What’s in the box:
• Quick Start Guide
• Centrifuge
• Power Cable
• Rotor
• Rotor Wrench
• Fuses (2 each)
• Door Key (small screwdriver)
GCM-R-24
Microcentrifuge
Quick Start Guide
UNPACKING THE UNIT
Please be sure to remove any packing materials used during initial shipment:
1) Open the lid: Use the included Door Key to press the buttons
on the right and left sides of the unit.
2) Remove foam pads at the hinge latches.
Continued . . .
INSTALLING AND BALANCING THE ROTOR
IMPORTANT: The rotor should always be loaded in a balanced
manner to avoid personal injury and to ensure centrifuge
longevity.
• When any tube is loaded, a tube of the same type, volume and
weight must be added in the opposite rotor location.
• Never intentionally run the centrifuge in an unbalanced
condition even if operation is not affected.
Locking Nut
Load the Rotor Onto the Shaft Symmetrically Load Centrifuge Tubes Into Rotor
Rotor Lid Knob
Install the Rotor Lid
®
Customer Service, Sales and Technical Support:
Phone: 1 (800) 394-4562 • 1 (201) 599-1400
Fax: 1(201)599-1406•E-mail:mail@globescientic.com
©2019GlobeScienticInc.Allrightsreserved.TheGlobeScienticlogoisaregisteredtrademarkofGlobeScienticInc.GCM-R-24Guide19107
GCM-R-24
Microcentrifuge
Quick Start Guide
For the full User Manual, please visit www.globescientic.com
CONTROL PANEL
Speed Display
Temperature Display
Time Display
1
2
34
5
IMPORTANT: Plug unit into appropriate main supply based
on the rated voltage.
Pulse � � � � � � � � � � � � � Press to accelerate and hold at the set
speed. The centrifuge stops immediately
once this button is released.Radius
Door� � � � � � � � � � � � � � Press to open the lid. This button is not
enabled while the centrifuge is running.
Start / Stop � � � � � � � Press to start the centrifuge. Press to
stop if centrifuge is already running.
Select� � � � � � � � � � � � � Press to choose the parameter you wish
to modify.
Adjustment Knob Rotate clockwise to increase parameter
values. Rotate counterclockwise to
decrease parameter values. Press to
switch between speed and RCF.
OPERATION
1
2
3
4
5
Rotor Tube Adapter Maximum Maximum Centrifugal Maximum
Type Type Required Speed (rpm) Radius (cm) RCF (×g)
2.0/1.5mL Tube — 15000 8.5 21380
0.2mL PCR Tube GCM-24-AD2 15000 6.9 17350
0.5mL PCR tube GCM-24-AD5 15000 7.6 19100
0.5mL PCR tube 15000 8.5 21380
  0.2mLPCRStrip GCM-24-AD52 15000 7.6 19100
0.2mLPCRStrip —  6.5/7.2 16350/18100
GCM-24-05ML
(optional)
GCM-24-2ML
GCM-24-PCR
(optional)
The centrifuge rotor can separate samples whose density is lower than 2.0g/ml. If the separated sample’s density is over 2.0g/ml, please
calculate the allowable speed using the following formula:
Allowable Speed (rpm) = Maximum Speed × (2�0(g/ml) / Sample Density (g/ml))1/2

Other Globe Scientific Laboratory Equipment manuals

Globe Scientific GCM-12 User manual

Globe Scientific

Globe Scientific GCM-12 User manual

Globe Scientific GHS-550HS User manual

Globe Scientific

Globe Scientific GHS-550HS User manual

Globe Scientific GCC-S User manual

Globe Scientific

Globe Scientific GCC-S User manual

Globe Scientific GCC-P User manual

Globe Scientific

Globe Scientific GCC-P User manual

Globe Scientific GCC-S User manual

Globe Scientific

Globe Scientific GCC-S User manual

Globe Scientific GCH-24 User manual

Globe Scientific

Globe Scientific GCH-24 User manual

Globe Scientific GCC-MP User manual

Globe Scientific

Globe Scientific GCC-MP User manual

Globe Scientific GTR-ID User manual

Globe Scientific

Globe Scientific GTR-ID User manual

Globe Scientific GCM-24 User manual

Globe Scientific

Globe Scientific GCM-24 User manual

Globe Scientific GCC-E User manual

Globe Scientific

Globe Scientific GCC-E User manual

Popular Laboratory Equipment manuals by other brands

Sigma 3-16PK Use and maintenance manual

Sigma

Sigma 3-16PK Use and maintenance manual

Solmetex Hg5 Installation and operation manual

Solmetex

Solmetex Hg5 Installation and operation manual

Scilogex SCI7-S user manual

Scilogex

Scilogex SCI7-S user manual

BMG Labtech spectrostar nano operating manual

BMG Labtech

BMG Labtech spectrostar nano operating manual

winkler PILZ WHG1 Series operating instructions

winkler

winkler PILZ WHG1 Series operating instructions

SPY JeepMeter operating instructions

SPY

SPY JeepMeter operating instructions

Essilor Pro-E 700 edger user manual

Essilor

Essilor Pro-E 700 edger user manual

impact SV003 user guide

impact

impact SV003 user guide

Covaris tissueTUBE Instructions for use

Covaris

Covaris tissueTUBE Instructions for use

Storz IMAGE1 PILOT instruction manual

Storz

Storz IMAGE1 PILOT instruction manual

Grobet USA 22.747 operating instructions

Grobet USA

Grobet USA 22.747 operating instructions

Molecular Devices ClonePix 2 manual

Molecular Devices

Molecular Devices ClonePix 2 manual

Thermo Scientific Sorvall X Pro Series Instructions for use

Thermo Scientific

Thermo Scientific Sorvall X Pro Series Instructions for use

Human HumaRoll user manual

Human

Human HumaRoll user manual

Waters Prep 150 LC System quick start

Waters

Waters Prep 150 LC System quick start

Spectro-UV Spectroline E Series Operator's manual

Spectro-UV

Spectro-UV Spectroline E Series Operator's manual

Collomix BIAX 45P instructions

Collomix

Collomix BIAX 45P instructions

Centurion Scientific C2006 instruction manual

Centurion Scientific

Centurion Scientific C2006 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.