MAR 2018 GFS-230 (Formerly A-47)
QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD
AUTOMATIC SPRINKLERS GL5613 & GL8113 CONCEALED
HORIZONTAL SIDEWALL
PRINTED U.S.A.
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658
F A X 9 8 9 - 8 4 6 - 9 2 3 1
www.globesprinkler.com
9 8 9 - 8 4 6 - 4 5 8 3
1-800-248-0278
GLOBE®PRODUCT WARRANTY
Globe agrees to repair or replace any of its own manufactured
products found to be defective in material or workmanship for a
period of one year from date of shipment.
For specic details of our warranty please refer to Price List
Terms and Conditions of Sale (Our Price List).
ORDERING INFORMATION
• Quantity •SIN • Style • Orice
• Thread Size • Temperature •Finishes desired
• Quantity - 5.6K Wrenches - P/N 329678
• Quantity - 8.0K Wrenches - P/N 329679
• Quantity - Protective Caps - P/N 327119
SPECIFY
CROSS SECTION
NOTE: METRIC CONVERSIONS ARE APPROXIMATE.
1FOR PAINTED PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS.
2FINISHES AVAILABLE ON SPECIAL ORDER.
***FACTORY PAINTED COVER PLATES MUST NOT BE REPAINTED. NON-FACTORY APPLIED PAINT MAY ADVERSELY DELAY OR PREVENT SPRINKLER
OPERATION IN THE EVENT OF A FIRE.
SPECIFICATIONS AND APPROVALS
SIN NOMINAL
“K” FACTOR
THREAD
SIZE LENGTH
135°F (57°C)
Cover Plate
155°F (68°C)
Cover Plate cULus
NYC-DOB
MEA
101-92-E
DOMED COVER
PLATE FINISHES***
135°F (57°C)
Sprinkler
155°F (68°C)
Sprinkler
175°F (79°C)
Sprinkler
GL5613
5.6 (80 metric) 1/2”NPT (15mm) 2 9/16” (6.5cm)
X X X X X
Chrome
White Painted
Other Painted Finishes1,2
GL8113
8.0 (116 metric) 3/4”NPT (20mm) 2 11/16” (6.8cm)
cULus LISTING DESIGN - USE REQUIREMENTS FOR LIGHT HAZARDS ONLY
SIN STYLE
SPRINKLER TEMPERATURES MAX. AREA OF
COVERAGE
WIDTH x LENGTH
Feet (Meters)
MIN.
PRESSURE
P.S.I. (bars)
MIN.
FLOW
G.P.M.
(L/min.)
DEFLECTOR
TO CEILING
DISTANCE
Inches (mm)
MIN. DISTANCE
BETWEEN
SPRINKLERS
Feet (Meters)
135°F
(57°C)
155°F
(68°C)
175°F
(79°C)
GL5613
CONCEALED
HORIZONTAL
SIDEWALL
X X X
16 (4.9) x 16 (4.9)
26.8 (1.85) 29 (110) 4 (101.6)
to
6 (152.4)
7 (2.1)
16 (4.9) x 18 (5.5)
X --- X
16 (4.9) x 20 (6.1) 32.7 (2.25) 32 (121)
X X X
16 (4.9) x 16 (4.9)
32.7 (2.25) 32 (121)
6 (152.4)
to
12 (304.8)
16 (4.9) x 18 (5.5)
X --- X
16 (4.9) x 20 (6.1)
GL8113
CONCEALED
HORIZONTAL
SIDEWALL
X X X
16 (4.9) x 16 (4.9) 10.3 (.71) 26 (98) 4 (101.6) to 12 (304.8)
6 (1.8)
X X X
16 (4.9) x 18 (5.5) 12.8 (.88) 29 (110)
4 (101.6) to 6 (152.4)
X --- X
16 (4.9) x 20 (6.1) 15.6 (1.08) 32 (121)
X X X
16 (4.9) x 18 (5.5) 15.6 (1.08) 32 (121)
6 (152.4) to 12 (304.8)
X --- X
16 (4.9) x 20 (6.1) 20.9 (1.44) 37 (140)
NOTE: METRIC CONVERSIONS ARE APPROXIMATE
SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS.
FOR COVERAGE AREA DIMENSIONS LESS THAN OR BETWEEN THOSE INDICATED, USE THE MINIMUM FLOW FOR THE NEXT HIGHEST COVERAGE AREA
FOR WHICH HYDRAULIC DESIGN CRITERIA ARE STATED.
QUICK RESPONSE
EXTENDED COVERAGE LIGHT HAZARD
AUTOMATIC SPRINKLERS GL5613 & GL8113
CONCEALED HORIZONTAL SIDEWALL
WALL
CEILING
COVER PLATE
CUP
SUPPORT SHELL
1" x 1/2" REDUCER - 1/2"NPT
1" x 3/4" REDUCER - 3/4"NPT
4" TO 12"
3 5/16"
DIA
3 1/8"
DIA.
2 1/8"
DIA.
2 1/2" DIA. MIN.
HOLE IN WALL
1"
1 1/8" MIN.
1 5/8" MAX.
3 5/16” DIA. DOMED COVER PLATE S/A PART NUMBERS
FINISH 135°F (57°C) 155°F (68°C)
CHROME 329489 329495
WHITE 329491 329497