Quick Start Card
in.yj-2™North American version
2- Connect the main power
1- Connect all outputs & keypads
3- Select spa configuration (see back page)
3
At first startup the keypad display
will show L 1 or LL 1.
Note: To re-enter the Low level
selection menu, hold the
Pump 1 key for 30 seconds.
Note: If the keypad does not have a
Program or Filter key, use the Light
key instead.
Note: For the Color keypad series,
select Settings menu, go into
Electrical config and choose the
appropriate Low level.
Use the Up/Down key to choose the
new Low level configuration number.
Press the Program key to confirm the
selection.
21
Heater connections
(P3 & P4 Element, P5 Ground)
P33 - Light outputs
(12 V DC, 500 mA Max.)
Main power
entry connection
Aperture Ø 2.54 cm (1'')
Ground:
connect all Green wires: P27, P28, P29 or P30
C1 - Main keypad
connector
P1 - Heater communication cable
Bonding lugs:
connect redundant
ground cable to
heater, pumps, etc.
75 L/min (20 GPM) minimum water flow required.
This side up
Outputs:
in.yj-2 pack has 2 relay controlled outputs
Out 1: K7-P
Out 2: K6-P
Direct: P25
240 V (4 wires)
Remove and discard brown wire and
insert each wire into the appropriate
socket of the main terminal block ac-
cording to the color code indicated on
the sticker. Use a flat screwdriver to
tighten the screws on the terminal.
Look at the pump and accessory voltage requirement and make sure to connect
each WHITE common wire to the correct tab on the board: Use any neutral tab for
120 V or use any LINE2 tab for 240 V
WARNING! All connections must be made by a qualified electrician in
accordance with the national electrical code and any state, provincial or local
electrical code in effect at the time of the installation. This product must always be
connected to circuit protected by a Ground Fault Circuit Interrupter (GFCI).
2.a- Electrical wiring 2.b- Pump & accessory voltage
Press and hold the Program key for
20 seconds until you access the
breaker setting menu.
Note: For the Color keypad series,
select Settings menu, go into Electri-
cal config and choose Input current.
4- Select breaker current
Breaker setting for GFCI used.
GFCI b
50 A 40 A
40 A 32 A
30 A 24 A
20 A 16 A
15 A 12 A Use the Up/Down key to select the
desired value. Then press the Program
key to confirm the selection.
Note: If the keypad does not have the
Program or Filter key, use the Light key
instead.
The values displayed by the system
correspond to 80% of the maximum
amperage capacity of the GFCI.
98
For more information, see our
website: www.geckoalliance.com
For more information, see our
website: www.geckoalliance.com
321
(10 to 20A is only to be use with
120V input)
Neutral: connect White wires from 120V pump
/ acc : P18, P19, P20 or P35
Line 2: connect White wires from 240V
pump / acc : P14, P15, P16 or P37
120 V (3 wires)
DO NOT REMOVE THE BROWN WIRE.
Insert each wire into the appropriate
socket of the main terminal block
according to the color code indicated
on the sticker. Use a flat screwdriver to
tighten the screws on the terminal.
CO - Communication links
in.touch, in.stik, Aux keypad in.k120
Information between ( ) indicates which connector/tab to use. See drawing from Step 1 for connector position.
Configuration selection chart
Standard
config. # Pump 1 Pump 2 Circ. Pump (CP)
configuration
Ozone (O3)
configuration Filter cycle daily Heater
1
2SP
(K7-P, K6-P)
10A-3A
___
2 * 1 hour
with P1 Pump 1
2
1SP
(K7-P)
4A
_ _
X
(K6-P)
2 * 1 hour
with P1 Pump 1
3
1SP
(K7-P)
4A
1SP
(K6-P)
8A
_ _
2 * 1 hour
with P1 Pump 1
4
1SP
(K7-P)
10A
_
X
(K6-P)
2A
_
2 * 6 hour
with CP CP
5
2SP
(K7-P, K6-P)
10A-3A
_
Always on
(P-25)*
2A
_2 * day purge CP
Software #316, rev. 001
* Circulation pump is not controled via a relay and will run 24/7. Circulation pumps must provide at least 75 L/min (18 GPM) without creating kinetic heating of the water
(Gecko recommends using the Aqua-Flo Circ-Master - 1/15 HP).
For complete TechBook or more information, see our website: www.geckoalliance.com
9919-101444-B Rev. 06-2016 www.geckoalliance.com
© Groupe Gecko Alliance Inc., 2016
All trademarks or registered trademarks are the property of their respective owners.
Glossary
XInstalled
1SP High speed only
2SP High and low speed
10A, 10A-3A Output current: 1 speed or High-Low speed

Other manuals for in.yj-2

1

Other Gecko Control System manuals

Gecko in.yj-2-CE Technical manual

Gecko

Gecko in.yj-2-CE Technical manual

Gecko in.yj-2 Technical manual

Gecko

Gecko in.yj-2 Technical manual

Gecko in.yj-3-ce Technical manual

Gecko

Gecko in.yj-3-ce Technical manual

Gecko Y Series User manual

Gecko

Gecko Y Series User manual

Gecko in.xm2 Technical manual

Gecko

Gecko in.xm2 Technical manual

Gecko Aeware Swim spa solution User manual

Gecko

Gecko Aeware Swim spa solution User manual

Gecko Y Series User manual

Gecko

Gecko Y Series User manual

Gecko in.yt-7-CE Technical manual

Gecko

Gecko in.yt-7-CE Technical manual

Gecko in.xm2 Technical manual

Gecko

Gecko in.xm2 Technical manual

Gecko in.yj-2-V3 Technical manual

Gecko

Gecko in.yj-2-V3 Technical manual

Popular Control System manuals by other brands

EOS LSG 36 Assembly and operating instruction

EOS

EOS LSG 36 Assembly and operating instruction

MG Master LV Quick installation guide

MG

MG Master LV Quick installation guide

RKC INSTRUMENT SR Mini HG Communication instruction manual

RKC INSTRUMENT

RKC INSTRUMENT SR Mini HG Communication instruction manual

Nevco MPCW-6 instructions

Nevco

Nevco MPCW-6 instructions

Intermatic I-Wave PE45343RC Installation and user guide

Intermatic

Intermatic I-Wave PE45343RC Installation and user guide

Automated Logic DIAG485 Technical instructions

Automated Logic

Automated Logic DIAG485 Technical instructions

Eaton Rapid Link RAMO5 manual

Eaton

Eaton Rapid Link RAMO5 manual

Innotech Micro 3000 User instructions

Innotech

Innotech Micro 3000 User instructions

Motorline professional CHAINLIFT User& installer's manual

Motorline professional

Motorline professional CHAINLIFT User& installer's manual

OPW Petro Vend 200 M1010 Installation, operation and maintenance guide

OPW

OPW Petro Vend 200 M1010 Installation, operation and maintenance guide

Chamberlain CAPXL installation manual

Chamberlain

Chamberlain CAPXL installation manual

igus Motion Plastics dryve D1 manual

igus

igus Motion Plastics dryve D1 manual

Idemia SIGMA Series Quick user guide

Idemia

Idemia SIGMA Series Quick user guide

potenza Aura 8 user guide

potenza

potenza Aura 8 user guide

BLAUBERG BLAUBOX MW750-4 user manual

BLAUBERG

BLAUBERG BLAUBOX MW750-4 user manual

Tigo TS4-L Important safety instructions

Tigo

Tigo TS4-L Important safety instructions

Norac UC4.5 installation manual

Norac

Norac UC4.5 installation manual

Index ABC 2 Series operating instructions

Index

Index ABC 2 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.