Goldair GCW250 User manual

For model: GCW250
WALL MOUNTABLE CERAMIC HEATER
OPERATING INSTRUCTIONS

1. Use only the voltage specified on the rating
plate of the appliance.
2. Keep all objects at least 1 metre from the
front, sides and rear of the appliance. Do not
place appliance close to radiant heat source.
3. Do not operate in areas where petrol, paint or
other flammable liquids are used or stored.
4. Do not insert or allow foreign objects to enter
any ventilation or exhaust opening, as this
may cause an electric shock, fire or damage
to the appliance.
5. Do not operate this appliance with a
damaged cord, plug or after the appliance
malfunctions or has been dropped or
damaged in any manner. Return to a
qualified electrical person for examination,
electrical service or repair.
6. This appliance is intended for household use
only and not for commercial or industrial use.
7. Use this appliance only as described in this
manual. Any other use is not recommended
by the manufacturer and may cause fire,
electrical shock or injury.
8. The common cause of overheating is
deposits of dust or fluff in the appliance.
Ensure these deposits are removed regularly
by unplugging the appliance and vacuum
cleaning the air vents and grills.
9. Do not use abrasive cleaning products on
this appliance. Clean with a damp cloth (not
wet) rinsed in hot soapy water only. Always
removed plug from the mains supply before
cleaning.
10.Do not connect the appliance to mains
voltage until completely assembled and
adjusted.
11.Switch off and use handles provided when
moving.
12.Do not operate with cord set coiled up as a
heat build up is likely, which could be
sufficient to become a hazard.
13.The use of an extension cord with this
appliance is not recommended.
14. Do not remove plug from power socket until the
appliance has been switched off.
15. Do not remove plug from power socket by
pulling cord –always grip plug.
16. Always unplug appliance when not in use.
17. Do not twist, kink or wrap the cord around the
appliance, as this may cause the insulation to
weaken and split. Always ensure that all cord
has been removed from any cord storage area
and is unrolled before use.
18. This appliance is not intended for use by young
children or infirm persons unless they have been
adequately supervised by a responsible person
to ensure that they can use the appliance safely.
19. Do not use this appliance in the immediate
surrounds of a bath, a shower, or a swimming
pool or other liquids. The appliance must not be
immersed in any liquids.
20. When the appliance has been unpacked, check
if for transport damage and ensure all parts have
been delivered. If parts are missing or the
appliance has been damaged, contact the
Goldair Customer Services Team. (refer to
details on back page)
21. If your appliance does not work, or is not
working properly, contact the place of purchase
or the Goldair Customer Services Team. (refer
to details on back page). Repair work on the
appliance by unqualified persons can cause
serious risk to the user.
22. There are no user serviceable parts installed in
the unit.
23. Do not put your fingers or other articles into or
near the air inlet or outlet. Do not sit on the unit.
24. Do not place the unit in wardrobes or other
enclosed spaces as this may cause fire hazards.
25. This unit is not supposed to be used in or around
locations where foodstuffs, works of art or
delicate articles of science, etc are stored.
26. Indoor use only.
27. Children should be supervised to ensure that
they do not play with the appliance.
WARNINGSAND SAFEGUARDS

LOCATION
1. The appliance should be placed with a minimum distance of 90 cm away from flammable objects (e.g.
curtains), walls or other structures!
2. Installation of the heater on the wall MUST BE 1.8m high from the floor and the heater location MUST
NOT be directly below a main power socket.
POWER CORD
1. Do not lay the cord under a carpet. Do not lay rugs, mats or similar articles on it. Position the cord so that
it does not pose an obstruction or a tripping hazard.
3. Never pull the plug out of the socket at the cord!
4. Always disconnect the mains plug when the appliance is not in use.
Attention: The appliance may only be used for domestic use only - not industrial.
KNOW YOUR HEATER
BEFORE USE
1. Before use, remove all packaging and inspect the appliance for any damage. If there appears to be
any damage, please take back to place of purchase for a replacement.
2. Ensure that all the accessories are included as per diagram above before you continue with the
installation.
3. Ensure that the location of the heater installed is not directly under a power socket and that a power
socket is available to power the appliance for use.
4. Refer to the installation guide for further instruction.
7
6
3
2
1
5
4
1. On/Off button
2. Timer button
3. LED temp readout
4. Indicator lights
5. Outlet grille (louver)
6. Mounting screws
7. Remote control

INSTALLATION
Drill two holes on the wall allowing 1.8meters above the floor and 20cm from side walls. Be sure to make
the hole diameter is the same as the expanding screw pipe. Place the expanding screw pipe into the hole in
the wall and then fix two screws on the expanding pipe, keep the tips of the screws out approx. 10mm, and
hang up the heater. Ensure that the screws are strong enough. Screws and screw mounts are provided.
WARNING: DO NOT MOUNT DIRECTLY UNDER AN ELECTRICAL POWER SOCKET.
Please read these instructions carefully and keep for future reference.
USING THE HEATER
Before inserting the plug in electrical outlet, make sure that the correct voltage being used corresponds to
what is indicated on the rating label on the unit.
This instruction will apply to both the control panel on the heater and on the remote.
Plug the unit into the mains power supply, and then switch the ON the main power supply.

FAN MODE:
Remote & Manual:
1) Press the On/Off button, the heater will switch on, the louver will open and the fan will blow. The LED
screen will display the room temperature.
2) To switch the fan off, press the On/Off button another 4 times.
HEATING MODE:
Manual:
1) Press the On/Off button, the heater will switch on, the louver will open and the fan will blow.
2) Press the On/Off button again, to operate at 1000W heating mode.
3) Press the On/Off button again, to operate at 2000W heating mode.
4) Press the On/Off button again, to operate the 2000W heating mode with oscillating function.
5) To switch the heater OFF, press On/Off button again, the “COOLAIR” indicator flashes. The fan will
continue to operate for 30 -60 sec, and then it will switch off.
Remote:
1)Press On/Off button, the heater will switch on and the fan will blow.
2) Press the mode button once, to operate at 1000W heating mode.
3) Press the mode button again, to operate at 2000W heating mode.
4) Press the swing button, to operate the 2000W heating mode with oscillation.
5) To switch the heater OFF, press On/Off button again, the “COOLAIR” indicator flashes. The fan will
continue to operate for 30 -60 sec, and then it will switch off.
NOTE: The heater will switch OFF after 30-60 seconds of operation. This will allow the element to cool
down.
TIMER FUNCTION:
Timer function allows the fan heater to operate continuously for different set intervals, and can be
programmed up to 8 hours before automatically turning OFF. The below instructions apply for both Manual
and Remote operation.
1) Press Timer button once for 0.5h operation before turning OFF.
2) Press Timer button again for 1 hour. Press Timer button again for 1.5 hours, etc. Repeat this process
until the desired duration of operation is reached.
3) To remove the Timer function. Press the Timer button until all of the time indicators turn off.

BATTERY
The remote control use 2 x AAA battery. We recommend the use of Lithium type battery for longer use.
Note: Please follow battery disposal instruction on battery packaging, or contact your local councils for
safely disposal of batteries.
SAFETY SYSTEM
* In the event of abnormal overheating, a safety device shuts down the appliance automatically. After a short
cooling down phase, the appliance is ready for use again.
• If you still notice the same defect as above mentioned, remove the plug from the socket and consult your
authorized dealer to your after-sales service department.
• During use, do not touch or cover the air outlet. This may cause the unit to over heat, and the safety device
to operate.
MAINTENANCE
• Your appliance must be switched OFF via the main power supply and unplugged before proceeding with
any cleaning work.
• Clean the housing with a lightly damp cloth, a vacuum cleaner or a dusting brush.
• Never use flammable or abrasive cleaning agents such as benzene or spirit to clean the appliance.
• Never immerse the appliance in water!
• Clean the air inlet and outlet regularly with a vacuum cleaner.
• If the appliance is not used for an extended period it must be protected against excessive dust and dirt.
Please dismount the heater and store in a dry place away from sunlight and dirt.
SPECIFICATIONS
Model No GCW250
Voltage 220-240V AC
Frequency 50Hz
Output Power (W) 2000W max.
IMPORTANT! ~ NEVER COVER THIS HEATER!
SUPPORTAND TECHNICALADVICE
North Shore City, Auckland, New Zealand
Monday –Friday 8am-5pm
Phone: 0800 232 633
Website: www.goldair.co.nz

Your Goldair product has been inspected and tested and is guaranteed subject to the
following for a period to two years from the date of purchase against defects in
workmanship and materials. During this period, such defects will be rectified by
repair or replacement of the product purchased. Your product contains no user
serviceable components and this warranty becomes invalid if in our opinion the
product has been misused, abused, incorrectly installed, tampered with, connected
to an electrical supply not corresponding with the name plate specification, or
subjected to power surges. The warranty does not include any labour or other
associated expense that may be involved in removal or installation of the product.
Normal wear and tear is expressly excluded.
If your Goldair product fails to operate satisfactorily, please return it to the retailer
from whom it was purchased. To obtain a repair or replacement product under this
warranty, you will need to produce satisfactory evidence of date of purchase. The
completed warranty and purchase receipt must be presented with the product. The
warranty should be filled out at the time of purchase. It is in your interest to make
sure this is done.
If the product is to be replaced (cannot be repaired) then that replacement will be of
the same or similar product or accessory excluding packaging, instruction card etc.
Where a replacement product is supplied, this shall be guaranteed for the balance of
the original warranty period.
Any model that is no longer available will be replaced by a model of a value and with
such features as we consider appropriate in the circumstances. Goldair Ltd is not
responsible for freight forwarding charges, losses or damage in transit.
If service is required after the warranty period has expired, the product should be
returned to a qualified electrical technician. Service outside of the warranty period
will be at your cost.
Consumers GuaranteeAct (1993).
In accordance with the above act consumers are advised that: The manufacturer
does not undertake that repair facilities and parts are necessarily available for this
product.
If any of the provisions of the foregoing are contrary to any relevant legislation, then
that provision shall be deemed to be excluded from the warranty and the rest of the
provisions will continue to apply.
TWO YEAR WARRANTY
IMPORTANT: PLEASE RETAIN THIS WARRANTY CARD
NAME:
ADDRESS:
PURCHASED FROM:
SUBURB:
DATE OF PURCHASE:
NAME OF PRODUCT:
MODEL No:
Table of contents
Other Goldair Heater manuals

Goldair
Goldair SELECT GSFH150 User manual

Goldair
Goldair GCV440 User manual

Goldair
Goldair GCT200 User manual

Goldair
Goldair GCT270 User manual

Goldair
Goldair Select GSCH250R User manual

Goldair
Goldair GECO200 User manual

Goldair
Goldair GCH500 User manual

Goldair
Goldair GCT325R User manual

Goldair
Goldair GMH230 User manual

Goldair
Goldair GCH220 User manual

Goldair
Goldair GMH150 User manual

Goldair
Goldair GCH210 User manual

Goldair
Goldair GCW220 User manual

Goldair
Goldair GOC167T User manual

Goldair
Goldair GSCH230 User manual

Goldair
Goldair Select GSCT100 User manual

Goldair
Goldair GCT260 User manual

Goldair
Goldair GCT430 User manual

Goldair
Goldair GECO200 User manual

Goldair
Goldair GCV100 User manual