golmar CODEPROX-N User guide

IM_ENG_REV0122_CODEPROX-N
INSTALLER
MANUAL
CODEPROX-N

2
CODEPROX-N
www.golmar-seguridad.es
1.INDEX
1.Index .................................................................................................................................................................2
2.Introduction .....................................................................................................................................................3
3.Specications ....................................................................................................................................................3
4.Product content ................................................................................................................................................3
5.Installation ........................................................................................................................................................3
6.Connection .......................................................................................................................................................4
7.Standalone connection diagram........................................................................................................................4
8.Basic programming ...........................................................................................................................................4
8.1.User registration....................................................................................................................................................... 4
8.2.User deletion............................................................................................................................................................ 5
8.3.Basic programming with master card ..................................................................................................................... 5
9.Advanced programming ...................................................................................................................................6
9.1.Programming .......................................................................................................................................................... 6
9.1.1.Change master code ........................................................................................................................................ 6
9.1.2.Card registration (auto ID).............................................................................................................................. 6
9.1.3.Card registration (specic ID)......................................................................................................................... 6
9.1.4.PIN registration (auto ID) ............................................................................................................................... 6
9.1.5.PIN registration (specic ID) ......................................................................................................................... 6
9.1.6.PIN deletion .................................................................................................................................................... 6
9.1.7.Card deletion .................................................................................................................................................. 7
9.1.8.Deleting cards or PIN (specic ID) ................................................................................................................. 7
9.1.9.Modify PIN...................................................................................................................................................... 7
10.Other settings..................................................................................................................................................7
10.1.Identication mode................................................................................................................................................ 7
10.1.1.Identication by card or PIN......................................................................................................................... 7
10.1.2.Identication by card only............................................................................................................................. 7
10.2.Alarm settings (tamper)......................................................................................................................................... 7
10.2.1.Activate tamper ............................................................................................................................................. 7
10.3.Relay settings.......................................................................................................................................................... 7
10.3.1.Pulse mode .................................................................................................................................................... 7
10.3.2.Latching mode............................................................................................................................................... 7
10.4.Lockout alarm ....................................................................................................................................................... 8
10.4.1.Lockout disabled............................................................................................................................................ 8
10.4.2.10-minute access lockout............................................................................................................................... 8
10.4.3.Alarm............................................................................................................................................................. 8
10.4.Reset to factory defaults ......................................................................................................................................... 8
10.5.Deletion of all users................................................................................................................................................ 8
11.Status displays..................................................................................................................................................8
12.Connection diagram with video door system.................................................................................................9
13.Wiegand ..........................................................................................................................................................9
13.1.Connection diagram .............................................................................................................................................. 9

3
CODEPROX-N
www.golmar-seguridad.es
2.INTRODUCTION
4.PRODUCT CONTENT
Installation manual for CODEPROX-N reader. Proximity and PIN reader for stand-alone and slave operation.
3.SPECIFICATIONS
Material Stainless steel and black ABS plastic
Protection degree IP-66
Input voltage 12/18Vdc
Current Standby current: ≤ 30mA / Active: ≤ 120mA
Capacity 990 users
Keypad 12 keys
Reading frequency EM 125KHz
Reading range 0-6cm
Relay NO, NC, common
2A max.
Transmission format Wiegand 26
Dimension (H x W x D): Electronics: 48(W) x 62(H) x 25(D)mm.
Electronics plus front cover: 86(W) x 86(H) x 25(D)mm
Working temperature range: -40 ~60° C
Working humidity range: 10-98% (non-condensing)
Lector CODEPROX-N
Diode.
Fixing blocks.
Screws.
Screw cover labels.
12 3
45 6
78 9
*0 #
13.2.Programming ........................................................................................................................................................ 10
13.2.1.Programming card ........................................................................................................................................ 10
13.2.2.Programming PIN ......................................................................................................................................... 11
14.Types of installation ........................................................................................................................................11
14.1. Stand-alone installation................................................................................................................................... 11
14.2.Installation on Nexa panel................................................................................................................................ 12
5.INSTALLATION
is reader is intended for mounting/integration in Nexa panels, which requires the use of an adapter module.
However, it can also be mounted independently on a specic embedding box (universal embedding box is not valid).
See chapter “14. TYPES OF INSTALLATION” to proceed.

4
CODEPROX-N
www.golmar-seguridad.es
6.CONNECTION
7.STANDALONE CONNECTION DIAGRAM
WIRE COLOR FUNCTION DESCRIPTION
Red 12Vdc Input 12-18V DC current
Black GND GND
Blue NO Normally open relay output
Brown Common Common contact for relay output
Grey NC Normally closed relay output
Ye l l o w Opening Exit pushbutton
Green D0 Wiegand Data 0 output
White D1 Wiegand Data 1 output
NC
COM
NO
OPEN
GND
D1
DO
Blue
Grey
Brown
Red
Yellow
Green
Black
+12V DC
White
+12V
GND
1N4004
12 3
45 6
78 9
*0 #
IMPORTANT: Do not forget to connect the supplied diode (1N4004) in parallel to the lock release to protect the equipment.
8.BASIC PROGRAMMING
Basic programming (user registration/deletion):
8.1. USER REGISTRATION
12 3
45 6
78 9
*0 #
Master code
(by default: 123456)
12 3
45 6
78 9
*0 #
#
12 3
45 6
78 9
*0 #
1
12 3
45 6
78 9
*0 #
Sistemas de comunicación S.A.
Approach card
to the reader
12 3
45 6
78 9
*0 #
Master code
(by default 123456)
12 3
45 6
78 9
*0 #
#
12 3
45 6
78 9
*0 #
PIN
(ac�va�on code
4-digit)
12 3
45 6
78 9
*0 #
#
12 3
45 6
78 9
*0 #
1
CARD
REGISTRATION
PIN
REGISTRATION

5
CODEPROX-N
www.golmar-seguridad.es
It is possible to perform basic programming using a MASTER card. To do this, a MASTER card must be created by following the procedure
described in chapter “10.4. Reset to factory settings”.
Once the MASTER card has been created, you can proceed as described below to perform basic programming:
USER DELETION
USER REGISTRATION
1) Approach the “Master Card” card to the reader. 1) Approach the “Master Card” card to the reader 2 times at
an interval shorter than 5 seconds.
3) Approach the “Master Card” card to the reader. 3) Approach the “Master Card” card to the reader.
2) Approach the card or enter PIN to register.
*For PIN enter 4 to 6 digit PIN plus #. 2) Approach card or enter PIN to delete.
*For PIN enter 4 to 6 digit PIN plus #.
NOTE
In case of loss of the MASTER CARD it is possible to replace the previous one by performing again the process described in chapter “10.4.Reset
to factory settings”.
12 3
45 6
78 9
*0 #
Master card
(To Add user)
Read Master Card
Read User (Card)/
(PIN#)/(fingerprint 3 �mes)
Read Master Card Again
12 3
45 6
78 9
*0 #
Master card
(To Add user)
Read Master Card
Read User (Card)/
(PIN#)/(fingerprint 3 �mes)
Read Master Card Again
12 3
45 6
78 9
*0 #
Master card
(To Add user)
Read Master Card
Read User (Card)/
(PIN#)/(fingerprint 3 �mes)
Read Master Card Again
12 3
45 6
78 9
*0 #
Sistemas de comunicación S.A.
12 3
45 6
78 9
*0 #
Sistemas de comunicación S.A.
12 3
45 6
78 9
*0 #
Master card
(To Add user)
Read Master Card
Read User (Card)/
(PIN#)/(fingerprint 3 �mes)
Read Master Card Again
x2
12 3
45 6
78 9
*0 #
12 3
45 6
78 9
*0 #
8.2. USER DELETION
8.3. BASIC PROGRAMMING WITH MASTER CARD
12 3
45 6
78 9
*0 #
Master code
(by default: 123456)
12 3
45 6
78 9
*0 #
#
12 3
45 6
78 9
*0 #
2
12 3
45 6
78 9
*0 #
Sistemas de comunicación S.A.
Approach card
to the reader
12 3
45 6
78 9
*0 #
Master code
(by default: 123456)
12 3
45 6
78 9
*0 #
#
12 3
45 6
78 9
*0 #
PIN
(ac�va�on code
4-digit)
12 3
45 6
78 9
*0 #
#
12 3
45 6
78 9
*0 #
2
CARD
DELETION
PIN
DELETION

6
CODEPROX-N
www.golmar-seguridad.es
PIN registration with automatic recording position.
PIN deletion by entering the PIN number to be deleted.
Maximum number of records is 990. User IDs from 0 to 989.
Maximum number of records is 990. User IDs from 0 to 989.
IMPORTANT: do not enter user IDs with zeros before the ID value.
IMPORTANT: do not enter user IDs with zeros before the ID value.
Example: * 987654 # 1 4543 #
Example: * 987654 # 2 4543 #
Example: * 987654 # 1 1 # APPROACH CARD
Example: * 987654 # 1 1 # 4543 #
9.1.4.PIN REGISTRATION (AUTO ID)
9.1.6.PIN DELETION
9.1.3.CARD REGISTRATION (specic ID)
9.1.5.PIN REGISTRATION (specic ID)
Enter administrator mode
*MASTER CODE #
Enter administrator mode
*MASTER CODE #
Enter administrator mode
*MASTER CODE #
Enter administrator mode
*MASTER CODE #
1PIN #
2INTRODUCE PIN #
1USER ID
(0-989) #
1USER ID
(0-989) #
APPROACH CARD
PIN #
It is highly recommended to modify the master code:
9.1.1.CHANGE MASTER CODE
Example: * 123456 # 0 987654 # 987654 #
Enter administrator mode
*MASTER CODE #0NEW MASTER CODE
(6 DIGITS) #NEW MASTER CODE
(6 DIGITS) #
Card registration with automatic registration.
Example: * 987654 # 1 APPROACH CARD
9.1.2.CARD REGISTRATION (AUTO ID)
Enter administrator mode
*MASTER CODE #1APPROACH CARD
9.ADVANCED PROGRAMMING
9.1. PROGRAMMING
Perform the following sequence to enter programming:
Once in programming, perform the desired programming sequence. e dierent system programming sequences are detailed below.
IMPORTANT
e reader will indicate the access to programming with the “green” lighting up and then the ashing LED in “red” . At the start of the program-
ming sequence (function to be programmed) the led will be “orange”.
To exit programming, press “*” and the reader will go to standby, the status LED will be “steady red”. If you do not press anything, aer 30
seconds the reader will also automatically exit programming.
Enter to administrator mode
*MASTER CODE
(by default: 123456) #

7
CODEPROX-N
www.golmar-seguridad.es
Deletion of cards by approaching the card to be deleted.
Enter the ID corresponding to the user to be deleted.
Example: * 987654 # 2 APPROACH CARD
Example: * 987654 # 2 1 #
9.1.7.CARD DELETION
9.1.8.DELETING CARDS OR PIN (specic ID)
Enter administrator mode
*MASTER CODE #
Enter administrator mode
*MASTER CODE #
2APPROACH CARD
2USER ID
(0-989) #
10.3. RELAY SETTINGS
Example: * 987654 # 4 15 #
Example: * 987654 # 4 0 #
Enter administrator mode
*MASTER CODE #
Enter administrator mode
*MASTER CODE #
41-99 #
40#
10.3.1.PULSE MODE
10.3.2.LATCHING MODE
e pulse can be active from 1 to 99 seconds. In the example, the value 15 has been entered, so it would be active for 15 seconds.
Default value: 5 seconds.
e relay switches to ON/OFF mode.
10.OTHER SETTINGS
10.1. IDENTIFICATION MODE
Example: * 987654 # 30 #
Example: * 987654 # 32 #
Enter administrator mode
*MASTER CODE #
Enter administrator mode
*MASTER CODE #
30 #
32 #
10.1.1.IDENTIFICATION BY CARD OR PIN (default value)
10.1.2.IDENTIFICATION BY CARD ONLY
10.2. ALARM SETTINGS (TAMPER)
Example: * 987654 # 52 #
Enter administrator mode
*MASTER CODE #5(0-3) #
10.2.1.ACTIVATE TAMPER
e tamper alarm activation time is from 0 to 3 minutes. In the example, the value 52 has been entered, so it would be active for 2 minutes.
Default value: 51 (1 minute).
It is possible to change the PIN, but it is not necessary to access programming. When the reader is in standby mode, enter:
Example: * 1 # 4543 # 6688 # 6688 #
9.1.9.MODIFY PIN
*USER ID #PIN TO MODIFY #NEW PIN #NEW PIN #

8
CODEPROX-N
www.golmar-seguridad.es
e LED will start blinking and the reader will be locked for 10 minutes. To return to the normal state, wait 10 minutes or restart the reader..
In case a valid user card or MASTER card is approached, the alarm will stop.
Example: * 987654 # 61 #
Example: * 987654 # 62 #
Enter administrator mode
*MASTER CODE #
Enter administrator mode
*MASTER CODE #
61 #
62 #
10.4.2.10-MINUTES ACCESS LOCKOUT
10.4.3.ALARM
10.5. DELETION OF ALL USERS
Example: * 987654 # 2 0000 #
10.4. RESET TO FACTORY DEFAULTS
1. Turn o the power.
2. Press and hold the exit button*.
3. Turn on the power.
4. When you hear 2 beeps, release the output button*.
5. e LED will light up yellow.
6. Approach a 125KHz card through the reader.
7. e light will illuminate red and the equipment will be reset to factory defaults.
**Requires exit push button, yellow wire (OPEN) and black wire (GND) to be connected.
e reset returns the reader to factory defaults. Restoring the conguration and the master code. User information will be kept.
- is process generates a MASTER card replacing the previous one.
- In case you do not wish to replace the current master card, press the * button instead of step 6 to nalise the reset.
NOTE
IMPORTANT:
Before performing this function, make sure that it is OK to REMOVE all previously registered users.
Enter administrator mode
*MASTER CODE #20000 #
11.STATUS DISPLAYS
OPERATING STATUS COLOUR LED BUZZER
Stand by Rojo -
Enter programming mode Flashing red Short beep
In programming mode Orange Short beep
Operation error - 3 beeps
Exit programming mode Red Short beep
Door open Green Short beep
Alarm Flashing red Beeps
10.4. LOCKOUT ALARM (FAILED ATTEMPTS)
Example: * 987654 # 60 #
Enter administrator mode
*MASTER CODE #60 #
10.4.1.LOCKOUT DISABLED (default value)
e lockout alarm will be triggered aer 10 unsuccessful card/PIN entry attempts. e factory default is OFF, but it can be set to deny access for
10 minutes or to activate the alarm aer triggering.

9
CODEPROX-N
www.golmar-seguridad.es
NOTE: e door opener (AP) does not activate the lock release until the pulse on the CODEPROX-N reader has been nished. To avoid opening
delays set the minimum pulse time to 1 second at the reader:
12.CONNECTION DIAGRAM WITH VIDEO DOOR SYSTEM
NC
COM
NO
OPEN
GND
D1
DO
Blue
Grey
Brown
Red
Yellow
Green
Black
+12V DC
+12V
GND
AP+
+
AP+
C1 NA1AP- C2 NA2
GND
BUS
Relé 2Relé 1
_
12Vdc
12
BUS
NC2
CCTV
1 2 3 4 5 6 7 8 9 10
ON
RST
GND
CLK
SDA
3V
Aout
BUS(M) BUS(PL)
AP+
AP-
+ NA1
-C1
Lock release
12Vdc/270mA
White
12 3
45 6
78 9
*0 #
Enter administrator mode
*MASTER CODE #41#
13.WIEGAND
13.1. CONNECTION DIAGRAM
e following chapter describes how to use the CODEPROX-N reader in an iP Opener system with a Wiegand controller.
NC
COM
NO
OPEN
GND
D1
DO
Blue
Grey
Brown
Red
Yellow
Green
Black
+12V DC
White
Door 1
12V+
0V
REX+
REX-/DS-
DS+
C
NC
NO
WO
W1
GREEN LED
RED LED
BUZZER
LED 3
TAMPER
0V
Door1
12V+
0V
REX+
REX-/DS-
DS+
C
NC
NO
WO
W1
GREENLED
REDLED
BUZZER
LED3
TAMPER
0V
Door2
12V+
0V
REX+
REX-/DS-
DS+
C
NC
NO
WO
W1
GREENLED
REDLED
BUZZER
LED3
TAMPER
0V
12 3
45 6
78 9
*0 #

10
CODEPROX-N
www.golmar-seguridad.es
13.2. PROGRAMMING
Generate a user with credential type “Other (decimal)” and enter in the eld “code” the ID of the card or key fob:
At this point the card or key fob will be registered in iP Opener and your access will be granted:
Generate a user with credential type “Other (decimal)”, following the next format when lling in the eld “Code”:
4-digit PIN (X equals PIN): 0000XXXX
5-digit PIN (X equals PIN): 000XXXXX
6-digit PIN (X equals PIN): 00XXXXXX
13.2.1.PROGRAMMING CARD
13.2.2.PROGRAMING PIN
0009701804
Sistemas de comunicación S.A.
PROKEY ID
20710008 0004601388 070,16868
PROKEY ID TAGKEY ID

11
CODEPROX-N
www.golmar-seguridad.es
Example with PIN code registration 4543:
At this point the PIN code will be registered in iP Opener:
Place a embedding box AP-1 (20363401). Attach the reader to the box with the metric screws
supplied. en cover the screws with the supplied screw
cover labels.
12
IMPORTANT: e reader incorporates an anti-tamper LDR sensor on the back of the reader ..
It is light-sensitive, so if light shines on the sensor aer placing the reader, the tamper alarm will be triggered.
NOTE:
e use of the reader integrated in the iP Opener system implies the loss of the buzzer and led states ( there will be no visual and audi-
ble conrmation on the reader of validated or denied accesses).
60mm
12 3
45 6
78 9
*0 #
14.TYPES OF INSTALLATION
14.1. STAND-ALONE INSTALLATION
As briey mentioned in section “5.INSTALLATION”, the installation of these readers is designed to be integrated in Nexa panels. However,
you can choose to install the reader independently on a embedding box. In this case, follow the steps below:

12
CODEPROX-N
www.golmar-seguridad.es
14.2. INSTALLATION ON NEXA PANEL
e integration of the reader on the Nexa panel requires the use of the reader in kit format:
N3000/CODEPROX-N (20700017), kit for CODEPROX-N reader mounting on Nexa Aluminium.
NX3000/CODEPROX-N (20700018), kit for CODEPROX-N reader mounting on Nexa Inox.
Due to the fact that the kit is supplied with the reader assembled in a special Nexa cover:
Front view of Nexa Aluminium cover panel with reader
Front view of Nexa Inox cover panel with reader
Back view of Nexa Aluminium cover panel with reader
Back view of Nexa Inox cover panel with reader
12 3
45 6
78 9
*0 #
12 3
45 6
78 9
*0 #

Sist
emas de comunicación S.A.
C/ Silici 13. Poligon Industrial Famadas
08940 – Cornellà del llobregat – Spain
golmar@golmar.es
Tel: 93 480 06 96
www.golmar-seguridad.es
Golmar reserves the right to make any changes without notice.
Table of contents
Other golmar IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Gianni Industries
Gianni Industries GEM DG-1000M Specification sheet

PNI
PNI PB410 user manual

Carrier
Carrier Supra iBox BT LE user guide

IEI Technology
IEI Technology SSW-iLW installation manual

Nortech
Nortech NanoQuest Lite installation guide

Alarm Lock
Alarm Lock Trilogy DL3000 Series Programming instructions

CAMDEN
CAMDEN Invision CV-601 MProx installation instructions

Savi
Savi SaviTag 600 Series installation guide

Amano
Amano FPT-80 quick start guide

SensAble
SensAble DORTAG VI user manual

Transmitter Solutions
Transmitter Solutions Dolphin DOLCWIUHF-ER-902 manual

Idemia
Idemia MorphoWave Compact installation guide