION: Wear gloves to protect against
sharp edges.
P UDENCE : Portez des gants pour éviter
les blessures causées par les tranchants.
•Grasp the hood by the metal insert in the center
and lift straight up and out of the box.
•Remove and properly discard the plastic wrapping.
•Remove parts box, duct covers and other
packaging.
TOOLS AND MATE IALS EQUI ED
(NOT SUPPLIED)
Tape measure
Knife
Spirit level
Wire cutter/stripper
Wire nuts
Electric drill with 5/16″and 3/8″bits
Phillips and flat blade screwdrivers
Hammer
Pliers
Safety glasses
Duct tape
Tape to mount template
Gloves to protect against sharp edges
120V 60Hz. 15 or 20 Amp, 2 wire with
ground Properly grounded branch circuit
Strain relief for junction cover
8″round metal duct, length to suit
installation
Saw, jig saw or reciprocating saw
Measuring tape
Electric drill
with 5/16” and
3/8” Bits
12” long
Phillips
head
screwdriver
Safety glasses
Gloves
Spirit level
Knife
Wire
cutter/stripper
Flat blade
screwdriver
Hammer
Pliers
Duct tape
Masking tape
Wire nuts
Strain relief
Saw, jig saw or
reciprocating
saw
6
8″round metal duct,
length to suit
installation
7
Wall Mount ZV900
Installation Heights
Actual *Possible
Ceiling *Possible VENTED ECI CULATING
Height Installation Height Installation Height
7′ 11″24″to 26″24″to 26″
8′0″24″to 27″24″to 27″
8′1″24″to 28″24″to 28″
8′2″24″to 29″24″to 29″
8′ 3″24″to 30″24″to 30″
8′4″24″to 30″24″to 30″
8′5″24″to 30″24″to 30″
8′6″24″to 30″24″to 30″
8′7″24″to 30″24″to 30″
8′8″24″to 30″24″to 30″
8′9″24″to 30″24″to 30″
8′10″24″to 30″25″to 30″
8′11″24″to 30″26″to 30″
9′0″25″to 30″24″to 30″
9′1″26″to 30″24″to 30″
9′2″27″to 30″24″to 30″
9′3″28″to 30″24″to 30″
9′4″29″to 30″24″to 30″
9′5″30″25″to 30″
9′6″24″to 30″24″to 30″
9′7″24″to 30″24″to 30″
9′8″24″to 30″24″to 30″
9′9″24″to 30″24″to 30″
9′10″24″to 30″24″to 30″
9′11″24″to 30″24″to 30″
10′24″to 30″24″to 30″
10′1″24″to 30″24″to 30″
10′2″25″to 30″24″to 30″
10′3″26″to 30″25″to 30″
10′4″27″to 30″26″to 30″
10′5″28″to 30″27″to 30″
*Based on 36″countertop height.
ACCESSO Y ZX90010 SUPPLIED
DETE MINE INSTALLATION HEIGHT
•Telescopic duct covers are provided to conceal
the ductwork running to the ceiling.
•This hood can be installed for recirculating
operation. No kits required.
The vent hood must be installed 24″min. and
30″max. above the cooking surface. The hood
installation height, from the cooking surface to the
bottom of the hood, depends upon ceiling height.
Installation Preparation
24” Min.
30” Max.
36” Min.
ACCESSO Y ZX90010
NOTE: Measure
installation height
from the cooking
surface to the outer
glass portion of the
hood.
ACCESSO IES:
•rder ZX90010 accessory for ZV900 wall mount
hood to reach ceiling heights between 9′6″and
10′5″. This accessory contains one 40″long duct
cover.
CHECK INSTALLATION HA DWA E
Locate the hardware accessory box packed with the hood and check contents.
Installation Preparation
2
9-7/8"
11-1/2"
12"
27-3/4"
Mounting bracket
1 charcoal filter for
recirculating installation
2-piece decorative duct
cover (dimension shown
for reference only)
Air deflector for
recirculating
installation only
Duct bracket
14-5/8″
to top of
bracket
C
L
▼
ALIGN BOTTOM EDGE
WITH PENCIL LINE,
INDICATING BOTTOM
OF THE HOOD
Drill 2 (two) 3/16″pilot holes through studs or rear wall support
REAR WALL
MOUNTING TEMPLATE
49-80405 04-06 JR
Wall mount template
8
HARDWARE PACKAGE
Locate and count
screws
3 wood
screws
3 wall
fasteners
3 wall bracket
screws
12 hood
attachment
screws
27-3/4”
12-7/8”
23-7/8”
11-1/2”
Stainless steel filter
2 thumb
screws
9
INSTALL F AMING FO HOOD
SUPPO T
IMPO TANT— Framing must be capable of
supporting 100 lbs.
If drywall is present, mark the screw hole locations for
the top mounting brackets. Remove the template.
•Cut away enough drywall to expose 2 vertical studs
at the bracket location indicated on the template.
•Install a horizontal support at least 1″x 6″
between two wall studs at the bottom mounting
bracket installation location. The horizontal support
must be flush with the room side of the studs.
Use cleats behind both sides of the support to
secure to wall studs.
•Reinstall drywall.
1
Centerline of
Installation
Space
8" Min. Opening for Ductwork
View From Rear
Cleats
1" x 6" Min.
Mounting
Support
Installation Instructions
Centerline of
installation
space
View from rear
cleats
1”x 6”min.
mounting
support
DUCTWO K, WI ING LOCATIONS
Determine the exact location of the vent hood.
•Locate the template packed with the literature.
– Measure 36″from the floor to the top of the cooking
surface. Add hood installation height determined on
page 7. Mark that location.
– Use a level to draw a straight pencil line on the wall.
– Tape the template in position along the penciled
line. CHECK T BE SURE THE TEMPLATE IS LEVEL.
Ceiling ducting:
If ductwork will vent straight up to the ceiling:
•Use a level to draw a line straight up, from the
centerline on the template to the ceiling.
•Measure 5-1/2″from the back wall to the centerline
of an 8-1/2″hole on the ceiling.
NOTE: If drywall is not present, add drywall thickness
to the 5-1/2″dimension.
Wall Ducting:
If ductwork will vent to the rear:
•Use a level to draw a line straight up from the
centerline on the template.
•Measure at least 26″above the pencil line that
indicates the bottom installation height, to the
centerline of an 8-1/2″dia. duct hole. (Hole may
be elongated for duct elbow.)
HOUSE WI ING LOCATION:
•The junction box is located on the top left side
of the hood.
•Wiring should enter the back wall at least 22″above
the bottom of the hood, and within 6″of the left side
of the centerline.
5-1/2”centerline to wall
8-1/2”dia. hole
FOR CEILING VENT DUCTING
Centerline 26”above
the marked bottom
pencil line for
installation height.
FOR WALL VENT DUCT
INSTALLATION—VENTED TO THE OUTSIDE
Ceiling
8-1/2”min. opening for ductwork