The electrical equipment of the machine is to be checked and inspected at
regular intervals. Loose connections or scorched wires must be replaced at once.
If maintenance must be performed on the machine while still connected to a power
source, or in a "live" mode, always have a stand by person ready to disconnect the
power immediately, if necessary. The work area should always be marked by safety
tape in accordance with the applicable regulations. Please always use only properly
insulated tools.
Ground the feeder cable and any components with a ground rod before starting to
work on high-voltage assemblies, always disconnect the power supply before grounding.
Before restarting the machine carefully refit and fasten all parts removed for transport.
Always disconnect the power supply before moving the machine.
( 5 ) Grounding Instructions Shall Include the Following:
-GROUNDING INSTRUCTIONS
-This product should be grounded. In the event of an electrical short circuit, grounding
reduces the risk of electric shock by providing an escape wire for the electric current.
This product is equipped with a cord having a grounding wire with an appropriate
grounding plug. The plug must be plugged into an outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
-DANGER- Improper installation of the grounding plug bears the risk of electrocution
shock. If repair or replacement of the cord or plug is necessary, do not connect the
grounding wire to any of the flat blade terminals. The wire with a green insulation sheath
(with or without yellow stripes) is the grounding wire.
-Check with a qualified electrician or serviceman if the grounding instructions are not
completely understood, or if in doubt as to whether the product is properly grounded.
Do not modify the plug provided; if it will not fit the outlet, have the proper outlet installed
by a qualified electrician.
-This product is for use on a nominal 110(220/230/240)-volt circuit and has a grounding plug.
Make sure that the product is connected to an outlet having the same configuration as the
plug.
( 6 ) Extension Cords:
Only use a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle
suitable for the plug of the product. Make sure your extension cord is in good condition.
When using an extension cord, be sure to use the right cable size to carry the load of your
product. A cord of unsufficient capacity will cause a drop in line voltage resulting in loss of
power and overheating. Refer to the following table:
Length (ft) 25 50 100 150 200 250 300 400 500
Gauge 16 14 10 8 6 6 6 4 4
.4.