golmar TKIT632 User manual

USER MANUAL
Code 50121904 T ENKIT632 THERA REV.0 11 6
G 2 Video Door EntryB
System Kit
2-wire installation
Stainless Steel
Nexa Modular

INTRODUCTION
First and foremost we would like to thank you for purchasing this product.
Our commitment to satisfying our customers can be seen from our ISO-9001 certification and from the manufacturing of
products like this one.
Its advanced technology and exacting quality control will ensure that customers and users enjoy the many features this
system offers. To obtain the maximum benefit from these features and a properly wired installation, we kindly
recommend that you spend a few minutes of your time reading this manual.
CONTENTS
2
SET-UP WARNINGS
- Do not use excessive force when tightening the power supply connection block screws.
-Always disconnect the power supply before installing or making modifications to the devices.
- The fitting and handling of these devices must be carried out by .authorised personnel
- The wiring must run at least 40 cm away from any other wiring installations.
- Before connecting the device to the mains, check the connections between the door panel, power supply, distributors,
camera unit, GSM interface, monitors and telephones.
- Use Golmar cable (2x1mm ).RAP-2150
- Always follow the instructions contained in this manual.
Introduc ....................................................................................................................................................................2tion
Contents.........................................................................................................................................................................2
Set-up warnings............................................. ................................................................................... 2............................. .
Safety precautions............................................................................................................................................ .3.............
Characteristics............................................................................................................................................................... 3.
System operation............................................. .............................................................................................. 3................ .
Description of the EL632/GB2 sound module..................................................................................................................4
Stainless Steel Nexa Modular Door Panel.........................................................................................................................
................................. ..................................................................................................5..Positioning the embedding box
........................................................................ ................................... ..................5................ .Preparing the cable entry
........................................................ .............................. ...................6...................... . .Codes assigned to the call buttons
................................................................... ......................................6............Description of the configuration dip switch
................................................................................................................. ......7..Description of the configuration jumper
........................................................................ .....7............................Description of the LED lights (low light conditions)
.................... .................................... ..................................... ..7.. . .Description of the visual indications on the door panel
......................................................................7Description of the vocal synthesis (audible indications on the door panel)
A ................... .......................................................................................8.djusting the door panel communication volume
A .......................................................................................................................... .8.djusting the vocal synthesis volume
S ............................................................................................................ ..........8...electing the vocal synthesis language
C ...............................................................................9.onfiguring the contact type for Relay 1 and Relay 2 (lock release)
.................................................................................. ......9........................Inserting the push button identification labels
..................................................................................................................................................9Closing the door panel
FA-GB2/A power supply installation................................................................................................................... ........10....
Lock release installation..................................................................................................................................... ......10..... ..
Wiring diagrams...................................................................................................................................... ...11-18..............
Not s............................................................................................................................................................................19e
2
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

CHARACTERISTICS
- Video door entry system with simplified installation (non-polarised 2 wire bus).
- AUp to 4 access panels (DP-GB2 distributor required for more than one access panel) per installation.
- Up to 2 apartments (NX5110 1-apartment kit and NX5220 2-apartment kit) per installation.
- Maximum 18 Thera monitors per installation.
- Maximum 16 Thera monitors in one apartment.
- Maximum 4 Thera monitors in parallel (without distributors) per installation.
- Installation with Thera monitors (FA-GB2/A power supply required).
- Call confirmation tone.
- Visual indications on the door panel for people with impaired hearing (indicating call process, communication, door
open and channel busy).
- Audible indications on the door panel for people with impaired vision (indicating call in progress, missed call, door open,
call finished and engaged).
- Door opening timeable at 1 or 5 seconds.
- 2 outputs for independently activated lock releases.
- Relay 1 output to activate the DC orAC lock releases actuated by relay.
- Relay 2 output to activate the DC orAC lock releases actuated by relay.
- Input for external door opening button (Relay 1 output).
- Input for external door opening button (Relay 2 output).
- Maximum distance between the power supply and the furthest door panel: 80m with a cross-section of 1mm .
- .Maximum distance between the power supply and the last distributor: 80m with a cross-section of 1mm
- Maximum distance between the distributor and monitor: 40m with a cross-section of 1mm .
SYSTEM OPERATION
- To make a call, the visitor must press the button of the apartment; an audible sound indicates that the call is being
made and LED will turn on. If vocal synthesis is enabled, a “Call is in progress” message appears to indicate a call
is being made. At this moment the apartment's monitor(s) receives the call. During the call the visitor can correct his
call by pressing a push button corresponding to a different apartment, in which case the original call is cancelled.
- In systems with several access doors, the other door panel(s) will be automatically disconnected. If another visitor
tries to call, a telephone tones will be heard to indicate that the system is busy and LED will illuminate. If vocal
synthesis is activated, the message “System is busy, try later” will be indicated on the door panel.
- The call lasts for 40 seconds. The image appears on the monitor (with code 0 “apartment 1” or monitor 16 if the call is in
“apartment 2”) when receiving the call without the visitor knowing.
If the call is not answered within 40 seconds, LED will turn off and the channel will be freed.
- To establish communication, press push button on any monitor in the apartment. Door panel LED will turn on.
If the vocal synthesis is enabled the message “you can speak now” will be eard confirming the communication ish
activated.
- Communication will last for one and a half minutes or until push button is pressed again. When communication
has finished, LEDs and will turn off and the channel will be freed. If vocal synthesis is activated, a
“Communication is finished” message will indicate that the call is over on the door panel.
- To open the door, press push button during the call or communication processes: one press will activate the lock
release for five seconds and LED will also turn on for five seconds. If vocal synthesis is activated, a “Door pen”is o
message will be indicated on the door panel.
- .For a description of the functioning and setup of the monitor, see the monitor's user manual
3
2
2
2
SAFETY PRECAUTIONS
-Always disconnect the power supply before installing or making modifications to the devices.
- The fitting and handling of these devices must be carried out by .authorised personnel
- The wiring must run at least .40 cm away from any other wiring
- :In the power supply unit
wDo not overtighten the screws on the connection block.
wInstall the power supply in a dry and protected place free from the risk of water leaks or sprays.
wAvoid locations that are humid, dusty or near heat sources.
wEnsure that the air vents are free from obstruction so that air can circulate freely.
wTo avoid damage, the power supply must be firmly secured in place.
wTo prevent electric shock, do not remove the cover or handle the wiring connected to the terminals.
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

DESCRIPTION OF THE EL632/GB2 SOUND MODULE
4
Microphone.
Speaker.
Front.
Sound module push buttons (x2).
Connection block (GB2 bus).
Push button connector (in unused).villas
Back.
: releasePositive, negative (12Vdc output for Golmar DC lock ).
: Contact "C" for lock (Relay 1).release
: Contact "NO" for lock (Relay 1).release
: Input for external door opening button (Relay 1).
: Contact "NO" for lock (Relay 2).release
: Contact "C" for lock (Relay 2).release
: Input for external door opening button (Relay 2).
: Input for external call button (push button 1).
: Input for external call button (push button 2).
: Connection BUS (non-polarised).
:Connection BUS (non-polarised).
Push button number.
Color camera.
+,
C1
NA1
AP ,AP+
NA2
C2
AP+,AP
P1
P2
BUS
BUS
_
Connection terminals:
Note: See wiring diagrams for connections (pages 11-18).
Configuration DIP switch.
Internal use.
LEDs (visual indications for people with impaired hearing).
LEDs (activation in low light conditions).
1 2 3 4 5 6
ON
Internal use.
_
_
Do not use (internal use).
Description of the EL632/GB2 sound module:
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

5
CE-610 : 125( ) x 140( ) x 56( ) mm.W H Dembedding box
1650
1850
1450
Make a hole in the wall to position the top of the door panel at a height of 1.65 m.
Hole dimensions:
The door panel has been designed to be used under most environmental conditions. It is however advisable to
take extra precautions to prolong its service life (shields, covered areas, etc.).
To obtain optimum video door entry system image quality, avoid direct contact from light sources (sunshine,
street lights, etc.).
Positioning the embedding box:
DOOR PANEL INSTALLATION
Preparing the cable entry:
Break through the hole to allow the entry of the cable
into the bottom section of the embedding box.
Pass the cable through the hole made in
.the embedding box
Embed the box and ensure that it is level and flush.
Once embedded, remove the protective
stickers from the screw holes.
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

6
DOOR PANEL INSTALLATION
Codes assigned to the call buttons of the sound module:
1 2 3 4 5 6
ON
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relé 2
Relé 1
_
12Vdc
12
EL632/GB2
C 16 31odes - C 0 15odes -
P1P2 P2
The sound module's P1 and P2 push buttons are assigned with factory codes.
-Apartment 1, push button “P1”:Assigned with codes 0-15.
Monitors in this apartment must be set with codes in order of allocation of 0-15.
When push button “P1”on the door panel is pressed, all of the monitors in apartment 1 will receive the call and
only the monitor assigned with code 0 will show the door panel image. If the call is answered from any other
monitor in the apartment, the image on the monitor assigned with code 0 will disappear and audio and video
communication will be established with the door panel.
-Apartment 2, push button “P2”:Assigned with codes 16-31 ( .only kits with 2 push buttons)
Monitors in this apartment must be set with codes in order of allocation of 16-31.
When push button “P2”on the door panel is pressed, all of the monitors in apartment 2 will receive the call and
only the monitor assigned with code 16 will show the door panel image. If the call is answered from any other
monitor in the apartment, the image on the monitor assigned with code 0 will disappear and audio and video
communication will be established with the door panel.
C s 16 31ode -
Description of the configuration dip switch of the sound module:
1 2 3 4 5 6
ON
+C1
_
1
The configuration dip switch is located on the left side of the rear part of the
module.
1 2 3 4 5 6
ON
Door Panel Address:
Dip switches: 1 and 2 OFF (address 1), 1 ON and 2 OFF (address 2), 1 OFF and
2 ON (address 3), 1 and 2 ON (address 4).
1 2 4 5 6
3
ON
Leave OFF.
1 2 3 5 6
4
ON
Set to OFF for use with door panels in and set to ON for use in apartmentvillas
buildings.
1 2 3 4 6
5
ON
Set to ON to con#gure the door release time to 5 seconds. Set to OFF to
con#gure the door release time to 1 second.
1 2 3 4 5 6
ON
Set to ON to con#gure: (see page 8-9)
The vocal synthesis language (using the sound module's P1 push button).
Relay 1 and Relay 2 of the lock release will be NO or NC (using the sound
module's P2 push button). Set to OFF when con#guring is complete.
*
( )
*
( ) Factory default setting.
*
( )
*
( )
*
( )
*
( )
*
( )
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

7
DOOR PANEL INSTALLATION
Description of the configuration jumper:
1 2 3 4 5 6
ON
+C1
_
1
Important:Do not change the factory default position of the configuration jumper.
Description of the door panel LED lights (for low light conditions):
The door panel LED lights will turn on during a call if there is low light, allowing the
person who called to be seen on the apartment's monitor.
*
( )
*
( ) Factory default setting.
Description of the visual indications on the door panel:
Visual indications on the door panel for people with impaired hearing:
- .While calling: LED “ ” will turn on during the call and while in communication
- During communication: LED “ ” will turn on during the communication process.
- During door release: LED “ ” will turn on during door release.
- End of communication: LEDs “ ” and “ ” will turn off.
- Calling at one door panel while another door panel is communicating (if there is more than one door panel):
LED “ ” will turn on for 3 seconds..
- While calling and the monitor is in “Do not disturb”mode: LED “ ” will turn on for 4 seconds.
- While calling (apartment with no monitor or telephone): LED “ ” will turn on for 4 seconds.
Description of the vocal synthesis (audible indications on the door panel):
Audible indications from the door panel for people with impaired vision.
If the vocal synthesis in the sound module is activated (see pages 6 and 8 for setup),
a voice with the following messages can be heard from the door panel:
- is in progressWhile calling: “Call ”
- isDuring door release: “Door open”.
- ommunication is #nishedEnd of communication: “C”.
- Calling at one door panel while another door panel is communicating
(if there is more than one door panel): “ ”.System is busy, try later
- Resident UnavailableWhile calling and the monitor is in "Do not disturb" mode: “ ”.
- Resident UnavailableWhile calling (apartment with no monitor or telephone): “ ”.
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

8
DOOR PANEL INSTALLATION
Adjusting the door panel communication volume:
If after starting the system the door panel audio volume seems inadequate, follow these steps:
- Call an apartment.
- The call is received in the apartment. Establish communication by pressing the push button on the monitor.
- Next, press the push button used to call the apartment for 3 seconds until a number of con#rmation tones are
heard and the door panel communication LED starts to blink.
- Each press on the same call button will increase the door panel volume and LED blink speed.
.
There are 5 volume settings and the blink speed of LED will increase for each. Slow to fast blink - low to
high volume. After reaching “setting 5”, that is, maximum blink speed and volume, the next setting is
“setting 1”, that is, minimum blink speed and volume (carousel mode).
- To save the volume setting keep the push button used to call the apartment pressed until a number of
con#rmation tones are heard and the door panel communication LED turns off.
Adjusting the vocal synthesis volume:
If after starting the system the vocal synthesis volume of the door panel seems inadequate, follow these steps:
- Within 10 seconds of connecting power to the door panel press any call push button on the door panel.
- Keep the call push button pressed until the vocal synthesis volume is heard and door panel LED starts to
blink.
- Each press on the same call push button will increase the vocal synthesis volume and the blink speed of LED .
There are 5 volume settings and the blink speed of LED will increase for each. Slow to fast blink - low to
high volume. After reaching “setting 5”, that is, maximum blink speed and volume, the next setting is “setting
1”, that is, minimum blink speed and synthesiser volume (carousel mode).
- To save the volume setting keep the push button used to call the apartment pressed until a number of
con#rmation tones are heard and the door panel communication LED turns off.
Selecting the vocal synthesis language:
To activate the vocal synthesis of the door panel, follow these steps:
- Set dip 6 of the sound module's con#guration dip switch to ON (see page 6), a
con#rmation tone will be heard.
- The desired language can be set using the sound module's P1 push button.
- Each press will change the language. Continue doing this until the desired language is
heard.
- .Once #nished set dip 6 on the con#guration dip switch to OFF
A con#rmation tone will be heard.
P1
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

9
DOOR PANEL INSTALLATION
Configuring the contact type for Relay 1 and Relay 2 (lock release):
To change the contact type for lock release activation of Relay 1 and Relay 2 of the door
panel, follow these steps:
- Set dip 6 of the sound module's con#guration dip switch to ON (see page 6), a
con#rmation tone will be heard.
- Use the sound module's P2 push button to select the desired contact type (N.O
factory default or N.C).
- Each press will change the contact type. A long con#rmation tone will be heard if the
selected contact is N.O or two short tones if the selected contact is N.C. Stop pressing
P2 when the desired tone is heard.
- Once #nished set dip 6 on the con#guration dip switch to OFF.
A con#rmation tone will be heard.
P2
Inserting the push button identification labels:
Open the label holder.
Insert the label
and close.
Important:The selected contact type will apply to both Relay 1 and Relay 2.
Description:
Normally open: N.O.
Normally closed: N.C.
Closing the door panel:
Once the door panel has been correctly wired, configured
and adjusted, fix it to the embedding box using the
tamper-proof screws and ¼”tamper-proof screwdriver bit
supplied.
Important:
- .
Before closing the door panel, make a test call to any apartment to ensure that everything works correctly
- .Keep the tamper-proof screwdriver bit in a safe place in case the door panel needs to be reopened
To insert the push button identi#cation labels, remove the sound module from the door panel to access the label
holder and use a $at screwdriver to gently lever open the fastening clips, as shown in drawing A . Once the
identi#cation labels have been inserted, reattach the sound module to the door panel. Line up the tabs on the sound
module with their respective fastening clips and then press gently until correctly positioned.
*
( )
A
Fastening clips (x4).
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

10
POWER SUPPLY INSTALLATION
FA-GB2/A power supply installation instructions:
M 4 x 8
3,5 x 25
DIN-7972
DIN-963
Replace the protective cover once the input terminals have been wired.
Please note that current regulations stipulate that the
power supply must be protected by a thermo-
magnetic circuit breaker.
Connect the FA-GB2/A power supply to the earth
connection.
Mount the DIN rail to the wall with the plugs and screws
supplied.
Then attach the power supply by applying slight pressure.
The power supply can be installed on a DIN 46277 rail.
.
To remove the power supply from the DIN rail, use a flat
screwdriver to lever it off, as shown in the drawing.
The FA-GB2/A model requires 8 elements on the rail.
IMPORTANT: the maximum number of units that can be connected to an FA-GB2/A power supply is 18
THERAGB2 monitors.
The FA-GB2/A power supply has been specially designed for the GB2 video door entry system with Golmar
Thera monitors.
Install the power supply in a dry and protected place free from the risk of water .drip or projections
To prevent electric shock, do not remove the protective cover of the primary or handle the wiring.
The and handling of this device must be carried out by authorised personnel in the absence ofinstallation
electrical current.
To avoid damage, the power supply firmly .has to be fixed
IMPORTANT:
- )The lock release must be 12VAC or DC (Golmar .
( )See page 18 forAC lock releases and pages 11-18 for DC lock releases .
- The kit is supplied with two varistors. If connecting an AC lock release to one of the outputs, fit the varistor
supplied directly to the lock release terminals to ensure the device functions correctly.
If the lock release is to be fitted to a metal door, use a Ø3.5mm drill bit and
thread the hole made For wooden doors, use a Ø3mm drill bit.
.
Lock release installation instructions:
LOCK RELEASE INSTALLATION
DIN rail
DIN rail
DIN rail
DIN 46277
DIN rail latch release
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

WIRING DIAGRAMS:
One apartment kit (NX5110 THERA kit) and Golmar DC lock release.
11
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
Lock release
max. 12 Vdc/270mA
N L
CN
Mains
100~240Vac
BUS (M) BUS (PL)
FA- 2GB /A
ON
1 2 3 4 5 6
AP
SW1
( )1
( )1
Access paneldoor
THERA
BUS
CODE 0
Two apartment kit (NX5220 THERA kit) and Golmar DC lock release.
Configuring the end of line
in the last monitor.
.Dip 6 to On
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
Lock release
max. 12 Vdc/270mA
ON
1 2 3 4 5 6
*
AP
SW1
( )1
( )1
Important: For AC lock releases or a second lock release, see diagram “Connection of Golmar AC and DC lock releases”on page 18.
( )1
Access paneldoor
BUS
CODE 0
Distances and Cross-Sections:
Twisted pair 2x0.75mm2
Twisted pair mm2x1 2
60m
A
60m
B
10m
C
80m 80m 15m
Cable
BUS
CODE 16
FA- 2GB /A
A
B
C
APARTMENT 1APARTMENT 2
*
*
Configuring the end of line
in the last monitor.
.Dip 6 to On
*
Distances and Cross-Sections:
FA- 2GB /A
A
B
Twisted pair 2x0.75mm2
Twisted pair 2x mm1 2
60m
A
60m
B
10m
C
80m 80m 15m
Cable
C
APARTMENT 1
THERA
THERATHERA
THERA
THERA
L
N L
CN
Mains
100~240Vac
BUS (M) BUS (PL)
FA- 2GB /A
L
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

WIRING DIAGRAMS:
One apartment kit (NX5110 THERA kit) with monitors in parallel (In-Out) and Golmar DC lock release.
12
Two apartment kit (NX5 0 THERA kit) with monitors in parallel (In-Out) and Golmar DC lock release.22
Configuring the end of line
in the last monitor.
.Dip 6 to On
*
Important: For AC lock releases or a second lock release, see diagram “Connection of Golmar AC and DC lock releases”on page 18.
( )1
Distances and Cross-Sections:
Twisted pair 2x0.75mm2
Twisted pair 2x mm1 2
60m
A
60m
B
10m
C
80m 80m 15m
Cable
Configuring the end of line
in the last monitor.
.Dip 6 to On
*
Twisted pair 2x0.75mm2
Twisted pair 2x mm1 2
60m
A
60m
B
10m
C
80m 80m 15m
Cable
Distances and Cross-Sections:
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
Lock release
max. 12 Vdc/270mA
ON
1 2 3 4 5 6
AP
SW1
( )1
( )1
BUS
CODE 1
BUS
CODE 2
BUS
CODE 3
BUS
CODE 0
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
Lock release
max. 12 Vdc/270mA
ON
1 2 3 4 5 6
AP
SW1
( )1
( )1
BUS
CODE 1
BUS
CODE 16
BUS
CODE 17
BUS
CODE 0
APARTMENT 1APARTMENT 2
*
*
IMPORTANT: Maximum 4 monitors in parallel (without distributors) per installation.
IMPORTANT: Maximum 4 monitors in parallel (without distributors) per installation.
APARTMENT 1
N L
CN
Mains
100~240Vac
BUS (M) BUS (PL)
FA- 2GB /A
L
N L
CN
Mains
100~240Vac
BUS (M) BUS (PL)
FA- 2GB /A
L
THERATHERATHERATHERA
Access paneldoor
THERATHERATHERATHERA
A
B
C
FA- 2GB /A
THERA
THERA Access paneldoor
A
B
C
FA- 2GB /A
THERA
THERA
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

WIRING DIAGRAMS:
One apartment with 16 THERA monitors, 4 DP-GB2 distributors and Golmar DC lock release.A
13
Configuring the end of line
in the last monitor.
.Dip 6 to On
Access paneldoor
**
Lock release
max. 12 Vdc/270mA
BUS
BUS
BUS
BUS
BUS BUS
BUS BUS
D
C
B
A
DP- 2GB A
BUS
BUS
End of line
ON
End of line
OFF
CODE 3 CODE 2
CODE 1 CODE 0
CODE 13 CODE 12
** **
** **
** **
Configuring the end of line
in the last distributor.
Switch to On.
*
*
AP
Distances and Cross-Sections:
DP-GB2A
A
C
B
C
Important: For AC lock releases or a second lock release, see diagram “Connection of Golmar AC and DC lock releases”on page 18.
(1)
(1)
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
ON
1 2 3 4 5 6
SW1
(1)
BUS BUS
BUS BUS
D
C
B
A
DP- 2GB A
D
Twisted pair 2x0.75mm2
Twisted pair 2x mm1 2
60m
A
60m
B
30m
C
80m 80m 40m
Cable
10m
D
15m
THERA
THERA
THERA
THERA
THERA THERA
FA- 2GB /A
THERA THERA
N L
CN
Mains
100~240Vac
BUS (M) BUS (PL)
FA- 2GB /A
L
BUS
BUS
CODE 15 CODE 14
** **
THERA THERA
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

WIRING DIAGRAMS:
One apartment with 16 THERA monitors, 8 D2L-GB2 distributors and Golmar DC lock release.
14
Configuring the end of line
in the last monitor.
.Dip 6 to On
**
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
Lock release
max. 12 Vdc/270mA
BUS BUS
BUS BUS
D2
D1
D2L- 2GB
ON
1 2 3 4 5 6
BUS
BUS
BUS BUS
BUS BUS
D2
D1
D2L-GB2
BUS
End of line
ON
CODE 3 CODE 2
** **
Remove the jumper from all
of the distributors except
the last.
*
*
AP
SW1
BUS BUS
BUS BUS
D2
D1
D2L- 2GB
BUS
BUS
CODE 1 CODE 0
** **
Do not change the factory
default position of the
configuration jumper.
(1)
OFF
(1)
End of line
OFF
End of line
(1)
(1)
Distances and Cross-Sections:
(2)
(2)
Twisted pair 2x0.75mm2
Twisted pair 2x mm1 2
60m
A
60m
B
30m
C
80m 80m 40m
Cable
10m
D
15m
Important: For AC lock releases or a second lock release, see diagram “Connection of Golmar AC and DC lock releases”on page 18.
( )2
CODE 15
**
Access paneldoor
THERA
THERA THERA
THERA THERA
D -2L GB2
A
C
B
C
D
FA- 2GB /A
THERA THERA
N L
CN
Mains
100~240Vac
BUS (M) BUS (PL)
FA- 2GB /A
L
BUS
CODE 14
**
THERA
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

WIRING DIAGRAMS:
Two apartments with 18 THERA monitors, 5 DP-GB2 distributors and Golmar DC lock release.A
15
Configuring the end of line
in the last monitor.
.Dip 6 to On
**
Lock release
max. 12 Vdc/270mA
BUS
BUS
BUS BUS
BUS BUS
D
C
B
A
DP- 2GB A
BUS
End of line
End of line
OFF
CODE 3
CODE 0
CODE 8
**
**
**
Configuring the end of line
in the last distributor.
Switch to On.
*
AP
Distances and Cross-Sections:
DP-GB2A
A
C
B
C
Important: For AC lock releases or a second lock release, see diagram “Connection of Golmar AC and DC lock releases”on page 18.
(1)
(1)
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
ON
1 2 3 4 5 6
SW1
(1)
BUS BUS
BUS BUS
D
C
B
A
DP- 2GB A
D
Twisted pair 2x0.75mm2
Twisted pair 2x mm1 2
60m
A
60m
B
30m
C
80m 80m 40m
Cable
10m
D
15m
MONITOR 1
MONITOR 2
**
**
BUS
BUS BUS
BUS BUS
D
C
B
A
DP- 2GB A
BUS
BUS
End of line
End of line
CODE 24
CODE 16
CODE 19
**
**
**
*
BUS BUS
BUS BUS
D
C
B
A
DP- 2GB A
MONITOR 18
MONITOR 17
**
**
OFF
ON
OFF
APARTMENT 2APARTMENT 1
N L
CN
Mains
100~240Vac
BUS (M) BUS (PL)
FA- 2GB /A
L
THERA
THERA THERA
THERA THERA
THERA
FA- 2GB /A
THERA THERA
Access paneldoor
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

WIRING DIAGRAMS:
Two apartments with 18 THERA monitors, 9 D2L-GB2 distributors and Golmar DC lock release.
16
Configuring the end of line
in the last monitor.
.Dip 6 to On
**
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
Lock release
max. 12 Vdc/270mA
ON
1 2 3 4 5 6
BUS BUS
BUS BUS
D2
D1
D2L-GB2
Remove the jumper from all
of the distributors except
the last.
*
AP
SW1
BUS BUS
BUS BUS
D2
D1
D2L- 2GB
Do not change the factory
default position of the
configuration jumper.
(1)
OFF
(1)
End of line
(1)
Distances and Cross-Sections:
D2L- 2GB
A
C
B
C
(2)
(2)
Twisted pair 2x0.75mm2
Twisted pair 2x mm1 2
60m
A
60m
B
30m
C
80m 80m 40m
Cable
10m
D
15m
D
Important: For AC lock releases or a second lock release, see diagram “Connection of Golmar AC and DC lock releases”on page 18.
( )2
BUS
BUS BUS
CODE 1
CODE 0
CODE 8
**
**
**
BUS BUS
BUS
CODE 24
CODE 16
CODE 17
**
**
**
APARTMENT 2
BUS BUS
BUS BUS
D2
D1
D2L-GB2
End of line
ON
*
BUS BUS
BUS BUS
D2
D1
D2L- 2GB
(1)
OFF
End of line
(1) OFF
End of line
THERA
THERA
THERA
THERA
THERA
THERA
N L
CN
Mains
100~240Vac
BUS (M) BUS (PL)
FA- 2GB /A
L
Access paneldoor
FA- 2GB /A
THERA THERA
APARTMENT 1
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

WIRING DIAGRAMS:
17
BUSBUS
BUS BUS
D C B A
DP- 2GB A
End of line
OFF
AP AP
Access paneldoor 2
ON
1 2 3 4 5 6
SW1
Access paneldoor 1
ON
1 2 3 4 5 6
SW1
AP AP
Access paneldoor 3
ON
1 2 3 4 5 6
SW1
Access paneldoor 4
ON
1 2 3 4 5 6
SW1
(1) (1)
(1) (1)
To the distributors (building floors)
Lock release
max. 12 Vdc/270mA
Lock release
max. 12 Vdc/270mA
Lock release
max. 12 Vdc/270mA
Lock release
max. 12 Vdc/270mA
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
Important: .For AC lock releases or a second lock release, see diagram “Connection of Golmar AC and DC lock releases”on page 18
(1) (1)
(1) (1)
(1)
Video door entry system with 4 access panels, DP- distributor for door panels and Golmar DC lock release.GB2A
N L
CN
Mains
100~240Vac
BUS (M) BUS (PL)
FA- 2GB /A
L
óó
óó
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

Access paneldoor
ON
1 2 3 4 5 6
SW1
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
_
AP1
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2Relay 1
_
12Vdc
Connection of 2 DC lock releases without “AP”:
Important: .With 2 DC lock releases, it is not possible to use the “AP”door opening buttons
(1)
Mains
230Vac
SEC
~~ ~~
PRI
TF-104
Lock release
ac 850max. 12 V / mA
Connection of 1 AC lock release with “AP”:
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2Relay 1
_
12Vdc
(1)
To the FA-GB2/A
power supply
(1)
Lock release
max. 12 Vdc/270mA
Connection of 2 AC lock release with “AP”:
SEC PRI
TF-104
Access paneldoor
ON
1 2 3 4 5 6
SW1
Access paneldoor
ON
1 2 3 4 5 6
SW1
WIRING DIAGRAMS:
18
Relay 2Relay 1
12Vdc
Lock release
ac 850max. 12 V / mA
~~ ~~
AP1 AP2
Mains
230Vac
Connection of Golmar AC and DC lock releases.
ó
ó
To the FA-GB2/A
power supply
ó
To the FA-GB2/A
power supply
Important: Fit the varistor supplied with the kit directly to the terminals of the lock release.
Important: Fit the varistor supplied with the kit directly to the terminals of each of the 2 lock releases.
*
*
*
*
*
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

NOT S:E
19
STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

golmar@golmar.es
www.golmar.es
Sistemas de comunicación S.A.
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis .
Golmar reserves the right to make any modifications without prior notice.
Table of contents
Other golmar Intercom System manuals

golmar
golmar 2PLUS User manual

golmar
golmar T500EN User manual

golmar
golmar Jazz GB2 User manual

golmar
golmar GCALL Use and care manual

golmar
golmar ART 1 G2+ User manual

golmar
golmar 7403/IP User manual

golmar
golmar G2+ SOUL S5110/ART 7H User manual

golmar
golmar Jazz GB2 User manual

golmar
golmar AS-1220 SII User manual

golmar
golmar VESTA7 SE GB2 User manual

golmar
golmar V2PLUS User manual

golmar
golmar 50124319 User manual

golmar
golmar Tekna HF Plus User manual

golmar
golmar G2+ Soul S5110 Art 4 User manual

golmar
golmar T4ML User manual

golmar
golmar T222ML User manual

golmar
golmar G2+ User manual

golmar
golmar GB2A User manual

golmar
golmar ART 4/G2+ Monitor User manual

golmar
golmar SV-370S User manual