7ENGLISH
7) User can press START key for another alcohol test. When the display counts down to zero and the “READY”
indicator shows on the display together with beep tones, it is ready to start another test.
Alert Signals
The alcohol tester is designed to alert user as following:
8) Low Level – For measurement below 0.1‰ BAC, “0.00 ‰ BAC” will be shown on display
9) Safety Level – For measurements between 0.00‰ BAC Level (> 0.1‰ BAC) and the alcohol concentration
level shows on the display after test.
10) Alert Level – For measurements equal to or above the alert concentration level, the analyzer beeps together
with alcohol concentration level displays and “NO DRIVING” will then ashes on the LCD for 25 times (about
10s) together with RED backlight.
If reading greater than 1.5‰ BAC, “NO DRIVING” and “HI” will ashes for 25 times (about 10s) together with
RED backlight.
Press START key can stop the beep sound and enter into another test.
YOU ARE PROHIBITED TO DRIVE since you already exceed the alert level.
User Manual for alcohol tester with display
Note:
1) To ensure high precision readings, user should perform the auto-cleaning if unused for more than 2 weeks
(especially for the rst time of using). User should start the auto-cleaning process by removing the batteries and
power up again. The “AUTO CLEANING” indicator ashes. The 5-minutes auto cleaning starts and the display
counts down. The alcohol tester will give few beep sounds at the last minute of auto cleaning. The analyzer will
then turn off automatically after 1 minute and the cleaning process nishes. Before formal test, make sure no
alcohol residues left by blowing fresh air into the gas inlet.
2) Please notice that pressing the ON/OFF key at any time can easily terminate the auto-cleaning process.
3) To achieve an accurate reading, user should ensure there is no alcohol residue inside the chamber before
starting a new alcohol test. Users can pre-check the tester until the ‘0.00’ indication is shown on the display.
This may be achieved by pressing START key once. Holding the BLOW key and blow fresh air into gas inlet for
about few seconds. Alternatively, shaking the unit forwards and backwards several times will allow any alcohol
residue to leave before starting a new alcohol test.
4) After any 4 consecutive tests, allow the device to rest for 2 minutes.
5) An error message “Err” ashes on the display for 5 seconds for the following improper operations:-
i. When user does not hold the BLOW key for at least 7 seconds during blowing until a beep sound is heard.
ii. When user fails to start the test within 8 seconds after “READY” ashes.
6) When the product is unused, please store in a dry environment.
7) When low battery inductor ashes, the reading is not valid, please replace the batteries immediately.
8) If the difference between two successive reading >0.1‰, user should test again.