2.2.7. Modification of a program
Access the MODIFICATION mode (section 2.1) The
display will indicate Pro.
Press the MOD key to access the PROGRAMMING
menu.
The display will indicate Pr-1. Ready to modify program
1. The V/ Wkeys are used to select another program.
Press the MOD key to access the modification of the
displayed program.
The display will indicate Ph-1. Ready to modify phase
1. The V/ Wkeys are used to select another phase.
Press the MOD key to start the modification to the
values of the selected phase.
When the number of the phase is displayed (start of
phase), the STOP key is used to finalise the program
modification.
Once finalised the modification of a program, the
display will show the Pr-* report. (modified program).
A pulsation on key STOP allows to access at the
superior level of the menu. Two consecutive pulsations
allow exiting the MODIFICATION mode.
Activation of the phase
Allows programming the execution of the selected
phase.
Once the desired phase to be modified has been
selected, press the MOD key. The display will indicate
Ph-*.
OPTIONS MEANING
Ph-Y Availability of the phase to be executed
Ph-N Unavailability of the phase to be
executed
The Vkey will modify the displayed option.
The MOD key validates the displayed selection and
allows access to the following programmable function.
Bath level.
Allows the selection of bath level inside the washer.
OPTIONS MEANING
L-1 Low level
L-2 Medium level
L-3 High level
L-4 Extra high level
For safety, the options L-3 and L-4 are not
programmable in machines with pump drain.
The V/ Wkeys will modify the displayed option.
The MOD key validates the displayed selection and
allows access to the following programmable function.
Temperature of the washing phase
Allows modifying the water temperature in the phases in
which this function is available. In other phases, it is not
possible to program the water temperature.
OPTIONS MEANING
C-00 ... C-40
F 32 ... F 104
Range of programmable temperature in
soak, prewash and rinses phases.
C- 77:Centigrade degrees
F777:Fahrenheit degrees
C-00 ... C-80
F 32 ... F 176
Range of programmable temperature in
wash phase.
C- 77:Centigrade degrees
F777:Fahrenheit degrees
The V/ Wkeys will modify the displayed option.
The MOD key validates the displayed selection and
allows access to the following programmable function.
Dosing.
Permits to activate or deactivate dosing that appear in
the master table.
OPTIONS MEANING
d-0 Without dosing
d-1 External dosing of soak and prewash
detergent
d-2 External dosing of wash detergent
d-3 Bleach dosing
d-4 Softener or neutraliser dosing
n.p. Not possible to program dosing in the
phase
The first executed soak or pre-wash phase doses the
deposited detergent in the pre-wash compartment of
the washer dispenser. In these phases water enters
through this compartment.
The wash phase doses the product located at the wash
compartment of the washer dispenser. In the wash
phase the water enters through this compartment.
Options d-1 and d-2 only control the external product
dosing.
Options d-3 and d-4 control the entry of water into the
corresponding compartment of the dispenser and the
external product dosing.
The Vkey will modify the displayed option.
The MOD key validates the displayed selection and
allows access to the following programmable function.