Genie GDG360BT User manual

User Manual
Please read these instructions carefully before operating the unit
and keep for further reference.
Access Control Proximity
Reader with Bluetooth
GDG360BT

Contents
ii
1. Features & Specification........................................................................................3
2. Operation Notes ...................................................................................................4
3. Diagram / Dimensions..........................................................................................4
4. Wiring Diagram.....................................................................................................5
5. Application............................................................................................................6
6. The App Guide ......................................................................................................7

User Manual Access Control Proximity Reader with Bluetooth
3
1. Features & Specification
• 1 administrator and 200 users
• Access modes : Bluetooth via app on Smartphone and RFID Card (EM 125KHz)
• Door sensor input for anti-tailgate operation
• User management : Add, delete and view user data, grant user access for
specific dates or time periods, change user passcode and audit trail logs for
last 1000 events
• Locking options: Door re-lock time, door always unlocked, door always locked
• LED & audible indicators
Specification
LED and Audible Indicators
Operating Voltage DC12–24V
Current Draw Standby : 90mA / 46mA, Active : 101mA / 51mA
Frequency and Storage
Format
125KHz, internal decimal number (ABA format, decimal conversion)
Read Range 3 cm
Inputs 1 RTE (Request to exit), 1 Door sensor (DS)
Outputs 1 SSR (Dry contacts N.O./N.C./COM.), 1 Tamper Alarm (ALM)
Indicator Light 3 LED’s (Red, Green, Blue)
Memory Volume 1 Administrator & 200 Users
Card Format EM-400x 64-bit Standard R/O or Compatible
SSR Contact Rating 2A / DC12V
SSR Output Time 1~1800 seconds (Adjustable on App)
Humidity 5%~95% (Non-Condensing)
Temperature -20°C~70°C
Bluetooth Module BLE 4.2
Auto Proximity Range 0~20m (Adjustable)
Dimensions 86 × 86 × 20 mm
Solid Blue LED Power on, Standby 1 Short beep Key press
Red LED Invalid access,
Door always locked
1 Long beep Buzzer sound
Valid access
Reset completed
Green LED Unlocked,
Door always unlocked
2 Short beeps Buzzer sound
Login completed
Flashing Blue LED Bluetooth
connecting
3 Short rapid beeps Continous buzzer sound
Device vandalised
Alarm activated

User Manual Access Control Proximity Reader with Bluetooth
4
2. Operation Notes
3. Diagram / Dimensions
The GDG360BT includes one pair of NO/NC/COM output contacts, which can
directly connect to a locking device or connect in parallel or series with access
control systems.
Reed Switch
Door closed status: NO contact
Door open status: NC contact
Using Reset Jumper
Note:
1. Make sure that the power input and SSR rating output (2A/12VDC) are correct.
2. Make sure that the “+” and “-” wires are connected correctly.
3. The door strike or relay must have a varistor or a diode across the door strike
terminals to suppress the back EMF of the strike. Failure to do so will damage
the relay contacts and electronic components, or even burn the controller.
86mm
86mm
20mm
Plug x2
Pan Head Phillips Screw x2
LED Indicator

User Manual Access Control Proximity Reader with Bluetooth
5
4. Wiring Diagram
The door strike or SSR must have a diode or varistor across the door strike
terminals to suppress the back EMF of the strike – failure to do so will damage the
SSR contacts and electronic components, or even burn the controller.

User Manual Access Control Proximity Reader with Bluetooth
6
5. Application
Note:
When connecting the GDG360BT to the access control system as shown above,
set the power supply timer to 0 second and adjust time settings on the App.

User Manual Access Control Proximity Reader with Bluetooth
7
6. The App Guide
Download the App
From either the Apple App store or Google Play, download the Easiprox app on
your smartphone (Android 5.0 and up, iOS 9.0 and up).
App Introduction
1. Login
Administrator: Enter Admin ID and Passcode to login.
Admin ID: ADMIN
Default Admin Passcode: 12345 (Passcode: 4~8 digits)
User: Enter User ID and User Passcode to login.
User ID and User Passcode are given by the Administra-
tor.
Note:
Administrator ID “ADMIN” can not be changed.
Please change Admin’s default passcode “12345” right
after you login as the Admin. Go to the “Settings”
page, press Admin Passcode to Edit Admin Passcode.
Login Success / Login Failure indications will be shown
as following:
• Login Success: You Have Successfully Logged In:
You May Now Unlock A Door.
• Login Failure: Login Failed. Please Verify Your Login
Information Or Contact Your Administrator.
2. Device Name
Tap and choose which device you want to unlock by pulling down the Device
name listing.
3. Device Distance
The distance between you and the Bluetooth device.The distance range is
between 0 to 20 upon Bluetooth signal strength and different circumstances.
4. Settings
Tap “Settings” to view or change setting functions
5. Entry
Press the “Open” button or the door icon to unlock the door.

User Manual Access Control Proximity Reader with Bluetooth
8
6. Auto
Press “Auto” to enable the auto unlock function to access.
Make sure to disable “Auto” before pressing “Settings” to enter the settings page.
7. Auto Proximity Range
Adjust Auto Proximity Range in the Settings page. The range is between 0 to
maximum 20 and it may have different results under different circumstances upon
Bluetooth signal strength.
The Administrator “Settings” Page
Tap “Settings” to view or change setting functions.
Figure 6
Figure 5Figure 4
Figure 3
Figure 2Figure 1

User Manual Access Control Proximity Reader with Bluetooth
9
1. Users (See Figure 1)
• Add / Delete / Edit user information.
• ID (Up to 16 characters)
• Passcode (4~8 digits)
• Card/Fob
2. Audit Trail (See Figure 3 and 4)
• Audit Trail is tracking last 1000 event logs.
• Enter an user ID to search events for an user.
• Tap to export all events to excel file.
• Tap to refresh all events.
3. Backup Data (See Figure 5)
• Backup Data is to backup Users, Admin Passcode, Lock Action, and Door Re-
lock Time to Administrator’s phone and can be restored except Device Name,
Auto Proximity Range, and Audit Trail logs.
• Step 1: Press “Backup Data”, the App will show: Backup all data now?
• Step 2: Press Confirm, the App will show: Backup Status Backup Completed!
4. Restore Backup (See Figure 5)
• Restore the last backup data by Admin’s phone to another Bluetooth device.
• Step 1: Press “Restore Backup”, the App will show: Backup all data now?
• Step 2: Press Confirm, the App will show: Restore Status Restore Completed!
5. Admin Card/Fob (See Figure 1)
• Enter or edit 10 numbers from Admin’s card/fob.
• Step 1: Tap “Admin Card/Fob.” The App will show Edit Admin Card/Fob.
• Step 2: Enter 10 numbers and press Confirm, the App will show Admin’s card/fob
number.
6. User Card/Fob (See Figure 2)
• Enter or edit 10 numbers from user’s card/fob.
• Step 1: Tap “Users.” The App will show User Info and Edit User Card/Fob.
• Step 2: Enter 10 numbers and press Confirm, the App will show User’s card/fob
number.
7. General Settings (See Figure 6)
• Device Name: Edit Device Name (Up to 16 characters)
• Admin Passcode: Edit Admin Passcode (4~8 digits)
• Lock Action (3 options) – Choose Door Re-lock Time, Door Always Unlocked,
and Door Always Locked.
• Door Re-lock Time: 6 seconds by default. You can modify Door Re-lock Time
from 1 to 1800 seconds.
• Auto Proximity Range: Adjust Auto Proximity Range here. The range is between
• 0 to maximum 20 and it may have different results under different
circumstances.
• Device Time: Make sure the Device Time is precisely synced with your current
time zone to have correct and precise access data and information.
• About us: View Device Model, App version, Website and E-Mail information.
• Firmware version: See Firmware version of your Bluetooth device.

User Manual Access Control Proximity Reader with Bluetooth
10
User’s Settings
Tap “Settings” to view or change setting functions. (See Figure 7 below)
• Device Name: User can only view the Device Name. (See Figure 8 below)
• Auto Proximity Range: User can adjust Auto proximity range between 0 to
maximum 20 to access.
• May have different results under different circumstances. (See Figure 9 below)
• About Us: View Device Model, App version, Website and E-mail information.
(See Figure 10 below)
Figure 9 Figure 10
Figure 8
Figure 7
Other manuals for GDG360BT
1
Table of contents
Other Genie IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Rosslare
Rosslare AC-425 Hardware installation and user's guide

Paxton
Paxton Switch2 installation manual

RBH Access Technologies
RBH Access Technologies UNC100 Hardware manual

Roger
Roger MCT84-BK-QB manual

Panasonic
Panasonic BMET200 - IRIS RECOGNITION Brochure & specs

Fermax