manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Gemo
  6. •
  7. Timer
  8. •
  9. Gemo DZ961 User manual

Gemo DZ961 User manual

GEMO
GEMOGEMO
GEMO DZ961
DIGITAL TIMER
Attention High Voltage, Double / Reinforced NOT CE Mark
Risk of Danger, Risk of Insulation Litter
Warning Electric Shock
TECHNICAL SPECIFICATION
•Dimensions : 96x96mm
•Panel Cut-out : 91x91mm
•Display : 2x3 Digits 7 Segment
•Function : Delayed output after RESET OFF
•RESET Input : 8 & 9 pins
•Scale : 99.9 minutes or 999 seconds (selectable)
•Resolution : 0.1 minute or 1 second
•Accuracy : ± 1 % (Over full scale)
•Out Output : Relay (NO-O-NC), 250VAC, 2A, Resistive load
•Supply Voltage : 100..240VAC, 50-60Hz
•Power Consumption : < 6VA
•Humidity : 80% up to 30
o
C, then linearly decreases to 50% at 50
o
C (non-condensing)
•Altitude : < 2000 m
•EMC : EN 61000-6-1, EN 61000-6-3 (Only light industrial environment)
•Safety : EN 61010-1; Pollution degree 1, measurement category I, (Only light industrial
environment, double/reinforced isolated, non-conductive pollution environment)
•Protection Class : IP20; according to EN 60529
•Operation Temp. : 0 .. 50
o
C
•Storage Temperature : -10
o
C .. 60
o
C (no icing)
•Weight : < 0.5 kg
•Key : Micro switch
•Torque for screwing : Max. 0.5 N.m
no:
normally open
nc:
normally closed
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: i[email protected]om.tr
Tel: +90-312-3503900, Fax: +90-312-3511117
1
GEMO
INSTALLATION, USE and WARNINGS
●This device and its packing is NOT litter and may NOT be disposed of with domestic waste. Please return
this device and its packing to an appropriate recycling point at the end of its service life.
●Please read this user manual carefully and completely before installation and use. Please take into
consideration all warnings mentioned in this manual.
●DZ961 is suitable only for permanent panel type mounting
●Installation and use of this device must be done by qualified, authorized and trained technical personnel only.
●Inspect device carefully before installation. Do not install and use broken and defective devices.
●Do not disassemble device. Do not make any repair on any part of the device. There is no accessible part
inside the device. Please contact to manufacturer for broken and defective devices.
●Do not use device in environments subject to flammable, explosive and corrosive gases and/or substances.
●This device is designed for applications only in light industrial environments. This device is not suitable for
medical and residential use. This device is not suitable for use related with human health and safety. This
device is not suitable for automotive, military and marine use.
●Do not allow children and unauthorized people to use this device.
●Before installation and any technical work, disconnect the power supply and mains connections.
●Check the power supply voltage level before power on, and make sure voltage level is in specified limits.
Check quality of neutral line. Improper neutral line may give permanent damage to the device.
●Connect an external power switch and an external fuse (1A, 250VAC) to the power supply line that are easily
accessible for rapid intervention. Connect an external fuse (2A, 250VAC) for each relay output separately.
●Use appropriate cables for power supply and mains connections.Apply safety regulations during installation.
●Install the device in a well ventilated place. Install the device permanently into a proper panel cut-out. Fix the
device with two fasteners supplied with the device. Only front panel must be accessible after installation is
completed.
●Do not operate the device other then the environmental conditions given in Technical Specification.
●Do not operate the device in environments that may cause conductive pollution.
●Take precautions against negative environmental conditions like humidity, vibration, pollution and high/low
temperature during installation.
●Keep device, signal cables and communication cables away from circuit breakers, power cables and
devices/cables emitting electrical noise. Use shielded and twisted signal and communication cables and
connect shield to earth ground on device side. Keep length of signal and communication cables less than 3m.
●In your applications, always use separate and independent mechanical and/or electromechanical
devices/apparatus to support DZ961 to handle emergency cases..
●Use insulated cable end-sleeves at the end of cables screwed to the device connector terminals.
●Maximum torque for screwing; 0.5 N.m.
●Please check www.gemo.com.tr for latest device and documentation updates regularly. All updates and all
information are subject to change without notice.
GENERAL SPECIFICATION
●This device is designed for basic timer applications only in light industrial environments.
●µP based digital Timer with Delayed (OUT) output
●ON DELAY with RESET OFF
●2x3 digit 7 segment display
●Front panel selectable time base; 99.9 minutes, 999 minutes
●Displays SET or remaining time
●EEPROM memory to store settings
●Dimensions; 96x96mm
●Easy connection with plug-in connectors
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: i[email protected]om.tr
Tel: +90-312-3503900, Fax: +90-312-3511117
2
GEMO
ADJUSTING SET VALUE
ADJUSTING TIME BASE
RESET VIA FRONT PANEL
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: i[email protected]om.tr
Tel: +90-312-3503900, Fax: +90-312-3511117
3
Press 2 sec
SET
SEt
00.0..99.9 min
000..999 sec
Prog. ends
Upper Display
SET
99.9, 999
SET
Adjust
Timer
Set Value
Press “Up” key during
Power on in order to adjust
this parameter.
999 seconds or 99.9 minutes
selection is done.
da, SAn
Press “Up” key
During Power ON
Follow
programming
steps
Press “Up” and “Down”
Keys at the same time
for 2 seconds
+
GEMO
OPERATION
CLAEANING
Do not use any solvents (alcohol, thinners, benzine, acid, etc.) or corrosive substances to clean
the device. Use only a dry and clean non-abrasive cloth. Before cleaning, disconnect the power
supply and mains connections.
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: i[email protected]om.tr
Tel: +90-312-3503900, Fax: +90-312-3511117
4
Display
Reset
OUT

Other Gemo Timer manuals

Gemo DZ309 User manual

Gemo

Gemo DZ309 User manual

Gemo DZ307 User manual

Gemo

Gemo DZ307 User manual

Gemo AZ961 User manual

Gemo

Gemo AZ961 User manual

Gemo DZ304 User manual

Gemo

Gemo DZ304 User manual

Popular Timer manuals by other brands

Competition Electronics POCKET PRO operating instructions

Competition Electronics

Competition Electronics POCKET PRO operating instructions

Vestamatic Time Control Easy Installation and operating instructions

Vestamatic

Vestamatic Time Control Easy Installation and operating instructions

Redback A 4500C operating manual

Redback

Redback A 4500C operating manual

Elitako DW12-001-230V operating instructions

Elitako

Elitako DW12-001-230V operating instructions

Magikist MagikTimer Plus instructions

Magikist

Magikist MagikTimer Plus instructions

Cumberland FT8SA user manual

Cumberland

Cumberland FT8SA user manual

Candeo Smartfoss CSF1TZ quick start guide

Candeo Smartfoss

Candeo Smartfoss CSF1TZ quick start guide

IDEAL LOGIC COMBI user guide

IDEAL

IDEAL LOGIC COMBI user guide

Swiss Timing POWERTIME II user manual

Swiss Timing

Swiss Timing POWERTIME II user manual

Theben TR 611 top3 manual

Theben

Theben TR 611 top3 manual

Cole Parmer GT-200 Series instruction manual

Cole Parmer

Cole Parmer GT-200 Series instruction manual

Astroflex RST-1 user manual

Astroflex

Astroflex RST-1 user manual

Oregon Scientific TR118 user manual

Oregon Scientific

Oregon Scientific TR118 user manual

Orbis ASTRO NOVA quick start guide

Orbis

Orbis ASTRO NOVA quick start guide

ADC AD-50 installation manual

ADC

ADC AD-50 installation manual

BDH Elkay 560A-1 Instruction guide

BDH

BDH Elkay 560A-1 Instruction guide

Emos E5229 manual

Emos

Emos E5229 manual

Kemo Electronic M113A quick start guide

Kemo Electronic

Kemo Electronic M113A quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.