CHARACTERISTICS
-Video door entry system with simplified wiring (non-polarised 2-wire bus).
-Up to 4 access panels (DP-GB2Adistributor required for more than one access panel) per installation.
-Up to 2 apartments per installation.
-Maximum 6 Vesta2 monitors or 4 Vesta7 monitors per installation.
-Maximum 4 monitors in parallel (without distributors) per installation.
-In installations with 1 apartment, maximum 6 Vesta2 monitors or 4 Vesta7 monitors.
-In installations with 2 apartments, maximum 6 Vesta2 monitors or 4 Vesta7 monitors.
-Combinations with Vesta2 monitors:
w1monitor in one apartment and 5 monitors in the other apartment.
w3monitors in each apartment.
-Combinations with Vesta7 monitors:
w1monitor in one apartment and 3 monitors in the other apartment.
w2monitors in each apartment.
-Visual signals on the door panel for people with impaired hearing (indicating call process, communication, door open
and channel busy).
-Door opening and auxiliary device activated for 5 seconds (configurable).
-DC lock release.
-Potential-free contact for activation of auxiliary devices (2nd AC lock release, gate, etc.); do not exceed values of
12Vdc/1Abetween terminals 'C1' and 'NA1' on the door panel.
-Input for exterior door opening button (output 'CV-' and 'CV+').
-Confirmation tone when the call button is pressed.
-DIP switches to configure door panel address, call mode, door panel with/without shield, type of contact/time for lock
release and auxiliary device output, card reader illumination mode and LED function mode (low light conditions).
-Maximum distance between the power supply and the furthest door panel: 65m with a cross-section of 1mm .
2
-Maximum distance between the power supply and the last distributor: 60m with a cross-section of 1mm .
2
-Maximum distance between distributor and monitor: 30m with a cross-section of 1mm .
2
SYSTEM OPERATION
3
SAFETY PRECAUTIONS
-Always disconnect the power supply before installing or making modifications to the devices.
-The fitting and handling of these devices must be carried out by .authorised personnel
-The wiring must run at least 40 cm away from any other wiring.
-On the power supply unit:
wDo not overtighten the screws on the connector.
wInstall the power supply unit in a dry protected location free from the risk of dripping or splashing water.
wAvoid locations that are humid, dusty or near heat sources.
wEnsure that the air vents are free from obstruction so that air can circulate freely.
wTo avoid damage, the power supply unit must be firmly secured in place.
wTo prevent electric shock, do not remove the cover or handle the wires connected to the terminals.
-To make a call, the visitor must press the button of the apartment; an audible sound indicates that the call is being
made and LED will turn on.At this moment, the apartment's monitors receive the call. If another apartment is called
by mistake, press the button for the correct apartment and the first call will be cancelled.
-In systems with several access doors, the other door panel(s) will be automatically disconnected. If another visitor
tries to call, a number of telephone tones will be heard to indicate that the system is busy and LED will illuminate.
-The call lasts for 40 seconds. The image appears on the monitor (with code 0 'apartment 1' or code 16 if the call is in
'apartment 2') when receiving the call without the visitor knowing.
If the call is not answered within 40 seconds, LED will turn off and the channel will be freed.
-To establish communication, press button on any monitor in the apartment. Door panel LED will turn on.
If the monitor is a VESTA2 GB2/H or VESTA7 GB2/H with icon on the front, make sure that the hearing aid is
between 15 and 25 cm away from the monitor to ensure maximum audio quality during communication with the
door panel.
-Communication will last for one and a half minutes or until button is pressed again. When communication has
finished, LEDs and will turn off and the channel will be freed.
-To open the door, press button during the call or communication processes: one press will activate the lock release
for five seconds and LED will also turn on for five seconds.
-To activate the auxiliary device output, press button on the Vesta7 monitor or via the Vesta2 monitor's lock release
menu 2 (for lock release 2, it is necessary to enable lock release function 2 on the Vesta2 monitor) during call or
communication processes: a single press activates the auxiliary device output for five seconds, LED will also
illuminate for five seconds.
-For a description of the functioning and setup of the monitor, see the monitor's user manual.