golmar TCD-Nexa/G2+ User manual

TART WH G2+ ES4 REV.0123
Coded panel and NFC access
control
Coded panel with display and
NFC scontrol acces
Coded panel
Coded panel with
display
INSTRUCTION MANUAL
TCD-NEXA/G2+ EN REV.0123
TECNOLOGY

2
CD-NEXA/G2+ WIRING DIAGRAMS
INTRODUCTION
First and foremost we would like to thank you for purchasing this product.
Our commitment to satisfying our customers can be seen from our ISO-9001 certification and from the manufacturing of
products like this one.
Its advanced technology and exacting quality control will ensure that customers and users enjoy the many features this
system offers. To obtain the maximum benefit from these features and a properly wired installation, we kindly
recommend that you spend a few minutes of your time reading this manual.
MOUNTING CONFIGURATIONS
Push button door panel with NFC access controlG2+ ................................................................................................. 3-.5
Coded panel with NFC access ............G2+ control ......................................................................................................6-8
Coded panel with display and NFC accessG2+ control NFC...................................................................................... -119
Coded panel G2+ ..................................................... ............................................................................................... 12-14.
Coded panel with G2+ ...... -display .................................................................................................... ........................15 17
COM
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relé 2
Relé 1
_
12Vdc
12
ON
2 3 4 5 6 7 8 9 10
1 2 3 P1
P2
CN2 CN3
EL632 G2+ SE/
EL642 G2+ CD-NEXA G2+ EL3002
EL4502/NFC
N3403/AL
N3301/AL EL3002
EL3002
NEXA BUS CONNECTION CD-NEXA/G2+ WITH ADDITIONAL FA-PLUS/C POWER SUPPLY UNIT:
NOTE: EL632 EL642 G2+ sound module should be connected to the power supply unit. The N are powered byOnly the / exa modules
the Nexa Bus link connector.
NOTE: Maximum 3 Nexa modules can be connected (without additional power supply)FA-PLUS/C .
Example below of additional FA-PLUS/C power supply unit connected to the CD-NEXA/G2+ module, when there are more
than 3 Nexa modules.
+18v
_
+18v
_
FA-PLUS/C
power supply
For further information, please contact our technical support services.
Status LED of the CD-NEXA/G2+ module:
Led blinking (green): CD-NEXA/G2+ module connected and backbone power supply.
Led blinking (red): CD-NEXA/G2+ module connected and local FA-PLUS/C power supply.

Push button panel
access control
G2+ with NFC

COMBINED WITH NEXA MODULAR / NEXA INOX:
The connection of the access control module with EL632/G2+ and EL642/G2+ sound modules shall be done by using the
Nexa Bus link cable supplied with the CD-Nexa/G2+ module.
4
ESQUEMAS DE INSTALACIÓN CD-NEXA/G2+
CN3CN3
C2NC1 NC2
CN1
P
~ ~ C1NA1 NA2 PL1 PL2
-
Door panel with
EL632 G2+/ SE - EL642/G2+ FA-G2+
power supply
NA2
+AP-
C1 NA1AP+ C2
AP+
GND
BUSBUS
Relé 2Relé 1
_
12Vdc
NC2
CCTV
Lock release
max. 12 Vdc/270mA.
J21CN2
EL4502/NFC
Access control module CD-Nexa/G2+
CN4
NOTE: EL632 EL642 G2+ sound module should be connected to the power supply unit. The EL4502/NFCOnly the /
module are powered by the Nexa Bus link connector.
NOTE: Maximum 3 Nexa modules can be connected (without additional FA-PLUS/C power supply). See page 2 for more
than 3 Nexa modules connection CD-NEXA/G2+ with additional FA-PLUS/C power supply unit.
For more information, please contact our technical support services.
Insert one end of the Nexa Bus link hose supplied with the CD-NEXA/G2+ module into the sound module connector and
the other end into CD-Nexa/G2+ module CN2 connector. Then insert the one end of the Nexa Bus link hose supplied
with the EL4502/NFC module into CD-NEXA CN3 connector and the other end into either of the two connectors placed
on bottom right of the EL4502/NFC module.
Connection of the Nexa Bus:
EL4502/NFC
COM
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relé 2Relé 1
_
12Vdc
12
ON
2 3 4 5 6 7 8 9 10
1 2 3 P1
P2
EL-632/G2+
EL-6 2/G2+4 CN2 CN3
CD-NEXA/G2+

5
CD-NEXA/G2+ WIRING DIAGRAMS
PUSH BUTTONS DOOR PANEL WITH NEXA MODULAR / NEXA INOXG2+ & NFC CONTROL ACCESS
Configur the end of line ine
the last monitor Dip 8 to ON
or last terminal Dip 10 to ON. Lock release
max. 12 Vdc/270mA.
BUS BUS
BUS BUS
D4
D3
D2
D1
D4L- 2G +
Set to ON the end of line in
the last distributor.
AP
Distances and cross sections:
D -G24L +
A
D
B
D
(1)
(1)
FA-G2+
ART 4/G2+
Important:
, .see quick guide that is attached with sound module
For a.c. lock release or a second lock release
For more information of the ART 4 G2+, ART 4 LITE/G2+ monitor & ART1/G2+ or T-ART/G2+ terminal, see the quick guide that is attached with its
corresponding product.
(1)
**
( )
( )2
*
( )
BUS BUS
BUS BUS
D4
D3
D2
D1
D4L- 2G +
ART 4/G2+
Master
BUS BUS
APARTMENT 31
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
ART 4/G2+
Master
BUS BUS
APARTMENT 30
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
ART 4/G2+
Master
BUS BUS
APARTMENT 4
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
APARTMENT 2
ART 4/G2+
Master
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
BUS BUS
ART 4/G2+
Master
BUS BUS
APARTMENT 1
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
Mains
100~240Vac
BUS (M) BUS (PL)
FA-G2+
LN
D D
ART 4/G2+
C
NA2
+AP-
C1 NA1AP+ C2
AP+
GND
BUSBUS
Relé 2
Relé 1
_
12Vdc
NC2
CCTV
1 2 3 4 5 6 7 8 910
ON
End of
line
ON
OFF
End of
line
*
( )
ABC
80m 80m 80m
Cable D
30m
B+C+D
190m
E
15m
RAP-GTWIN/HF 2x1mm
2
Coded Panel
Mixed installation: Up to 32 elements (ART 4/G2+ or ART 4 LITE/G2+ monitors / ART 1/G2+ or T-ART/G2+
audio terminals), 8 D4L-G2+ distributors and Golmar .d.c lock release
ART 1/G2+
Slave 1
BUS
AUX
APARTMENT 31
**
( )2 ( )
ON
1 2 3 4 5 6 7 8 9 10
T-ART/G2+
Master
BUS
APARTMENT 3
**
( )2 ( )
ON
1 2 3 4 5 6 7 8 9 10
Additional ART 1/G2+ terminal (in the same apartment)
ART 1/G2+
AUX
T-ART/G2+
AUX
AUX
E

Coded panel G2+
with NFC access
control

The connection of the access control N3301 module and withthe NFC control access módule EL632/G2+ and
EL642/G2+ sound modules shall be done by using the Nexa Bus link cable supplied with the CD-Nexa/G2+ module.
7
CD-NEXA/G2+ WIRING DIAGRAMS
CN3CN3
C2NC1 NC2
CN1
P
~ ~ C1NA1 NA2 PL1 PL2
-
Door panel with
EL632/G2+ SE - EL642/G2+ FA-G2+
power supply
NA2
+AP-
C1 NA1AP+ C2
AP+
GND
BUSBUS
Relé 2Relé 1
_
12Vdc
NC2
CCTV
Lock release
max. 12 Vdc/270mA.
J21CN2
Access control module CD-Nexa/G2+
CN4
EL4502/NFC
N3301
or
COMBINED WITH NEXA MODULAR / NEXA INOX:
COM
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relé 2Relé 1
_
12Vdc
12
ON
2 3 4 5 6 7 8 9 10
1 2 3 P1
P2
EL-632/G2+
EL-6 2/G2+4
NOTE: EL632 EL642 G2+ sound module should be connected to the power supply unit. The N3301 module,Only the /
EL4502/NFC module and EL3002 module, are powered by the Nexa Bus link connector.
NOTE: Maximum 3 Nexa modules can be connected (without additional FA-PLUS/C power supply). See page 2 for more
than 3 Nexa modules connection CD-NEXA/G2+ with additional FA-PLUS/C power supply unit.
For more information, please contact our technical support services.
Insert one end of the Nexa Bus link hose supplied with the CD-Nexa/G2+ module into the sound module connector and
the other end into CD-Nexa/G2+ module CN2 connector. Then insert the one end of the Nexa Bus link hose supplied
with the N3301 module into CD-Nexa CN3 connector and the other end into either of the two connectors placed on
bottom right of the N3301 module. Insert the one end of the Nexa Bus link hose supplied with the EL4502/NFC module
into N3301 free connector and the other end into either of the two connectors placed on bottom right of the
EL4502/NFC module. The EL3002 door panel lighting module can be connected in the same way.
CN2 CN3
Connection of the Nexa Bus:
CD-NEXA/G2+ EL3002
N3301/AL
PL2
NC2 P
Relé 2
1 2 3
ON
DIP
4 5
C2
NA2NC1
C1
NA1
~ ~
Relé 1
12 Vac
18 Vdc
EL4502/NFC

8
CD-NEXA/G2+ WIRING DIAGRAMS
CODED PANEL WITH NEXA MODULAR / NEXA INOXG2+ & NFC ACCESS CONTROL
Configur the end of line ine
the last monitor Dip 8 to ON
or last terminal Dip 10 to ON. Lock release
max. 12 Vdc/270mA.
BUS BUS
BUS BUS
D4
D3
D2
D1
D4L- 2G +
Set to ON the end of line in
the last distributor.
AP
Distances and cross sections:
D -G24L +
A
D
B
D
(1)
(1)
FA-G2+
ART 4/G2+
Important:
, .see quick guide that is attached with sound module
For a.c. lock release or a second lock release
For more information of the ART 4 G2+, ART 4 LITE/G2+ monitor & ART1/G2+ or T-ART/G2+ terminal, see the quick guide that is attached with its
corresponding product.
(1)
**
( )
( )2
*
( )
BUS BUS
BUS BUS
D4
D3
D2
D1
D4L- 2G +
ART 4/G2+
Master
BUS BUS
APARTMENT 31
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
ART 4/G2+
Master
BUS BUS
APARTMENT 30
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
ART 4/G2+
Master
BUS BUS
APARTMENT 4
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
APARTMENT 2
ART 4/G2+
Master
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
BUS BUS
ART 4/G2+
Master
BUS BUS
APARTMENT 1
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
Mains
100~240Vac
BUS (M) BUS (PL)
FA-G2+
LN
D D
ART 4/G2+
C
NA2
+AP-
C1 NA1AP+ C2
AP+
GND
BUSBUS
Relé 2
Relé 1
_
12Vdc
NC2
CCTV
1 2 3 4 5 6 7 8 910
ON
End of
line
ON
OFF
End of
line
*
( )
ABC
80m 80m 80m
Cable D
30m
B+C+D
190m
E
15m
RAP-GTWIN/HF 2x1mm
2
Coded Panel
Mixed installation: Up to 32 elements (ART 4/G2+ or ART 4 LITE/G2+ monitors / ART 1/G2+ or T-ART/G2+
audio terminals), 8 D4L-G2+ distributors and Golmar .d.c lock release
ART 1/G2+
Slave 1
BUS
AUX
APARTMENT 31
**
( )2 ( )
ON
1 2 3 4 5 6 7 8 9 10
T-ART/G2+
Master
BUS
APARTMENT 3
**
( )2 ( )
ON
1 2 3 4 5 6 7 8 9 10
Additional ART 1/G2+ terminal (in the same apartment)
ART 1/G2+
AUX
T-ART/G2+
AUX
AUX
E

Coded panel
and NFC access
with display G2+
control

10
CD-NEXA/G2+ WIRING DIAGRAMS
COMBINED WITH NEXA MODULAR / NEXA INOX:
NOTE: EL632 EL642 G2+ sound module should be connected to the power supply unit. The EL4502/NFCOnly the /
module, N3301/AL module and the N3403/AL display module, are powered by the Nexa Bus link connector.
NOTE: Maximum 3 Nexa modules can be connected (without additional FA-PLUS/C power supply). See page 2 for more
than 3 Nexa modules connection CD-NEXA/G2+ with additional FA-PLUS/C power supply unit.
For more information, please contact our technical support services.
Insert one end of the Nexa Bus link hose supplied with the CD-Nexa/G2+ module into the sound module connector and
the other end into CD-Nexa/G2+ module CN2 connector. Then insert the one end of the Nexa Bus link hose supplied
with the EL4502/NFC module into CD-Nexa CN3 connector and the other end into either of the two connectors placed
on bottom right of the EL4502/NFC module. Insert the one end of the Nexa Bus link hose supplied with the N3301/AL
module into EL4502/NFC free connector and the other end into either of the two connectors placed on bottom right of
the N3301/AL module. The module can be connected in the same way.display N3403/AL
Connection Nexa Bus:of the
COM
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relé 2
Relé 1
_
12Vdc
12
ON
2 3 4 5 6 7 8 9 10
1 2 3 P1
P2
EL-632/G2+
EL-6 2/G2+4 CN2 CN3
CD-NEXA/G2+
EL4502/NFC
N3301/AL
N3403/AL
1 2 3
ON
DIP
4 5
The connection of the access control N3301 module, withthe NFC control access módule and display module
EL632/G2+ and EL642/G2+ sound modules shall be done by using the Nexa Bus link cable supplied with the CD-
Nexa/G2+ module.
CN3CN3
C2NC1 NC2
CN1
P
~ ~ C1NA1 NA2 PL1 PL2
-
Door panel with
EL632/G2+ SE - EL642/G2+ FA-G2+
power supply
NA2
+AP-
C1 NA1AP+ C2
AP+
GND
BUSBUS
Relé 2Relé 1
_
12Vdc
NC2
CCTV
Lock release
max. 12 Vdc/270mA.
J21CN2
Access control module CD-Nexa/G2+
CN4
EL4502/NFC
N3301
or

11
CD-NEXA/G2+ WIRING DIAGRAMS
CODED PANEL WITH DISPLAY NEXA MODULAR / NEXA INOXG2+ & NFC ACCESS CONTROL
Configur the end of line ine
the last monitor Dip 8 to ON
or last terminal Dip 10 to ON. Lock release
max. 12 Vdc/270mA.
BUS BUS
BUS BUS
D4
D3
D2
D1
D4L- 2G +
Set to ON the end of line in
the last distributor.
AP
Distances and cross sections:
D -G24L +
A
D
B
D
(1)
(1)
FA-G2+
ART 4/G2+
Important:
, .see quick guide that is attached with sound module
For a.c. lock release or a second lock release
For more information of the ART 4 G2+, ART 4 LITE/G2+ monitor & ART1/G2+ or T-ART/G2+ terminal, see the quick guide that is attached with its
corresponding product.
(1)
**
( )
( )2
*
( )
BUS BUS
BUS BUS
D4
D3
D2
D1
D4L- 2G +
ART 4/G2+
Master
BUS BUS
APARTMENT 31
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
ART 4/G2+
Master
BUS BUS
APARTMENT 30
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
ART 4/G2+
Master
BUS BUS
APARTMENT 4
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
APARTMENT 2
ART 4/G2+
Master
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
BUS BUS
ART 4/G2+
Master
BUS BUS
APARTMENT 1
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
Mains
100~240Vac
BUS (M) BUS (PL)
FA-G2+
LN
D D
ART 4/G2+
C
NA2
+AP-
C1 NA1AP+ C2
AP+
GND
BUSBUS
Relé 2
Relé 1
_
12Vdc
NC2
CCTV
1 2 3 4 5 6 7 8 910
ON
End of
line
ON
OFF
End of
line
*
( )
ABC
80m 80m 80m
Cable D
30m
B+C+D
190m
E
15m
RAP-GTWIN/HF 2x1mm
2
Coded Panel
Mixed installation: Up to 32 elements (ART 4/G2+ or ART 4 LITE/G2+ monitors / ART 1/G2+ or T-ART/G2+
audio terminals), 8 D4L-G2+ distributors and Golmar .d.c lock release
ART 1/G2+
Slave 1
BUS
AUX
APARTMENT 31
**
( )2 ( )
ON
1 2 3 4 5 6 7 8 9 10
T-ART/G2+
Master
BUS
APARTMENT 3
**
( )2 ( )
ON
1 2 3 4 5 6 7 8 9 10
Additional ART 1/G2+ terminal (in the same apartment)
ART 1/G2+
AUX
T-ART/G2+
AUX
AUX
E

Code panel
G2+

13
CD-NEXA/G2+ WIRING DIAGRAMS
CN3CN3
C2NC1 NC2
CN1
P
~ ~ C1NA1 NA2 PL1 PL2
-
Door panel with
/EL632 G2+ SE - EL642/G2+ FA-G2+
power supply
NA2
+AP-
C1 NA1AP+ C2
AP+
GND
BUSBUS
Relé 2Relé 1
_
12Vdc
NC2
CCTV
Lock release
max. 12 Vdc/270mA.
J21CN2
N3301
Access control module CD-Nexa/G2+
CN4
COMBINED WITH NEXA MODULAR / NEXA INOX:
The connection of the access control N3301 module with EL632/G2+ and EL642/G2+ sound modules shall be done by
using the Nexa Bus link cable supplied with the CD-Nexa/G2+ module.
COM
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relé 2
Relé 1
_
12Vdc
12
ON
2 3 4 5 6 7 8 9 10
1 2 3 P1
P2
EL-632/G2+
EL-6 2/G2+4
NOTE: EL632 EL642 G2+ sound module should be connected to the power supply unit. The N3301 module,Only the /
and EL3002 module, are powered by the Nexa Bus link connector.door panel lighting
NOTE: Maximum 3 Nexa modules can be connected (without additional FA-PLUS/C power supply). See page 2 for more
than 3 Nexa modules connection CD-NEXA/G2+ with additional FA-PLUS/C power supply unit.
For more information, please contact our technical support services.
Insert one end of the Nexa Bus link hose supplied with the CD-Nexa/G2+ module into the sound module connector and
the other end into CD-Nexa/G2+ module CN2 connector. Then insert the one end of the Nexa Bus link hose supplied
with the N3301 module into CD-Nexa CN3 connector and the other end into either of the two connectors placed on
bottom right of the N3301 module. Insert the one end of the Nexa Bus link hose supplied with the EL3002 door panel
lighting module, into free N3301 connector and the other end into either of the three connectors placed on bottom of
the EL3002 module. The second EL3002 door panel lighting module can be connected in the same way.
CN2 CN3
Connection of the Nexa Bus:
CD-NEXA/G2+ EL3002
EL3002N3301/AL

14
CD-NEXA/G2+ WIRING DIAGRAMS
Configur the end of line ine
the last monitor Dip 8 to ON
or last terminal Dip 10 to ON. Lock release
max. 12 Vdc/270mA.
BUS BUS
BUS BUS
D4
D3
D2
D1
D4L- 2G +
Set to ON the end of line in
the last distributor.
AP
Distances and cross sections:
D -G24L +
A
D
B
D
(1)
(1)
FA-G2+
ART 4/G2+
Important:
, .see quick guide that is attached with sound module
For a.c. lock release or a second lock release
For more information of the ART 4 G2+, ART 4 LITE/G2+ monitor & ART1/G2+ or T-ART/G2+ terminal, see the quick guide that is attached with its
corresponding product.
(1)
**
( )
( )2
*
( )
BUS BUS
BUS BUS
D4
D3
D2
D1
D4L- 2G +
ART 4/G2+
Master
BUS BUS
APARTMENT 31
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
ART 4/G2+
Master
BUS BUS
APARTMENT 30
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
ART 4/G2+
Master
BUS BUS
APARTMENT 4
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
APARTMENT 2
ART 4/G2+
Master
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
BUS BUS
ART 4/G2+
Master
BUS BUS
APARTMENT 1
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
Mains
100~240Vac
BUS (M) BUS (PL)
FA-G2+
LN
D D
ART 4/G2+
C
NA2
+AP-
C1 NA1AP+ C2
AP+
GND
BUSBUS
Relé 2
Relé 1
_
12Vdc
NC2
CCTV
1 2 3 4 5 6 7 8 910
ON
End of
line
ON
OFF
End of
line
*
( )
ABC
80m 80m 80m
Cable D
30m
B+C+D
190m
E
15m
RAP-GTWIN/HF 2x1mm
2
Coded Panel
Mixed installation: Up to 32 elements (ART 4/G2+ or ART 4 LITE/G2+ monitors / ART 1/G2+ or T-ART/G2+
audio terminals), 8 D4L-G2+ distributors and Golmar .d.c lock release
ART 1/G2+
Slave 1
BUS
AUX
APARTMENT 31
**
( )2 ( )
ON
1 2 3 4 5 6 7 8 9 10
T-ART/G2+
Master
BUS
APARTMENT 3
**
( )2 ( )
ON
1 2 3 4 5 6 7 8 9 10
Additional ART 1/G2+ terminal (in the same apartment)
ART 1/G2+
AUX
T-ART/G2+
AUX
AUX
WIRING DIAGRAM CODED PANEL NEXA MODULAR / NEXA INOX
E

Continúa
Coded panel
with display G2+

COM
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relé 2Relé 1
_
12Vdc
12
ON
2 3 4 5 6 7 8 9 10
1 2 3 P1
P2
16
CD-NEXA/G2+ WIRING DIAGRAMS
The connection of the display N3403/AL module with EL632/G2+ and EL642/G2+ sound modules shall be done by
using the Nexa Bus link cable supplied with the CD-Nexa/G2+ module.
NOTE: EL632 EL642 G2+ sound module should be connected to the power supply unit. The N3403/ALOnly the /
module and N3301/AL module, are powered by the Nexa Bus link connector.
NOTE: Maximum 3 Nexa modules can be connected (without additional FA-PLUS/C power supply). See page 2 for more
than 3 Nexa modules connection CD-NEXA/G2+ with .additional FA-PLUS/C power supply unit
For more information, please contact our technical support services.
CN2 CN3
CD-NEXA G2+
EL-632/G2+
N3403/AL
N3301/AL
EL-6 2/G2+4
Insert one end of the Nexa Bus link hose supplied with the CD-Nexa/G2+ module into the sound module connector and
the other end into CD-Nexa/G2+ module CN2 connector. Then insert the one end of the Nexa Bus link hose supplied
with the N3403/AL module into CD-Nexa CN3 connector and the other end into either of the two connectors placed
on bottom right of the N3403/AL module. Insert the one end of the Nexa Bus link hose supplied with the N3301/AL
module, into free N3403/AL connector and the other end into either of the two connectors placed on bottom right of
the N3301/AL module.
Connection of the Nexa Bus:
COMBINED WITH NEXA MODULAR / NEXA INOX:
CN3CN3
C2NC1 NC2
CN1
P
~ ~ C1NA1 NA2 PL1 PL2
-
Door panel with
/EL632 G2+ SE - EL642/G2+ FA-G2+
power supply
NA2
+AP-
C1 NA1AP+ C2
AP+
GND
BUSBUS
Relé 2
Relé 1
_
12Vdc
NC2
CCTV
Lock release
max. 12 Vdc/270mA.
J21CN2
N3301
Access control module CD-Nexa/G2+
CN4
CN7CN8
N3403
moduleDisplay

WIRING DIAGRAM WITHCODED PANEL DISPLAY NEXA MODULAR / NEXA INOX
17
CD-NEXA/G2+ WIRING DIAGRAMS
Configur the end of line ine
the last monitor Dip 8 to ON
or last terminal Dip 10 to ON. Lock release
max. 12 Vdc/270mA.
BUS BUS
BUS BUS
D4
D3
D2
D1
D4L- 2G +
Set to ON the end of line in
the last distributor.
AP
Distances and cross sections:
D -G24L +
A
D
B
D
(1)
(1)
FA-G2+
ART 4/G2+
Important:
, .see quick guide that is attached with sound module
For a.c. lock release or a second lock release
For more information of the ART 4 G2+, ART 4 LITE/G2+ monitor & ART1/G2+ or T-ART/G2+ terminal, see the quick guide that is attached with its
corresponding product.
(1)
**
( )
( )2
*
( )
BUS BUS
BUS BUS
D4
D3
D2
D1
D4L- 2G +
ART 4/G2+
Master
BUS BUS
APARTMENT 31
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
ART 4/G2+
Master
BUS BUS
APARTMENT 30
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
ART 4/G2+
Master
BUS BUS
APARTMENT 4
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
APARTMENT 2
ART 4/G2+
Master
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
BUS BUS
ART 4/G2+
Master
BUS BUS
APARTMENT 1
**
( )2 ( )
ON
1 2 3 4 5 6 7 8
Mains
100~240Vac
BUS (M) BUS (PL)
FA-G2+
LN
D D
ART 4/G2+
C
NA2
+AP-
C1 NA1AP+ C2
AP+
GND
BUSBUS
Relé 2
Relé 1
_
12Vdc
NC2
CCTV
1 2 3 4 5 6 7 8 910
ON
End of
line
ON
OFF
End of
line
*
( )
ABC
80m 80m 80m
Cable D
30m
B+C+D
190m
E
15m
RAP-GTWIN/HF 2x1mm
2
Coded Panel
Mixed installation: Up to 32 elements (ART 4/G2+ or ART 4 LITE/G2+ monitors / ART 1/G2+ or T-ART/G2+
audio terminals), 8 D4L-G2+ distributors and Golmar .d.c lock release
ART 1/G2+
Slave 1
BUS
AUX
APARTMENT 31
**
( )2 ( )
ON
1 2 3 4 5 6 7 8 9 10
T-ART/G2+
Master
BUS
APARTMENT 3
**
( )2 ( )
ON
1 2 3 4 5 6 7 8 9 10
Additional ART 1/G2+ terminal (in the same apartment)
ART 1/G2+
AUX
T-ART/G2+
AUX
AUX
E

golmar@golmar.es
www.golmar.es
Sistemas de comunicación S.A.
GOLMAR S.A.
C/ Silici, 13
08940- Cornellá de Llobregat
SPAIN
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis.
Golmar reserves the right to make any modifications without prior notice.
Table of contents
Other golmar IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Altronix
Altronix Maximal3FV installation guide

ACT
ACT ACTENTRY A5 Operating and installation instructions

Altronix
Altronix TROVE T2SSK7F8D installation guide

Austin Hughes
Austin Hughes InfraSolution X Series user manual

Identiv
Identiv MobilisID Installation guide and user's manual

ITLONG
ITLONG ITL-MJ-A user manual