manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Gemo
  6. •
  7. Timer
  8. •
  9. Gemo DZ309 User manual

Gemo DZ309 User manual

GEMO
GEMOGEMO
GEMO DZ309
DIGITAL TIMER
Attention High Voltage, Double / Reinforced NOT CE Mark
Risk of Danger, Risk of Insulation Litter
Warning Electric Shock
TECHNICAL SPECIFICATION
•Dimensions : 96x96mm
•Panel Cut-out : 91x91mm
•Display : 2x4 Digits 7 Segment
•Inputs : START / RESET / GATE
3 x 230 VAC (0FF:0..50VAC, ON:150..240VAC)
•GATE Input : Inhibits count-down/up when GATE is ON
•Output : Out1, Out2; 2 x Relay (NO-O-NC), 250VAC, 2A, Resistive load
•Time Base : Selectable; 99:59 hours / 99:59 minutes / 599.9 seconds
•Resolution : 1 min. / 1 sec./ 0.1 sec.
•Accuracy : ± 0,5 % (Over full scale)
•Modes : Selectable 8 different modes
•Supply Voltage : 100..240VAC, 50-60Hz
•Power Consumption : < 6VA
•Humidity : 80% up to 30
o
C, then linearly decreases to 50% at 50
o
C (non-condensing)
•Altitude : < 2000 m
•EMC : EN 61000-6-1, EN 61000-6-3 (Only light industrial environment)
•Safety : EN 61010-1; Pollution degree 1, measurement category I, (Only light industrial
environment, double/reinforced isolated, non-conductive pollution environment)
•Protection Class : IP20; according to EN 60529
•Storage Temperature : -10
o
C .. 60
o
C (no icing)
•Operation Temp. : 0 .. 50
o
C
•Weight : < 0.5 kg
•Key : Micro switch
•Torque for screwing : Max. 0.5 N.m
no:
normally open
nc:
normally closed
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: i[email protected]om.tr
Tel: +90-312-3503900, Fax: +90-312-3511117
1
GEMO
INSTALLATION, USE and WARNINGS
●This device and its packing is NOT litter and may NOT be disposed of with domestic waste. Please return
this device and its packing to an appropriate recycling point at the end of its service life.
●Please read this user manual carefully and completely before installation and use. Please take into
consideration all warnings mentioned in this manual.
●DZ309 is suitable only for permanent panel type mounting
●Installation and use of this device must be done by qualified, authorized and trained technical personnel only.
●Inspect device carefully before installation. Do not install and use broken and defective devices.
●Do not disassemble device. Do not make any repair on any part of the device. There is no accessible part
inside the device. Please contact to manufacturer for broken and defective devices.
●Do not use device in environments subject to flammable, explosive and corrosive gases and/or substances.
●This device is designed for applications only in light industrial environments. This device is not suitable for
medical and residential use. This device is not suitable for use related with human health and safety. This
device is not suitable for automotive, military and marine use.
●Do not allow children and unauthorized people to use this device.
●Before installation and any technical work, disconnect the power supply and mains connections.
●Check the power supply voltage level before power on, and make sure voltage level is in specified limits.
Check quality of neutral line. Improper neutral line may give permanent damage to the device.
●Connect an external power switch and an external fuse (1A, 250VAC) to the power supply line that are easily
accessible for rapid intervention. Connect an external fuse (2A, 250VAC) for each relay output separately.
●Use appropriate cables for power supply and mains connections. Apply safety regulations during installation.
●Install the device in a well ventilated place. Install the device permanently into a proper panel cut-out. Fix the
device with two fasteners supplied with the device. Only front panel must be accessible after installation is
completed.
●Do not operate the device other then the environmental conditions given in Technical Specification.
●Do not operate the device in environments that may cause conductive pollution.
●Take precautions against negative environmental conditions like humidity, vibration, pollution and high/low
temperature during installation.
●Keep device, signal cables and communication cables away from circuit breakers, power cables and
devices/cables emitting electrical noise. Use shielded and twisted signal and communication cables and
connect shield to earth ground on device side. Keep length of signal and communication cables less than 3m.
●In your applications, always use separate and independent mechanical and/or electromechanical
devices/apparatus to support DZ309 to handle emergency cases..
●Use insulated cable end-sleeves at the end of cables screwed to the device connector terminals.
●Maximum torque for screwing; 0.5 N.m.
●Please check www.gemo.com.tr for latest device and documentation updates regularly. All updates and all
information are subject to change without notice.
GENERAL SPECIFICATION
●This device is designed for basic timer applications only in light industrial environments.
●µP based Digital Timer with START/RESET/GATE input
●2x4 7 Segment LED display
●Selectable 8 different modes
●Counts hour / minute / second
●Loads Timer value & OUT status at the latest power failure after the first power on
●Displays SET or remaining time
●EEPROM memory to store settings
●96x96mm
●Easy connection with plug-in connectors
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: i[email protected]om.tr
Tel: +90-312-3503900, Fax: +90-312-3511117
2
GEMO
FRONT PANEL RESET PROGRAMMING TIMER SET VALUE
SELECTING TIME BASE & MODES
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: i[email protected]om.tr
Tel: +90-312-3503900, Fax: +90-312-3511117
3
Press for 2 sec.
RESET
Press for 3 sec.
SETSET
t.bAS
Sec,Min,Hour
Prog. end
Upper Display
Lower
display
+
Out 0..7
Upper Display
Lower
display
SETSET
SETSET
P.rES YEs, no
Upper Display
SETSET
Lower
display
Cod Enter 162
Upper Display
Lower
display
SETSET
Enter fixed password; 162
Sec: Second (000.0 .. 599.9)
Min: Minute (00.00 .. 99:59)
Hour: Hour (00.00 .. 99:59)
Select mode of operation
Power-on Reset:
Yes: Timer SET value is reset
after power-on
No:
Loads Timer value & OUT status
at the latest power failure after
the first power on.
Press for 3 sec.
SET
t.on/t.A
Prog. end
Upper Display
Lower
Display
t.oFF/t.B
Upper Display
Lower
Display
SET
t.SEt
Set Value
Upper Display
Lower
Display
If Out is selected as;
0,2,3,4,6,7
Second : 000.0 .. 599.9
Minute : 00.00 .. 99.59
Hour : 00.00 .. 99.59
Prog. end
SET
Set Value
Set Value
If Out is selected as; 1,5.
Second : 000.0 .. 599.9
Minute : 00.00 .. 99.59
Hour : 00.00 .. 99.59
Out = 1, 5
If Out is selected as; 1,5.
Second : 000.0 .. 599.9
Minute : 00.00 .. 99.59
Hour : 00.00 .. 99.59
GEMO
MODES OF OPERATION
Notes:
1. For Mode1; t.On and t.OFF are accepted as min. 000.1 sec, 00.01 min. and 00.01 hr.
2. Timer counts up for Mode 6 & 7, and down for other modes.
3. For all modes; counting is inhibited (freeze) when GATE is ON.
CLAEANING
Do not use any solvents (alcohol, thinners, benzine, acid, etc.) or corrosive substances to clean the device.
Use only a dry and clean non-abrasive cloth. Before cleaning, disconnect the power supply and mains
connections.
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: i[email protected]om.tr
Tel: +90-312-3503900, Fax: +90-312-3511117
4
tA
tA
tB
tB
t.On
t.On
t.On
t.On
t.OFF
t.OFF
t.OFF
t.OFF
t.SEt
t.SEt
t.SEt
t.SEt
t.SEt
t.SEt
t.SEt
t.SEt
t.SEt
t.SEt
Mode : 4; Follow & ON Delay
Mode : ;2 One Shot after ON and OFF
Mode : ;1 Flashing with START/RESET
Mode : ;6
Chronometer - Count with START
Mode : ;7 Chronometer-Count with START, Reset with RESET
Mode : ;5 Delayed One Shot after OFF
Mode : ;
0
Pulsed Delay, OFF with RESET
Mode : 3; OFF Delay
t.SEt
Start
Start
Out1
Out2
Out1
Out2
Out1 is ON when Start input is ON.
Out2 becomes ON "t.SEt" after START
input is ON. Out1 & 2 are OFF when
START input is OFF. Out1 & 2 are OFF
when RESET input is ON .
Out1 & 2 become ON when
START input is triggered
(OFF > ON) or (ON > OFF)
and become OFF after "t.SEt".
START input can re-trigger
when Out1 & 2 are ON.
Out1 & 2 are OFF when
RESET input is ON.
Out1 & Out2 are periodically first
ON for "t.On" and then OFF for
"t.OFF” after START input is
triggered (OFF > ON). Out1 & Out2
are OFF when RESET input is ON. 1
Out2 is ON
when timer elapses T.SEt.
& 2 are OFF
Out1 & 2 are OFF when
RESET input is ON.
Out is ON and timer counts up
when START is ON. Timer freezes
when START is OFF. Timer
resets and Out1 when
START is OFF after Timer elapses
T.SEt.
1
Out2 is ON
when timer elapses T.SEt.
& 2 are OFF when
RESET input is ON.
Out is ON and timer counts up
when START is ON. Timer freezes
when START is OFF. Timer
resets and Out1
Out1 & 2 are first ON after "tA" and then
OFF after "tB" when START is triggered
(ON > OFF). START input does not
re-trigger before "tB" elapses. Out1 & 2
are OFF when RESET input is ON.
t.SEt
t.SEt
Start
Start
Start
Start
t.SEt
t.SEt
Start
Reset
Reset
Gösterge
Gösterge
Out1
Out2
Out1
Out2
Out1
Out2
Out1
Out1
Out2
Out2
Reset
Out1 & Out2 become ON "t.SEt" after
START input is triggered (OFF > ON).
START input can not re-trigger timer
until it is reset with RESET input. Out1
& Out2 are OFF when RESET input is ON.
Start
Out1
Out2
Out1 & 2 become ON when START
input is ON. Out1 & 2 become OFF
"t.SEt" after START input is triggered
(ON > OFF). Out1 & 2 are OFF when
RESET input is ON .

Other Gemo Timer manuals

Gemo AZ961 User manual

Gemo

Gemo AZ961 User manual

Gemo DZ961 User manual

Gemo

Gemo DZ961 User manual

Gemo DZ304 User manual

Gemo

Gemo DZ304 User manual

Gemo DZ307 User manual

Gemo

Gemo DZ307 User manual

Popular Timer manuals by other brands

TFA TRILE TIME XL 38.2023 operating instructions

TFA

TFA TRILE TIME XL 38.2023 operating instructions

hager EH710 manual

hager

hager EH710 manual

ascon TT70 user manual

ascon

ascon TT70 user manual

Dretec Popola instruction manual

Dretec

Dretec Popola instruction manual

Intermatic ET91615CR Installation and programming guide

Intermatic

Intermatic ET91615CR Installation and programming guide

Orbit 57594-50 rB quick start guide

Orbit

Orbit 57594-50 rB quick start guide

Orbit B-hyve user guide

Orbit

Orbit B-hyve user guide

ENDA ETM1411 quick start guide

ENDA

ENDA ETM1411 quick start guide

ADE TD 1800-1 operating manual

ADE

ADE TD 1800-1 operating manual

BDH Elkay 3875A-1 Instruction guide

BDH

BDH Elkay 3875A-1 Instruction guide

Theben TR 611 top2 RC 24 V Installation and operating instructions

Theben

Theben TR 611 top2 RC 24 V Installation and operating instructions

Perel E305D2 quick start guide

Perel

Perel E305D2 quick start guide

Becker U26 operating instructions

Becker

Becker U26 operating instructions

Conrad Electronic C-Control TM-848-2 operating instructions

Conrad Electronic

Conrad Electronic C-Control TM-848-2 operating instructions

axhess 2.440.007 manual

axhess

axhess 2.440.007 manual

scigiene TM-619 user guide

scigiene

scigiene TM-619 user guide

Leviton TS300 installation instructions

Leviton

Leviton TS300 installation instructions

RainPoint TTV203WRF instruction manual

RainPoint

RainPoint TTV203WRF instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.